Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Warning Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Shenzhenshi Juhao Trading Co., Ltd. Agent Authorization Letter (2020/12/31) MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Global United Technology Services Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature : Client’s name / title : Liangxian / Manager Contact information / address: Room 138-148, Gate 2, Building 3, Phase II, Handmade Culture Street, Reservoir Road, Bantian Street, Longgang District, Shenzhen, China
Shenzhenshi Juhao Trading Co., Ltd. Long Term Confidentiality Request Letter (2020-12-31) MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Four in One Fast Wireless Charger / Z60 / 2AYJT-Z60 ) To Whom It May Concern: - This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature : Client’s name / title : Liangxian / Manager Contact information / address: Room 138-148, Gate 2, Building 3, Phase II, Handmade Culture Street, Reservoir Road, Bantian Street, Longgang District, Shenzhen, China
Report No.: GTS202012000107 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 21 of 23 9 EUT Constructional Details Report No.: GTS202012000107 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 22 of 23
2cm Model: Four in One Fast Wireless Charger FCC ID: 2AYJT-Z60 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may causeundesired operation. Label Location 1cm
Report No.: GTS202012000107 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 23 of 23 ------End------ Antenna
Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 4 FCC ID: 2AYJT-Z60 RF Exposure Evaluation 1 Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging Apps v03 2 Requirements According to the item 5 of KDB 680106 D01v03: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Remark: Meet all the above requirements. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 4 3 Test Setup 4 Test Procedure 1) The RF exposure test was performed in anechoic chamber. 2) The measurement probe was placed at test distance (15 cm from all sides and 20 cm from the top) which is between the edge of the charger and the geometric center of probe. 3) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E) were completed. 4) The EUT was measured according to the dictates of KDB 680106 D01v03. Remark:The EUT’s test position A, B, C, D and E is valid for the E and H field measurements. Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 4 5 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) Exposure Level Tester Narda ELT-400 N-0231 June. 25 2020 June. 24 2021 Magnetic field probe 100cm 2 Narda ELT probe 100cm 2 M0675 June. 25 2020 June. 24 2021 6 Test Result E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (V/m) 0.115-0.205 1.15 2.36 0.79 0.68 614 E-Filed Strength at 20 cm from the top of the EUT (V/m) Frequency Range (MHz) Test Position E Limits (V/m) 0.115-0.205 1.25 614 H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D 50% Limits (A/m) Limits (A/m) 0.115-0.205 0.63 0.72 0.59 0.42 0.815 1.63 H-Filed Strength at 20 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E 50% Limits (A/m) 50% Limits (A/m) Limits (A/m) 0.115-0.205 0.38 0.815 0.815 1.63 Test Engineer: Reviewer: Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 4 7 Test Set-up Photo
Global United Technology Services Co., Ltd. Report No.: GTS202012000107 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 23 TEST REPORT Applicant: Shenzhenshi Juhao Trading Co., Ltd. Address of Applicant: Room 138-148, Gate 2, Building 3, Phase II, Handmade Culture Street, Reservoir Road, Bantian Street, Longgang District, Shenzhen, China Manufacturer/Factory: Shenzhenshi Juhao Trading Co., Ltd. Address of Manufacturer/Factory: Room 138-148, Gate 2, Building 3, Phase II, Handmade Culture Street, Reservoir Road, Bantian Street, Longgang District, Shenzhen, China Equipment Under Test (EUT) Product Name: Four in One Fast Wireless Charger Model No.: Z60 FCC ID: 2AYJT-Z60 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Date of sample receipt: December 09, 2020 Date of Test: December 09- December 15, 2020 Date of report issued: December 15, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202012000107 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 23 2 Version Version No. Date Description 00 December 15 Original Prepared By: Date: December 15, 2020 Project Engineer Check By: Date: December 15, 2020 Reviewer Report No.: GTS202012000107 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 23 3 Contents Page 1 COVER PAGE .............................................................................................................................................1 2 VERSION ...................................................................................................................................................2 3 CONTENTS ...............................................................................................................................................3 4 TEST SUMMARY ......................................................................................................................................4 4.1 MEASUREMENT UNCERTAINTY .............................................................................................................4 5 GENERAL INFORMATION .......................................................................................................................5 5.1 GENERAL DESCRIPTION OF EUT ..........................................................................................................5 5.2 TEST MODE .........................................................................................................................................6 5.3 DESCRIPTION OF SUPPORT UNITS ........................................................................................................6 5.4 TEST FACILITY ....................................................................................................................................6 5.5 TEST LOCATION ..................................................................................................................................6 5.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ..........................................................................6 6 TEST INSTRUMENTS LIST ......................................................................................................................7 7 TEST RESULTS AND MEASUREMENT DATA .......................................................................................9 7.1 ANTENNA REQUIREMENT: .....................................................................................................................9 7.2 CONDUCTED EMISSIONS ....................................................................................................................10 7.3 SPURIOUS EMISSION .........................................................................................................................13 7.4 20DB OCCUPY BANDWIDTH ...............................................................................................................18 8 TEST SETUP PHOTO .............................................................................................................................19 9 EUT CONSTRUCTIONAL DETAILS .......................................................................................................21 Report No.: GTS202012000107 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 23 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203 Pass AC Power Line Conducted Emission 15.207 Pass Spurious Emission 15.209(a)(f) Pass 20dB Bandwidth 15.215 Pass Pass: The EUT complies with the essential requirements in the standard. 4.1 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes Radiated Emission 30MHz-200MHz 3.8039dB (1) Radiated Emission 200MHz-1GHz 3.9679dB (1) Radiated Emission 1GHz-18GHz 4.29dB (1) Radiated Emission 18GHz-40GHz 3.30dB (1) AC Power Line Conducted Emission 0.15MHz ~ 30MHz 3.44dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Report No.: GTS202012000107 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, N…
Text truncated - open the document above for the full version.
Test Setup Photo
2nd Floor, Block No.2, Laodong Industrial Zone · Shenzhen, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |