Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 26, 2021
Application Purpose
Original Equipment
Date of Application
Sep 26, 2021
Equipment Note
Monster GT1
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Monster Intelligent Industrial Co. Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Product name: Monster GT1 Product model: MW218002 Manufacturer: Shenzhen Mosheng Intelligent Industrial Co., Ltd. Address: 3E, Block D, Central Avenue, Intersection of Xixiang Avenue and Baoyuan Road, Laodong Community, Xixiang Street, Baoan District, Shenzhen Contact Person: Po Honghua Email: honghua.wu@mon- ster-china.com Tel: 177 2268 6023 Frequency Range: 2402~2480MHz Max. Transmit Power: 4dbm SIMPLIFIED EU DECLARATION OF CONFORMITY The simplified EU declaration of conformity referred to in Article 10(9) shall be provided as follows: Hereby, Mosheng Intelligent Industrial Co., Ltd. declares that radio equipment type MW218002 is in compliance with Directive 2014/53/EU, and this product is allowed to be used in all EU member states. The full text of the EU declaration of conformity is available at following This product can be used across EU member states. BATTERY WarningCAUTION:RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Voltage range Rated voltage Center frequency Modulation Output power Antenna gain output interface Temperature range The power supply mode Battery spec Wireless module 5V/132mA 3.3V /<60mA 2402-2480MHz GFSK 4dBm -1.0 dBi Contact type 0-70 Battery powered lithium battery220mAh 3.7V 8762CK Specifications

Cover Letter(s)

ShenzhenMonsterIntelligentIndustrialCo.Ltd. AgentAuthorizationLetter (2021-09-18) RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,authorizeMicomLabsInc.,575BoulderCourt,Pleasanton,California94566, USAtoactonourbehalfinallmattersrelatingtoapplicationforequipment authorization,includingthesigningofalldocumentsrelatingtothesematters. Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, HONGHUAWU/ CompanyName:ShenzhenMonsterIntelligentIndustrialCo.Ltd. Address:FlatE,3/F,BuildingD,TheCentralAvenue,XixiangDadaoandBaoyuan RoadCross,LaodongCommunity,XixiangStreet,Bao'anDistrict,Shenzhen.

Cover Letter(s)

DGLGroupLTD. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2021-09-27 Subject;RequestforConfidentiality FCCID:2AANZ2PKR ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram OperationalDescription SWSECURITYDESCRIPTION PartsList Tuneup Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:AmyChao Title:Manager

External Photos

FCCID:2AZDQ-MW218002

ID Label/Location Info

LabelLocation: ProductName:MonsterGT1 ModelNo.:MW218002 FCC:2AZDQ-MW218002

Internal Photos

FCCID:2AZDQ-MW218002 ANT

RF Exposure Info

RFEXPOSUREEVALUATION FCCID:2AZDQ-MW218002 AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeused toevaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF) Radiationasspecifiedin§1.1307(b): RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,using measurementsorcomputersimulation.WhenroutineSARevaluationisnot required,portabletransmitterswithoutputpowergreaterthantheapplicable lowthresholdrequireSARevaluationtoqualifyforTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTuneUp Power(dBm) Distance (mm) Calculation results Limit Operating Mode 24021.651.65±12.65050.5713 BLE24411.21.2 ±1 2.20050.5193 24800.660.66±11.66050.4623 TestResults:PASS.

Test Report

Page1of22 AppendixTestData ReportNo.: 18220WC10156201TestDate:2021.7.13 TestEngineer:Auditor: Temperature:23.3 °C Relative Humidity: 56% Pressure:1012hPa AppendixA:DTSBandwidth TestResult TestModeAntennaChannel DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24020.6682401.6562402.324>=0.5PASS 24400.6962439.6482440.344>=0.5PASS 24800.7082479.6282480.336>=0.5PASS Page2of22 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page3of22 Page4of22 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntennaChannel OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24021.02962401.4882402.518---PASS 24401.02732439.4912440.518---PASS 24801.02882479.4892480.518---PASS Page5of22 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page6of22 Page7of22 AppendixC:Maximumconductedoutputpower TestResult TestModeAntennaChannelResult[dBm]Limit[dBm]Verdict BLE_1MAnt1 24021.65<=30PASS 24401.2<=30PASS 24800.66<=30PASS Page8of22 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page9of22 Page10of22 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaChannelResult[dBm/3-100kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt1 2402-8.31<=8PASS 2440-8.8<=8PASS 2480-9.32<=8PASS Page11of22 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page12of22 Page13of22 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChNameChannelRefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 Low24021.07-44.2<=-18.93PASS High24800.05-48.1<=-19.95PASS Page14of22 TestGraphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 Page15of22 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaChannel FreqRange [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 2402 Reference0.830.83---PASS 30~10000.83-68.24<=-19.17PASS 1000~265000.83-47.43<=-19.17PASS 2440 Reference0.460.46---PASS 30~10000.46-67.46<=-19.55PASS 1000~265000.46-51.48<=-19.55PASS 2480 Reference-0.22-0.22---PASS 30~1000-0.22-65.46<=-20.22PASS 1000~26500-0.22-52.12<=-20.22PASS Page16of22 TestGraphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 Page17of22 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 Page18of22 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 Page19of22 BLE_1M_Ant1_2480_1000~26500 Page20of22 AppendixG:DutyCycle TestResult TestModeAntennaChannel ONTime [ms] Period [ms] XDC [%] xFactor LimitVerdict BLE_1MAnt1 24020.380.620.612961.292.13---PASS 24400.380.620.612961.292.13---PASS 24800.380.630.603260.322.20---PASS Page21of22 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page22of22 ---End---

Test Report

ReportNo.:18220WC10156201FCCID:2AZDQ-MW218002Page1of40 Code:AB-RF-05-a FCCTESTREPORT ClientName:ShenzhenMonsterIntelligentIndustrialCo.Ltd. Address: FlatE,3/F,BuildingD,TheCentralAvenue,Xixiang DadaoandBaoyuanRoadCross,LaodongCommunity, XixiangStreet,Bao'anDistrict,Shenzhen. ProductName:MonsterGT1 Date:Sept.09,2021 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:18220WC10156201FCCID:2AZDQ-MW218002Page2of40 Code:AB-RF-05-a Contents 1.GeneralInformation ............................................................................................................................................... 5 1.1.ClientInformation ....................................................................................................................................... 5 1.2.DescriptionofDevice(EUT) ..................................................................................................................... 5 1.3.AuxiliaryEquipmentUsedDuringTest ................................................................................................... 6 1.4.DescriptionofTestModes ........................................................................................................................ 6 1.5.Listofchannels ........................................................................................................................................... 6 1.6.DescriptionOfTestSetup ......................................................................................................................... 7 1.7.TestEquipmentList .................................................................................................................................... 8 1.8.MeasurementUncertainty ......................................................................................................................... 9 1.9.DescriptionofTestFacility ........................................................................................................................ 9 2.SummaryofTestResults ................................................................................................................................... 10 3.ConductedEmissionTest ................................................................................................................................... 11 3.1.TestStandardandLimit .......................................................................................................................... 11 3.2.TestSetup .................................................................................................................................................. 11 3.3.TestProcedure .......................................................................................................................................... 11 3.4.TestData .................................................................................................................................................... 11 4.RadiationSpuriousEmissionandBandEdge ................................................................................................ 16 4.1.TestStandardandLimit .......................................................................................................................... 16 4.2.TestSetup .................................................................................................................................................. 16 4.3.TestProcedure .......................................................................................................................................... 17 4.4.TestData .................................................................................................................................................... 18 5.MaximumPeakOutputPowerTest .................................................................................................................. 26 5.1.TestStandardandLimit .......................................................................................................................... 26 5.2.TestSetup .................................................................................................................................................. 26 5.3.TestProcedure .......................................................................................................................................... 26 5.4.TestData .................................................................................................................................................... 26 6.6DBOccupyBandwidthTest ............................................................................................................................. 27 6.1.TestStandardandLimit .......................................................................................................................... 27 6.2.TestSetup .................................................................................................................................................. 27 6.3.TestProcedure .......................................................................................................................................... 27 6.4.TestData .................................................................................................................................................... 27 7.PowerSpectralDensityTest .............................................................................................................................. 28 7.1.TestStandardandLimit .......................................................................................................................... 28 7.2.TestSetup .................................................................................................................................................. 28 7.3.TestProcedure .......................................................................................................................................... 28 7.4.TestData ............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2AZDQ-MW218002 PhotoofConductedEmissionMeasurement PhotoofRadiationEmissionTest

Contact Information

Applicant

HONGHUA WU
[email protected]075523725985Fax: 075523725985

Technical Contact

Shenzhen Monster Intelligent Industrial Co. Ltd.
[email protected]

China

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]86-755-26064492Fax: 86-755-26014772

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.50 mW
Confidentiality
Long Term
Grant Notes
Output power listed is maximum conducted power.

Other Applications from Shenzhen Monster Intelligent Industrial Co. Ltd.

MONSTER SOL - FCC ID 2AZDQ-MW215001 - Shenzhen Monster Intelligent Industrial Co. Ltd.
2AZDQ-MW215001

MONSTER SOL

May 09, 2021

Equipment Class

DTS - Digital Transmission System