FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. NIMBLE FOR GOOD, PBC./
  3. 2AZIO-NBBTATL

2AZIO-NBBTATLLuggage Tag

NIMBLE FOR GOOD, PBC.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 14, 2026
Application Purpose
Original Equipment
Equipment Note
Luggage Tag
Frequency Range
2402.00000000 - 2480.00000000
Company
NIMBLE FOR GOOD, PBC.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

NIMBLE FOR GOOD, PBC. Covered Equipment Certification Attestation Letter 2026-08-07 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID:2AZIO-NBBTATL NIMBLE FOR GOOD, PBC. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. NIMBLE FOR GOOD, PBC. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. NIMBLE FOR GOOD, PBC. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Julie Kao Title: Manager Company Name: NIMBLE FOR GOOD, PBC. Address: 1008 Brioso Drive Costa Mesa, CA 92627, United States Phone: 06262973580 E-Mail: [email protected] Date: 2026-08-07

Attestation Statements

NIMBLE FOR GOOD, PBC. U.S. Agent Designation for Service of Process - Certification Attestation Letter NIMBLE FOR GOOD, PBC. 1008 Brioso Drive Costa Mesa, CA 92627, United States Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 2026-08-07 Attestation Statement according to 2.911(d)(7) FCC ID: 2AZIO-NBBTATL TO WHOM IT MAY CONCERN: We, NIMBLE FOR GOOD, PBC. designate ourselves to act as U.S. agent for service of process. NIMBLE FOR GOOD, PBC. hereby acknowledges the obligation of the U.S. agent for service of process. Further NIMBLE FOR GOOD, PBC. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Sincerely Applicant Signed/ Designated Agent Signed: Signature: Company name: NIMBLE FOR GOOD, PBC. FRN: 0030768691 Address: 1008 Brioso Drive Costa Mesa, CA 92627, United States Contact Person: Julie Kao Telephone No: 06262973580 Email: [email protected]

Cover Letter(s)

NIMBLE FOR GOOD, PBC. 2026-08-07 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Damon Hu, Guangdong Dongdian Testing Service Co.,Ltd.( Unit 2, Building 1, No.17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808), to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Julie Kao Title: Manager Company Name: NIMBLE FOR GOOD, PBC. Address: 1008 Brioso Drive Costa Mesa, CA 92627, United States Phone: 06262973580 E-Mail: [email protected] Date: 2026-08-07

Cover Letter(s)

NIMBLE FOR GOOD, PBC. 2026-08-07 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY – FCC FCC ID: 2AZIO-NBBTATL Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☐ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Julie Kao Title: Manager Company Name: NIMBLE FOR GOOD, PBC. Address: 1008 Brioso Drive Costa Mesa, CA 92627, United States Phone: 06262973580 E-Mail: [email protected] NIMBLE FOR GOOD, PBC. Date: 2026-08-07

ID Label/Location Info

24 mm 7.618 mm 8.206 mm 13.697 mm 11.267 mm 6 mm 8 mm 62.2 mm 26 mm 25.014 mm 9 mm 49.801 mm Nimble for Good, PBC gonimble.com Luggage Tag M/N: N B -B T-AT LInput: 1.0W Max Battery: 150mAh 3.7V 0.555WhFCC ID: 2AZIO- NBBTATL Made in China SN Laser SN: FEBBFF2F43425373

RF Exposure Info

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E02 TRF No.: RT-4-E-006Page 1 of 6 RF EXPOSURE REPORT Applicant : Nimble for Good, PBC. Address of Applicant : 1008 Brioso Drive Costa Mesa, CA 92627 USA Manufacturer : Nimble for Good, PBC. Address of Manufacturer : 1008 Brioso Drive Costa Mesa, CA 92627 USA Equipment under Test : Luggage Tag Model No. : NB-BT-ATL FCC ID : 2AZIO-NBBTATL Test Standard(s) : KDB447498 D01 General RF Exposure Guidance v06 Report No. : DDT-RE26060830-3E02 Issue Date : 2026/08/12 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E02 TRF No.: RT-4-E-006Page 2 of 6 Table of Contents 1.General Test Information..............................................................................................5 1.1.Description of EUT .......................................................................................................5 1.2.Accessories of EUT......................................................................................................5 1.3.Test laboratory .............................................................................................................5 2.RF Exposure evaluation for FCC .................................................................................6 2.1.Assessment procedure.................................................................................................6 2.2.Assess result ................................................................................................................6 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E02 TRF:RT-4-E-006Page 3 of 6 $!CeMetaLims!digital$ Test Report Declare Applicant : Nimble for Good, PBC. Address of Applicant : 1008 Brioso Drive Costa Mesa, CA 92627 USA Equipment under Test : Luggage Tag Model No. : NB-BT-ATL Manufacturer : Nimble for Good, PBC. Address of Manufacturer : 1008 Brioso Drive Costa Mesa, CA 92627 USA Test Standard Used: KDB447498 D01 General RF Exposure Guidance v06 We Declare: The equipment described above is tested by Guangdong Dongdian Testing Service Co., Ltd. and in the configuration tested the equipment complied with the standards specified above. The test results are contained in this test report and Guangdong Dongdian Testing Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. Report No.:DDT-RE26060830-3E02 Date of Receipt:2026/06/11Date of Test:2026/06/11~2026/08/04 Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Guangdong Dongdian Testing Service Co., Ltd. Created: Johnson HuangReviewed: Tiger MoApproved: Ella Gong 2026/08/042026/08/122026/08/12 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E02 TRF:RT-4-E-006Page 4 of 6 Revision History VersionRevision ContentIssue DateApproved V0Initial issue2026/08/12Ella Gong Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E02 TRF:RT-4-E-006Page 5 of 6 1. General Test Information 1.1. Description of EUT EUT Name:Luggage Tag Model Number:NB-BT-ATL Difference of model number:/ EUT Function Description:Please reference user manual of this device Power Supply:DC 3.7V by battery or Input: 1.0W Max Note: The above EUT information is declared by manufacturer and for more detailed features description please refer to the manufacturer's specifications or User's Manual. 1.2. Accessories of EUT AccessoriesManufacturerModel numberDescription //// 1.3. Test laboratory Guangdong Dongdian Testing Service Co., Ltd. Add.: Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808. Tel.: +86-0769-38826678, http://www.dgddt.com, Email: [email protected]. CNAS Accreditation No. L6451; A2LA Accreditation Number: 3870.01 FCC Designation Number: CN1182, Test Firm Registration Number: 540522 Innovation, Science and Economic Development Canada Site Registration Number: 10288A Conformity Assessment Body identifier: CN0048 VCCI facility registration number: C-20087, T-20088, R-20123, R-20240, G-20118 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E02 TRF:RT-4-E-006Page 6 of 6 2. RF Exposure evaluation for FCC 2.1. Assessment procedure According to 447498 D01 General RF Exposure Guidance v06 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison 2.2. Assess result Manufacturing Tolerance: ModeAntenna Frequency [MHz] Test power(dBm)Tolerance ±(dB) 24025.141 24405.431 Bluetooth LE 1M (Peak) Ant1 24805.151 24045.121 24405.391 Bluetooth LE 2M (Peak) Ant1 24785.061 Estimation Result: Worse case is as below: [2440 MHz, 6.43 dBm, (4.40 mW) output power] (4.40/5) ·[√2.440(GHz)] = 1.37< 3.0 for 1-g SAR Then SAR evaluation is not required. -----------------------End Report----------------------

Test Report

2.4GHz3216ChipAntenna:RANT3216F245C03 _ Application: WLAN,802.11b/g,Bluetooth,WLAN,etc... Features SMD,highreliability,ultraImpact,Omni-directional... PartnumberInformation RANT3216F245C03 (A)(B)(C)(D)(E)(F) ElectricalSpecification ThespecificationisdefinedonEVB. DimensionandTerminalConfiguration No.TerminalName 1Feeding/GNG 2GND/Feeding (A)ProductTypeChipAntenna (B)SizeCode 3.2x1.6mm( ± 0.2mm) (C)MaterialHighKmaterial (D)Frequency2.4~2.5GHz (E)FeedingmodePIFA&SingleFeeding (F)AntennatypeType=03 WorkingFrequencyRange2400~2500MHz Bandwidth120MHz(Min.) PeakGain2.7dBi(Typ.) Impedance50Ohm Returnloss10dB(Min) PolarizationLinear AzimuthBeamwidthOmni-directional OperationTemperature( °C )-40~85 °C ResistancetoSolderingHeats 10sec.(@280 °C ) TerminationNi/Au(Leadless) Dimension(mm) L 3.20 ± 0.20 W 1.60±0.20 T 0.45±0.20 咏成國際科技有限公司電話:13530576606 RAINInternationalTechnologyCo.,Ltd. Room 707, Building F, Tongan Zhichuangyuan, xixiang street, Baoan District,Shenzhen. 2.4GHz3216ChipAntenna:RANT3216F245C03 _ 1 EvaluationBoardReference 长条板PCB 推荐 Dimension 圆板AntennaLayoutReference Unit:mm ElectricalCharacteristics ReturnLoss&Radiation ReturnLoss Frequency(MHz) S11(dB) 2400-10.50 2450-30.62 2500-11.47 Radiation 2400MHz2450MHz2500MHz Efficiency82.52%85.26%83.01% X Y Z 2.4GHz3216ChipAntenna:RANT3216F245C03 _ TapingSpecifications ReelandTapingSpecification ReelSpecification TYPESIZEABCD 32167”5K/Reel 9.0±0.5 60±213.5±0.5178±2 TappingSpecification PackagingTypeABWEFGHTψDP PaperType3216 1.90±0.2 0 3.50±0.2 0 8.0±0.2 0 1.75±0.1 0 3.5±0.054.0±0.102.0±0.050.75±0.1 0 1.50±0.1 0 4.0±0.1 2.4GHz3216ChipAntenna:RANT3216F245C03 _ ReliabilityTable TestItemProcedure Requirements CeramicType Remark (Reference) Electrical Characterization Fulfilltheelectrical specification UserSpec. Thermal Shock 1.Preconditioning: 50±10°C/1hr,thenkeepfor24±1hrsatroomtemp. 2.Initialmeasure:Spec:referInitialspec. 3.Rapidchangeoftemperaturetest: -30°Cto+85°C;100cycles; 15minutesatLowercategorytemperature; 15minutesatUppercategorytemperature. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 107 Temperature Cycling 1.Initialmeasure:Spec:referInitialspec. 2.100Cycles(-30°Cto+85°C),SoakMode=1(2Cycle/hours). 3.Measurementat24±2Hoursaftertestcondition. NoVisibleDamage. Fulfilltheelectrical specification. JESD22 JA104 HighTemperature Exposure 1.Initialmeasure:Spec:referInitialspec. 2.Unpowered;500hours@T=+85°C. 3.Measurementat24±2hoursaftertest. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 108 LowTemperature Storage 1.Initialmeasure:Spec:referInitialspec. 2.Unpowered:500hours@T=-30°C. 3.Measurementat24±2hoursaftertest. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 108 Solderability (SMDBottomSide) Dippingmethod: a.Temperature:235±5°C b.Dippingtime:3±0.5s Thesoldershouldcover over95%ofthecritical areaofbottomside. IEC60384-21/22 4.10 SolderingHeat Resistance (RSH) Preheatingtemperature:150±10°C. Preheatingtime:1~2min. Soldertemperature:260±5°C. Dippingtime:5±0.5s NoVisibleDamage.IEC60384-21/22 4.10 Vibration5g'sfor20min.,12cycleseachof3orientations Note:Use8"X5"PCB.031"thick7securepointson,onelong sideand2securepointsatcornersofoppositesides.Parts mountedwithin2"fromanysecurepoint.Testfrom10-2000 Hz. NoVisibleDamage.MIL-STD-202 Method204 Mechanical Shock Threeshocksineachdirectionshallbeappliedalongthethree mutuallyperpendicularaxesofthetestspecimen(18shocks) Peakvalue:1,500g’s Duration:0.5ms Velocitychange:15.4ft/s Waveform:Half-sine NoVisibleDamage.MIL-STD-202 Method213 Humidity Bias 1.Humidity:85%R.H.,Temperature:85±2°C. 2.Time:500±24hours. 3.Measurementat24±2hrsaftertestcondition. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 Method106 2.4GHz3216ChipAntenna:RANT3216F245C03 _ Board Flex (SMD) 1.Mountingmethod: IR-Reflow.PCBSize(L:100×W:40×T:1.6mm) 2.Applytheloadindirectionofthearrowuntilbendingreaches 2mm. NoVisibleDamage.AEC-Q200 005 AdhesionForceof1.8Kgfor60seconds.NoVisibleDamage Magnificationof20Xor greatermaybeemployed forinspectionofthe mechanicalintegrityofthe devicebodyterminalsand body/terminaljunction. AEC-Q200 006 Physical Dimension Anyapplicablemethodusingx10magnification,micrometers, calipers,gauges,contourprojectors,orothermeasuring equipment,capableofdeterminingtheactualspecimen dimensions. Inaccordancewith specification. JESD22 JB100 RevisionHistory RevisionDateContent 12019/03/01NewDatasheet 22020/02/22Add2Dradiationcharacteristic 32020/02/22Add2Dradiationcharacteristic

Test Report

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E01 TRF: RT-4-E-005Page 1 of 88 RADIO TEST REPORT Applicant : Nimble for Good, PBC. Address of Applicant : 1008 Brioso Drive Costa Mesa, CA 92627 USA Manufacturer : Nimble for Good, PBC. Address of Manufacturer : 1008 Brioso Drive Costa Mesa, CA 92627 USA Equipment under Test : Luggage Tag Model No. : NB-BT-ATL FCC ID : 2AZIO-NBBTATL Test Standard(s) : FCC Rules and Regulations Part 15 Subpart C, ANSI C63.10-2020+Cor.1-2023 Report No. : DDT-RE26060830-3E01 Issue Date : 2026/08/12 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E01 TRF: RT-4-E-005Page 2 of 88 Table of Contents 1.Summary of Test Results .............................................................................................7 2.General Test Information..............................................................................................8 2.1.Description of EUT .......................................................................................................8 2.2.Accessories of EUT......................................................................................................9 2.3.Block diagram of EUT configuration for test.................................................................9 2.4.Decision of final test mode ...........................................................................................9 2.5.Deviations of test standard.........................................................................................10 2.6.Test environment conditions ......................................................................................10 2.7.Test laboratory ...........................................................................................................10 2.8.Measurement uncertainty...........................................................................................11 3.Equipment Used During Conductive Test ..................................................................12 4.6 dB Bandwidth ..........................................................................................................13 4.1.Block diagram of test setup ........................................................................................13 4.2.Limits ..........................................................................................................................13 4.3.Test procedure ...........................................................................................................13 4.4.Test result...................................................................................................................14 4.5.Test graphs ................................................................................................................15 5.99% Bandwidth ..........................................................................................................18 5.1.Block diagram of test setup ........................................................................................18 5.2.Limits ..........................................................................................................................18 5.3.Test procedure ...........................................................................................................18 5.4.Test result...................................................................................................................19 5.5.Test graphs ................................................................................................................20 6.Maximum Peak Output Power....................................................................................23 6.1.Block diagram of test setup ........................................................................................23 6.2.Limits ..........................................................................................................................23 6.3.Test procedure ...........................................................................................................23 6.4.Test result...................................................................................................................24 6.5.Test graphs ................................................................................................................25 7.Power Spectral Density ..............................................................................................28 7.1.Block diagram of test setup ........................................................................................28 7.2.Limits ..........................................................................................................................28 7.3.Test procedure ...........................................................................................................28 7.4.Test result...................................................................................................................29 7.5.Test graphs ................................................................................................................30 8.Band Edge Compliance (Conducted Method)............................................................33 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E01 TRF: RT-4-E-005Page 3 of 88 8.1.Block diagram of test setup ........................................................................................33 8.2.Limits ..........................................................................................................................33 8.3.Test procedure ...........................................................................................................33 8.4.Test result...................................................................................................................34 8…

Text truncated - open the document above for the full version.

Test Report

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E01 TRF:RT-4-E-005Page 57 of 88 (c) Change modulation type of device if practicable. (d) Change power supply range from 85% to 115% of the rated supply voltage (e) Rotated EUT though three orthogonal axes to determine the attitude of EUT arrangement produces highest emissions. Spectrum frequency from 9 kHz to 25 GHz (tenth harmonic of fundamental frequency) was investigated, and no any obvious emission were detected from 18 GHz to 25 GHz, so below final test was performed with frequency range from 9 kHz to 18 GHz. (4) For final emissions measurements at each frequency of interest, the EUT was rotated and the antenna height was varied between 1 m and 4 m in order to maximize the emission. Measurements in both horizontal and vertical polarities were made and the data was recorded. In order to find the maximum emission, the relative positions of equipment and all of the interface cables were changed according to ANSI C63.10 on Radiated Emission test. (5) The emissions from 9 kHz to 1 GHz were measured based on CISPR QP detector except for the frequency bands 9 - 90 kHz, 110 - 490 kHz, for emissions from 9 kHz - 90 kHz,110 kHz - 490 kHz and above 1 GHz were measured based on average detector, for emissions above 1 GHz, peak emissions also be measured and need comply with Peak limit. (6) The emissions from 9 kHz to 1 GHz, QP or average values were measured with EMI receiver with below RBW. Frequency bandRBW 9 kHz - 150 kHz200 Hz 150 kHz - 30 MHz9 kHz 30 MHz - 1 GHz120 kHz (7) For emissions above 1GHz, both Peak and Average level were measured with Spectrum Analyzer, and the RBW is set at 1 MHz, VBW is set at 3 MHz for Peak measure; According ANSI C63.10 clause 4.1.5.2.2 procedure for average measure. (8) For portable device, X axis, Y axis, Z axis are tested, and worse setup is reported. (9) According exploratory test, the emission levels are 20 dB below the limit detected from 9 kHz to 30 MHz and 18 GHz to 25 GHz, so the final test was performed with frequency range from 30 MHz to 18 GHz and recorded in below. (10) For 30 MHz ~ 25 GHz: (Scan with all mode, the worst case is reported) (11) For emissions below 1 GHz, according exploratory explorer test, when change Tx mode and channel, have no distinct influence on emissions level, so for emissions below 1 GHz, the final test was only performed with EUT working in worst mode. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E01 TRF:RT-4-E-005Page 58 of 88 12.6. Test result PASS. (See below detailed test result) 12.7. Test data TR-4-E-009 Radiated Emission Test Result Test Date:2026-07-02Tested By:Li Xiongbin Test Mode:BLE1M 2402MHz TX modePower Supply:battery Condition:Temp:21.1°C;Humi:56.8%Test Site:DDT 3# Chamber File Path:d:\ts\2026 report data\Q26060830-3E\FCC Below 1G\1 Memo:Sample Number:S26060830-012 Final Data List NO. Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable Loss [dB] Result [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 131.79831.110.783.8113.3940.0026.61QPHorizontal 241.88623.813.053.938.4840.0031.52QPHorizontal 347.95627.5613.213.9712.4440.0027.56QPHorizontal 455.91525.1712.974.039.8740.0030.13QPHorizontal 561.76924.7312.554.089.0640.0030.94QPHorizontal 698.11925.611.314.298.9043.5034.60QPHorizontal Note: 1. Result Level = Reading + Cable loss + Antenna Factor + AMP 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E01 TRF:RT-4-E-005Page 59 of 88 TR-4-E-009 Radiated Emission Test Result Test Date:2026-07-03Tested By:Li Xiongbin Test Mode:BLE1M 2402MHz TX modePower Supply:battery Condition:Temp:21.1°C;Humi:56.8%Test Site:DDT 3# Chamber File Path:d:\ts\2026 report data\Q26060830-3E\FCC Below 1G\2 Memo:Sample Number:S26060830-012 Final Data List NO. Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable Loss [dB] Result [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 134.15526.8311.303.849.6740.0030.33QPVertical 247.32132.3613.343.9617.3640.0022.64QPVertical 362.16024.5112.574.088.8640.0031.14QPVertical 472.22328.579.434.179.8740.0030.13QPVertical 590.32726.939.674.258.5543.5034.95QPVertical 6105.68926.0511.124.339.1943.5034.31QPVertical Note: 1. Result Level = Reading + Cable loss + Antenna Factor + AMP 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E01 TRF:RT-4-E-005Page 60 of 88 TR-4-E-009 Radiated Emission Test Result Test Date:2026-07-03Tested By:Li Xiongbin Test Mode:BLE2M 2404MHz TX modePower Supply:battery Condition:Temp:21.1°C;Humi:56.8%Test Site:DDT 3# Chamber File Path:d:\ts\2026 report data\Q26060830-3E\FCC Below 1G\3 Memo:Sample Number:S26060830-012 Final Data List NO. Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable Loss [dB] Result [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 131.99931.9210.903.8114.3340.0025.67QPHorizontal 247.48724.1813.303.969.1440.0030.86QPHorizontal 354.59824.4112.984.029.1140.0030.89QPHorizontal 462.59825.0312.484.099.3040.0030.70QPHorizontal 596.00925.4111.194.288.5843.5034.92QPHorizontal 6919.30224.5621.967.1621.9046.0024.10QPHorizontal Note: 1. Result Level = Reading + Cable loss + Antenna Factor + AMP 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26060830-3E01 TRF:RT-4-E-005Page 61 of 88 TR-4-E-009 Radiated Emission Test Result Test Date:2026-07-03Tested By:Li Xiongbin Test Mode:BLE2M 2404MHz TX modePower Supply:battery Condition:Temp:21.1°C;Humi:56.8%Test Site:DDT 3# Chamber File Path:d:\ts\2026 report data\Q26060830-3E\FCC Below 1G\4 Memo:Sample Number:S26060830-…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Julie Kao(V.P. of Operations)
[email protected]Fax: 06262973580

Technical Contact

NIMBLE FOR GOOD, PBCJulie Kao
[email protected]

1008 Brioso Drive · Costa Mesa, 92627 · United States

Test Firm

Guangdong Dongdian Testing Service Co., Ltd.Mr. Jamy Yu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.49 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from NIMBLE FOR GOOD, PBC.

2AZIO-NBBTATP

Passport Folio

Aug 14, 2026

Equipment Class

DTS - Digital Transmission System
2AZIO-NBBTATW

Wallet

Aug 14, 2026

Equipment Class

DTS - Digital Transmission System
2AZIO-NBBTAPT

Trace Tag

Aug 11, 2026

Equipment Class

DTS - Digital Transmission System
2AZIO-NBBTATF

Trace Key Fod

Aug 10, 2026

Equipment Class

DTS - Digital Transmission System
2AZIO-NBBTATK

Keychain

Aug 04, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter