
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1/62/6 Tools âDD200prodiamondcorerig,vacuumbase(P/N onHiltiwebsite:Item#3423950). âĂ130mmcrown â10-litreportablewatersupplytank(P/NonHilti website:Item#365595)+ExtraportableWaterTank âVacuumCleaner âAppActivationToolonAndroidmobilephone âRFIDdevice(DOTR-900fromKCTNS)andselfie stick Materials âMortarMapegroutSV Sensor installation position Installationstepbystep U-SpotDUOinstallation U-SpotDUOinstallation ! Gettingstarted... âąActivationToolinstalledonAndroidSmartphone(contact [email protected]) âąActivationToolusernameandpasswordavailable âąCheck that the network is configured in the Fastprk web platform âąEnsure that the LoRa coverage is ensured in the sensorsâ installation area 1.Makeahole75mmdeepwithacrownof130mmĂ. 2.Cleananddrytheholefromdust,debrisandwater. 3.PreparetheMapegroutSVfastmortar. 4.Foreachofthesensors,filltheholewithenoughmortartoensure thatthemortartakesupallthespacebetweentheholeandthesensor (approximately250mlpersensor).Foroptimalinstallation,asurplusof mortarmustspillovertheholewhenthesensorisinserted 5.Cleanthemortarthatoverflowedfromtheedgeofthehole. 6.Placeaweightoverthesensorandwaituntildries.Werecommend lettingthemortardryfor15minutes. âąSensoredgemustbeinlinewiththepavement âąSensor should be completely flush within the pavement 7.Takepicturesoftheinstalledsensors,about70%-80%ofthe sensors. 8.Takeapicture(ifpossiblepanoramic)toensuretherearenocars nearby. 9.ActivatethesensorwiththeActivationtoolfollowingtheprocedure describeinthenextpages. 3/6 4/6 U-SpotDUOsensoractivation Oncethesensorisphysicallyinstalled,youcanproceedwiththe activationusingtheRFIDToolandtheActivationToolApp. 1.Preparetheenvironment âMakesurethatthephoneandRFIDdevicesarefullycharged. âOnthemobilephone,setupthecorrectdate/hourandtimezone. âOnthemobilephone,activatelocationandnetworkservices(GPS,WiFiorGSM). âOnthemobilephone,activateBluetooth. âOnthemobilephone,disablethescreenstandbytime. U-SpotDUOactivation U-SpotDUOactivation 2.Basicstep-by-stepflow a)LoginintheActivationToolApp c)SetuptheApp TherearetwowaysofconfiguringtheActivationapp:oneismanually(detailedsteps below),orbyimportingaspecificconfigfileprovidedbyUrbiotica. b)ConnectwiththeRFIDdevice âPowerONtheRFIDdevice. âFromthemobilephoneopentheActivation app,gotothesidebarmenufromtheleftside,and choosetheoptionâPairwithRFIDâtoconnectthe RFIDdevice,andcheckthattheconnectionis successful. âRFIDpassword:1234 âOption1:Manualconfiguration OntheâCurrentconfigfileâfromthemainmenu youcancheckandeditmultipleoptionsasthe LoRaregion,thedefaultnodepasswordand nodeactivationparameters. CheckthatâNodeisactiveâisenabled. NOTE:NodespasswordsareNOTstoredby Urbiotica.Ifchanged,youareresponsiblefor managingthisinformationonyourownway. âRadiosettings FromthemenugotoâCurrentconfig fileâ>âLoRaRegionâ,checkthatthe correctLoRaRegionissetdepending oftheradiofrequencythatisgoing tobeused. NOTE: Keep in mind that the Network key must be obtained from the LoRaWAN network provider. âąRadioSettingforLoRaWANEuropeandFCC(LoRaWANnetwork) SelecttheLoRaWANfrequencytypethatisgoingtobeusedtocommunicate(foryour region)andwritedowntheLoRaWANnetworkkeyintheâLoraNetworkKeyâfield. âąRadioSettingforLoRaEuropeandFCCLoRa(U-BoxLoRagateways) Select the LoRa frequency type that is going to be used to communicate (for your region), and do NOT modified the network key in the âLora Network Keyâ field. To use LoRa frequencies a U-Box LoRa gateway must be installed. 5/6 6/6 U-SpotDUOactivation U-SpotDUOactivation d)Activatethesensor Oneachsensor,withthenextorderofactions,doingitfromthetopfrontofthe sensor. Thiswillpoweronandsendtheconfigurationpreviouslyselectedtothesensor andsynchronizeitwiththeFastprkplatform. âDiscover:showSensorIDandStatus âGetalldata:retrievetheconfigurationfromthesensor âSetconfiguration:applycurrentconfigurationtothenode âManualSync:synchronizesensorinformationlogfileswiththeFastprkbackend platform âOption2:Importaconfigurationfile FromthesidebarmenugotoâChooseconfigfileâ>âBrowsefileâ,toloadaspecific configurationfile,ifrequired. IfyouareexperiencingissuesontheActivationprocess,pleaseusetheâSharelogâ optiontosendtheconfigurationlogtoUrbioticatechnicalsupportteamforfurther assistance. NOTE: It is very important that there are no parked cars or metallic elements (tools, barriers, etc...) near the sensor during the activation as its first magnetic calibration value will be defined at that moment.
FCB011_02 //DEKRA Testing and Certification, S.A.U. // www.dekra-product-safety.com/wireless Date: 17/02/2021 Barcelona Smart Technologies, S.L., C/ Joaquim Molins 5, 4o 1a, 08028 Barcelona España Ref: Agent letter for FCC ID: 2AYS6-U-SPOT-DUO We, Barcelona Smart Technologies s.l., C/ Joaquim Molins, 5, 4Âș 4ÂȘ Barcelona 08028, Spain Mr. Josep Maria Torras Carrera hereby authorize DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa Severo Ochoa, 2 & 6 | 29590 | MĂĄlaga, Spain Mr. Alejandro Vega GarcĂa, e-mail: [email protected], Phone: +34 952 619 310 to act as our agent in the preparation of this application for equipment certification, including the signing of all documents relating to these matters. The present authorization considers the development of documents on behalf of the client, written under his own letterhead and related to the necessary information to be provided on his behalf to complete the certification process. We also hereby certify that neither we nor any party to this application are subject to a denial of U.S. Federal benefits, which include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862 because of conviction for possession or distribution of controlled substance. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by DEKRA Testing and Certification, S.A.U., still resides with us. This agreement expires one year from the current date. Sincerely, 17/2/2021 X Signat per: TORRAS CARRERA JOSEP MARIA - 44011390Q By: Josep Maria Torras Carrera Title: CEO Company: Barcelona Smart Technologies Telephone: +34 931691730 e-mail: [email protected]
FCB012_02 //DEKRA Testing and Certification, S.A.U. // www.dekra-product-safety.com/wireless Date: 17/02/2021 Barcelona Smart Technologies, S.L., C/ Joaquim Molins 5, 4o 1a, 08028 Barcelona,España Ref: Confidentiality request for FCC ID: 2AYS6-U-SPOT-DUO To whom it may concern: Pursuant to §0.457(d)(1)(ii) and §0.459 of the Commissionâs Rules (47 C.F.R.) and §552 (b)(4) of the Freedom of Information Act, Barcelona Smart Technologies S.L. hereby request requests that a part of the subject FCC application be held confidential to avoid release of sensitive information of the product to the public. For the product stated above, we request that the following information be withheld from public disclose: Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Internal Photos Short Term Permanent Operation Description Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Userâs Manual Permanent Confidentiality: The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to us and provide unjustified benefits to our competitors. Short-Term Confidentiality: We hereby request short-term confidentiality for the product stated above to avoid premature release of sensitive information prior to marketing or release of the product to the public. Release date of short term confidentiality is: 45 days from grant date marked 90 days from grant date marked 135 days from grant date marked 180 days from grant date marked Specific date: We are also aware that we are responsible to notify DEKRA Testing and Certification, S.A.U. in the event information regarding the product or the product is made available to the public. DEKRA Testing and FCB012_02 //DEKRA Testing and Certification, S.A.U. // www.dekra-product-safety.com/wireless Certification, S.A.U. will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, 17/2/2021 X Signat per: TORRAS CARRERA JOSEP MARIA - 44011390Q By: Josep Maria Torras Carrera Title: CEO Company: Barcelona Smart Technologies Telephone: +34 931691730 e-mail: [email protected]
Marking Sticker An sticker is placed on the base of the product. Sticker detail Sticker size: 60mm x 36mm
DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29 507 456 Report No: 57721REM.002 2021-03-10 Test report No: NIE: 57721REM.002 Test report FCC Rules and Regulations CFR 47, Part 15, Subpart B (10-1-19 Edition) & ICES-003 Issue 7 (October 2020) (*) Identification of item tested Wireless battery powered parking sensor (*) Trademark UrbiĂłtica (*) Model and /or type reference U-SPOT-DUO Other identification of the product HW Version: SPD.HW.20.10 SW Version: SPD.FW.1.11 FCC ID: 2AYS6-U-SPOT-DUO (*) Features LoRa communications. Manufacturer Barcelona Smart Technologies S.L. C/ Joaquim Molins 5, 4o 4a Barcelona 08028. Spain. Test method requested, standard FCC Rules and Regulations CFR 47, Part 15, Subpart B (10-1-19 Edition) & ICES-003 Issue 7 (October 2020) Summary IN COMPLIANCE Approved by (name / position & signature) Rafael LĂłpez EMC Consumer & RF Lab. Manager Date of issue 2021-03-10 Report template No FDT08_23 (*) âData provided by the clientâ DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29 507 456 Report No: 57721REM.002 Page 2 of 17 2021-03-10 Index ACRONYMS ................................................................................................................................................................. 3 COMPETENCES AND GUARANTEES ....................................................................................................................... 3 GENERAL CONDITIONS ............................................................................................................................................. 4 UNCERTAINTY ............................................................................................................................................................ 4 DATA PROVIDED BY THE CLIENT ............................................................................................................................ 4 USAGE OF SAMPLES ................................................................................................................................................. 5 TEST SAMPLE DESCRIPTION ................................................................................................................................... 6 IDENTIFICATION OF THE CLIENT ............................................................................................................................. 7 TESTING PERIOD AND PLACE .................................................................................................................................. 7 DOCUMENT HISTORY ................................................................................................................................................ 7 ENVIRONMENTAL CONDITIONS ............................................................................................................................... 8 REMARKS AND COMMENTS ..................................................................................................................................... 9 TESTING VERDICTS ................................................................................................................................................... 9 LIST OF EQUIPMENT USED DURING THE TEST ..................................................................................................... 9 SUMMARY .................................................................................................................................................................. 10 APPENDIX A: TEST RESULTS ................................................................................................................................. 11 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29 507 456 Report No: 57721REM.002 Page 3 of 17 2021-03-10 Acronyms Acronym ID Acronym Description Avg Radiated Average Level Avg Conducted Average Level Az Azimuth CPL Zones / Coupling Cables Code EMC Test Code Freq Frequency Freq Rng Frequency Range H Height Line Conducted Emissions - Tested Line MP Measurement Point Max Conducted Maximum Level MaxPeak Radiated Maximum Peak Level OM Operation Mode Pol Polarization QuasiPeak Conducted Quasi Peak Level QuasiPeak Radiated Quasi Peak Level S/ Sample V Verdict Volt Immunity Lvl Voltage Immunity Severity Level Volt Immunity Type Voltage Immunity Type Competences and guarantees DEKRA Testing and Certification S.A.U. is a testing laboratory accredited by the National Accreditation Body (ENAC -Entidad Nacional de AcreditaciĂłn), to perform the tests indicated in the Certificate No. 51/LE 147. In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification S.A.U. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification S.A.U. at the time of performance of the test. DEKRA Testing and Certification S.A.U. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Testing and Certification S.A.U. DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ SeveroâŠ
Text truncated - open the document above for the full version.
DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa, c/ Severo Ochoa nÂș 2 · 29590 Campanillas · MĂĄlaga · España C.I.F. A29 507 456 Report No: 57721REM.002 2021-02-15 Photographs
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 902.3 MHz - 927.26 MHz | - |
is a wireless parking sensor
Equipment Class
JAB - Part 15 Class B Digital Device