Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Read the manual carefully before use VISUAL BLACKHEAD VACUUM DEVICE Manual Thank you very much for purchasing this product. In order to ensure correct and safe use, please read carefully and keep this manual carefully before use. Attention In order for you to use this product correctly, please read and follow the following safety guidelines carefully. 1. This produc t is not waterproof. Please do not immerse the prod uct in any form of liquid. D o not use the prod uct near water-bat hed bathtu bs, shower trays, washbasins or other water-co ntaining utensils. Please keep the product and power adapter dry. 2. Before using this pr od uct, please dry t he water o r ot her liq uids on yo ur ha nds t o prevent the water or other liquids from entering the interior and damaging the machine. 3. D o not overuse in an area, it may cause the skin to become red andswelling. It is recommended that the stay time in the same area should not ex ceed 3 seconds, an d each nursi ng time should n ot ex ceed 5 minutes. 4. D o not use on injured or fragile skin, and on the chin and mouth, Use in fragile areas such as corners and around the eyes. 5. D o not use on skin with open wounds, acne or pimples. 6. D o not use it on cuts, areas that have undergone cosmetic surgery, areas where the skin is inflamed, itchy and red. 7. If you feel uncomfortable while using it, please stop using it immediately. 8. Conti nu ous use of the b ody for a long time will generate heat, this phenome non is no t a prod uct failure,Please rest assured to use. 9. Conti nu ous use of the b ody for a long time will generate heat, this phenome non is no t a prod uct failure,Please rest assured to use. 10. If you have any skin problems, please consult a doctor before using this product 11. Please put t he p ro duct out of the reach of c hildre n, d o n ot let c hildre n use, it will ca use accidents a nd injuries. Introduction The visual blackhead instr ument uses n on-invasive vacuum negative pressure technol ogy, with 3 special suction heads, which ca n H elps effectively remove blackheads, pimples, dirt an d aging keratin, clears pores and improves muscles skin. Built-in high-definitio n camera, whic h can directly mo nito r the skin co nditi on a nd clearly observe the blackhead quilt D uring the removal process, avoid blindly cleaning or leaking clean skin Structure Function Press and hold the power button for 2 seconds, the instrument is turned on, mode & power indicator Light. ● Shortly press the button after switching on to switch the mode: Soft (soft)/ Normal / Strong/ Standby. ●When the battery is low, the battery indicator light flashes slowly. ●The white indicator of the battery indicator flashes slowly during charging, and the indicator of the battery indicator when fully charged The white light is always on. ●Each gear works for about 5 minutes. Standby mode after 5 minutes, wait The machine will automatically shut down if there is no operation within 10 minutes. ●Press and hold the power button for 2 seconds to shut down. Press and hold for 2 seconds to turn the machine on or off Short press cycle to switch working mode Procedure APP download and installation After scanning the QR code in the user manual with your mobile phone, click to download and install. (If you use WeChat to scan, you need to manually jump to the browser to open) APP function The camera connected to the instrument through the APP is more straight during use Easy to clean pores. ①After turning on the instrument, set the WIF I connection ID on the mobile phone, such as: UD U Beau ty -1234. ②Open the "UD U" APP and enter the home page. If the device is not connected, the APP will The operation guide prompt appears. ③After clicking "Open", you can see the transmission of the instrument camera in the APP window image. ④When using, you can adjust the work of the blackhead according to the skin condition of the face position. ⑤ After clicking "Video", the image transmitted by the camera of the instrument can be saved to the mobile phone. ⑥After clicking "Take Photo", the image transmitted by the instrument camera can be taken as a photo Save to phone. ⑦If you need to switch windows, you can click "AR" to switch windows. Nursing D ownload and install the APP (see APP download and installation steps for details) ②Connect the instrument through APP (see APP function description for details) ③ Clean the face before use, apply a hot compress or use a steamer to help pores Open, and the n use the blackhead ex port solutio n to soften the blackhead, you can easily suck out the blackhead. ④Choose the tip suitable for your needs, install it on the top of the instrument and on the palm or forearm Test the suction power. ⑤When in use, you can press the button to select the appropriate mode according to your skin condition. Soft: Soft mode; Normal: Normal mode; Strong: Strong mode. ⑥ Make sure that the sucti on head is close t o t he skin whe n using it, a nd t here must be n o gaps, ot herwise it will not form a vacuum Negative pressure. ⑦ K eep moving when using the instrument, the stay time in the same part should not ex ceed 3 seconds, Each use time does not ex ceed 5 minutes, enter the standby mode after 5 minutes, standby 10 minute No operation will automatically shut down. ⑧ After using, long press the power button to turn off the instrument, you can apply ice to the skin, Or use with pore astringent to calm the skin. ⑨Facial care is recommended 1-2 times a week. Charging ① Please charge the instrument before using it for the first time. ② Please use standard qualified D C5V/1A adapter for charging. ③ D uring charging, the power indicator white light flashes breathing. ④ When fully charged, the power indicator white light is always on. ⑤ When the power is low, the red indicator light flashes slowly. Please use it after fully charging. ※ If the connection has not started after 10 seconds of charging, please confirm whether the USB cable is light Poor micro-contact.…
Text truncated - open the document above for the full version.
C5266091_X8_Ed.1 Letter of Authorization Shenzhen Dianzhui Culture Technology Co., Ltd. Company: Shenzhen Dianzhui Culture Technology Co., Ltd. Address: 312, Block B, Baoyuan Huafeng Headquarter Economic Building , Xixiang Street, Baoan District, Shenzhen, China Product Name: Visual blackhead vacuum device Model Number: DZ03 FCC Identifier: 2AYJD-D Z03 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Jiayou Zhu Date: Dec.21.2020 Title: Project Manager Signature of applicant: 1/1
C5266091_X10_Ed.2 Shenzhen Dianzhui Culture Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: Dec.21.2020 Subject: Request for Confidentiality FCC ID: 2AYJD-D Z03 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. 1/1 C5266091_X10_Ed.2 Sincerely, Signature: Name: Jiayou Zhu Title: Project Manager 1/1
External Photos FCC ID: 2AYJD-DZ03
Model: DZ03 FCC ID: 2AYJD-DZ03 Label Location
Internal Photos FCC ID: 2AYJD-DZ03 ANT BK7231U MS83F1602S
Shenzhen CTB Testing Co., Ltd. FCC ID: 2AYJD-DZ03 Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2.4G WIFI: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.4127.5415.687.5±18.507.08 <52.198973.00YES 2.4427.3495.437.5±1 8.507.08<52.212603.00YES 2.4627.3935.497.5±18.507.08<52.221643.00 YES 802.11b Conclusion: For the max result : 2. 22164W/Kg ≤ FCC Limit 3.0 for 1g SAR.
Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201212008RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.netPage 1 of 49 TEST REPORT Compiled by: Reviewed by: Approved by: Arron Liu Bin Mei Rita Xiao / Director The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. Product Name: Visual Blackhead Vacuum Device FCC ID: 2AYJD-DZ03 Trademark: N/A Model Number: DZ03 Prepared For: Shenzhen Dianzhui Culture Technology Co., Ltd. Address: 312, Block B, Baoyuan Huafeng Headquarter Economic Building , Xixiang Street, Baoan District, Shenzhen, China Manufacturer: Shenzhen Dianzhui Culture Technology Co., Ltd. Address: 312, Block B, Baoyuan Huafeng Headquarter Economic Building , Xixiang Street, Baoan District, Shenzhen, China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: Floor 1&2, Building A, No. 26 of Xinhe Road, Xinqiao Street, Baoan District, Shenzhen China Sample Received Date: Dec. 11, 2020 Sample tested Date: Dec. 11, 2020 to Dec. 16, 2020 Issue Date: Dec. 16, 2020 Report No.: CTB201212008RFX Test Standards FCC Part15.247 ANSI C63.10:2013 Test Results PASS Remark: This is WIFI-2.4GHz band radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201212008RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 49 TABLE OF CONTENT Test Report Declaration Page 1. VERSION............................................................ 4 2. TEST SUMMARY ..................................................... 5 3. MEASUREMENT UNCERTAINTY ....................................... 6 4. PRODUCT INFORMATION AND TEST SETUP ........................... 7 4.1 Product Information ..................................................... 7 4.2 Test Setup Configuration ................................................ 7 4.3 Support Equipment ..................................................... 8 4.4 Channel List ........................................................... 8 4.5 Test Mode ............................................................. 8 4.6 Test Environment ....................................................... 8 5. TEST FACILITY AND TEST INSTRUMENT USED ......................... 9 5.1 Test Facility ............................................................ 9 5.2 Test Instrument Used ................................................... 9 6. AC POWER LINE CONDUCTED EMISSION .............................. 11 6.1 Block Diagram Of Test Setup............................................ 11 6.2 Limit ................................................................. 11 6.3 Test procedure ........................................................ 11 6.4 Test Result ........................................................... 13 7. RADIATED SPURIOUS EMISSION ..................................... 15 7.1 Block Diagram Of Test Setup............................................ 15 7.2 Limit ................................................................. 15 7.3 Test procedure ........................................................ 16 7.4 Test Result ........................................................... 17 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ............ 29 8.1 Block Diagram Of Test Setup............................................ 29 8.2 Limit ................................................................. 29 8.3 Test procedure ........................................................ 29 8.4 Test Result ........................................................... 30 9. COUDUCTED OUTPUT POWER....................................... 34 9.1 Block Diagram Of Test Setup............................................ 34 9.2 Limit ................................................................. 34 9.3 Test procedure ........................................................ 34 9.4 Test Result ........................................................... 35 10. 6DB OCCUPIED BANDWIDTH ........................................ 38 10.1 Block Diagram Of Test Setup .......................................... 38 10.2 Limit ................................................................ 38 10.3 Test procedure ....................................................... 38 10.4 Test Result .......................................................... 39 11. POWER SPECTRAL DENSITY ........................................ 42 11.1 Block Diagram Of Test Setup .......................................... 42 11.2 Limit ................................................................ 42 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201212008RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 49 11.3 Test procedure ....................................................... 42 11.4 Test Result .......................................................... 43 12. ANTENNA REQUIREMENT ........................................... 46 13. EUT PHOTOGRAPHS ................................................ 47 14. EUT TEST SETUP PHOTOGRAPHS ................................... 48 (Note: N/A means not applicable) Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201212008RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 49 1. VERSION Report N o. Issue Date Description Approved CTB201212008RFX Dec. 16, 2020 Original Valid Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201212008RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 5 of 49 2. TEST SUMMARY The Product has been tested according to the following specifications: Test Item Test Requirement Test method Result AC Power Line Conducted Emission 47 CFR Part 15 Subpart C Section 15.207 ANSI C63.10-2013 PASS Radiated Spurious emissions 47 CFR Part 15 Subpart C Section 15.205/15.209 ANSI C63.10-2013 PASS …
Text truncated - open the document above for the full version.
Radiated Emission Below 1G Above 1G FCC ID: 2AYJD-DZ03 Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 5.68 mW |
Visible Baby Nasal Aspirator
Equipment Class
DTS - Digital Transmission System
VISIBLE EAR WAX REMOVER
Equipment Class
DTS - Digital Transmission System
Visual Blackhead Vacuum Device
Equipment Class
DTS - Digital Transmission System