TITLE: IFU 130H-Plus US DEPARTMENT: Product NUMBER: IFU-0002 REVISION: 1.0 Confidential Neteera technologies, Ltd P. 1 of 8 Neteera 130H-Plus/131H-Plus Instructions for Use Reviewers Name Position Date Signature Author Amatzia Mass Product Manager 22-Dec-22 Reviewer Rakefet Shohat VP Quality & Regulations 22-Dec-22 Approver Shahar Yaron VP Product 22-Dec-22 * Release date is same as last signature date Revision History Version Author Changes 1.0 Amatzia Mass First Issue (based on IFU 130H US Rev 3.0) * This page should not be included in the printed version. Neteera Technologies Ltd. Confidential P. 1 of 7 User Manual – 130H-Plus/131H-Plus Registered Manufacturer: Neteera Technologies Ltd at: Prof. Rakah 3 St. Jerusalem Israel 9139002 [+972] (0)2-580-8733 US Importer: Hudson Scientific 103 W Main Street Hudson, MI 49247 (517) 212-4047 Product name/model: Neteera 130H-Plus/131H-Plus Device Description: The Neteera device is a contactless vital signs monitor for measurement, data collection, and display of Heart Rate and Respiratory Rate. Neteera’s device is based on a high frequency (122.25-123 GHz) micro-radar on-chip and algorithm, capable of detecting physiological parameters (Respiration Rate (RR), Heart Rate (HR)) during rest or while monitoring a person’s mild body movement. Neteera’s novel micro- radar-based solution enables remote measurement, in real-time, in a non- invasive and contact-free manner. The system works by measuring only the micro-movements of the skin (BCG) through non-conductive materials such as furniture and clothing at a high resolution, and it has several different mounting options and measuring ranges. The presented product, the Neteera 130H-Plus/131H-Plus, contains a Wi-Fi component that enables communication and data transfer over the internet to the Neteera cloud, “HealthGate”. Intended Use: The Neteera System, Neteera 130H-Plus/131H-Plus device, is intended for spot and continuous measurement of heart rate and respiration rate in adult patients in healthcare facilities. The indications provided are to be used by health care professionals and are intended to be reviewed by clinicians to inform patient care. The Neteera monitoring system is not intended to be used as an alarm system for potentially life- threatening situations in which medical intervention is necessary (e.g., ICU). Neteera Technologies Ltd. Confidential P.2 of 7 Contra-Indications: Neteera 130H-Plus/131H-Plus is contraindicated for use in: •People for whom proper positioning cannot be achieved or maintained. •A combustible environment or in the presence of flammable anesthetics or gases. •Situations where a dry environment cannot be ensured. •A Magnetic Resonance Imaging (MRI) environment. •Any other system or environment which was not authorized by Neteera Technologies LTD. Company. General Hazards: •Do not use a damaged Neteera 130H-Plus/131H-Plus device – cracked/broken plastic case, cracked/broken lens, defective USB connection, or any other indication of physical damage to the Neteera 130H-Plus/131H-Plus device. The use of a damaged Neteera 130H-Plus/131H- Plus device might result in the malfunction of the system. •Handle the Neteera 130H-Plus/131H-Plus device with care. •Do not drop, knock, or shake the unit. •Rough handling can damage the internal circuit boards. •The sensor is intended for indoor operation only. Avoid any contact with water or any other chemical. Cleaning is only allowed using a damp clean cloth, without harsh detergents, or per healthcare facility procedures. •A damaged Neteera 130H-Plus/131H-Plus device should not be disposed of as unsorted municipal waste. Contact your local distributor for unit disposal. •Changes or modifications not expressly approved (in writing) by Neteera technologies could affect the safety or effectiveness of the Neteera 130H-Plus/131H-Plus device performance and void the warranty. •The Neteera 130H-Plus/131H-Plus device is designed with reasonable protection against harmful interference in a typical medical installation. However, because of the proliferation of radio frequency transmitting equipment and other sources of electrical noise in healthcare and other environments, it is possible that high levels of such interference due to proximity or strength of a source might impact the performance of the Neteera 130H- Plus/131H-Plus device. Additionally, interference from emitters such as diathermy or electrocautery devices or wireless power transfer devices (e.g., wireless phone chargers) may impact performance of the Neteera 130H-Plus/131H-Plus device. Neteera Technologies Ltd. Confidential P. 3 of 7 Warnings and Cautions: • If the device does not operate properly, contact Neteera Support. • Use only the supplied accessories and parts. In case a part or accessory should need to be replaced, please contact Neteera support. Do not attempt to replace parts or accessories without prior consultation by Neteera support. • When using the Neteera system, do not share the chair/bed being monitored with another person or pet during Neteera 130H-Plus/131H-Plus device recording session. o Sharing the chair or bed could affect the effectiveness of the system and the accuracy of the measurements. • Avoid using heated blankets, or any other metal-containing heating item located between the Neteera 130H-Plus/131H-Plus device and the monitored person. The use of heating blankets could affect the effectiveness of the Neteera 130H-Plus/131H-Plus and void the system’s warranty. • The monitored person should not have direct contact with the Unit – a minimum distance of 5cm should be maintained. • Neteera 130H-Plus/131H-Plus device is not intended to be a replacement for monitoring high-risk situations where ECG monitoring is required. The most reliable method of monitored person monitoring combines the close personal surveillance with the correct operation of the monitoring equipment. • The Neteera 130H-Plus/131H-Plus technology and parameters have not been stu…
Text truncated - open the document above for the full version.
Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_02 15-02-2023 Certification Application Attestation Statements Neteera Technologies LTD Prof. Rakah 3 St Jerusalem 9139002 Israel Subject: FCC ID: 2AYVONETEERA130PLUS To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) Neteera Technologies LTD certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) Neteera Technologies LTD (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 9-Feb-2023 City: Jerusalem Name (2) : Shahar Yaron Function: VP Product Telephone number: + 972526809220 Email address: [email protected] Signature: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” Covered list attestation FCC application letter Kiwa Page 2 of 2 RF_755_02 15-02-2023 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvM 02 1 15-02-2023 Changed Applicant to Company and added “Subject: FCC ID: “ RvdM Issued/modified by : Richard van de Meer Function : Certification assessor Revision : 02 Date : 15-02-2023 Verified by : Willem Jan Jong Function : Team Lead Date : __-02-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : __-02-2023
V02072023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03/10/2023 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: 2AYVONETEERA130PLUS Neteera Technologies Ltd. certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. Neteera Technologies Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance consulting, LLC dba iCertifi FCC FRN: 0033399411 Address: 1001 SW Disk Drive, Suite 250, Bend, Oregon 97702 Contact Person: Paul Preston Tel: 866-885-4575 Email: [email protected] Sincerely, Manufacturer Name Americas Compliance Consulting LLC dba iCertifi Manufacturer Contact Paul Preston Signature Neteera Technologies Ltd. Rakefet Shohat
TCB GRANT OF EQUIPMENT AUTHORIZATION TCB Certification Issued Under the Authority of the Federal Communications Commission By: Telefication B.V. Edisonstraat 12a Zevenaar, NL-6902 PK Netherlands Date of Grant: 04/22/2021 Application Dated: 04/21/2021 ESPRESSIF SYSTEMS (SHANGHAI) CO., LTD Suite 204, Block 2, 690 Bibo Road, Zhang Jiang Hi-Tech Park, Shanghai, 201203 China Attention: Mia Zhou NOT TRANSFERABLE EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. FCC IDENTIFIER: 2AC7Z-ESPWROOM32DC Name of Grantee: ESPRESSIF SYSTEMS (SHANGHAI) CO., LTD Equipment Class:Part 15 Spread Spectrum Transmitter Notes:Wi-Fi Module Grant Notes FCC Rule Parts Frequency Range (MHZ) Output Watts Frequency Tolerance Emission Designator 15C2412.0 - 2462.00.079 Class II Change: This change (a) incorporates this Wi-Fi module of ESPRESSIF SYSTEMS (SHANGHAI) CO., LTD in to Neteera technologies Ltd. portable host Respiratory and cardiac rate monitor. Any configuration other than the one described will require a separate approval. End end-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The maximum conducted output power of the ESP32 module is limited to 19 dBm by the end user. Modular approval. Output power listed is conducted. This grant is valid only when the module is sold to OEM or OEM integrators. Modular approval for use as a module in mobile-only RF exposure conditions. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. Installation of this device into portable RF Exposure category host devices requires the submission of a Class II permissive change or new application. Certificate No.: 212180398/AA/00 Mark Chung Product Assessor
RF_160, Issue 04 (On manufacturer’s company letter heading) Declaration of Authorization We Name: Neteera Technologies Ltd. Address: Prof. Rakah 3 St.. City: Jerusalem 9139002. Country: Israel . Declare that: Name Representative of agent: ............. (1) Agent Company name: Hermon Laboratories Ltd. . Address: Harakevet Industrial Zone .. City: Binyamina 30500 .. Country Israel . is authorized to apply for Certification of the following product(s): Product description: Respiratory and cardiac rate monitor . Type designation: 1) Neteera 130H-Plus 2) Neteera 131H-Plus Trademark: NA . Validity/ expiry date February 07, 2024 on our behalf. Date: February 07, 2023.. City: Jerusalem .. Name: Shahar Yaron.. (2) Function: VP product.... Signature: ... Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
Measurement Report for Antennas for Albatross 1 Antennas for Albatross The measurements were performed on package substrate. RF probes were used to contact TX and RX antennas. A four patch-array is used as transmit and receive antenna for Albatross B0. 1.1 Substrate Figure 1 Picture of package substrate with antennas. 1.2 Antenna specification Parameter Min Typ Max Unit Remarks / Condition Frequency range 116 123 GHz Total Efficiency 55 68 % Gain Tx (E-Plane) 8 10 11 dBi @ Theta=0 deg Gain Tx (H-Plane) 8 10 11 dBi @ Theta=0 deg Gain Rx (E-Plane) 8 10 11 dBi @ Theta=0 deg Gain Rx (H-Plane) 8 10 11 dBi @ Theta=0 deg Antenna aperture 60 ° horizontal Antenna aperture vertical 60 ° Boresight deviation (E- plane) -10 0 +10 ° Boresight deviation (H- plane) -10 0 +10 ° S-Parameters (Port1: Tx- Antenna, Port2: Rx- Antenna) -19 -12 -5 dB Dimension Tx (x/y) 1.76/ 1.76 mm Patch array without feeding line Dimension Rx (x/y) 1.76/ 1.76 mm Patch array without feeding line Polarization Linear Measurement Results 1.3 RX antenna measurements Figure 2 RX antenna gain vs frequency. 1.4 TX antenna measurements Figure 5 TX antenna gain vs frequency.
FCC, Request for non-disclosure Date: 08-Oct-2021 RF_501, Issue 9 Page 1 of 1 Company Name: Neteera Technologies LTD Address: Prof. Rakah 3 St., City: Jerusalem 9139002 Country: Israel To: Telefication B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: 2AYVONETEERA130PLUS Reference number: 47235 Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: The above information may assist competitors in understanding the system archtecture and major components, which may hurt our competitive advantage and help competitors with designing competing products Date: March 22, 2023 Name and signature of applicant: Shahar Yaron Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 1 of 3 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 2 of 3 Photograph No.1 130H-Plus / 131H-Plus front view Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 3 of 3 Photograph No.2 130H-Plus / 131H-Plus rear side view
Confidential & Proprietary Labeling Representation LBL-0002 Rev 1.1 Confidential & Proprietary •Purpose & Scope oThe following document presents all Neteera’s device labels. General 2 Reviewers NamePositionDateSignature AuthorYoniLeviProduction Manager22-Dec-22 ReviewerRakefetShohatVP QA/RA 22-Dec-22 ApproverShaharYaronVPProduct 22-Dec-22 RevisionHistory VersionAuthorChanges 1.0YoniLeviInitialRelease(included210Hlabelsonly) 1.1YoniLeviECO#2022-04Renamed210/211to130H-Plus&131H-Plus Confidential & Proprietary 130H-Plus US -210-00-101-00 3 Device Label: 210-12-101-00 Rev 1.1 Confidential & Proprietary 131H-Plus US -211-00-101-00 4 Device Label: 211-12-101-00 Rev 1.1
Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 1 of 4 INTERNAL PHOTOGRAPHS This document contains 3 photographs Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 2 of 4 Photograph No.1 130H-Plus / 131H-Plus PCB Internal view Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 3 of 4 Photograph No.1 130H-Plus / 131H-Plus PCB Component side Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 4 of 4 Photograph No.2 Difference of 130H-Plus / 131H-Plus Print side of the main PCB
Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 1 of 3 Environmental evaluation and exposure limit according to FCC CFR 47part 1, §1.1307, §1.1310 and ANSI/IEEE C95.1-1992 This calculation was done based on the test performed by Hermon Laboratories. The 131H-Plus are devices that classified as portable, included 1 transmitter operating according to FCC part 15 section 15.258 in frequency range 119000 – 122980 MHz. The 130H-Plus are devices that classified as portable, included 1 transmitter operating according to FCC part 15 section 15.258 in frequency range 119000 – 122980 MHz and approve by FCC Wi-Fi module, FCC ID: 2AC7Z-ESPWROOM32DC . 131H-Plus models: In 119000 – 122980 MHz range: The SAR Test Exclusion Thresholds of the guidance is limited only up to 6 GHz. According to ANSI/IEEE C95.1-1992 the portable device operating at frequencies above 6 GHz is evaluated in terms of MPE limits. Since the EUT is device to cover the frequency range of the EUT above 6 GHz, the MPE will be used as per general guidance for mobile device with minimum separation distance applicable to the operating of 5 cm. Limit for power density for general population/uncontrolled environment is 10 mW/cm 2 for 15000 - 300000 MHz frequency range. The power density P (mW/cm 2 ) = P T / 4 r 2 , where PT is the maximum equivalent isotropically radiated power (EIRP), measured value is 19.26 dBm, which is equal to 84.33 mW. The power density at 5 cm calculated as follows: 84.33 mW /4 (5 cm) 2 ≈ 0.268 mW/cm 2 << 10 mW/cm 2 General public cannot be exposure to dangerous RF level. Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 2 of 3 130H-Plus models: In 119000 – 122980 MHz range: The SAR Test Exclusion Thresholds of the guidance is limited only up to 6 GHz. According to ANSI/IEEE C95.1-1992 the portable device operating at frequencies above 6 GHz is evaluated in terms of MPE limits. Since the EUT is device to cover the frequency range of the EUT above 6 GHz, the MPE will be used as per general guidance for mobile device with minimum separation distance applicable to the operating of 5 cm. Limit for power density for general population/uncontrolled environment is 10 mW/cm 2 for 15000 - 300000 MHz frequency range. The power density P (mW/cm 2 ) = P T / 4 r 2 , where PT is the maximum equivalent isotropically radiated power (EIRP), measured value is 19.26 dBm, which is equal to 84.33 mW. The power density at 5 cm calculated as follows: 84.33 mW /4 (5 cm) 2 ≈ 0.268 mW/cm 2 << 10 mW/cm 2 In 2412-2462 MHz range: The Wi-Fi modular transmitter as approval under FCC ID: 2AC7Z-ESPWROOM32DC will be used in portable device (130H- Plus). The maximum conducted output power of the module is limited to 19 dBm according to the manufacturer manual. Maximum declare transmitter power obtained from the User Manual: Pout EIRP Maximum antenna gain, dBi Pout conducted dBm mW dBm mW 22.71 186.63 3.71 19 79.43 According to KDB 447498 D01 v05r02 section 4.3.1 the exemption limit for 100 MHz to 6 GHz at ≤ 50 mm distance is determined as follow: [(max. power including tune-up tolerance, mW) / (min. test separation distance, mm)] x [√f(GHz)] ≤ 3.0 for 1-g whole body SAR SAR test exclusion threshold for frequency 2462 MHz at minimum separation distance of 50 mm: 3 x 50 mm /(√2.462) = 95.60 mW Neteera technologies Ltd. FCC ID: 2AYVONETEERA130PLUS Page 3 of 3 Summation When all the antennas are at least 5 cm away from the user but individual antennas cannot be separated by 5 cm from each other, the following equation shall be fulfilled S1/Limit + S2/Limit < 1, i.e. 0.268 mW/cm 2 /10 mW/cm 2 + 79.43 mW /95.60 mW = 0.0268 +0.8308 = = 0.8576 < 1 General public cannot be exposed to dangerous RF level. Shahar Yaron, VP product Neteera Technologies LTD
Hermon Laboratories Ltd. P.O. Box 23, Binyamina 3055001, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 90 Report ID: NETRAD_FCC.47235_Rev1.docx Date of Issue: 22-Feb-23 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC 47 CFR part 15 section 15.258 FOR: Neteera technologies Ltd. Respiratory and cardiac rate monitor Models: Neteera 130H-Plus/Neteera 131H-Plus FCC ID: 2AYVONETEERA130PLUS This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: NETRAD_FCC.47235_Rev1.docx Date of Issue: 22-Feb-23 Page 2 of 90 Table of contents 1 Applicant information ..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details .................................................................................................................................................................... 3 5 Tests summary .............................................................................................................................................................. 4 6 EUT description ............................................................................................................................................................. 5 6.1 General information ....................................................................................................................................................... 5 6.2 Test configuration .......................................................................................................................................................... 5 6.3 Changes made in EUT .................................................................................................................................................. 5 6.4 Transmitter characteristics ............................................................................................................................................ 6 7 Transmitter tests according to 47CFR part 15 subpart C .............................................................................................. 7 7.1 Transmitter power test ................................................................................................................................................... 7 7.2 Occupied bandwidth test ............................................................................................................................................. 13 7.3 Out of band radiated emissions below 40GHz ............................................................................................................ 16 7.4 Out of band radiated emissions above 40 GHz up to 370 GHz ................................................................................... 30 7.5 Frequency stability test ................................................................................................................................................ 78 7.6 Antenna requirements ................................................................................................................................................. 80 8 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 81 9 APPENDIX B Test equipment correction factors ......................................................................................................... 83 10 APPENDIX C Measurement uncertainties .................................................................................................................. 87 11 APPENDIX D Test laboratory description ................................................................................................................... 88 12 APPENDIX E Specification references........................................................................................................................ 88 13 APPENDIX F Abbreviations and acronyms ................................................................................................................. 89 14 APPENDIX F Manufacturer’s declaration .................................................................................................................... 90 Report ID: NETRAD_FCC.47235_Rev1.docx Date of Issue: 22-Feb-23 Page 3 of 90 1 Applicant information Client name: Neteera Technologies Ltd. Address: Prof. Rakah 3 St., Jerusalem, Israel 9139002 Telephone: +972 526809220 Fax: +972 525808733 E-mail: [email protected] Contact name: Mr. Shahar Yaron 2 Equipment under test attributes Product name: Respiratory and cardiac rate monitor Product type: Monitor Model(s): Neteera 130H-Plus Serial number: NA Hardware version: 1.0 Software release: 4.0 Receipt date 19-Oct-22 3 Manufacturer information Manufacturer name: Neteera Technologies Ltd. Address: Prof. Rakah 3 St., Jerusalem, Israel 9139002 Telephone: +972 526809220 Fax: +972 525808733 E-Mail: [email protected] Contact name: Mr. Shahar Yaron 4 Test details Project ID: 47235 Location: Hermon Laboratories Ltd. P.O. Box 23, Binyamina 3055001, Israel Test started: 30-Oct-22 Test completed: 27-Nov-22 Test specification(s): FCC 47 CFR part 15 section 15.258 Report ID: NETRAD_FCC.47235_Rev1.docx Date of Issue: 22-Feb-23 Page 4 of 90 5 Tests summary Test…
Text truncated - open the document above for the full version.
Report ID: NETRAD_FCC.47235_Rev1.docx Date of Issue: 22-Feb-23 Test specification: Section 15.258(c)(3), Out of band radiated emissions above 40 GHz up to 370 GHz Test procedure: ANSI C63.10, Sections 9.9, 9.12 Test mode: Compliance Verdict: PASS Date(s): 31-Oct-22 - 21-Nov-22 Temperature: 27 ºC Relative Humidity: 50 % Air Pressure: 1010 hPa Power: 5 VDC Remarks: Page 33 of 90 Plot 7.4.1 Spurious emission measurements in 40 - 50 GHz range TEST SITE: OATS TEST DISTANCE: 3 m MODULATION: CW ANTENNA POLARIZATION: Vertical and Horizontal DETECTOR: Peak RBW = 1 MHz; VBW = 3 MHz DETECTOR: Average (RMS) RBW = 1 MHz; VBW = 3MHz Low carrier frequency: 119000 MHz Mid carrier frequency: 121000 MHz Report ID: NETRAD_FCC.47235_Rev1.docx Date of Issue: 22-Feb-23 Test specification: Section 15.258(c)(3), Out of band radiated emissions above 40 GHz up to 370 GHz Test procedure: ANSI C63.10, Sections 9.9, 9.12 Test mode: Compliance Verdict: PASS Date(s): 31-Oct-22 - 21-Nov-22 Temperature: 27 ºC Relative Humidity: 50 % Air Pressure: 1010 hPa Power: 5 VDC Remarks: Page 34 of 90 Plot 7.4.2 Spurious emission measurements in 40 - 50 GHz range (continuation) TEST SITE: OATS TEST DISTANCE: 3 m MODULATION: CW ANTENNA POLARIZATION: Vertical and Horizontal DETECTOR: Peak RBW = 1 MHz; VBW = 3 MHz DETECTOR: Average (RMS) RBW = 1 MHz; VBW = 3MHz High carrier frequency: 122980 MHz Report ID: NETRAD_FCC.47235_Rev1.docx Date of Issue: 22-Feb-23 Test specification: Section 15.258(c)(3), Out of band radiated emissions above 40 GHz up to 370 GHz Test procedure: ANSI C63.10, Sections 9.9, 9.12 Test mode: Compliance Verdict: PASS Date(s): 31-Oct-22 - 21-Nov-22 Temperature: 27 ºC Relative Humidity: 50 % Air Pressure: 1010 hPa Power: 5 VDC Remarks: Page 35 of 90 Plot 7.4.3 Spurious emission measurements in 50 - 60 GHz range TEST SITE: OATS TEST DISTANCE: 3 m MODULATION: CW ANTENNA POLARIZATION: Vertical and Horizontal DETECTOR: Peak RBW = 1 MHz; VBW = 3 MHz DETECTOR: Average (RMS) RBW = 1 MHz; VBW = 3MHz Low carrier frequency: 119000 MHz Mid carrier frequency: 121000 MHz Report ID: NETRAD_FCC.47235_Rev1.docx Date of Issue: 22-Feb-23 Test specification: Section 15.258(c)(3), Out of band radiated emissions above 40 GHz up to 370 GHz Test procedure: ANSI C63.10, Sections 9.9, 9.12 Test mode: Compl…
Text truncated - open the document above for the full version.
Harakevet Industrial zone, P.O.Box 23 · Binyamina · Israel
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 119.00 GHz - 122.98 GHz | 1.10 mW |

Respiratory and cardiac rate monitor
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified