FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN KEDING HARDWARE CO.,LTD/
  3. 2AZIX-K207

2AZIX-K207Multifunctional Outlet Socket

SHENZHEN KEDING HARDWARE CO.,LTD
Multifunctional Outlet Socket - FCC ID 2AZIX-K207 - SHENZHEN KEDING HARDWARE CO.,LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
May 25, 2021
Application Purpose
Original Equipment
Date of Application
May 25, 2021
Equipment Note
Multifunctional Outlet Socket
Frequency Range
0.11000000 - 0.20500000
Company
SHENZHEN KEDING HARDWARE CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

P ic 1 1 .Item code: K207 211 235 110 4-R5 5 T abletop Wi reless charger 2 USB charging American power overload protection switch 2. Specification: A. Configuration: 1 American power, 2 USB charging ports, overload protection switch, 1 wireless charger. See above pic. B. Rated voltage and current: AC 125V 1 2 A C. Rated power: 1 500 W D. USB charging ports power: 10W(5V /2.1A) E. Max wireless charging power: 5W 3. Installation size: (unit: mm) 4.How to install: A .Fit this product into the tabletop and fix it with screws. Ref pic 1 Pic 2 B .Press the button, the middle cover will pop up. Finally, plug your appliance to use. Ref pic 2. 5 .Notes: A .Follow the user manual to install, use and maintain this electric product B. For indoor use only. Keep away from moist, dusty, and corrosive environment likewise, which may degrade the product's safety. C. Ground connection is a must during using. D. Overloading usage is prohibited. Follow the rated voltage, frequency, current and function to connect and use it correctly. E. Cut the electricity for the appliance before connect to this product.F. Cut the power supply before you install, maintain or take apart of this product G.Do not strike this product with sharp or hard tools, which may cause damage to this product. H. Do not operate with wet hand, or pull the cable forcibly.I. Stop using once you found any abnormity of the power socket. K 207 MULTIFUNCTIONAL OUTLETS ASSEMBLY USER MANUAL (with bracket) 1.Item code: K207-01 211 235 110 4-R5 5 Tabletop Wireless charger 2 USB charging American power overload protection switch 2. Specification: A. Configuration: 1 American power, 2 USB charging ports, overload protection switch, 1 wireless charger. See above pic. B. Rated voltage and current: AC 125V 1 2 A C. Rated power: 1 500 W D. USB charging ports power: 10W(5V /2.1A) E. Max wireless charging power: 5W 3. Installation size: (unit: mm) 4.How to install: A.Discharge the screws to fit the bottom box into the tabletop, fix it with screws. Ref pic 1 Pic 2 B . Neaten cables inside the box in order to make sure they are not twisted. Fix panel with 2 screws. Finally, press and fix the power cable on the bottom box. Ref pic 2 5.Notes: A. Follow the user manual to install, use and maintain this electric product B. For indoor use only. Keep away from moist, dusty, and corrosive environment likewise, which may degrade the product's safety. C. Ground connection is a must during using. D. Overloading usage is prohibited. Follow the rated voltage, frequency, current and function to connect and use it correctly. E. Cut the electricity for the appliance before connect to this product. F. Cut the power supply before you install, maintain or take apart of this product G. Do not strike this product with sharp or hard tools, which may cause damage to this product. H. Do not operate with wet hand, or pull the cable forcibly. I. Stop using once you found any abnormity of the power socket. Pic 1 Screw Screw Tabletop K207 MULTIFUNCTIONAL OUTLETS ASSEMBLY USER MANUAL (without bracket) FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two cond itions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital d evice, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable prote ction against harmful interference in a residential installation. This equipment generates uses and c an radiate radio frequency energy and, if not installed and used in accordance with the instructions , may cause harmful interference to radio communications. However, there is no guarantee that int erference will not occur in a particular installation. If this equipment does cause harmful interferen ce to radio or television reception, which can be determined by turning the equipment off and on, t he user is encouraged to try to correct the interference by one or more of the following measures: ‐ Reorient or relocate the receiving antenna. ‐ Increase the separation between the equipment and receiver. ‐ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐Consult the dealer or an experienced radio/TV technician for help important announcement Radiation Exposure Statement The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected.

External Photos

Page: 3 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of EUT Page: 4 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Photo 3 Appearance of EUT Photo 4 Appearance of EUT Page: 5 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Photo 5 Appearance of EUT Photo 6 Appearance of EUT

ID Label/Location Info

Page: 1 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Appendix IFCC ID Label Size for the label: 80mm X 52mm Page: 2 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Appendix II ID Label Location ID LOCATION

Internal Photos

Page: 6 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Appendix IV EUT Internal Photographs Photo 7 Appearance of PCB Photo 8 Appearance of PCB Coil Antenna Page: 7 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Photo 9 Appearance of PCB Photo 10 Appearance of PCB Page: 8 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Photo 11 Appearance of PCB Photo 12 Appearance of PCB Page: 9 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Photo 13 Appearance of EUT

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TB-MPE179583 Page: 1 of 5 TB-RF-074-1.0 1A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107 Xixiang Section 467, Xixiang, Bao’an, Shenzhen, China Tel: +86 75526509301 Fax: +86 75526509195 RF Exposure Evaluation FCC ID: 2AZIX- K207 1. Client Information Applicant : SHENZHEN KEDING HARDWARE CO.,LTD Address : No.18 Tangkeng 3Rd, Pingshan District, Shenzhen, Guangdong, China Manufacturer : SHENZHEN KEDING HARDWARE CO.,LTD Address : No.18 Tangkeng 3Rd, Pingshan District, Shenzhen, Guangdong, China 2. General Description of EUT EUT Name : Multifunctional Outlet Socket Model(s) : K207, K265A Sample ID : TBBJ-20210128-04_#1 Model Difference : All PCB boards and circuit diagrams are the same, the only difference is the appearance. Product Description : Operation Frequency: 110KHz-205KHz Modulation Type: ASK Antenna: Coil Antenna Power Supply : Input: AC 125V/12A USB Output: DC 5V/2.1A Max Wireless Charge Output: 5W Software Version : N/A Hardware Version : N/A Connecting I/O Port(S) : : Please refer to the User's Manual Accessories : HONOR V30 PRO Note: More test information about the EUT please refer the RF Test Report. Report No.: TB-MPE179583 Page: 2 of 5 TB-RF-074-1.0 RF Exposure Considerations 1. Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging App v03. 2. Requirements According to the item 5.2 of KDB 680106 D01v03: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation: (1) Power transfer frequency is less than 1 MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Limits For Maximum Permissible Exposure (MPE) Report No.: TB-MPE179583 Page: 3 of 5 TB-RF-074-1.0 3. Test Setup Note: The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface. 4.Test Procedure 1) The RF exposure test was performed in anechoic chamber. 2) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface. 3) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E) were completed. 4) The EUT was measured according to the dictates of KDB 680106 D01 v03. Remark: The EUT’s test position A, B, C, D and E is valid for the E and H field measurements. 5. Test Equipment List Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Due Date Magnetic field meter NARDA ELT-400 EE030 Sep. 11, 2020 Sep. 10, 2021 6. Deviation From Test Standard No deviation 7. Mode of operation during the test / Test peripherals used Test Modes: TM1 AC/DC Adapter + EUT + Mobile Phone (Battery Status: <1%) record TM2 AC/DC Adapter + EUT + Mobile Phone (Battery Status: <50%) record TM3 AC/DC Adapter + EUT + Mobile Phone (Battery Status: <99%) record 15cm Report No.: TB-MPE179583 Page: 4 of 5 TB-RF-074-1.0 8. Test Result E-Filed Strength at 15 cm from the edges surrounding the EUT and 15 cm above the top surface Charging Battery Level Frequency Range (MHz) Measured E-Field Strength Values (V/m) E-Field Strength 50% Limits (V/m) E-Field Strength Limits (V/m) Test Position A B C D E 1% 0.118 42.601 43.355 61.451 43.732 47.125 307.0 614.0 50% 0.118 46.748 42.978 49.387 47.125 42.978 307.0 614.0 99% 0.118 61.074 49.387 42.978 34.684 41.847 307.0 614.0 Note: V/m= A/m *377 H-Filed Strength at 15 cm from the edges surrounding the EUT and 15 cm above the top surface Charging Battery Level unit Frequenc y Range (MHz) Measured H-Field Strength Values (A/m) H-Field Strength 50% Limits (A/m) H-Field Strength Limits (A/m) Test Position A B C D E 1% uT 0.118 0.1413 0.1438 0.2038 0.145 0.1563 -- -- 1% A/m 0.118 0.113 0.115 0.163 0.116 0.125 0.815 1.63 50% uT 0.118 0.155 0.1425 0.1638 0.1563 0.1425 -- -- 50% A/m 0.118 0.124 0.114 0.131 0.125 0.114 0.815 1.63 99% uT 0.118 0.2025 0.1638 0.1425 0.1150 0.1388 -- -- 99% A/m 0.118 0.162 0.131 0.114 0.092 0.111 0.815 1.63 H-Field Strength at 20cm from the top surface of the EUT Charging Battery Level Unit Frequency Range (MHz) Measured H-Field Strength Values (A/m) FCC H-Field Strength 50% Limits (A/m) FCC H-Field Strength Limits (A/m) Test Position E 1% uT 0.118 0.1338 -- -- 1% A/m 0.118 0.107 0.815 1.63 50% uT 0.118 0.1225 -- -- 50% A/m 0.118 0.098 0.815 1.63 99% uT 0.118 0.1375 -- -- 99% A/m 0.118 0.11 0.815 1.63 Note: A/m=uT/1.25 Report No.: TB-MPE179583 Page: 5 of 5 TB-RF-074-1.0 9. Test Set-up Photo Test Set-up Photo -----END OF REPORT-----

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TB-FCC179582 Page: 1 of 26 TB-RF-074-1.0 1A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107 Xixiang Section 467, Xixiang, Bao’an, Shenzhen, China Tel: +86 75526509301 Fax: +86 75526509195 FCC Radio Test Report FCC ID: 2AZIX-K207 Original Grant Report No. : TB-FCC179582 Applicant : SHENZHEN KEDING HARDWARE CO.,LTD Equipment Under Test (EUT) EUT Name : Multifunctional Outlet Socket Model No. : K207 Series Model No. : K265A Brand Name : KEDING Sample ID : TBBJ-20210128-04_#1 Receipt Date : 2021-03-31 Test Date : 2021-03-31 to 2021-05-14 Issue Date : 2021-05-17 Standards : FCC Part 15, Subpart C(15.209) Test Method : ANSI C63.10: 2013 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above, Test/Witness Engineer : Camille Li Engineer Supervisor : Ivan Su Engineer Manager : Ray Lai This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TB-FCC179582 Page: 2 of 26 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT.............................................................................. 5 1.1 Client Information ................................................................................................................. 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 6 1.4 Description of Support Units .............................................................................................. 6 1.5 Description of Test Mode .................................................................................................... 7 1.6 Description of Test Software Setting ................................................................................ 8 1.7 Measurement Uncertainty .................................................................................................. 8 1.8 Test Facility ........................................................................................................................... 8 2. TEST SUMMARY ....................................................................................................................... 9 3. TEST SOFTWARE ..................................................................................................................... 9 4. TEST EQUIPMENT .................................................................................................................. 10 5. CONDUCTED EMISSION TEST ........................................................................................... 11 5.1 Test Standard and Limit .................................................................................................... 11 5.2 Test Setup ........................................................................................................................... 11 5.3 Test Procedure ................................................................................................................... 12 5.4 Deviation From Test Standard ......................................................................................... 12 5.5 EUT Operating Mode ........................................................................................................ 12 5.6 Test Data ............................................................................................................................. 12 6. RADIATED EMISSION TEST ................................................................................................ 13 6.1 Test Standard and Limit .................................................................................................... 13 6.2 Test Setup ........................................................................................................................... 14 6.3 Test Procedure ................................................................................................................... 15 6.4 Deviation From Test Standard ......................................................................................... 15 6.5 EUT Operating Condition ................................................................................................. 15 6.6 Test Data ............................................................................................................................. 15 7. BANDWIDTH MEASUREMENT ............................................................................................ 16 7.1 Test Standard and Limit .................................................................................................... 16 7.2 Test Setup ........................................................................................................................... 16 7.3 Test Procedure ................................................................................................................... 16 7.4 Deviation From Test Standard ......................................................................................... 16 7.5 EUT Operating Condition ................................................................................................. 16 7.6 Test Data ............................................................................................................................. 16 8. ANTENNA REQUIREMENT ................................................................................................... 17 8.1 Standard Requirement ...................................................................................................... 1…

Text truncated - open the document above for the full version.

Test Setup Photos

Page: 10 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Appendix V EUT Test Photographs 15C Test Setup Photo of Setup for Radiated Emission (9KHz-30MHz) Photo of Setup for Radiated Emission (Below 1 GHz) Page: 11 of 11 FCC ID:2AZIX-K207 TB-RF-074-3.0 Photo of Setup for Conducted Emission -----END OF REPORT-----

Contact Information

Applicant

Anjing Zhu
[email protected]+86 18617100904Fax: 0755-26509195

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]---

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term