FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Ā© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PD Neurotechnology Ltd./
  3. 2AZDG-PDMONITOR

2AZDG-PDMONITORPDMonitor

PD Neurotechnology Ltd.
PDMonitor - FCC ID 2AZDG-PDMONITOR - PD Neurotechnology Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 01, 2021
Application Purpose
Original Equipment
Date of Application
Jul 01, 2021
Equipment Note
PDMonitor
Frequency Range
2412.00000000 - 2462.00000000
Company
PD Neurotechnology Ltd.
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

pdnfbnitor Ā® INSTRUCTIONS FOR USE Ve怌sion:0.9 I Ma怌ch 20, 2020 powered by pd neurotechnology Ā® medical solutions ENGLISH C E: 怂297 2 Copyright No pa怌t of this publication may be reproduced. ē”˜ansmitted.transcribed. sto怌ed in a怌et怌ieval system. translated into any language or compute怌language.in any fo怌m. by any means. electronic, mechanical. optical. chemical. manual. or otherwise without prior written consent of PD Neurotechnology Ltd. This publication is to be used solely for the pu怌poseof reference or operation of our product. No part of this wo怌kcan be disseminated for other purposes This document may contain technical inaccuracies o怌typog怌aphicalerro怌s. Contents of this document a怌e subject to changes without prior notice. Changes will be incorporated in tutu飞 怌evisionsof this document. This item is compliant with the Medical Device Directive 93/42/EEC of 14 June 1993. II:> 2020 PD Neurotechnology Ltd. All rights reserved. 3 FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Ā· Reorient or relocate the receiving antenna. Ā· Increase the separation between the equipment and receiver. Ā· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Ā· Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Contents Intended Use 6 8.2 Placing the Monitoring Devices on the Contra indications 6 SmartBox after the Reco怌ding Period 26 Warnings 7 8.3 Monito怌ing Device Light lndicato怌 Functionality 32 Precautions Package Contents ļ¼  System Maintenance 32 10 9.1 Cleaning Monitoring Devices 32 PDMonito卢System 14 9.2 Disinfecting Manito怌ing Devices 32 Setu p Instructions 15 9.3 Cleaning the Sma怌tBox 33 7.1 Unpacking the PDMonito怌 Ā® System 15 7.2 Configure SmartBox to the Troubleshooting 33 PD Neu怌otechnologyCloud 16 10.1 Troubleshooting SmartBox 33 7.2.1 Registe怌via Ethe怌net Cable 16 10.2 Troubleshooting Monito怌inq Devices 33 7.2.2 Registe怌via Wi-Fi 16 10.3 Possible Damage 33 7.3 SmartBox Light lndicato怌17 ļ¼  App 34 ID Monitoring Device Usage 19 11. 1 Int怌oduction 34 8.1 Placing the Manito怌ing Devices 11.2 Installation 34 on the Body fo怌a NewReco怌ding 20 11.3 Setup 34 4 11.3.1 SmartBox Internet Connectivity 34 11.16 T怌aininq 42 11.3.2 SmartBox Account Synchronization 34 11. 1 7 Device 43 11.4 Pai怌ing 35 11. 18 Wi-Fi Setup 44 11.5 Welcome Page 36 ļ¼  Mobile Application T怌oubleshooting 45 11.6 Login 36 a.P怌ivacyPolicy 36 ļ¼  System Requirements b. Regist怌ation 37 for You怌Smartphone 45 c. Login 37 11.7 Main Menu 37 '-1' Technical Specifications 46 Warranty and Service 47 11.8 Medication 38 '"7 ļ¼  Disposal 47 11.9 Nut怌ition 38 ļ¼  Version 47 11.10 Invite Physician/ Patient 39 ļ¼  Symbol Table 48 11.11 Status 40 11.12 p怌ofile 41 11.13 Stats 41 11.14 Message of the Day 41 11.15 Ve怌sion 42 5 Intended Use PDMonitor Ā® is a non-invasive continuous monitoring system for patients with Pa怌kinson'sDisease (PD). It is intended to trace, 怌eco怌d, process and sto怌ea variety of moto怌symptomsf怌equentlyoccurring in PD through the continuous use of a set of wearable Monito怌ingDevices. Comprehensive movement information taken f怌om the怌ecordingsas well as information on disease symptoms and their intensities is, following appropriate data processing, sent to the treating physician The system can be used at any stage of the disease afte怌its initial diagnosis and when the patient is under medical t怌eatment.The PDMonito卢systemconsists of the SmartBox. five (5) Monitoring Devices and the PDMonito卢mobileapplication. The PDMonitor Ā® Monitoring Devices. The devices a怌e mounted on the body and acquire body-motion data for assessing the PD moto广 symp to ms . The PDMonito卢Sma怌tBox.The PDMonito卢SmartBoxis a small station for charging the Monitoring Devices. collecting, storing and processing the data from all Monitoring Devices and uploading them to the PD Neurotechnology storage service (Cloud). The PDMonitoäŗ§mobileapplication. The PDMonitoäŗ§mobile application is an electronic diary for medications. diet and symptoms 怌elatedto PD. Moreove怌,the PDMonitor Ā® mobile application p怌ovidesa summary of daily activity as reco怌ded by the PDMonito卢system. Add代ionally,the PDMonito卢device怌ecordingsand symptom assessment can be also used fo怌clinical怌esearchin movement diso怌ders and collection of motion/ movement data. PDMonitoć€ŒĀ® systemshall be used only after the approval of your treating physician who is registered to PD Neurotechnology Ltd. in the use of the PDMonitoć€ŒĀ®system Contraindications <D Do not use this system with a defibrillation device. <D Do not use this system during MRI scanning. <D Do not use du怌ing…

Text truncated - open the document above for the full version.

Cover Letter(s)

PDNeurotechnologyLtd. AgentAuthorization Company:PDNeurotechnologyLtd. Address:3rdFloorPinnersHall,105-108OldBroadStreet,LondonEC2N1ER, UnitedKingdom ProductName:PDMonitor TradeMark:PDMonitor ModelNumber(s):PDMonitor FCCID:2AZDG-PDMONITOR WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2021-06-21 Name:NikosMoschos Title:Director Company:PDNeurotechnologyLtd.

Cover Letter(s)

PDNeurotechnologyLtd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2021-06-21 Subject;RequestforConfidentiality FCCID:2AZDG-PDMONITOR ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:NikosMoschos Title:PDNeurotechnologyLtd.

External Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of5 ExternalPhotosoftheEUT Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of5 Fig.3 Fig.4 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of5 Fig.5 Fig.6 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of5 Fig.7 Fig.8 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of5 Fig.9 Fig.10

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. _____________________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 1 LABELAND LOCATION (Size: L3.0cm x 2.5cm) Material: Tagboard Glue: adhesive sticker Font color: Blue Label color: White Label Location PDMonitor Model No.: PDMonitor FCC ID: 2AZDG-PDMONITOR

Internal Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of11 InternalPhotosoftheEUT Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of11 Fig.3 Fig.4 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of11 Fig.5 Fig.6 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of11 Fig.7 Fig.8 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of11 Fig.9 Fig.10 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page6of11 Fig.11 Fig.12 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page7of11 Fig.13 Fig.14 BT/WIFIAntenna SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page8of11 Fig.15 Fig.16 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page9of11 Fig.17 Fig.18 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page10of11 Fig.19 Fig.20 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page11of11 Fig.21

RF Exposure Info

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 5 FCCRFExposureEvaluation 1.ProductInformation FCCID2AZDG-PDMONITOR Productname PDMonitor Modelnumber PDMonitor Powersupply ForAdapterModel:GSM25E05 Input:AC100-240V,50/60Hz,0.35A Output:DC5V,4A,20WMAX ModulationType GFSK,Ļ€/4-DQPSK,8-DPSKforBluetoothV4.1(DSS) GFSKforBluetoothV4.1(DTS) IEEE802.11b:DSSS(CCK,DQPSK,DBPSK); IEEE802.11g/n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaTypeInternalAntenna AntennaGain1.0dBi(Max.) Hardwareversion0.1.7 Softwareversion1.4.10 FCCOperationfrequency 2402MHz~2480MHz 2412MHz-2462MHz ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevices 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensuresthatthe publicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobiledevicewhereby adistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelowRFPermissibleExposure limitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesumoftheMPE ratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthecalculated/estimated, numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPEratioofeachantennais determinedattheminimumtestseparationdistancerequiredbytheoperatingconfigurationsandexposureconditions ofthehostdevice,accordingtotheratiooffieldstrengthsorpowerdensitytoMPElimit,atthetestfrequency.Either themaximumpeakorspatiallyaveragedresultsfrommeasurementsornumericalsimulationsmaybeusedto determinetheMPEratios.SpatialaveragingdoesnotapplywhenMPEisestimatedusingsimplecalculationsbasedon far-fieldplane-waveequivalentconditions.Theantennainstallationandoperatingrequirementsforthehostdevice mustmeettheminimumtestseparationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneous transmissionoperations,tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequencyElectromagnetic Fields,3kHzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRFExposure ProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 5 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4Ļ€R² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation ArtemisAntennacanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal Identification Antennatypeand antennanumber Operatefrequencyband Maximumantenna gain Note AntennaInternalAntenna 2402MHz~2480MHz 2412MHz-2462MHz 1.0dBi BT/WIFI Antenna SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 3 of 5 6.ConductedPower <BTMaxConductedPower> ModeChannelFrequency(MHz) MaxConductedPower (dBm) GFSK 02402-3.597 392441-3.241 782480-3.675 Ļ€/4DQPSK 02402-2.932 392441-2.471 782480-2.918 8DPSK 02402-2.873 392441-2.409 782480-2.849 <BTLEMaxConductedPower> ModeChannelFrequency(MHz) MaxConductedPower (dBm) GFSK 02402-0.617 192440-1.741 392480-1.603 <2.4GWLANMaxConductedPower> ModeChannelFrequency(MHz) MaxConductedPower (dBm) IEEE802.11b 1241214.83 6243715.75 11246214.59 IEEE802.11g 1241211.94 6243712.53 11246211.64 IEEE802.11nHT20 1241210.27 6243710.80 11246210.00 IEEE802.11nHT40 3242210.65 6243710.65 9245210.30 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 4 of 5 7.ManufacturingTolerance <BT> GFSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)-3.0-3.0-3.0 Tolerance±(dB)1.01.01.0 Ļ€/4DQPSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)-2.0-2.0-2.0 Tolerance±(dB)1.01.01.0 8DPSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)-2.0-2.0-2.0 Tolerance±(dB)1.01.01.0 <BTLE> GFSK(Peak) ChannelChannel0Channel19Channel39 Target(dBm)0-1.0-1.0 Tolerance±(dB)1.01.01.0 <2.4GWIFI> 11B(Peak) ChannelChannel1Channel6Channel11 Target(dBm) 14.015.014.0 Tolerance±(dB) 1.01.01.0 11G(Peak) ChannelChannel1Channel6Channel11 Target(dBm) 11.012.011.0 Tolerance±(dB)1.01.01.0 11N20SISO(Peak) ChannelChannel1Channel6Channel11 Target(dBm) 10.010.010.0 Tolerance±(dB)1.01.01.0 11N40SISO(Peak) ChannelChannel3Channel6Channel9 Target(dBm) 10.010.010.0 Tolerance±(dB)1.01.01.0 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITOR Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapproval…

Text truncated - open the document above for the full version.

Test Report

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page1of14 AppendixB RFTestDataforBTLEV4.1(DTS)(ConductedMeasurement) ProductName:PDMonitor TradeMark:PDMonitor TestModel:PDMonitor EnvironmentalConditions Temperature: 25.9 ļ‚° C RelativeHumidity:54.4% ATMPressure:100.0kPa TestEngineer:BenJin Supervisedby:LiHuan B.1DutyCycle TestModeTestChannelAntDutyCycle[%]Verdict BTLE2440Ant1100PASS #imgrbble1hchnnav SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page2of14 B.2MaximumConductedPeakOutputPower ModeChannelConductPeakPower[dBm]Limit[dBm]Verdict BTLELCH-0.61730PASS BTLEMCH-1.74130PASS BTLEHCH-1.60330PASS TestGraphs LCH MCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page3of14 HCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page4of14 B.3MaximumPowerSpectralDensity ModeChannelPSD[dBm/3KHz]Limit[dBm/3KHz]Verdict BTLELCH-16.1248PASS BTLEMCH-17.0808PASS BTLEHCH-17.0358PASS TestGraphs LCH MCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page5of14 HCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page6of14 B.46dBBandwidth ModeChannel6dBBandwidth[MHz]Limit[MHz]Verdict BTLELCH0.6826 ≄0.5 PASS BTLEMCH0.6846 ≄0.5 PASS BTLEHCH0.6867 ≄0.5 PASS TestGraphs LCH MCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page7of14 HCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page8of14 B.5RFConductedSpuriousEmissions ModeChannelPref[dBm]Max.Level[dBm]Limit[dBm]Verdict BTLELCH-1.675-37.091-21.675PASS BTLEMCH-2.736-37.604-22.736PASS BTLEHCH-2.559-37.963-22.559PASS BTLE_LCH_Graphs Pref/BTLE/LCH Puw/BTLE/LCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page9of14 BTLE_MCH_Graphs Pref/BTLE/MCH Puw/BTLE/MCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page10of14 BTLE_HCH_Graphs Pref/BTLE/HCH Puw/BTLE/HCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page11of14 B.6Band-edgeforRFConductedEmissions ModeChannelCarrierPower[dBm] Max.SpuriousLevel [dBm] Limit[dBm]Verdict BTLELCH-1.593-49.478-21.59PASS BTLEHCH-2.285-49.462-22.29PASS TestGraphs LCH HCH SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page12of14 B.7Restrict-bandband-edgemeasurements Test Mode Test Chann el AntFreq. Power [dBm] Gain Ground Factor E [dBuV/m] Detector Limit [dBuV/ m] Verdi ct BTLE 2402 Ant12310.0-44.002.0053.23PEAK74PASS Ant12310.0-53.412.0043.82AV54PASS Ant12390.0-41.732.0055.50PEAK74PASS Ant12390.0-52.852.0044.38AV54PASS 2480 Ant12483.5-41.962.0055.27PEAK74PASS Ant12483.5-51.852.0045.38AV54PASS Ant12500.0-42.712.0054.52PEAK74PASS Ant12500.0-52.382.0044.85AV54PASS SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page13of14 Restrict-bandband-edgemeasurements_BTLE_2402_Ant1_PEAK Restrict-bandband-edgemeasurements_BTLE_2402_Ant1_AV SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Page14of14 Restrict-bandband-edgemeasurements_BTLE_2480_Ant1_PEAK Restrict-bandband-edgemeasurements_BTLE_2480_Ant1_AV

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 1 of 44 Appendix C RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: PDMonitor Trade Mark: PDMonitor Test Model: PDMonitor Environmental Conditions Temperature: 25.9 ļ‚° C Relative Humidity:54.4% ATM Pressure:100.0 kPa Test Engineer: Ben Jin Supervised by:Li Huan C.1 Duty Cycle Test ModeTest ChannelAntDuty Cycle[%]Verdict 11B2437Ant1100.00PASS 11G2437Ant1100.00PASS 11N20SISO2437Ant1100.00PASS 11N40SISO2437Ant1100.00PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 2 of 44 C.2 Maximum Conducted Output Power ModeChannelMeas.Level [dBm]Limit [dBm]Verdict 11B LCH14.8330PASS MCH15.7530PASS HCH14.5930PASS 11G LCH11.9430PASS MCH12.5330PASS HCH11.6430PASS 11N20SISO LCH10.2730PASS MCH10.8030PASS HCH10.0030PASS 11N40SISO LCH10.6530PASS MCH10.6530PASS HCH10.3030PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 3 of 44 C.3 Maximum Power Spectral Density ModeChannelMeas.Level [dBm/3KHz]Limit [dBm/3KHz]Verdict 11B LCH-11.9488PASS MCH-11.5028PASS HCH-12.3378PASS 11G LCH-19.4958PASS MCH-18.0148PASS HCH-19.7468PASS 11N20SISO LCH-20.3678PASS MCH-19.6308PASS HCH-19.7708PASS 11N40SISO LCH-21.6538PASS MCH-21.2778PASS HCH-22.2318PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 4 of 44 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 5 of 44 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 6 of 44 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 7 of 44 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 8 of 44 11N40SISO/LCH 11N40SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 9 of 44 11N40SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 10 of 44 C.4 6dB Bandwidth ModeChannel6dB Bandwidth [MHz]Limit [MHz]Verdict 11B LCH9.074 ≄0.5 PASS MCH9.080 ≄0.5 PASS HCH9.055 ≄0.5 PASS 11G LCH10.10 ≄0.5 PASS MCH10.10 ≄0.5 PASS HCH10.12 ≄0.5 PASS 11N20SISO LCH10.11 ≄0.5 PASS MCH10.10 ≄0.5 PASS HCH10.08 ≄0.5 PASS 11N40SISO LCH28.84 ≄0.5 PASS MCH28.83 ≄0.5 PASS HCH30.02 ≄0.5 PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 11 of 44 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 12 of 44 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 13 of 44 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 14 of 44 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 15 of 44 11N40SISO/LCH 11N40SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 16 of 44 11N40SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 17 of 44 C.5 RF Conducted Spurious Emissions ModeChannelPref [dBm]Max. Level [dBm]Limit [dBm] Verdic t 11B LCH2.737-38.141-17.263PASS MCH3.76-38.482-16.240PASS HCH2.483-38.049-17.517PASS 11G LCH-4.237-38.746-24.237PASS MCH-3.721-37.659-23.721PASS HCH-4.584-37.419-24.584PASS 11N20 SISO LCH-6.228-37.441-26.228PASS MCH-6.107-38.244-26.107PASS HCH-6.24-37.811-26.240PASS 11N40 SISO LCH-9.35-38.168-29.350PASS MCH-9.353-38.023-29.353PASS HCH-9.828-37.798-29.828PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 18 of 44 11B_LCH_Graphs Pref/11B/LCH Puw/11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 19 of 44 11B_MCH_Graphs Pref/11B/MCH Puw/11B/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 20 of 44 11B_HCH_Graphs Pref/11B/HCH Puw/11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 21 of 44 11G_LCH_Graphs Pref/11G/LCH Puw/11G/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 22 of 44 11G_MCH_Graphs Pref/11G/MCH Puw/11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 23 of 44 11G_HCH_Graphs Pref/11G/HCH Puw/11G/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 24 of 44 11N20SISO_LCH_Graphs Pref/11N20SIS O/LCH Puw/11N20 SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 25 of 44 11N20SISO_MCH_Graphs Pref/11N20 SISO/MCH Puw/11N20 SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 26 of 44 11N20SISO_HCH_Graphs Pref/11N20 SISO/HCH Puw/11N20 SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 27 of 44 11N40SISO_LCH_Graphs Pref/11N40 SISO/LCH Puw/11N40 SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 28 of 44 11N40SISO_MCH_Graphs Pref/11N40 SISO/MCH Puw/11N40 SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AZDG-PDMONITOR Report No.: LCS210315243AEC Page 29 of 44 11N40SISO_HCH_Graphs Pref/11N40 SISO/HCH Puw/11N40 SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABOR…

Text truncated - open the document above for the full version.

Test Report

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of34 FCCTESTREPORT For PDNeurotechnologyLtd. PDMonitor TestModel:PDMonitor Preparedfor:PDNeurotechnologyLtd. Address: 3rdFloorPinnersHall,105-108OldBroadStreet,LondonEC2N1ER, UnitedKingdom Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:March31,2021 Numberoftestedsamples:2 SampleNo.:210315243A-1,210315243A-2 Serialnumber:Prototype DateofTest:March31,2021~April08,2021 DateofReport:April14,2021 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AZDG-PDMONITORReportNo.:LCS210315243AEB Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of34 FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCS210315243AEB DateofIssue.......................................: April14,2021 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandardsā–  PartialapplicationofHarmonisedstandardsā–” Otherstandardtestingmethodā–” Applicant’sName.............................: PDNeurotechnologyLtd. Address................................................: 3rdFloorPinnersHall,105-108OldBroadStreet,LondonEC2N 1ER,UnitedKingdom TestSpecification Standard..............................................: FCCCFR47PART15C(15.247) TestReportFormNo......................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:PDMonitor TradeMark...........................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Nikos Moschos(Director)
[email protected]302651001300Fax: 302651001306

Technical Contact

PD Neurotechnology Ltd.
[email protected]

China

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz37.60 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth.The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.