Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
HanntoTechnologyCo.,Ltd. CertificationDesignatingaUSAgentforServiceofProcess To:FederalCommunicationsCommissionDate:03-11-2025 7435OaklandMillsRoad,Columbia,MD21046,USA Ref:AttestationStatement–Part2.911(d)(7)filing FCCID:2AZHDDMP130 HanntoTechnologyCo.,Ltd.(“theapplicant”)certifiesthatasofthedateofthefilingoftheapplication, JOCAustraliaInc(“theagent”)isourdesignatedU.S.agent. Weacknowledgetheapplicant’sconsentandthedesignatedagentforserviceofprocess’sobligationto acceptserviceofprocess.Theapplicantacceptstomaintainanagentforserviceofprocessfornolessthan threeyearafterthegranteehasterminatedallmarketingandimportationortheconclusionofany Commission-relatedproceedinginvolvingtheequipment.Theapplicantfurtheracknowledgesitisour responsibilitytoinformtheFCCwhenevertheagentinformationchanges. APPLICANT CompanyName:HanntoTechnologyCo.,Ltd. ContactPerson:JingYe Address:Room704,Buliding1,No.88,ShengrongRoad,Pudong,Shanghai,China Tel.:+8618621992750 Email:[email protected] FCCFRN:0030757009 U.S.Agent CompanyName:JOCAustraliaInc ContactPerson:Benjamin.Smith/VicePresident Address:17800CASTLETONSTSTE665,CITYOFINDUSTRY,CA91748UnitedStatesofAmerica Tel.:+1(626)3413408 Email:[email protected] FCCFRN:0033379421 Sincerelyyours, TheApplicantTheAgent CompanyNameHanntoTechnologyCo.,Ltd.JOCAustraliaInc ContactPersonJingYeBenjamin.Smith/VicePresident Signature
Hannto Technology Co.,Ltd. Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 10/20/2025 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2AZHDDMP130 Hannto Technology Co.,Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Jing Ye Title: Quality Manager Address: Room 704, Buliding 1, No. 88, Shengrong Road, Pudong, Shanghai, China Tel.: +86 18621992750 Email: [email protected]
Hannto Technology Co.,Ltd. Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 10/20/2025 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2AZHDDMP130 Hannto Technology Co.,Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Jing Ye Title: Quality Manager Address: Room 704, Buliding 1, No. 88, Shengrong Road, Pudong, Shanghai, China Tel.: +86 18621992750 Email: [email protected]
TCB Authority to Act as Agent Number: MS-0045317 Revision: 0 Effective date: Oct 8, 2021 Page 1 of 1 Authority to Act as Agent Date: 20 Oktober 2025 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint Mr. Tianlin Li/TUV Rheinland (Shanghai) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Hannto Technology Co.,Ltd. / Room 704, Buliding 1, No. 88, Shengrong Road, Pudong, Shanghai, China For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 12 Months Agreement is valid for 12 months from the above date. By: ____________ Jing Ye (Signature) (Print name) Quality Manager +86 18621992750 (Title: (Telephone) On behalf of: Hannto Technology Co.,Ltd. (Company Name)
Hannto Technology Co.,Ltd. MS-0044715 Page 1 of 1 Revision 1 Date: __2025-10-20__ Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2AZHDDMP130 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Construction Hannto Technology Co.,Ltd. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: ____________________ _______Jing Ye____________ (Signature) (Print name) Tel: +86 18621992750 Email: [email protected]
part number Design by CU002-80006 label Name Label-Product-SN-Overseas zhangyueying Date 2025.10.20 更新FCC ID confidential Rev. V0.7 Notes Matt film or Matt Oil on label top ColorSpec 3 x R0.7 mm 46.9 mm 50.8mm pantone cool gray 9C Pantone cool gray 2C MAC: XXXXXXXXXXXX SN: 1250LJ5900001 SKU: DMP130J#WW1 Production Date: MM/YYYY Name: Portable Photo Printer Input: 5 V=3 A Model: DMP130 FCC ID: 2AZHDDMP130 Email: [email protected] Hannto Technology Co., Ltd. Made in China Address: Room 704, Building 1, No. 88, Shengrong Road, Pudong, Shanghai, China Pearl N200 Pro Portable Photo Printer R XXX-XXXXXX Insert the photo paper: Place the photo paper with the printed side facing upward and the perforated line facing the output tray. Paper slot capacity: 10 sheets ! MAC: XXXXXXXXXXXX SN: 1250LJ5900001 SKU: DMP130J#WW1 Production Date: MM/YYYY Name: Portable Photo Printer Input: 5 V=3 A Model: DMP130 FCC ID: 2AZHDDMP130 Email: [email protected] Hannto Technology Co., Ltd. Made in China Address: Room 704, Building 1, No. 88, Shengrong Road, Pudong, Shanghai, China Pearl N200 Pro Portable Photo Printer R XXX-XXXXXX Insert the photo paper: Place the photo paper with the printed side facing upward and the perforated line facing the output tray. Paper slot capacity: 10 sheets ! Label Location
Safety Human Exposure 1.1 Radio Frequency Exposure Compliance 1.1.1 Electromagnetic Fields RESULT: Pass Test item : Portable Photo Printer Identification / Type No. : DMP130 FCC ID : 2AZHDDMP130 Test standard : CFR47 FCC Part 2: Section 2.1093 CFR47 FCC Part 1: Section 1.1310 FCC KDB Publication 447498 D04 V01 ➢ Product Classification This device defined as a transmitting device designed to be used in other than f ixed locations and to generally be used in such a way that the RF source's radiating structure(s) is/are at least 20 centimeters between the body of the user. Max 0.51 dBi ➢ Radio Frequency Exposure Limit For FCC: According to FCC KDB # 447498 D04 V01, Clause Appendix B and 1.1307(b)(3)(i)(B) The available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold Pth (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by: a) EUT RF Exposure Evaluation standalone operations FCC Mode Frequency [GHz] *Measured RF Output Power [dBm] Antenna Gain [dBi] RF Output Power [mW] EIRP [mW] d [cm] Limit-P th [mW] BR/EDR 2.441 0.40 0.51 1.10 1.23 0.50 2.75 BLE 2.440 1.00 0.51 1.26 1.42 0.50 2.75 Note: BR/EDR RF Output Power: Ref er CN256888 002 BLE RF Output Power: Ref er CN256888 001 ➢ Conclusion The distance between antenna and human is larger than 0.5cm in the normal use. Theref ore, the maximum calculations result of above are meet the requirement of Radio Frequency Exposure limit.
REV:A0 天线规格书 ANTENNASPECIFICATION 天线型号: AntennaModel DMP130-ANT 天线类型: AntennaType PCBAntenna 品牌: Brand 汉图/Hannto 制造商: Manufacturer 上海汉图科技有限公司 HanntoTechnologyCo.,Ltd. 制造商地址: Manufacturer Address 中国(上海)自由贸易试验区盛荣路88 弄1号704室 Room704,Building1,No.88,Shengrong Road,Pudong,200120Shanghai,P.R.China 编制Prepared审核Checked批准Approved 张云杰 2025.09.18 叶晶 2025.09.19 叶晶 2025.09.19 REV:A0 1 1.天线外观Antennaappearance 大小/Size:12mmx4mm 2.天线应用Antennaapplication PCBAntenna(Model:DMP130-ANT) 适用于以下机型: 口袋照片打印机 Applicableto: PortablePhotoPrinter 3.性能参数 频率范围 2402~2483.5MHZ 最大增益 0.26dBi 辐射方向全向 尺寸参数 12mmx4mm 天线类型 PCBAntenna 工作温度-40°C~85°C 工作湿度 20~85% REV:A0 2 4.测试环境 5.天线效率及增益数据 TestItemTestStateFrequency (MHz) Efficiency (%) Gain(dBi) Note GainFS 240031.23-0.26 / 241031.41-0.01 242031.79-0.29 243032.20-0.08 244029.54-0.50 245029.45-0.18 246028.10-0.10 247026.96-0.10 248028.190.26 249027.490.13 250028.050.51 REV:A0 3 6.2DPlot REV:A0 4 7.3DPlot REV:A0 5 REV:A0 6 REV:A0 7
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN256888 001 Auftrags-Nr.: Order no.: 326130962 Seite 1 von 40 Page 1 of 40 Kunden-Referenz-Nr.: Client reference no.: / Auftragsdatum: Order date: 2025-09-18 Auftraggeber: Client: Hannto Technology Co., Ltd. Room 704, Building 1, No. 88, Shengrong Road, Pudong, Shanghai, China Prüfgegenstand: Test item: Portable Photo Printer Bezeichnung / Typ-Nr.: Identification / Type no.: DMP130 Auftrags-Inhalt: Order content: Complete test Prüfgrundlage: Test specification: FCC CFR47 Part 15, Subpart C Section 15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+Errata to C63.10a-2024 Wareneingangsdatum: Date of sample receipt: 2025-09-22 Prüfmuster-Nr.: Test sample no: A004097853-001 Prüfzeitraum: Testing period: 2025-10-16~2025-10-28 Ort der Prüfung: Place of testing: TÜV Rheinland (Shanghai) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shanghai) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Tianlin Li genehmigt von: authorized by: X Signed by: Yanli Fan Datum: Date: 2025-11-19 Ausstellungsdatum: Issue date: 2025-11-19 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2AZHDDMP130 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shanghai) Co., Ltd. 1st Floor of No. 10, No.153, 165, 177, 179, 189, Lane 777, West Guangzhong Road, Jingan District, Shanghai Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN256888 001 Test report no.: Seite 2 von 40 Page 2 of 40 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurement results, in this test rep…
Text truncated - open the document above for the full version.
TUV Building I, No.177, Lane 777, West Guangzhong · Shanghai, 200072 · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.30 mW |