Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Compliance Statement This device complies with Part 15 fo the FCC Rules. The operation is subject to the following two conditions: (1) This device may not cause harmful interference,and (2) This device must accept any interference received,including interference that may cause undesired operation. Note:This equipment has been tested and found to comply with the limits for a class B digital device,pursuant to Part 15 of the FCC Rules.These equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular installation.If this equipment does cause interference to radio of television reception,which can be determined by turning the equipment off and then on,the user is encouraged to try to correct the interference by one or more of the following Measures: “Reorient or relocate the receiving antenna. “Increase the separation between the equipment and receiver. “Connect the equipment to a different outlet so that the equipment and receiver are on different branch circuits. “Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC ID:2AYOQ-TLV6
SPIRIT LLC Agent Authorization Company: SPIRIT LLC Address: 1400 NW 159TH ST, BAY 101 MIAMI GARDENS, FL 33169 Product Name: PORTABLE PARTY SPEAKER Trade Mark: DS18 Model Number(s): TLV6 FCC ID: 2AYOQ-TLV6 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2021-01-29 Name: Sasha Susterman Title: General Manager/Biz. Development Company: SPIRIT LLC
SPIRIT LLC Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2021-01-29 Subject; Request for Confidentiality FCC ID: 2AYOQ-TLV6 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Sasha Susterman Title: General Manager/Biz. Development
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 EXTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.7 Fig.8
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 INTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.7 Fig.8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.9 Fig.10 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.11 Fig.12 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.13 Fig.14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.15 Fig.16 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.17 Fig.18 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.19 Fig.20 BT Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.21 Fig.22 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.23 Fig.24 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.25 Fig.26 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Fig.27
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYOQ-TLV6 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 4 FCC RF Exposure Evaluation 1. Product Information FCC ID 2AYOQ-TLV6 Product name PORTABLE PARTY SPEAKER Model number TLV6 Power supply Input: 110-240V~, 50/60Hz, 60W DC 12V by Rechargeable Valve Regulated Lead-Acid Battery, 4Ah Modulation Type GFSK, π/4-DQPSK, 8-DPSK for Bluetooth V5.0(DSS) GFSK for Bluetooth V5.0(DTS) Antenna Type PCB Antenna Antenna Gain -0.58dBi(Max.) Hardware version / Software version / FCC Operation frequency 2402MHz ~ 2480MHz Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Devices 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYOQ-TLV6 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 4 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information Artemis Antenna can only use antennas certificated as follows provided by manufacturer; Internal Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Note Antenna PCB Antenna 2402MHz ~ 2480MHz 2412MHz-2462MHz -0.58dBi BT WIFI Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYOQ-TLV6 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 4 6. Conducted Power < BT Max Conducted Power > Mode Channel Frequency(MHz) Max Conducted Power (dBm) GFSK 0 2402 1.014 39 2441 0.493 78 2480 -0.032 π/4DQPSK 0 2402 1.004 39 2441 0.503 78 2480 -0.073 8DPSK 0 2402 1.056 39 2441 0.486 78 2480 -0.066 < BT LE Max Conducted Power > Mode Channel Frequency(MHz) Max Conducted Power (dBm) GFSK 0 2402 1.332 19 2440 -0.358 39 2480 -2.356 7. Manufacturing Tolerance <BT> GFSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 1.0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 π/4DQPSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 1.0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 8DPSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 1.0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 <BT LE> GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 1.0 0 -2.0 Tolerance ±(dB) 1.0 1.0 1.0 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYOQ-TLV6 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 4 8. Measurement Results 8.1 Standalone MPE As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance,…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 1 of 14 Appendix B RF Test Data for BLE V5.0(BDR/EDR) (Conducted Measurement) Product Name: PORTABLE PARTY SPEAKER Trade Mark: DS18 Test Model: TLV6 Environmental Conditions Temperature: 22.3 C Relative Humidity: 53.4% ATM Pressure: 100.0 kPa Test Engineer: Kay Hu Supervised by: Li Huan B.1 Duty Cycle Test Mode Test Channel Ant Duty Cycle[%] Verdict BT LE 2440 Ant1 100 PASS #im grbble1hchnnav SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 2 of 14 B.2 Maximum Conducted Peak Output Power Mode Channel Conduct Peak Power[dBm] Limit [dBm] Verdict BT LE LCH 1.332 30 PASS BT LE MCH -0.358 30 PASS BT LE HCH -2.356 30 PASS Test Graphs LCH MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 3 of 14 HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 4 of 14 B.3 Maximum Power Spectral Density Mode Channel PSD [dBm/3KHz] Limit [dBm/3KHz] Verdict BT LE LCH -13.745 8 PASS BT LE MCH -15.378 8 PASS BT LE HCH -17.425 8 PASS Test Graphs LCH MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 5 of 14 HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 6 of 14 B.4 6dB Bandwidth Mode Channel 6dB Bandwidth [MHz] Limit [MHz] Verdict BT LE LCH 0.6958 ≥0.5 PASS BT LE MCH 0.6843 ≥0.5 PASS BT LE HCH 0.6862 ≥0.5 PASS Test Graphs LCH MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 7 of 14 HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 8 of 14 B.6 RF Conducted Spurious Emissions Mode Channel Pref [dBm] Max. Level [dBm] Limit [dBm] Verdict BT LE LCH 1.19 -37.011 -18.810 PASS BT LE MCH -0.515 -37.021 -20.515 PASS BT LE HCH -2.529 -37.474 -22.529 PASS BT LE_LCH_Graphs Pref/BT LE/LCH Puw/BT LE/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 9 of 14 BT LE_MCH_Graphs Pref/BT LE/MCH Puw/BT LE/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 10 of 14 BT LE_HCH_Graphs Pref/BT LE/HCH Puw/BT LE/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 11 of 14 B.7 Band-edge for RF Conducted Emissions Mode Channel Carrier Power[dBm] Max.Spurious Level [dBm] Limit [dBm] Verdict BT LE LCH 1.205 -48.325 -18.8 PASS BT LE HCH -2.511 -49.375 -22.51 PASS Test Graphs LCH HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 12 of 14 B.8 Restrict-band band-edge measurements Test Mode Test Chann el Ant Freq. Power [dBm] Gain Ground Factor E [dBuV/m] Detector Limit [dBuV/ m] Verdi ct BT LE 2402 Ant1 2310.0 -43.71 2.0 0 51.55 PEAK 74 PASS Ant1 2310.0 -53.53 2.0 0 41.73 AV 54 PASS Ant1 2390.0 -42.96 2.0 0 52.30 PEAK 74 PASS Ant1 2390.0 -53.21 2.0 0 42.05 AV 54 PASS 2480 Ant1 2483.5 -42.83 2.0 0 52.43 PEAK 74 PASS Ant1 2483.5 -52.74 2.0 0 42.51 AV 54 PASS Ant1 2500.0 -43.01 2.0 0 52.25 PEAK 74 PASS Ant1 2500.0 -52.52 2.0 0 42.74 AV 54 PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 13 of 14 Restrict-band band-edge measurements_BT LE_2402_Ant1_PEAK Restrict-band band-edge measurements_BT LE_2402_Ant1_AV SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 Report No.: LCS210111014AEB Page 14 of 14 Restrict-band band-edge measurements_BT LE_2480_Ant1_PEAK Restrict-band band-edge measurements_BT LE_2480_Ant1_AV
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYOQ-TLV6 Report No.: LCS210111014AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 33 FCC TEST REPORT For SPIRIT LLC PORTABLE PARTY SPEAKER Test Model: TLV6 Prepared for : SPIRIT LLC Address : 1400 NW 159TH ST, BAY 101 MIAMI GARDENS, FL 33169 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : January 12, 2021 Number of tested samples : 1 Serial number : Prototype Date of Test : January 12, 2021 ~ January 19, 2021 Date of Report : January 21, 2021 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYOQ-TLV6 Report No.: LCS210111014AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 33 FCC TEST REPORT FCC CFR 47 PART 15 C (15.247) Report Reference No. ................. : LCS210111014AEB Date of Issue ................................... : January 21, 2021 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : SPIRIT LLC Address ........................................... : 1400 NW 159TH ST, BAY 101 MIAMI GARDENS, FL 33169 Test Specification Standard.......................................... : FCC CFR 47 PART 15 C (15.247) Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : PORTABLE PARTY SPEAKER Trade Mark .......................................................................................................................................... : DS18 Test Model .......................................................................................................................................... : TLV6 Ratings ................................................................................................................................................ : Input: 110-240V~, 50/60Hz, 60W DC 12V by Rechargeable Valve Regulated Lead-Acid Battery, 4Ah Result ........................................... : Positive Compiled by: Supervised by: Approved by: Cherry Chen/ Administrators Jin Wang/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYOQ-TLV6 Report No.: LCS210111014AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 33 FCC -- TEST REPORT Test Model........................... : TLV6 EUT......................................... : PORTABLE PARTY SPEAKER Applicant............................... : SPIRIT LLC Address.................................. : 1400 NW 159TH ST, BAY 101 MIAMI GARDENS, FL 33169 Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Guangzhou Jie Li Electron Co., Ltd Address................................... : Block A, No.5, Xinke Kejia Yuanxing Rd., Jiahe Street, Baiyun District, Guangzhou, China Telephone............................... : / Fax.......................................... : / Factory................................... : / Address................................... : / Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS210111014AEB January 21, 2021 Date of issue SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYOQ-TLV6 Report No.: LCS210111014AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 33 Revision History Revision Issue Date Revisions Revised By 000 January 21, 2021 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYOQ-TLV6 Report No.: LCS210111014AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 33 TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................................................................. 6 1.1. DESCRIPTION OF DEVICE (EUT) ....................................................................................................................................... 6 1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS ......................................................................................................... 6 1.3. EXTERNAL I/O C…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 _______________________________________________________________________________________________ TEST SETUP PHOTOGRAPHS Photo of Radiated Emissions Measurement Below 1 GHz Above 1 GHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYOQ-TLV6 _______________________________________________________________________________________________ Power Line Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.40 mW |
Amplifier
Equipment Class
DTS - Digital Transmission SystemAmplifier
Equipment Class
DTS - Digital Transmission System5.3 Bluetooth Streaming Audio Receiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
OUTDOOR SPEAKER SOUNDBAR
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Audio Receiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter