FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Linde Material Handling GmbH/
  3. 2AYVBD2S0009461125

2AYVBD2S0009461125Safety Guard

Linde Material Handling GmbH

Application Details

Equipment Class
UWB - Ultra Wideband Transmitter
Date of Grant
Nov 28, 2024
Application Purpose
Original Equipment
Date of Application
Nov 24, 2024
Equipment Note
Safety Guard
Frequency Range
6142.00000000 - 6792.00000000
Company
Linde Material Handling GmbH
Country
Germany

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 10/09/2024 Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: 2AYVBD2S0009461125 TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, Linde Material Handling GmbH is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Volker Koester, Technical Director Linde Material Handling GmbH, Carl-von-Linde-Platz 63743 Aschaffenburg, Germany +49-231-700996-12 Volker Köster Technical Director Linde Material Handling GmbH Carl-von-Linde-Platz 63743 Aschaffenburg Germany COMNOVO GMBH Robert-Schuman-Str. 6 44263 Dortmund Germany

Attestation Statements

V02072023 Federal Communications Commission Date: 10/09/2024 Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID:2AYVBD2S0009461125 Grantee FRN: 0030515647 Linde Material Handling GmbH certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. Linde Material Handling GmbH accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance consulting, LLC dba iCertifi FCC FRN: 0033399411 Address: 1001 SW Disk Drive, Suite 250, Bend, Oregon 97702 Contact Person: Paul Preston Tel: 866-885-4575 Email: [email protected] Linde Material Handling GmbH Americas Compliance Consulting LLC dba iCertifi Volker Köster Paul Preston Linde Material Handling GmbH Carl-von-Linde-Platz 63743 Aschaffenburg Germany COMNOVO GMBH Robert-Schuman-Str. 6 44263 Dortmund Germany

Cover Letter(s)

Document Version 1.1 2020-10-30 SHORT-TERM CONFIDENTIALITY REQUEST for Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request Short-Term Confidentiality for the following product: For the product stated above, we request Short-Term Confidentiality for exhibits which contain External Photos, Internal Photos, Test Setup Photos, User Manual. We request Short-Term Confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device which is planned for: We are aware that the Short-Term Confidentiality must be released when the product is marketed. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Check your GC here. Click Grantee Search. FCC ID: Grantee Code Equipment Product Code

Cover Letter(s)

Document Version 1.1 2020-10-30 LONG-TERM CONFIDENTIALITY REQUEST for Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 TO WHOM IT M AY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request Long-Term Confidentiality for the following product: For the product stated above, we request Long-Term Confidentiality for exhibits which contain Block Diagram, Operational Description, Parts List/Tune Up Info, Schematics, SDR Software/Security Info. The above exhibits contain ou r trade secrets and proprietary information that could be of benefit to o ur competitors. This information will not be publicly available. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Check your GC here. Click Grantee Search. FCC I D: Grantee Code Equipment Product Code

ID Label/Location Info

0009461125 CDS-08/03 NA Truck_Unit 2 Part-No.: 0009461125 S/N: XX-XXXXXX-CW/YY MAC: A0:33:D1:6B:94:12:5C:03 Made in Germany FCC ID: 2AYVBD2S0009461125 ISED: 26947-D2S9461125 This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference and, (2) this device must accept any interference received, including that may cause undesired operation Le présent appareil est conforme aux CNR d‘industrie Canada applicables aux appareils radio exempts de licence. L‘exploitation est autorise aux deux conditions suivantes: (1) l‘appareil ne doit pas produire de brouillage, et (2) l‘utilisateur de l‘appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d‘en compromettre le fonctionnement

RF Exposure Info

© cetecom advanced GmbH Page 1 of 12 TEST REPORT Test report no.: 1-8036-24-01-09_TR1-R02 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 Linde Material Handling GmbH Carl-von-Linde-Platz 63743 Aschaffenburg / GERMANY Phone: +49 231 700996 10 Contact: Volker Köster e-mail: [email protected] Manufacturer Comnovo GmbH Robert-Schuman-Straße 6 44263 Dortmund / GERMANY Test Item Kind of test item: Safety Guard Model name: Truck Unit 2 FCC ID: 2AYVBD2S0009461125 Frequency: 3100 MHz to 10600 MHz Technology tested: UWB This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Alexander Hnatovskiy Eric Tuettmann Lab Manager Testing Manager Radio Labs Radio Labs Test report no.: 1-8036-24-01-09_TR1-R02 © cetecom advanced GmbH Page 2 of 12 1 Table of contents 1 Table of contents ............................................................................................................................................. 2 2 General Information ......................................................................................................................................... 3 2.1 Notes and Disclaimer ............................................................................................................................ 3 2.2 References ............................................................................................................................................ 3 2.3 Structure of this Document ................................................................................................................... 3 3 General RF Exposure Test Exemptions ............................................................................................................ 4 3.1 1 mW Test Exemption ........................................................................................................................... 5 3.2 MPE- Based Test Exemption ................................................................................................................. 5 3.3 SAR-Based Test Exemption .................................................................................................................. 5 3.4 Simultaneous Transmission ............................................................................................................... 6 4 1 mW Test Exemption ...................................................................................................................................... 7 4.1 Detailed Description .............................................................................................................................. 7 4.2 Results ................................................................................................................................................... 7 5 MPE-Based Test Exemption ............................................................................................................................ 8 5.1 Detailed Description .............................................................................................................................. 8 5.2 Results ................................................................................................................................................... 9 6 SAR-Based Test Exemption ........................................................................................................................... 10 6.1 Detailed Description ............................................................................................................................ 10 6.2 Results ................................................................................................................................................. 11 7 Simultaneous Transmission .......................................................................................................................... 11 7.1 Detailed Description ............................................................................................................................ 11 7.2 Result................................................................................................................................................... 11 8 Conclusion ...................................................................................................................................................... 12 Test report no.: 1-8036-24-01-09_TR1-R02 © cetecom advanced GmbH Page 3 of 12 2 General Information 2.1 Notes and Disclaimer The test results of this test report relate exclusively to the test item specified in this test report. cetecom advanced GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of cetecom advanced GmbH. The testing service provided by cetecom advanced GmbH has been rendered under the current "General Terms and Conditions for cetecom advanced GmbH". cetecom advanced GmbH will not be liable for any loss or damage resulting from false, inaccurate, inappropriate…

Text truncated - open the document above for the full version.

Test Report

`Dielectric Chip Antenna - 1 - Stub L W T Chip Antenna Dimension Chip Antenna Soldering Pad Dimension PCB Soldering Land & Stub Dimension B A B C A C A A E A E A F D A Soldering Land D L8.0 W6.0 T1.2 A1.0 B2.0 C1.5 D2.1 E1.6 F13.0 ■ ELECTRICAL CHARACTERISTICS SWR & Smith chart ■ MECHANICAL DIMENSION (unit : mm, tolerance : ± 0.1) This specification covers the dielectric chip antenna ACS5200HFAUWB used in3200~7200MHzWireless Communication. ■ P/N : ACS5200HFAUWB `Dielectric Chip Antenna - 2 - ■ ELECTRICAL CHARACTERISTICS (2D) 2D Measurement Frequency [MHz]32004200520062007200 Gain Azimuth Theta Peak-0.882.732.514.161.31 Average-4.26-1.22-1.88-1.10-4.82 Phi Peak-3.84-2.16-1.91-2.61-5.20 Average-9.61-8.20-8.16-9.96-11.63 Elevation 1 Theta Peak-5.05-2.32-1.030.30-0.68 Average-10.36-8.84-7.90-6.99-8.06 Phi Peak-2.991.981.812.920.20 Average-6.65-3.30-3.37-3.04-3.71 Elevation 2 Theta Peak-5.83-3.38-2.050.26-3.56 Average-10.76-9.16-7.01-5.74-8.27 Phi Peak-0.522.231.521.391.12 Average-5.23-3.30-3.66-3.90-4.74 Azimuth PlaneElevation1 PlaneElevation2 Plane 0° 90° 180° 270° 0° 90° 180° 270° 0°180° 90° 270° ThetaVertical field of measured plane PhiHorizontal field of measured plane `Dielectric Chip Antenna - 3 - Azimuth Theta -50 -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 -50 -40 -30 -20 -10 0 Amplitude [dB] 3.2000 G 4.2000 G 5.2000 G 6.2000 G 7.2000 G Azimuth Theta Azimuth Phi -50 -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 -50 -40 -30 -20 -10 0 Amplitude [dB] 3.2000 G 4.2000 G 5.2000 G 6.2000 G 7.2000 G Azimuth Phi ■ 2D RADIATION PATTERN `Dielectric Chip Antenna - 4 - Elevation1 Theta -50 -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 -50 -40 -30 -20 -10 0 Amplitude [dB] 3.2000 G 4.2000 G 5.2000 G 6.2000 G 7.2000 G Elevation1 Theta Elevation1 Phi -50 -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 -50 -40 -30 -20 -10 0 Amplitude [dB] 3.2000 G 4.2000 G 5.2000 G 6.2000 G 7.2000 G Elevation1 Phi ■ 2D RADIATION PATTERN `Dielectric Chip Antenna - 5 - Elevation2 Theta -50 -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 -50 -40 -30 -20 -10 0 Amplitude [dB] 3.2000 G 4.2000 G 5.2000 G 6.2000 G 7.2000 G Elevation2 Theta Elevation2 Phi -50 -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 -50 -40 -30 -20 -10 0 Amplitude [dB] 3.2000 G 4.2000 G 5.2000 G 6.2000 G 7.2000 G Elevation2 Phi ■ 2D RADIATION PATTERN `Dielectric Chip Antenna - 6 - ■ Gain Measurement block diagram ■ Soldering Condition - Reflow Soldering - Reflow Soldering Preheat 130 ~ 180°C 200°C 160°C 100°C 25°C 0°C Peak temp. 260±5°C 90 ~ 180sec Max 30sec 30~60sec 260°C Time [sec] - Manual Soldering Condition Pre-Heating Temperature120 °C ,60 ∼ 300 sec Soldering Temperature340 °C ±5 °C , 5 sec max per each terminal `Dielectric Chip Antenna - 7 - GND clearance region Ground Region Stub region Antenna GND clearance region Ground Region < Top View >< Bottom View > ■ Recommended Test Board(CAD) ■ FEEDING METHOD (unit : mm, tolerance : ± 0.05) Unit : mm Board thickness : 1.0mm `Dielectric Chip Antenna - 8 - ■ LOT 번호 표기법 &Marking ◀ UWB 3 C ①②③④ ① Feeding Direction ② Model ③년 : 0 - 2010, 1 - 2011, 2 - 2012, 3 - 2013, 4 - 2014, .... ④ 월 :1-1 월 ,2-2 월 , .... ,A-10 월 ,B-11 월 ,C-12 월 Marking View

Test Report

TEST REPORT Test report no.: 1-8036-24-01-08_TR1-R01 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://www.cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 Linde Material Handling GmbH Carl-von-Linde-Platz 63743 Aschaffenburg / GERMANY Phone: +49 231 700996 10 Contact: Volker Köster e-mail: [email protected] Manufacturer Comnovo GmbH Robert-Schuman-Straße 6 44263 Dortmund / GERMANY Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Safety Guard Model name: Truck Unit 2 FCC ID: 2AYVBD2S0009461125 Frequency: 3100 MHz to 10600 MHz Technology tested: UWB Antenna: Integrated antenna Power supply: 7.8 V to 30.0 V DC by external power supply (vehicular battery) Temperature range: -40°C to +85°C This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Frank Heussner Stephan Thiel Lab Manager Testing Manager Radio Labs Radio Labs Test report no.: 1-8036-24-01-08_TR1-R01 © cetecom advanced GmbH Page 2 of 66 1 Table of contents 1 Table of contents .................................................................................................................................... 2 2 General information ................................................................................................................................ 3 2.1 Notes and disclaimer..................................................................................................................... 3 2.2 Application details ........................................................................................................................ 3 2.3 Involved test locations .................................................................................................................. 4 2.4 Test laboratories sub-contracted ................................................................................................... 4 2.5 Laboratory listings and recognitions .............................................................................................. 4 3 Test standard/s, references and accreditations ....................................................................................... 5 4 Reporting statements of conformity – decision rule ................................................................................ 6 5 Test environment.................................................................................................................................... 7 6 Test item ................................................................................................................................................ 7 6.1 General description ....................................................................................................................... 7 6.2 Additional information ................................................................................................................... 8 7 Description of the test setup ................................................................................................................... 9 7.1 Shielded semi anechoic chamber ................................................................................................ 10 7.2 Shielded fully anechoic chamber ................................................................................................. 12 7.3 Radiated measurements > 18 GHz ............................................................................................... 14 8 Sequence of testing .............................................................................................................................. 16 8.1 Sequence of testing radiated spurious 9 kHz to 30 MHz............................................................... 16 8.2 Sequence of testing radiated spurious 30 MHz to 1 GHz .............................................................. 17 8.3 Sequence of testing radiated spurious 1 GHz to 18 GHz ............................................................... 18 8.4 Sequence of testing radiated spurious above 18 GHz ................................................................... 19 8.5 Sequence of testing efficient use of spectrum ............................................................................. 20 9 Measurement uncertainty ..................................................................................................................... 21 10 Summary of measurement results ................................................................................................... 22 11 Additional comments ...................................................................................................................... 22 12 Measurement results ...................................................................................................................... 24 12.1 10 dB - Bandwidth ................................................................................................................... 24 12.2 TX Radiated Emissions ............................................................................................................ 28 12.2.1 TX Radiated Emissions for UWB channel…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Volker Koester(Technical Director)
[email protected]+4923170099612Fax: +4923170099614

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
315F6.14 GHz - 6.79 GHz-
Confidentiality
Long Term
Grant Notes
Forklift truck component of an approach warning system for prevention of collisions between pedestrians and moving machinery. Operation onboard an aircraft, a ship or a satellite is prohibited. The use of devices mounted on outdoor structures, e. g. Static Units mounted on the outside of a building or any fixed outdoor infrastructure is prohibited.

Other Applications from Linde Material Handling GmbH

Display Unit - FCC ID 2AYVBD2S0009461002 - Linde Material Handling GmbH
2AYVBD2S0009461002

Display Unit

Jun 03, 2021

Equipment Class

UWB - Ultra Wideband Transmitter
UWB Pedestrian Tag - FCC ID 2AYVBD2S0009734953 - Linde Material Handling GmbH
2AYVBD2S0009734953

UWB Pedestrian Tag

Jun 03, 2021

Equipment Class

UWB - Ultra Wideband Transmitter
UWB infrastructure Unit - FCC ID 2AYVBD2S0009734942 - Linde Material Handling GmbH
2AYVBD2S0009734942

UWB infrastructure Unit

Jun 03, 2021

Equipment Class

UWB - Ultra Wideband Transmitter
Active UWB Antenna - FCC ID 2AYVBD2S0009469010 - Linde Material Handling GmbH
2AYVBD2S0009469010

Active UWB Antenna

Jun 03, 2021

Equipment Class

UWB - Ultra Wideband Transmitter
UWB Programmer - FCC ID 2AYVBD2S0009469018 - Linde Material Handling GmbH
2AYVBD2S0009469018

UWB Programmer

Jun 03, 2021

Equipment Class

UWB - Ultra Wideband Transmitter