FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dongguan Anhong Electronic Technology Co.,Ltd/
  3. 2AYKP-ABM200

2AYKP-ABM200Security & Protection Camera

Dongguan Anhong Electronic Technology Co.,Ltd
Security & Protection Camera - FCC ID 2AYKP-ABM200 - Dongguan Anhong Electronic Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jan 11, 2021
Application Purpose
Original Equipment
Date of Application
Jan 11, 2021
Equipment Note
Security & Protection Camera
Frequency Range
2402.00000000 - 2480.00000000
Company
Dongguan Anhong Electronic Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment

Attestation Statements

Modeldifferencedeclarationletter DifferencesDescription WeDongguanAnhongElectronicTechnologyCo.,Ltdstate: Product:Security&ProtectionCamera ModelName ABM100/ABM101/ABM100S/ABM101S/ABM200 /ABM201/ABM200S/ABM201S/ABM300/ABM40 0/ABM500/ABM501/ABM600/ABM700/ABM800/ ABM900/ADC100/ADC200/ADC300/ADC400/AD C500/ADC600/ADC700/ADC800/ADC900/ADB1 00/ADB200/ADB300/ADB400/AHC100/AHC200/ AHC300/AHC400/AHC500/AHC600/ AHC700/AHC800/AHC900/ Theaboveproductwithsamecircuit,PCBlayout,electricalparts,materialsandwiring structures,Appearanceshape,thematerialsofdecorativeaccessoriesissame,only differentcolor, Signatory Date:12-30-2020 <Signature> Name:RoseRen Title:SalesManager Company:DongguanAnhongElectronicTechnologyCo.,Ltd Address:Floor2,No.19,DezhongSciencePark,ShahuVillage,TangxiaTown,Dongguan, Guangdong,China.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization DongguanAnhongElectronicTechnologyCo.,Ltd Company:DongguanAnhongElectronicTechnologyCo.,Ltd Address:Floor2,No.19,DezhongSciencePark,ShahuVillage,TangxiaTown, Dongguan,Guangdong,China. ProductName:Security&ProtectionCamera ModelNumber:ABM200 FCCIdentifier:2AYKP-ABM200 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:RoseRenDate:December30,2020 Title:SalesManager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 DongguanAnhongElectronicTechnologyCo.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:December30,2020 Subject:RequestforConfidentiality FCCID:2AYKP-ABM200 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:RoseRen Title: SalesManager

External Photos

Page1of3ReportNo.:FCS202012033 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202012033 Photo3 Photo4 Page3of3ReportNo.:FCS202012033 Photo5 Photo6

ID Label/Location Info

LabelandLabelLocation FCCID:2AYKP-ABM200 L*W:10mm*7mm whitefontonaBlacklabel

Internal Photos

Page1of5ReportNo.:FCS202012033 Photo1 Photo2 Page2of5ReportNo.:FCS202012033 Photo3 Antenna Photo4 Page3of5ReportNo.:FCS202012033 Photo5 Photo6 Page4of5ReportNo.:FCS202012033 Photo7 Photo8 Page5of5ReportNo.:FCS202012033 Photo9

Test Report

FCCTestReport ReportNo:FCS202012033W01 Issuedfor Applicant: DongguanAnhongElectronicTechnologyCo.,Ltd Address: Floor2,No.19,DezhongSciencePark,ShahuVillage, TangxiaTown,Dongguan,Guangdong,China. ProductName: Security&ProtectionCamera BrandName: Ainhyzic ModelName: ABM200 SeriesModel: ABM100/ABM101/ABM100S/ABM101S/ABM200/ABM201/A BM200S/ABM201S/ABM300/ABM400/ABM500/ABM501/AB M600/ABM700/ABM800/ABM900/ADC100/ADC200/ADC30 0/ADC400/ADC500/ADC600/ADC700/ADC800/ADC900/AD B100/ADB200/ADB300/ADB400/AHC100/AHC200/AHC300/ AHC400/AHC500/AHC600/AHC700/AHC800/AHC900/ FCCID: 2AYKP-ABM200 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page2of36ReportNo.:FCS202012033W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:DongguanAnhongElectronicTechnologyCo.,Ltd Address ...................................... : Floor2,No.19,DezhongSciencePark,ShahuVillage,Tangxia Town,Dongguan,Guangdong,China. Manufacture'sName ................ :DongguanAnhongElectronicTechnologyCo.,Ltd Address ...................................... : Floor2,No.19,DezhongSciencePark,ShahuVillage,Tangxia Town,Dongguan,Guangdong,China. ProductDescription ProductName...........................:Security&ProtectionCamera BrandName.............................:Ainhyzic ModelName .............................. :ABM200 SeriesModel .............................. : ABM100/ABM101/ABM100S/ABM101S/ABM200/ABM201/ABM200 S/ABM201S/ABM300/ABM400/ABM500/ABM501/ABM600/ABM70 0/ABM800/ABM900/ADC100/ADC200/ADC300/ADC400/ADC500/ ADC600/ADC700/ADC800/ADC900/ADB100/ADB200/ADB300/AD B400/AHC100/AHC200/AHC300/AHC400/AHC500/AHC600/ AHC700/AHC800/AHC900/ TestStandards .......................... :FCCRulesandRegulationsPart15SubpartC,Section249 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentundertest (EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest..................................: Date(s)ofperformanceoftests . :21Dec,2020~30Dec,2020 DateofIssue ................................. :30Dec,2020 TestResult.....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (KaitChen) Page3of36ReportNo.:FCS202012033W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS5 1.1TESTFACTORY6 1.2MEASUREMENTUNCERTAINTY6 2.GENERALINFORMATION7 2.1GENERALDESCRIPTIONOFTHEEUT7 2.2DESCRIPTIONOFTHETESTMODES9 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS10 2.4EQUIPMENTSLIST11 3CONDUCTEDEMISSIONMEASUREMENT12 3.1LIMIT12 3.2TESTPROCEDURE12 3.3TESTSETUP13 3.4TESTRESULTS14 4.RADIATEDEMISSIONMEASUREMENT17 4.1LIMIT17 4.2TESTPROCEDURE18 4.3TESTSETUP19 4.4TESTRESULTS20 5.BANDEDGETEST27 5.1LIMIT27 5.2TESTPROCEDURE27 5.3TESTSETUP28 5.4TESTRESULTS29 6.20DBBANDWIDTHTEST33 6.1LIMIT33 6.2TESTPROCEDURE33 6.3TESTSETUP33 6.4TESTRESULTS34 7.ANTENNAREQUIREMENT36 7.1STANDARDREQUIREMENT36 7.2EUTANTENNA36 Page4of36ReportNo.:FCS202012033W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RevisionHistory Rev.IssueDateEffectPageContents 0030Dec,2020AllInitialIssue Page5of36ReportNo.:FCS202012033W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.SUMMARYOFTESTRESULTS FCCPart15.249,SubpartC Standard Section TestItemJudgmentRemark 15.207ConductedEmissionPASS-- 15.205(a),15.209(a), 15.249(a),15.249(c) RadiatedSpuriousEmissionPASS-- 15.209FieldstrengthoffundamentalPASS 15.249(d)BandEdgeEmissionPASS-- 15.215(c)20dBBandwidthPASS-- 15.203AntennaRequirementPASS-- NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport (2)AlltestsareaccordingtoANSIC63.10-2013 Page6of36ReportNo.:FCS202012033W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.1TESTFACTORY CompanyName:FluxComplianceServiceLaboratory Address: Room105FloorBaohaoTechnologyBuilding1NO.15Gongye WestRoadHi-TechIndustrial,SongshanlakeDongguan Telephone:+86-769-27280901 Fax:+86-769-27280901 FCCTestFirmRegistrationNumber:514908 Designationnumber:CN0127 A2LAaccreditationnumber:5545.01 1.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedona standarduncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceof approximately95%. No.ItemUncertainty 1RFoutputpower,conducted±0.71dB 2UnwantedEmissions,conducted±2.98dB 3ConductedEmission(9KHz-150KHz) ±4.13dB 4ConductedEmission(150KHz-30MHz) ±4.74dB 5Allemissions,radiated(<1G)30MHz-1000MHz ±3.2dB 6Allemissions,radiated(1GHz-18GHz) ±3.66dB 7Allemissions,radiated(18GHz-40GHz) ±4.31dB Page7of36ReportNo.:FCS202012033W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 2.GENERALINFORMATION 2.1GENERALDESCRIPTIONOFTHEEUT ProductNameSecurity&ProtectionCamera TradeNameAinhyzic ModelNameABM200 SeriesModel ABM100/ABM101/ABM100S/ABM101S/ABM200/AB M201/ABM200S/ABM201S/ABM300/ABM400/ABM5 00/ABM501/…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of2ReportNo.:FCS202012033 Above1GHzforradiatedemissiontestsetup Blow1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202012033 Conductionemissiontestingdevice

Contact Information

Applicant

Rose Ren(Sales Manager)
[email protected]13682455928Fax: 13682455928

Technical Contact

Flux Compliance Service LaboratoryKait Chen
[email protected]86-769-27280901

Dongguan · China

Non-Technical Contact

Flux Compliance Service LaboratoryKait Chen
[email protected]86-769-27280901

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from Dongguan Anhong Electronic Technology Co.,Ltd

Video Walkie Talkies - FCC ID 2AYKP-ABM660 - Dongguan Anhong Electronic Technology Co.,Ltd
2AYKP-ABM660

Video Walkie Talkies

Jul 24, 2026

Equipment Class

DTS - Digital Transmission System
2AYKP-ABM720S

Baby Monitor

Sep 05, 2025

Equipment Class

DTS - Digital Transmission System