SAFETY AND WARRANTY 1 Safety Information (Do not discard) Read and understand these warnings. Failure to follow them could result in death or serious injury. As with all electrical products, misuse of product or failure to properly follow the instructions may cause overheating, fire or personal injury. Please read the full product instructions before using the Pod. • Pod is not a medical device. It is not designed or intended to diagnose or treat any medical conditions, and you should not use it for these purposes. Consult your doctor for prevention, diagnosis, and treatment of sleep disorders and other medical issues. • Be careful when connecting the Pod’s connector cable, water cord or power cable, to avoid trip hazards. • Do not replace the supplied detachable mains supply cord with an inadequately rated cord. • Do not use with damaged cords. Damaged cords can lead to fire. Do not tuck in, trap, fold, cross or pinch cords or controls between bed slats, mattress or springs, or against walls, footboards or bed frame. • Do not use this product on anyone who cannot clearly understand the instructions and/or operate the mobile app. • The appliance has a heated surface. Persons insensitive to heat must be careful when using the appliance. • Do not use the Pod with infants or children. Death or serious injury could result from the connector cable, water cord or power cable getting around an infant’s or child’s neck during their sleep. 2 • Similarly, if your sleeping habits put you at risk of entangling a bed- side cord or an under-sheet sensor or coils around your neck while sleeping, do not use the Pod. • Do not use the Pod’s heating or cooling feature in combination with analgesic cream. • Pod is not a baby monitor. It will not warn you of any sleeping problems your infant may have. It will not warn you if your infant stops breathing. It will not warn of or prevent sudden infant death syndrome. • Do not dry clean any part of the product. Cleaning liquids may damage the insulation of the heating and cooling element. Improper cleaning or laundering may cause problems with the sensors or cords. To keep clean, cover the Pod with a washable mattress protector and/or bed sheet. • Pod is designed for use with 110-240VAC electrical standards. Do not use with an extension cord. The product may experience increased heat or cool in areas where the product is bunched or folded in use. • Keep all dogs, cats and other pets away from the Pod, especially the cords. This is an electrical appliance that may damage or injure them. • Do not use the Pod on a waterbed, sofa, adjustable or bunk bed. • Do not use another temperature-regulating device in conjunction with the Pod. • Do not wrap the Active Grid layer around your body. Keep it properly installed on the mattress as directed by the setup process. • Do not disassemble the Hub or Active Grid layer. There are no repairs you can safely do on them. • If you see the product operating improperly, unplug it immediately and call the Eight Sleep support team in the US at +1-888-699-4015. Product Specifications • Supply voltage range: 110-240VAC • Mains supply voltage fluctuations: 95-260VAC 3 Repairs There are no repairs that you can safely do on the Pod. All repairs are unauthorized and will void this Limited Warranty. You expressly understand that if you replace or repair any part of the product, Eight Sleep, Inc. is not liable for any damages to Pod, your bed, your bedding or any property. How to Obtain Warranty Service You must present the following information to make a warranty claim: • Model of your product. • Your full address and contact information. • Your purchase receipt or other proof of date purchased and date of delivery. • To make a warranty claim, please contact us at support@ eightsleep.com for warranty service. • No employee or representative of Eight Sleep, Inc. or any third party is authorized to modify, extend, or add to this Limited Warranty. • If any term of this Limited Warranty is held to be illegal or unenforceable, the remaining terms of the Limited Warranty will remain in full force and effect. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. • Frequency range: 50-60Hz • Power or current rating: 300W • Indoor or outdoor use: Indoor use only • Altitude: up to 3000m (10000ft) • Temperature range: 15°C to 35°C (59°F to 95°F) • Humidity range: 0-90% (non-condensing) • Overvoltage category: Overvoltage Category II • Pollution degree: Pollution degree 2 4 Regulatory Statements USA FEDERAL COMMUNICATIONS COMMISION (FCC) Model Number: 10503 Marketing Name: Pod 3 (A18) FCC ID: 2AYXT61100001 Responsible Party – U.S. Contact Information: Eight Sleep 212 W 35th Street, 4th Floor, New York, NY 10123 +1 (888) 699 4015 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equip…
Text truncated - open the document above for the full version.
Your journey starts here Great sleep starts here Download the Eight Sleep app to begin setup Or, if you are an existing user, this QR code will also help you set up your new Pod. 3 5 Welcome to the sleep fitness club Sleep fitness is a real thing. It’s a state of overall health and well-being fueled by quality sleep. Being sleep fit results in a feeling of restoration, elevated energy levels and confidence. In short, being sleep fit enhances perfor- mance in everything we humans do. Dr. Philip Gerhman from University of Pennsylvania’s Perelman School of Medicine defines sleep fitness as, “the extent to which we are getting sufficient quantity and quality of sleep to be energized and functioning at peak leavels during the day.” Most of all, sleep fitness is actionable, measurable and achievable. It opens room in the conversation for positive reinforcement and advocacy around sleep, something that is missing from the current dialogue. We designed the Pod to help you achieve sleep fitness. Like any habit, becoming sleep fit requires discipline and time. The Pod is here to support you in your journey through the best technology that sleep has ever seen. Unlock higher quality sleep every night. Boost your recovery through personalized bed temperature, health monitoring, and digital sleep coaching. 7 Maintenance Instructions Hub Approximately every couple of months, you will be prompted in the Eight Sleep app to refill the Water Tank. Instructions will be presented in the app, but you can also follow the instructions below for refilling and maintenance. Before starting, we recommend you have these on hand, but you can always add them later: • 16 ounces (473 ml) of 3% hydrogen peroxide. • 1/2 gallon (2L) of distilled water. Instructions: • Remove the water tank from the Hub. • If available, add 16 ounces (473 mL) of 3% hydrogen peroxide to the water tank. • Add distilled water up to the fill line. If not available, use tap water instead. • Secure the lid and place the water tank back into the Hub. • Open the app, and head to Menu > Device Settings > Maintenance > Prime Hub, and tap to begin Priming. • After Priming has completed, remove the water tank and refill it with water and hydrogen peroxide. • Secure the lid and place the water tank back into the Hub. • Now the Hub should be ready for use. Hub light cheat sheet Here’s what the light colors on the Hub mean: Solid White Paired and connected to Wi-Fi Solid Orange Disconnected from Wi-Fi Pulsing Green Factory reset in progress Solid Pink Warming is on Pulsing Red Sensor or cord is unplugged Pulsing Yellow Pod is initializing Solid Light Blue Cooling is on Pulsing Blue Pairing Mode Pulsing Orange Connecting to Wi-Fi Active Grid • The Active Grid layer of the Pod is made of polyester and cotton. It is not water-resistant or waterproof. Use a damp cloth for spills or spot treatment, if needed. • Do not wash the Active Grid layer in a washing machine or by hand, nor dry it in a dryer. Doing so will ruin it and void your warranty. • Do not pour any water or liquids on the Active Grid layer. • Do not put the power cord into water. • Do not iron your Active Grid layer. • Do not dry clean your Active Grid layer. Dry cleaning solvents may damage the wires. • Do not bleach or use cleaning fluids. • Do not use a wringer. • Do not use mothballs or sprays of any kinds. • Do not vacuum. • If you wish to protect the Active Grid, use a thin waterproof mattress protector. If you need to move the Active Grid from one location to another, we suggest draining the water out of it. You will find the Drain Tool (Figure A) inside Box 2, side B, right underneath the Hub. This small plastic tool will empty the water out of the Grid. You can find instructions for doing this inside the Eight Sleep app’s Help section. Encasement • Do not bleach or use cleaning fluids. • Do not use a wringer. • Do not use mothballs or sprays of any kinds. Figure A: Drain Tool 9 Contact a Sleep Pro The Pod is designed to be intuitive but sometimes it can help to talk to a human. If you run into any trouble, our Sleep Pros are here to help. We are available seven days a week, with limited hours around major holidays. [email protected] eightsleep.com/support US & Canada: +1 (888) 699 4015 UK: +44 330 818 6258 Europe: +34 518 90 04 68 Australia: +61 2 8311 8131 11 Your journey starts here LSF_T_0300037-08 @eightsleep
US Agent Attestation Letter TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: section 2.911(d)(7) filing To whom it may concern, This letter is to confirm that Alex Lednev has accepted responsibility to act as the agent for service of process as acknowledged by the applicant, Eight Sleep Inc. U.S. Agent: Alex Lednev Title: Senior Electrical Engineer Company Name: Eight Sleep Inc Address: 212 W 35 th St, 4 th Floor, New York, NY 10023 Telephone No: +1 888 699 4015 FRN 0030587562 Email: [email protected] The applicant accepts and acknowledges the obligation to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Signature of Applicant: Signature of U.S. Agent (if different from applicant): Alex Lednev Name: Alex Lednev Name: Date: 02/24/2023 Date:
Date: February 27, 2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Attestation regarding ‘covered’ equipment and the Covered List FCC ID: 2AYXT61100001 To whom it may concern, Per 2.911(d)(5)(i), Eight Sleep Inc certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Per 2.911(d)(5)(ii), Eight Sleep Inc certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Alex Lednev Alex Lednev Senior Electrical Engineer
41039 Boyce Road 510-578-3500 Phone Fremont, CA. 94538 Page 1 of 1 January 25, 2023 Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Road Columbia, MD 21046 Innovation Science and Economic Development Canada Certification and Engineering Bureau 3701 Carling Avenue, Building 94 Ottawa, Ontario K2H 8S2 FCC ID 2AYXT61100001 IC: 29927-61100001 To whom it may concern: The enclosed documents constitute a formal submittal and application for FCC Equipment Authorization as original equipment for a thermoregulated mattress pod hub model 10503 with a 802.11 and BLE transceiver (station) pursuant to the following rules: Subpart C of Part 15 of FCC Rules (CFR 47), §15.247 Subpart E of Part 15 of FCC Rules (CFR 47), § 14.407 RSS-247 Issue 2 NTS Labs, LLC, as duly authorized agent prepared this submittal. A copy of the letter of our appointment as agent is included with the application. If there are any questions or if further information is needed, please contact National Technical Systems for assistance. Sincerely, David W. Bare Chief Engineer DWB/dmg
Element Material Technology (Element) 6775 NE Evergreen Parkway, Suite 400 Hillsboro, OR, 97124 January 20, 2023 Ladies and Gentlemen: This is your letter of authorization to accept our appointment of David W. Bare of National Technical Systems – Silicon Valley as our Agent for Eight Sleep Inc located at 212 W 35 th Street, New York, NY 10123, to sign applications before Element and to make representations to you on our behalf. National Technical Systems – Silicon Valley is to receive and exchange data between our company and Element. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC and Innovation Science and Economic Development Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by Element, still resides with Eight Sleep Inc. I hereby certify on behalf of Eight Sleep Inc (“Applicant”) that neither Applicant nor any party to the application (officers, directors, and 5% shareholders) is subject to a denial of Federal benefits that includes FCC benefits pursuant to section 5301 of the Anti-Drug Abuse Act of 1988 21 U.S.C. 853a. Sincerely, Alex Lednev Alex Lednev Senior Electrical Engineer
Top of EUT Front of EUT Right Side of EUT Left Side of EUT Back of EUT Bottom of EUT
Label Drawing Location Drawing
Top of Module Bottom of Module Module on Control Board Left Wi-Fi Antenna Left Wi-Fi Antenna Right Wi-Fi Antenna Right Wi-Fi Antenna BLE Antenna BLE Antenna Control Board Top Control Board Bottom
1 2400-2500 & 5150-5875 MHz DUAL BAND WLAN / BLUETOOTH ANTENNA Part Numbers: 2344656-1, 2344656-2 2344656-3, 2344656-4 2344656-5, 2344656-6 2344656-7, 2344656-8 •Adhesive backing on FPC simplifies mounting within the device •Omnidirectional coverage •Efficient design reduces power usage •No matching components required •Ground-plane independent design •Wide selection of micro-coaxial cable lengths from 50 to 200mm FEATURES& BENEFITS DATA AND DEVICES /// DUAL BAND WLAN / BLUETOOTH ANTENNA SPECIFICATIONS (Shown as 2344656-1 : Others can vary with different cable lengths.) Frequency Range (MHz)2400-25005150-5875 VSWR< 2.0:1< 2.0:1 Average Efficiency80%80% Peak Gain2.5dBi7.0dBi AverageGain-1.8dB0.1dB Power Handling10 Watt cw Feed Point Impedance50 ohms unbalanced PolarizationLinear Size30 mm x 9.5 mm x 0.2 mm Weight< 0.7 g MountingAdhesive Tape Mating ConnectorMHF and MHF4-type, Refer to page 5 Cable (Coaxial)0.81mm and 1.13mm Dia., Refer to page 5 Operating Temperature-40 to +85°C Storage Temperature-40 to +85°C Hazardous MaterialsA certificate of conformance is available from the product page on TE website. 2 DUAL BAND WLAN / BLUETOOTH ANTENNA Standard Antenna Solutions Return LossVSWR Efficiency RF DATA (Shown as 2344656-1 : Others can vary with different cable lengths.) Data measured in free space and on plastic board. DATA AND DEVICES /// DUAL BAND WLAN / BLUETOOTH ANTENNA 3 0° 90° 0°90° Azimuth Elevation 2Elevation 1 Test setup Azimuth Plane Elevation 1 Plane Elevation 2 Plane Z Y X Data measured in free space and on plastic board. RADIATION PATTERN (Shown as 2344656-1 : Others can vary with different cable lengths.) DATA AND DEVICES /// DUAL BAND WLAN / BLUETOOTH ANTENNA DUAL BAND WLAN / BLUETOOTH ANTENNA Standard Antenna Solutions 4 DIMENSIONS KEEP OUT AREA DATA AND DEVICES /// DUAL BAND WLAN / BLUETOOTH ANTENNA DUAL BAND WLAN / BLUETOOTH ANTENNA Standard Antenna Solutions NOTES 1. Antenna designed to be mounted on plastic cover. 2. Area in blue indicates Keep Out Area 3. Contact TE if keep out zone cannot be guaranteed. Dimension: mm Diagrams is not into scale Dimension: mm Diagrams is not into scale 5 TE TECHNICAL SUPPORT CENTER USA: +1 (800) 522-6752 Canada: +1 (905) 475-6222 Mexico: +52 (0) 55-1106-0800 Latin/S. America: +54 (0) 11-4733-2200 Germany: +49 (0) 6251-133-1999 UK: +44 (0) 800-267666 France: +33 (0) 1-3420-8686 Netherlands: +31 (0) 73-6246-999 China: +86 (0) 400-820-6015 For phone numbers in other countries, go to te.com/support-center te.com TE Connectivity, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products shouldmake their own evaluation to determine the suitability of each such product for the specific application. © 2020 TE Connectivity Ltd. family of companies All Rights Reserved. 10/2022 PACKAGING DATA AND DEVICES /// DUAL BAND WLAN / BLUETOOTH ANTENNA DUAL BAND WLAN / BLUETOOTH ANTENNA Standard Antenna Solutions 2344656-1501.97 1.13 MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 2344656-21003.94 1.13 MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 2344656-31505.91 1.13 MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 2344656-42007.87 1.13 MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 2344656-5501.97 0.81 MHF4-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) 2344656-61003.94 0.81 MHF4-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) 2344656-71505.91 0.81 MHF4-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) 2344656-82007.87 0.81 MHF4-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) PARTMMINCH CABLE O.D(B), MM CONNECTOR TYPEPART NUMBER IMAGE NUMBER CABLE LENGTH ("A") (ON CABLE)MATING COMPONENTS MATING COMPONENTS TO PART NUMBERS AND DIMENSIONS
Radio Test Report TR-167335.01 Rev 1 Revision History Antenna Pattern TECHNICAL REVIEWER: QUALITY ASSURANCE DELEGATE: 1David Bare2/9/2023Revised to add peak gain for all three channels Made ByDateComments Eight Sleep MODEL(s): 10503 REPORT WRITER: MANUFACTURER: TEST SITE: National Technical Systems - Silicon Valley 41039 Boyce Road Fremont, CA 94538 0M. Birgani2/3/2023 Rev # Mehran Birgani EMC Engineer David W. Bare Chief Engineer David Guidotti Senior Technical Writer TR-167335.01 Rev 1.xlsTest Report Cover PagePage 1 of 5 Antenna Characterisitics Client: Standard: Test Specific Details General Test Configuration BLE Trace Antenna Patterns Maximu m97.7 dbu μV/m ~2.5dBm EIRP Antenna power = 6.2 dBm Peak Antenna Gain: 2.5 ‐ 6.2 = ‐3.7 dBi T-Log Number: TL167335-RA Project Manager: Christine Krebill -Contact: Alex Lednev Radiated 2D Antenna Patterns Objective: Eight SleepPR Number: PR167335 Models: 10503 1/18/2023 Config. Used: 1 Test Engineer: Said Abdelwafi Config Change: - Test Location: Chamber # 7 EUT Voltage: 120V/ 60Hz The antenna height was varied to obtain the maximum level after determining the angle of rotation producing the maximum level. Then the EUT was rotated a gain through 360° to obtain the pattern. The objective of this test session is to perform final qualification testing of the EUT with respect to the specification listed above. The EUT and all local support equipment were located on a 1.5 meter high test table on the turntable for radiated testing. For radiated emissions testing the measurement antenna was located 3 meters from the EUT, unless otherwise noted. Peak measurements performed with: RBW=3MHz, VBW=10MHz, peak detector Date of Test: TR-167335.01 Rev 1.xlsAntenna MeasurementsPage 2 of 5 Antenna Characterisitics Client: Standard: T-Log Number: TL167335-RA Project Manager: Christine Krebill -Contact: Alex Lednev Eight SleepPR Number: PR167335 Models: 10503 Maximum97.2 dbu μV/m ~2.0dBm EIRP Antenna power = 6.7 dBm Peak Antenna Gain: 2 ‐ 6.7 = ‐4.7 dBi Maximu m98.8 dbu μV/m ~3.6dBm EIRP Antenna power = 6.3 dBm Peak Antenna Gain: 3.6 ‐ 6.3 = ‐2.7 dBi TR-167335.01 Rev 1.xlsAntenna MeasurementsPage 3 of 5 Test Equipment Used Manufacturer Description Model #Serial #Cal DateCal Due National Technical Systems NTS EMI Software (rev 2.10)N/AWC022452N/A - Agilent TechnologiesPSA Spectrum AnalyzerE4446AWC055670 24-Oct-22- EMCOHorn Antenna, 1-18 GHz (SA40-Purple) 3115WC062583 12-Sep-22- Hewlett PackardHigh Pass filter, 3.7 GHz P/N 84300- 80038 WC064434 09-Feb-22 09-Feb-23 MITEQPreamplifier, 1-18 GHzAFS44WC080962 18-Jul-22 18-Jul-23 Project Manager: Contact: Client: Eight Sleep Models: 10503 -Alex Lednev PR167335 TL167335-RA Christine Krebill PR Number: T-Log Number: TR-167335.01 Rev 1.xlsTest EquipmentPage 4 of 5 Radio Test Report PR Number: T-Log Number: Project Manager: Contact: End of Report This page is intentionally blank and marks the last page of this test report. Client: Eight SleepPR167335 Models: 10503 TL167335-RA Christine Krebill -Alex Lednev TR-167335.01 Rev 1.xlsEnd of ReportPage 5 of 5
Antenna Information Eight Sleep model 10503 Wi‐Fi Antennas: TE Connectivity model 2344656‐2 (2 are used) Peak gain 2.5 dBi (2.4‐2.5 GHz); 7.0dBi (5.15‐5.875 GHz) The antennas are located inside the product and connected via cable and MHF connector to the SOM PCB. BLE Antenna: On board trace antenna Peak gain ‐2.7 dBi (2.4‐2.48 GHz)
EMC Test Data Client: Contact: Standard: Specific Details General Test Configuration Yes - Eight Sleep, Inc.PR Number: PR167335 Model: Pod Hub T-Log Number: TL167335 Hub 182A5 Project Manager: Christine Krebill Alex Lednev, Patrick McCabeProject Engineer: David Bare FCC part 15.407, RSS-247Class: N/A Summary of Results Maximum Permissible Exposure / SAR Exclusion Objective: Evaluate the RF Exposure requirements per FCC §1.1310, §2.1091 and RSS-102. Date of Test: 1/25/2023 Device complies with Power Density requirements at 20cm separation: If not, required separation distance (in cm): Test Engineer: David W. Bare Calculation uses the free space transmission formula: S = (PG)/(4 πd 2 ) Where: S is power density (W/m 2 ), P is output power (W), G is antenna gain relative to isotropic, d is separation distance from the transmitting antenna (m). Notes The BLE and Wi-Fi radios do not transmit simultaneously. 2.4 GHz and 5 GHz Wi-Fi operating modes are mutually exclusive. Only one band can operate at a time. All calculations use power values at 100% duty cycle. Deviations From The Standard No deviations were made from the requirements of the standard. TL167335 Hub 182A5 SOM x6 NII.xlsMPE CalculationPage 1 of 3 EMC Test Data Client: Contact: Standard: Eight Sleep, Inc.PR Number: PR167335 Model: Pod Hub T-Log Number: TL167335 Hub 182A5 Project Manager: Christine Krebill Alex Lednev, Patrick McCabeProject Engineer: David Bare FCC part 15.407, RSS-247Class: N/A FCC MPE Calculation Use: General Antenna: Maximum 2.5 dBi Wi-Fi Cable Loss AntPower Freq.LossGainat AntEIRP MHzdBmmW*dBdBidBmmW 24026.24.20-3.76.21.78 24406.74.70-4.76.71.58 24806.34.30-2.76.32.29 241223.4218.802.523.4389.05 243723.4218.802.523.4389.05 246223.4218.802.523.4389.05 518014.326.90714.3134.90 520014.326.90714.3134.90 524014.326.90714.3134.90 574523.8239.90723.81202.26 578523.8239.90723.81202.26 582523.8239.90723.81202.26 For the cases where S > the MPE Limit Fre q. MHz 2402 2440 2480 2412 2437 2462 5180 5200 5240 5745 5785 5825 EUTPower Density (S)MPE Limit 1.000 Power (in. Tolerance)at 20 cmat 20 cm mW/cm^2mW/cm^2 0.00041.000 at 95 cm mW/cm^2mW/cm^2 at 95 cmS <= MPE Limit BLE BLE cm 0.00031.000 0.0005 0.2391.0009.8Wi-Fi 0.000 Wi-Fi 0.2391.0009.8Wi-Fi 0.2391.000 0.0001.0000.4 0.40.0001.000 1.0000.4 9.8 Power Density (S)MPE LimitDistance where 0.077 0.0271.0003.3Wi-Fi 1.0005.6Wi-Fi 0.2391.000 0.2391.000 0.239 0.0771.000 0.0771.000 0.077 0.0271.000 1.000 0.0271.000 0.0271.000 BLE 1.000 0.077 1.0005.6Wi-Fi 0.0771.0005.6Wi-Fi 0.0271.0003.3Wi-Fi 1.0003.3Wi-Fi0.027 TL167335 Hub 182A5 SOM x6 NII.xlsMPE CalculationPage 2 of 3 EMC Test Data Client: Contact: Standard: Eight Sleep, Inc.PR Number: PR167335 Model: Pod Hub T-Log Number: TL167335 Hub 182A5 Project Manager: Christine Krebill Alex Lednev, Patrick McCabeProject Engineer: David Bare FCC part 15.407, RSS-247Class: N/A ISED Canada RF Field Strength Power Density Calculation Use: General Antenna: Maximum 2.5 dBi For 300 - 6000 MHz sin gle transmitters (General use) Cable LossAntPower Freq.LossGainat AntEIRP MHzdBmmW*dBdBidBmmW 24026.24.20-3.76.21.78 24406.74.70-4.76.71.58 24806.34.30-2.76.32.29 241223.4218.802.523.4389.05 243723.4218.802.523.4389.05 246223.4218.802.523.4389.05 518014.326.90714.3134.90 520014.326.90714.3134.90 524014.326.90714.3134.90 574523.8239.90723.81202.26 578523.8239.90723.81202.26 582523.8239.90723.81202.26 For the cases where S > the MPE Limit Fre q. MHz 2402 2440 2480 2412 2437 2462 5180 5200 5240 5745 5785 5825 2.3929.7569.9Wi-Fi 2.3929.8039.9Wi-Fi 2.3929.7109.9Wi-Fi 0.7745.4047.6 5.4427.5Wi-Fi 2.3929.803 0.7745.442 0.2689.047 7.6Wi-Fi 2.3929.710 2.3929.756 0.7745.366 EUTPower Density (S)MPE Limit W/m^2 0.0045.351 5.404 0.003 Power Density (S)MPE LimitDistance where 0.2689.071 W/m^2W/m^2cm 0.0035.4090.5BLE 5.4690.6 0.0045.3510.5BLE at 20 cmat 20 cmS <= MPE Limit BLE0.005 Powe r 0.2689.119 5.409 0.0055.469 0.774 at 20 cmat 20 cm W/m^2 0.2689.0473.4Wi-Fi 0.7745.366 Wi-Fi 0.774 0.2689.0713.4Wi-Fi 9.1193.4Wi-Fi0.268 TL167335 Hub 182A5 SOM x6 NII.xlsMPE CalculationPage 3 of 3
41039 Boyce Road 510-578-3500 Phone Fremont, CA. 94538 510-440-9525 Fax File: FR-167335.01-NARF Rev 3 Page 1 EMC Test Report Application for FCC Grant of Equipment Authorization Canada Certification Innovation, Science and Economic Development Canada RSS-Gen Issue 5 / RSS-247 Issue 2 FCC Part 15 Subpart C Model: 10503 IC CERTIFICATION #: 29927-61100001 FCC ID: 2AYXT61100001 APPLICANT: Eight Sleep 212 W 35th, FLoor 4 New York, NY 10123 TEST SITE(S): NTS Labs, LLC 41039 Boyce Road. Fremont, CA. 94538-2435 IC SITE REGISTRATION #: 2845B-3; 2845B-4, 2845B-5, 2845B-7 PROJECT NUMBER: PR167335 REPORT DATE: January 24, 2023 REISSUE DATE: February 17, 2023 FINAL TEST DATES: December 5, 12, 13, 14, 15, 16, 19 and 20, 2022 and January 10, 11, 18 and 19, 2023 TOTAL NUMBER OF PAGES: 102 This report and the information contained herein represent the results of testing of only those articles / products identified in this document and selected by the client. The tests were performed to specifications and/or procedures selected by the client. NTS Labs, LLC makes no representations expressed or implied that such testing fully demonstrates efficiency, performance, reliability, or any other characteristic of the articles being tested, or similar products. This report should not be relied upon as an endorsement or certification by NTS Labs, LLC of the equipment tested, nor does it present any statement whatsoever as to its merchantability or fitness of the test article or similar products, for a particular purpose. This report shall not be reproduced except in full without written approval from NTS Labs, LLC. NTS Labs, LLC Project number PR167335 Report Date: January 24, 2023 Reissue Date: February 17, 2023 Test Report FR-167335.01-NARF Rev 3 Page 2 VALIDATING SIGNATORIES PROGRAM MGR _________________________ David W. Bare Chief Engineer TECHNICAL REVIEWER: _________________________ David W. Bare Chief Engineer FINAL REPORT PREPARER: _________________________ David Guidotti Senior Technical Writer QUALITY ASSURANCE DELEGATE _________________________ Gary Izard Senior Technical Writer NTS Labs, LLC Project number PR167335 Report Date: January 24, 2023 Reissue Date: February 17, 2023 Test Report FR-167335.01-NARF Rev 3 Page 3 REVISION HISTORY Rev# Date Comments Modified By - January 24, 2023 First release 1 February 7, 2023 Some of the page headers were updated to add RSS-247 and remove FCC 15.407 references. Additional information about the test conditions was added on Page 11. The statement about factors on page 21 was revised. David Bare 2 February 9, 2023 Removed all references to 15.407. Added note about cable calibration. David Bare 3 February 17, 2023 Revised antenna gain on page 7, added note about MIMO mode and nominal bandwidths David Bare NTS Labs, LLC Project number PR167335 Report Date: January 24, 2023 Reissue Date: February 17, 2023 Test Report FR-167335.01-NARF Rev 3 Page 4 TABLE OF CONTENTS COVER PAGE ............................................................................................................................................................. 1 VALIDATING SI…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15E | 5.75 GHz - 5.83 GHz | 152.70 mW |