Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RFA Brands LLC. Agent Authorization Company: RFA Brands LLC. Address: 123W.Brown Street, Birmingham MI 48009, USA Product Name: Power Bank Trade Mark: mycharge Model Number(s): PPW10KK-A FCC ID: 2AZIG-PPW10KK-A We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2021-04-22 Name: Nicholas Howel Title: Engineer Company: RFA Brands LLC.
RFA Brands LLC. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2021-4-22 Subject; Request for Confidentiality FCC ID: 2AZIG-PPW10KK-A To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Nicholas Howel Title: Engineer
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 4 1. EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 4 Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 4 Fig. 5 Fig. 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 4 Fig. 7 Fig. 8
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L: 2.5cm*W: 1.0cm Label Location Power Bank Model No.: PPW10KK-A FCC ID : 2AZIG-PPW10KK-A
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 5 1. INTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Coil Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 5 Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 5 Fig. 5 Fig. 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 5 Fig. 7 Fig. 8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 5 Fig. 9 Fig. 10
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A ___________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 15 RF Exposure Evaluation Report 1. Product Information FCC ID: 2AZIG-PPW10KK-A Product Name Power Bank Model Number PPW10KK-A Power Supply Input: 100-240V~, 50/60Hz, 0.3A USB-C Output: 5V2.4A USB-A Output: 5V2.4A Wireless charging standard output power: 5W Total maximum output: 12W Battery: 3.7V, 10000mAh Modulation Type Continuous Wave Frequency Range 110.0~205.0KHz Operation Frequency 125.0 KHz Antenna Type Coil Antenna Hardware version MP5037-55C2 Software version CV90330-F414 Accessories / Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Consumer wireless power transfer devices approved under Part 18 in some cases have to demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed according to the operating configurations of the wireless system and the exposure conditions of users and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at maximum output power. The RF exposure requirements must be determined in conjunction with the device operating characteristics, according to the mobile and portable exposure requirements in Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the FCC rules. 2) Based on the design and implementation of the power transfer application, it must be clearly identified if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of the rules may apply. 3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A ___________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 15 assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. 4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements. Existing SAR systems and test procedures are generally intended for measurements above 100 MHz. While numerical modeling can be an alternative, the constraints of substantial computational resources at low frequencies could introduce further limitations. Under these circumstances, including operations below 100 kHz, the Commission may consider a combination of analytical analysis, field strength, radiated and conducted power measurements, in conjunction with some limited numerical modeling to assess compliance. 5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation they should contact the FCC Laboratory with sufficient system operating configuration details to determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures. Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons, information on device design, implementation, operating configurations, exposure conditions of users and bystanders are needed to determine the evaluation and testing requirements. In addition, the influence of nearby objects may also need consideration according to the wireless power transfer system implementation; for example, the effects of placing the device, its coils or radiating elements on or near metallic surfaces 3. Evaluation Limit 3.1 Refer evaluation method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices FCC CFR 47 part 18.107:Indusial, Scientific, and Medical Equipment 3.2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 300-1,500 / / f/300 6 1,500-100,000 / / 5 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A ___________________________________________________________________________ This report sh…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A Report No.: LCS210317107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 22 FCC TEST REPORT For RFA Brands LLC Power Bank Test Model: PPW10KK-A Prepared for : RFA Brands LLC Address : 123W.Brown Street, Birmingham MI 48009, USA Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : April 01, 2021 Number of tested samples : 1 Sample number : 210317107A Serial number : Prototype Date of Test : April 01, 2021 ~ April 09, 2021 Date of Report : April 14, 2021 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A Report No.: LCS210317107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 22 FCC TEST REPORT FCC CFR 47 PART 18 Report Reference No. ................ : LCS210317107AEA Date Of Issue ................................. : April 14, 2021 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : RFA Brands LLC Address .......................................... : 123W.Brown Street, Birmingham MI 48009, USA Test Specification Standard ......................................... : FCC CFR 47 PART 18 Test Report Form No. .................... : LCSEMC-1.0 TRF Originator................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : Power Bank Trade Mark ..................................... : mycharge Test Model ...................................... : PPW10KK-A Power Supply ................................. : Please Refer to Page 6 Result ........................................... : Positive Compiled by: Supervised by: Approved by: Linda He/ Administrators Jin Wang/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A Report No.: LCS210317107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 22 FCC TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS210317107AEA April 14, 2021 Date of issue Test Model.............................. : PPW10KK-A EUT......................................... : Power Bank Applicant............................... : RFA Brands LLC Address.................................. : 123W.Brown Street, Birmingham MI 48009, USA Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Shenzhen Trusda Industrial Co., Ltd. Address................................... : 201&301, Building4, Lianchuang Technology Park, No 21 Bulan Road, Xialilang Community, Nanwan street, Longgang District, Shenzhen, China Telephone............................... : / Fax.......................................... : / Factory................................... : RFA Brands LLC Address................................... : 123W.Brown Street, Birmingham MI 48009, USA Telephone............................... : / Fax.......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A Report No.: LCS210317107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 22 Revision History Revision Issue Date Revisions Revised By 000 April 14, 2021 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A Report No.: LCS210317107AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 22 TABLE OF CONTENTS 1. GENERAL INFORMATION ...................................................................................................... 6 1.1 Description of Device (EUT) ........................................................................................................... 6 1.2 Support equipment List .................................................................................................................... 6 1.3 External I/O Cable ............................................................................................................................ 6 1.4 Description of Test Facility .............................................................................................................. 6 1.5 Statement of the Measurement Uncertainty ................................................................................. 7 1.6 Measuremen…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 2 Appendix A Photographs of Test Setup Conducted Emission Radiated Emission below 30MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZIG-PPW10KK-A _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 2 Radiated Emission below 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.11 MHz - 0.205 MHz | - |

Power Bank
Equipment Class
8CC - Part 18 Consumer Device