Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 2 BUSYLIGHT A product from Adhesive tape for attachment on table, bracket, etc. With USB Power Adaptor & adhesive tape attachment Need more help? www.plenom.com • 1 pcs Flowscape Busylight • 1 pcs USB Power Adaptor • 1 pcs Adhesive tape for mounting IN THE BOX Please use the adhesive tape to mount the Flowscape Busylight. Please consider standardized placement and visibility in the open office environment. MOUNTING THE PRODUCT FOR DESK STATUS PURPOSE MOUNTING THE PRODUCT FOR ROOM STATUS PURPOSE CONNECTING THE BUSYLIGHT PLEASE NOTE FCC WARNING The device can only be controlled over the LoRaWan network This product is not a USB device- USB cord for power purpose only Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20 cm between the radiator& your body. Please use the adhesive tape and maybe in combination with the bracket (sold seperatly) to place the Busylight with good visibility for office workers. Can be above or next to door/entrance Please make sure the Flowscape Busylight are added as a class C device on the LoRaWAN network (See userguide provided from your network provider) Please make sure LoRaWAN Gateways are in reach of the device. Connect the USB and power adaptor Plug in adaptor to power socket to a power up the Flowscape Busylight The device will start up with a white blink, followed by week yellow color. In this mode it will search for LoRaWan network. The light turns into a week green color when connected to the Lo- RaWan network If no connection is made, the device starts to flash week red after ap- proximately 10 min. A product from
Plenom A/S Address: Pi 2, Soften Hinnerup Favrskov 8382 Denmark Tel.: 004525680139 Fax: 004570701041 E-mail: [email protected] Product Similarity Declaration 2020-12-22 Dear Sir/Madam, We, Plenom A/S hereby declare that we have a product named as kuando® Busylight (Model: kuando® Busylight IoT – For LoRaWAN networks, Flowscape Busylight) was tested by Shenzhen Accurate Technology Co., Ltd., Meanwhile, for our marketing purpose, we would like to list series model Flowscape Busylight) on reports and certificate. They have the same circuit the only difference is model. We confirm that all information above is true, and we’ll be responsible for all the consequences. Please contact me if you have any question. Sincerely Yours, Signature: Name:Allan Kjeldbjerg Title: CEO
Plenom A/S Address: Pi 2, Soften Hinnerup Favrskov 8382 Denmark Tel.: 004525680139 Fax: 004570701041 E-mail: [email protected] QA-FR-170-B FCC Authorization Date: 2020-12-30 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Plenom A/S hereby authorize Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratory Corporation on our behalf shall have the same effect as our own action. We, Plenom A/S the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature Name:Allan Kjeldbjerg Title: CEO
Plenom A/S Address: Pi 2, Soften Hinnerup Favrskov 8382 Denmark Tel.: 004525680139 Fax: 004570701041 E-mail: [email protected] FCC Confidential Authorization Date: 2020-12-30 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AYIK-1582 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Plenom A/S hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature Name:Allan Kjeldbjerg Title: CEO
Antenna
Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. Shenzhen Accurate Technology Co., Ltd. is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.249 TEST REPORT For Plenom A/S Pi 2, Soften Hinnerup Favrskov 8382 Denmark FCC ID: 2AYIK-1582 Report Type: Original Report Product Type: kuando® Busylight Report Number: RTZ201026003-00B Report Date: 2020-12-21 Reviewed By: Candy Li RF En gineer Prepared By: Shenzhen Accurate Technology Co., Ltd. 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China Tel: (0755) 26503290 Fax: (0755) 26503396 Http://www.atc-lab.com Shenzhen Accurate Technology Co., Ltd. Report No.: RTZ201026003-00B FCC Part 15.249 Page 2 of 28 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 TEST METHODOLOGY .................................................................................................................................................. 3 MEASUREMENT UNCERTAINTY .................................................................................................................................... 4 TEST FACILITY ............................................................................................................................................................. 4 SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 JUSTIFICATION ............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 6 SUPPORT CABLE DESCRIPTIONS ................................................................................................................................... 6 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 7 SUMMARY OF TEST RESULTS ............................................................................................................................... 8 TEST EQUIPMENT LIST ........................................................................................................................................... 9 FCC§15.203 - ANTENNA REQUIREMENT ............................................................................................................ 10 APPLICABLE STANDARD ............................................................................................................................................ 10 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 10 FCC §15.207 – AC LINE CONDUCTED EMISSIONS ........................................................................................... 11 APPLICABLE STANDARD ............................................................................................................................................ 11 EUT SETUP ................................................................................................................................................................ 11 EMI TEST RECEIVER SETUP ....................................................................................................................................... 11 TEST PROCEDURE ...................................................................................................................................................... 11 CORRECTED FACTOR & MARGIN CALCULATION ....................................................................................................... 12 TEST RESULTS SUMMARY .......................................................................................................................................... 12 TEST DATA ................................................................................................................................................................ 12 FCC§15.205, §15.209 & §15.249(D) - RADIATED EMISSIONS ............................................................................ 15 APPLICABLE STANDARD ............................................................................................................................................ 15 TEST EQUIPMENT SETUP ............................................................................................................................................ 15 EUT SET…
Text truncated - open the document above for the full version.
Photo of Power Line Conducted Emission Measurement Photo of Radiated Emission Measurement (Below 1G) Photo of Radiated Emission Measurement (Above 1G)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 903.9 MHz - 923.4 MHz | - |