FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Kaishengwei Technology Co.,Ltd/
  3. 2AZG5YT-89

2AZG5YT-89Robot Vacuum

Shenzhen Kaishengwei Technology Co.,Ltd
Robot Vacuum - FCC ID 2AZG5YT-89 - Shenzhen Kaishengwei Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 19, 2021
Application Purpose
Original Equipment
Date of Application
May 19, 2021
Equipment Note
Robot Vacuum
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Kaishengwei Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Please carefully read the manual before using. If you have any problem, welcome to contact us here : [email protected] 5RERW9DFXXP<7 7KLVHTXLSPHQWFRPSOLHVZLWK)&&UDGLDWLRQH[SRVXUHOLPLWVVHWIRUWKIRUDQXQFRQWUROOHG HQYLURQPHQW7KLVHTXLSPHQWVKRXOGEHLQVWDOOHGDQGRSHUDWHGZLWKPLQLPXPGLVWDQFH FPEHWZHHQWKHUDGLDWRU \RXUERG\ 1MTDPOUBDUPVSTFSWJDFTVQQPSUUFBNJGUIFDMFBOFSGBMMGSPNIJHIQMBDF IJUPSEFGFDUJWF 1MTUBLFUIFCBUUFSZPVUGJSTUJGZPVXBOUUPUISPXUIFDMFBOFSBXBZ 3PVOECSVTIFTY *OQBVTFNPEF 1SPEVDU4QFDJGJDBUJPOT 2500mAh, 7.4V How to Connect With WiFi APP 2. Turn on the cleaner and long press for around 3 seconds un the green light blinking rapidly. 3. Open App, click Add Device 1. Download TuyaSmart from App Store or direclty scan the below QR code to download 4. A. Add ManuallySelect Small Home Appliance /Robot Vacuum red boxes in the below pictureOr ͘ůŝĐŬƵƚŽ^ĐĂŶƵŶƟůƚŚĞŐƌĞĞŶůŝŐŚƚƐƚŽƉƐŇĂƐŚŝŶŐĂŶĚĨĞǁ ƐĞĐŽŶĚƐůĂƚĞƌ͕ƚŚĞƉƉǁŝůůĮŶĚƐǁĞĞƉĞƌ͕ƚŚĞŶĐůŝĐŬEĞdžƚƚŽ get connected. Below is the guide for Add Manually: 3. 4. How to Connect With WiFi APP 6. 6. Click Fast flashing (0.5 seconds/1 Ɵme) 5. 5. /ŶƉƵƚtŝĮƉĂƐƐǁŽƌĚƐ͕ŽŶůLJƐƵƉƉŽƌƚϮ͘κ'tŝĮ 7. 7. Can use App to control the cleaner if the connecƟŽŶ succeed ƵĞƚŽƚŚĞƉƉ;dƵLJĂͿŝƐĂƚŚŝƌĚͲƉĂƌƚLJƉůĂƞŽƌŵĂŶĚŝƚǁŝůů ƵƉŐƌĂĚĞĨƌŽŵƟŵĞƚŽƟŵĞ͘dŚĞĂĐƚƵĂůƉƉŝŶƚĞƌĨĂĐĞŵĂLJ ďĞĚŝīĞƌĞŶƚĨƌŽŵƚŚŝƐŵĂŶƵĂů͕ďƵƚƚŚĞďĂƐŝĐŽƉĞƌĂƟŽŶǁŝůů be the same. Thank you for your understanding! Fault Types Fault Display Solution

Cover Letter(s)

Shenzhen Kaishengwei Technology Co., Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2021-05-17 Subject; Request for Long Term Confidentiality FCC ID: 2AZG5YT-89 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Xufang Lin Title: General manager

Cover Letter(s)

Shenzhen Kaishengwei Technology Co., Ltd 4th floor, building 2, Yufeng Industrial Zone, Shangtang, Minzhi street, Longhua District, Shenzhen, China Statement Product: Robot Vacuum Model: YT-89 Additional Model: YT-88, YT-90 Trademark: N/A We hereby state that All models above are identical in interior structure, electrical circuits and components, and just model names are different for the marketing requirement. Your assistance on this matter is highly appreciated. Yours sincerely, Signature: Date: 2021/05/17 Name: Xufang Lin Company Name : Shenzhen Kaishengwei Technology Co., Ltd Address: 4th floor, building 2, Yufeng Industrial Zone, Shangtang, Minzhi street, Longhua District, Shenzhen, China Tel / Fax: +86-0755-23205963/+86-0755-23205963 E-Mail: [email protected]

Cover Letter(s)

Shenzhen Kaishengwei Technology Co., Ltd Agent Authorization Company: Shenzhen Kaishengwei Technology Co., Ltd Address: 4th floor, building 2, Yufeng Industrial Zone, Shangtang, Minzhi street, Longhua District, Shenzhen, China Product Name: Robot Vacuum Model Number(s): YT-89, YT-88, YT-90 Product Description: Robot Vacuum We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2021-05-17 Name: Xufang Lin Title: General manager Company: Shenzhen Kaishengwei Technology Co., Ltd

External Photos

Page 1 of 5 Appendix C: Photographs of EUT Product: Robot Vacuum Model: YT-89 External Photos Page 2 of 5 Page 3 of 5 Page 4 of 5 Page 5 of 5

ID Label/Location Info

Label Artwork and Location Model: YT-89 Label: Size: L*W=72*50mm Robot Vacuum Model: YT-89 FCC ID: 2AZG5YT-89 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Location

Internal Photos

Page 1 of 6 Appendix C: Photographs of EUT Product: Robot Vacuum Model: YT-89 Internal Photos Page 2 of 6 Antenna Page 3 of 6 Page 4 of 6 Page 5 of 6 Page 6 of 6

RF Exposure Info

Maximum Permissible Exposure Applicable Standard According to §1.1307(b), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. Remark: 1) The maximum output power for antenna is 16.95dBm (49.55mW) at 2412MHz, 5dBi antenna gain(with 3.16 numeric antenna gain.) 2) For mobile or fixed location transmitters, no SAR consideration applied. The minimum separation generally be used is at least 20cm, even if the calculation indicate that the MPE distance would be lesser. Maximum Permissible Exposure output power= 49.55mW Numeric Antenna gain= 3.16 Substituting the MPE safe distance using d=20cm into above equation. Yields: S=0.000199*P*G Where P=Power in mW G=Numeric antenna gain S=Power density in mW/cm 2 Power density= 0.031159mW/cm 2 (For mobile or fixed location transmitters, the maximum power density is 1.0 mW/cm 2 even if the calculation indicates that the power density would be larger.)

Test Report

Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TEST REPORT FCC ID: 2AZG5YT-89 Product: Robot Vacuum Model No.: YT-89 Additional Model No.: YT-88, YT-90 Trade Mark: N/A Report No.: TCT210204E009 Issued Date: May 12, 2021 Issued for: Shenzhen Kaishengwei Technology Co., Ltd 4th floor, building 2, Yufeng Industrial Zone, Shangtang, Minzhi street, Longhua District, Shenzhen, China Issued By: Shenzhen Tongce Testing Lab. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China TEL: +86-755-27673339 FAX: +86-755-27673332 Note: This report shall not be reproduced except in full, without the written approval of Shenzhen Tongce Testing Lab. This document may be altered or revised by Shenzhen Tongce Testing Lab. personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT210204E009 Page 2 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TABLE OF CONTENTS 1. Test Certification ..................................................................................... 3 2. Test Result Summary .............................................................................. 4 3. EUT Description ....................................................................................... 5 4. General Information ................................................................................. 7 4.1. Test environment and mode ................................................................................. 7 4.2. Description of Support Units ................................................................................ 8 5. Facilities and Accreditations .................................................................. 9 5.1. Facilities ................................................................................................................. 9 5.2. Location ................................................................................................................. 9 5.3. Measurement Uncertainty ..................................................................................... 9 6. Test Results and Measurement Data ................................................... 10 6.1. Antenna requirement .......................................................................................... 10 6.2. Conducted Emission ........................................................................................... 11 6.3. Maximum Conducted (Average) Output Power ................................................ 12 6.4. Emission Bandwidth ........................................................................................... 16 6.5. Power Spectral Density ....................................................................................... 17 6.6. Conducted Band Edge and Spurious Emission Measurement ....................... 18 6.7. Radiated Spurious Emission Measurement ...................................................... 20 Appendix A: Test Result of Conducted Test Appendix B: Photographs of Test Setup Appendix C: Photographs of EUT Report No.: TCT210204E009 Page 3 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 1. Test Certification Product: Robot Vacuum Model No.: YT-89 Additional Model No.: YT-88, YT-90 Trade Mark: N/A Applicant: Shenzhen Kaishengwei Technology Co., Ltd Address: 4th floor, building 2, Yufeng Industrial Zone, Shangtang, Minzhi street, Longhua District, Shenzhen, China Manufacturer: Shenzhen Kaishengwei Technology Co., Ltd Address: 4th floor, building 2, Yufeng Industrial Zone, Shangtang, Minzhi street, Longhua District, Shenzhen, China Date of Test: Feb. 05, 2021 –May 11, 2021 Applicable Standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 FCC KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10:2013 The above equipment has been tested by Shenzhen Tongce Testing Lab. and found compliance with the requirements set forth in the technical standards mentioned above. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Tested By: Date: May 11, 2021 Brave Zeng Reviewed By: Date: May 12, 2021 Beryl Zhao Approved By: Date: May 12, 2021 Tomsin Report No.: TCT210204E009 Page 4 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 2. Test Result Summary Requirement CFR 47 Section Result Antenna requirement §15.203/§15.247 (c) PASS AC Power Line Conducted Emission §15.207 PASS Conducted Peak Output Power §15.247 (b)(3) PASS 6dB Emission Bandwidth §15.247 (a)(2) PASS Power Spectral Density §15.247 (e) PASS Band Edge §15.247(d) PASS Spurious Emission §15.205/§15.209 PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. Report No.: TCT210204E009 Page 5 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 3. EUT Description Product: Robot Vacuum Model No.: YT-89 Additional Model No.: YT-88, YT-90 Trade Mark: N/A Operation Frequency: 2412MHz~2462MHz (802.11b/802.11g/802.11n(HT20)) 2422MHz~2452MHz (802.11n(HT40)) Channel Separation: 5MHz Number of Channel: 11 for 802.11b/802.11g/802.11n(HT20) 7 for 802.11n(HT40) Modulation Technology: (IEEE 802.11b) Direct Sequence Spread Spectrum (DSSS) Modulation Technology: (IEEE 802.11g/802.11n) Orthogonal Frequency Division Multiplexing(OFDM) Data speed (IEEE 802.11b): 1Mbps, 2Mbps, 5.5Mbps, 11Mbps Data speed (IEEE 802.11g): 6Mbps, 9Mbps, 12Mbps, 18Mbps, 24Mbps, 36Mbps, 48Mbps, 54Mbps Data speed (IEEE 802.11n): Up to 150Mbps Antenna Type: PCB Antenna Antenna Gain: 5dBi Power Supply: R…

Text truncated - open the document above for the full version.

Test Report

Report No.: TCT210204E009 Page 51 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_2462 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 Report No.: TCT210204E009 Page 52 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 11N40SISO_Ant1_2437 Report No.: TCT210204E009 Page 53 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N40SISO_Ant1_2452 Report No.: TCT210204E009 Page 54 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Band edge measurements Test Result Test Mode Antenna Ch Name Channel Ref Level [dBm] Result [dBm] Limit [dBm] Verdict 11B Ant1 Low 2412 7.25 -34.23 <=-22.75 PASS High 2462 6.97 -52.22 <=-23.03 PASS 11G Ant1 Low 2412 0.46 -32.47 <=-29.54 PASS High 2462 0.86 -49.2 <=-29.14 PASS 11N20SISO Ant1 Low 2412 0.42 -32.54 <=-29.59 PASS High 2462 0.80 -47.89 <=-29.2 PASS 11N40SISO Ant1 Low 2422 -2.93 -44.05 <=-32.93 PASS High 2452 -2.48 -44.82 <=-32.48 PASS Test Graphs 11B_Ant1_Low_2412 11B_Ant1_High_2462 11G_Ant1_Low_2412 Report No.: TCT210204E009 Page 55 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_High_2462 11N20SISO_Ant1_Low_2412 11N20SISO_Ant1_High_2462 Report No.: TCT210204E009 Page 56 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N40SISO_Ant1_Low_2422 11N40SISO_Ant1_High_2452 Report No.: TCT210204E009 Page 57 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Conducted Spurious Emission Test Result Test Mode Antenna Channel Freq Range [Mhz] Ref Level [dBm] Result [dBm] Limit [dBm] Verdict 11B Ant1 2412 Reference 7.28 7.28 --- PASS 30~1000 30~1000 -67.532 <=-22.72 PASS 1000~26500 1000~26500 -42.624 <=-22.72 PASS 2437 Reference 6.93 6.93 --- PASS 30~1000 30~1000 -68.305 <=-23.068 PASS 1000~26500 1000~26500 -42.718 <=-23.068 PASS 2462 Reference 6.87 6.87 --- PASS 30~1000 30~1000 -67.728 <=-23.128 PASS 1000~26500 1000~26500 -41.947 <=-23.128 PASS 11G Ant1 2412 Reference 0.44 0.44 --- PASS 30~1000 30~1000 -68.216 <=-29.561 PASS 1000~26500 1000~26500 -43.012 <=-29.561 PASS 2437 Reference 0.88 0.88 --- PASS 30~1000 30~1000 -67.993 <=-29.116 PASS 1000~26500 1000~26500 -42.23 <=-29.116 PASS 2462 Reference 0.58 0.58 --- PASS 30~1000 30~1000 -68.471 <=-29.423 PASS 1000~26500 1000~26500 -42.541 <=-29.423 PASS 11N20SISO Ant1 2412 Reference 0.01 0.01 --- PASS 30~1000 30~1000 -68.867 <=-29.987 PASS 1000~26500 1000~26500 -42.219 <=-29.987 PASS 2437 Reference 0.25 0.25 --- PASS 30~1000 30~1000 -68.567 <=-29.747 PASS 1000~26500 1000~26500 -42.149 <=-29.747 PASS 2462 Reference 0.29 0.29 --- PASS 30~1000 30~1000 -67.845 <=-29.71 PASS 1000~26500 1000~26500 -42.728 <=-29.71 PASS 11N40SISO Ant1 2422 Reference -2.76 -2.76 --- PASS 30~1000 30~1000 -68.258 <=-32.755 PASS 1000~26500 1000~26500 -42.401 <=-32.755 PASS 2437 Reference -2.68 -2.68 --- PASS 30~1000 30~1000 -67.397 <=-32.684 PASS 1000~26500 1000~26500 -42.597 <=-32.684 PASS 2452 Reference -2.56 -2.56 --- PASS 30~1000 30~1000 -68.272 <=-32.558 PASS 1000~26500 1000~26500 -42.43 <=-32.558 PASS Report No.: TCT210204E009 Page 58 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Test Graphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 Report No.: TCT210204E009 Page 59 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 11B_Ant1_2437_1000~26500 11B_Ant1_2462_0~Reference Report No.: TCT210204E009 Page 60 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11B_Ant1_2462_30~1000 11B_Ant1_2462_1000~26500 11G_Ant1_2412_0~Reference Report No.: TCT210204E009 Page 61 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_2412_30~1000 11G_Ant1_2412_1000~26500 11G_Ant1_2437_0~Reference Report No.: TCT210204E009 Page 62 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_2437_30~1000 11G_Ant1_2437_1000~26500 11G_Ant1_2462_0~Reference Report No.: TCT210204E009 Page 63 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_2462_30~1000 11G_Ant1_2462_1000~26500 11N20SISO_Ant1_2412_0~Reference Report No.: TCT210204E009 Page 64 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N20SISO_Ant1_2412_30~1000 11N20SISO_Ant1_2412_1000~26500 11N20SISO_Ant1_2437_0~Reference Report No.: TCT210204E009 Page 65 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N20SISO_Ant1_2437_30~1000 11N20SISO_Ant1_2437_1000~26500 11N20SISO_Ant1_2462_0~Reference

Test Report

Report No.: TCT210204E009 Page 66 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N20SISO_Ant1_2462_30~1000 11N20SISO_Ant1_2462_1000~26500 11N40SISO_Ant1_2422_0~Reference Report No.: TCT210204E009 Page 67 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N40SISO_Ant1_2422_30~1000 11N40SISO_Ant1_2422_1000~26500 11N40SISO_Ant1_2437_0~Reference Report No.: TCT210204E009 Page 68 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N40SISO_Ant1_2437_30~1000 11N40SISO_Ant1_2437_1000~26500 11N40SISO_Ant1_2452_0~Reference Report No.: TCT210204E009 Page 69 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N40SISO_Ant1_2452_30~1000 11N40SISO_Ant1_2452_1000~26500 Report No.: TCT210204E009 Page 70 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Duty Cycle Test Result Test Mode Antenna Channel Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] Limit Verdict 11B Ant1 2412 50.00 50.00 100.00 --- PASS 2437 50.00 50.00 100.00 --- PASS 2462 50.00 50.00 100.00 --- PASS 11G Ant1 2412 50.00 50.00 100.00 --- PASS 2437 50.00 50.00 100.00 --- PASS 2462 50.00 50.00 100.00 --- PASS 11N20SISO Ant1 2412 50.00 50.00 100.00 --- PASS 2437 50.00 50.00 100.00 --- PASS 2462 50.00 50.00 100.00 --- PASS 11N40SISO Ant1 2422 50.00 50.00 100.00 --- PASS 2437 50.00 50.00 100.00 --- PASS 2452 50.00 50.00 100.00 --- PASS Test Graphs 11B_Ant1_2412 11B_Ant1_2437 Report No.: TCT210204E009 Page 71 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11B_Ant1_2462 11G_Ant1_2412 11G_Ant1_2437 11G_Ant1_2462 Report No.: TCT210204E009 Page 72 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Report No.: TCT210204E009 Page 73 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N40SISO_Ant1_2422 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 Report No.: TCT210204E009 Page 74 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT210204E009 Page 75 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Appendix B: Photographs of Test Setup Product: Robot Vacuum Model: YT-89 Radiated Emission Report No.: TCT210204E009 Page 76 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Conducted Emission Report No.: TCT210204E009 Page 77 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Appendix C: Photographs of EUT Product: Robot Vacuum Model: YT-89 External Photos Report No.: TCT210204E009 Page 78 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT210204E009 Page 79 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT210204E009 Page 80 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT210204E009 Page 81 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT210204E009 Page 82 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Product: Robot Vacuum Model: YT-89 Internal Photos Report No.: TCT210204E009 Page 83 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT210204E009 Page 84 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT210204E009 Page 85 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT210204E009 Page 86 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT210204E009 Page 87 of 87 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com *****END OF REPORT*****

Test Setup Photos

Page 1 of 2 Appendix B: Photographs of Test Setup Product: Robot Vacuum Model: YT-89 Radiated Emission Page 2 of 2 Conducted Emission

Contact Information

Applicant

Xufang Lin(General manager)
[email protected]+86-0755-23205963Fax: +86-0755-23205963

Technical Contact

Shenzhen Kaishengwei Technology Co., Ltd
[email protected]

China

Test Firm

SHENZHEN TONGCE TESTING LABBeryl Zhao
[email protected]+8675527208735

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz49.50 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.