Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
使用说明书 安装方法 接口使用说明 *支持键盘、鼠标、手机、 硬盘等设备 *辅助供电端口: 辅助供电端口需要外接充电器(充电器非标配)供电的情况: 1.使用大硬盘进行数据传输 2.给手机等设备充电 *使用赠送的USB数据线连接电脑主机提供数据传输 Pcdocking PRO 智能扩展坞 硬盘数据传输手机充电 DC电源接口 24V2A TYPE-C辅助 供电接口5V3A TYPE-C接口 灯带开关 USB 3.0接口 指纹接口 5V1A 灯带接口 5V1A TYPE-C对A接口 供电5V3A 标配安全认证电源配适器 *指纹识别与wifi功能需要安装驱动方可正常运行 驱动安装链接:www.lanq.com TYPE-C 3.2TYPE-C 3.2USB 3.0USB 3.0ON/OFF 公司名称 : 狼群云创(深圳)电子有限公司 地址 : 深圳市龙岗区坂田街道南坑社区坂田手造文化街B区B316-321室之320室 网址 : www.lanq.com 生产商 : 深圳市富邦新科技有限公司 地址 : 深圳市光明区马田街道合水口社区第四工业区安立邦科技园6号电梯3楼 Made in China 通电使用前请先接上 PCDocking的电源接口 Guidebook To Set Up Interface Specification *Support keyboard, mouse, mobile phone, hard disk and other devices to connect with *Auxiliary power supply port: The following circumstances that would lead to the auxiliary power supply port require an external charger (not standard charger) to charge: 1. Use a large hard drive for data transfer 2. Charge mobile phones and other devices *Use the complimentary USB data cable to connect and transfer data PCDOCKING PRO Use a large hard drive for data transfer Charge mobile phones and other devices DC power interface 24V2A Power supply interface 5V3A TYPE-C interface Light strip switch USB 3.0 interface Fingerprint scanner supply interface 5V1A Light strip interface 5V1A TYPE-C to A interface5V3A Standard safety certified power adapter *You need to install the driver first to use Fingerprint scanner and Wi-Fi function.Driver installation URL:www.lanq.com TYPE-C 3.2TYPE-C 3.2USB 3.0USB 3.0ON/OFF Company Name : Langqun Yunchuang (Shenzhen) Electronics Co., Ltd. Address: Room 320, B316-321,Building B, Bantian Handmade Culture Street, Nankeng Community, Bantian Street, Longgang District, Shenzhen.CN Website : www.lanq.com Manufacturer: Shenzhen Fubon New Technology Co., Ltd. Address: 3rd Floor, Elevator 6, Anlibang Technology Park, Fourth Industrial Zone, Heshuikou Community, Matian Street, Guangming District, Shenzhen Made in China Please plug power supply of PCDocking in before using Guía Como establecerlo Especificación de la interfaz *Soporta teclado, ratón, teléfono móvil, disco duro y otros dispositivos para conectar con * Puerto de suministro de energía auxiliar: Las siguientes circunstancias que darían lugar al puerto de suministro de energía auxiliar requieren un cargador externo (no un cargador estándar) para cargar: 1. Usar un disco duro grande para la transferencia de datos 2. Cargar los teléfonos móviles y otros dispositivos *Use el cable de datos USB de cortesía para conectar y transferir datos PCDOCKING PRO Usar un disco duro grande para la transferencia de datos Cargar los teléfonos móviles y otros dispositivos Interfaz de alimentación DC 24V2A Interfaz de la fuente de alimentación 5V3A Interfaz TIPO-C Interruptor de la tira de luz Interfaz USB 3.0 Interfaz de suministro del escánerde huellas dactilares 5V1A Interfaz de la tira de luz 5V1A Interfaz de TIPO C a A 5V3A Adaptador de corriente con certificado de seguridad estándar *Necesitas instalar el controlador primero para usar el escáner de huellas dactilares y la función Wi-Fi.URL de instalación del controlador:www.lanq.com TYPE-C 3.2TYPE-C 3.2USB 3.0USB 3.0ON/OFF Nombre de empresa: Langqun Yunchuang (Shenzhen) Electronics Co., Ltd. Dirección: Habitación 320, Habitación B316-321, Bloque B, Calle de la Cultura Artesanal Bantian, Comunidad Nankeng, Calle Bantian, Distrito Longgang, Shenzhen Sitio web: www.lanq.com Fabricante: Shenzhen Fubon New Technology Co., Ltd. Dirección: 3º piso, ascensor 6, Parque Tecnológico Anlibang, Cuarta Zona Industrial, Comunidad de Heshuikou, Calle Matian, Distrito de Guangming, Shenzhen Made in China Por favor, conecte antes de encender.Interfaz de alimentación para PCDocking Manuel de référence Pour mettre en place Spécification de l'interface *Prise en charge du clavier, de la souris, du téléphone portable, du disque dur et d'autres appareils permettant de se connecter à * Port d'alimentation électrique auxiliaire : Les circonstances suivantes qui mèneraient au port d'alimentation auxiliaire nécessitent un chargeur externe (pas un chargeur standard) pour la charge : 1. Utilisez un grand disque dur pour le transfert de données 2. Chargez les téléphones mobiles et autres appareils *Utilisez le câble de données USB gratuit pour connecter et transférer des données PCDOCKING PRO Utilisez un grand disque dur pour le transfert de données Chargez les téléphones mobiles et autres appareils Interface d'alimentation en courant continu 24V2A Interface d'alimentation électrique 5V3A Interface TYPE-C Interrupteur à bande lumineuse Interface USB 3.0 Interface d'alimentation du scanner d'empreintes digitales 5V1A Interface de la bande lumineuse 5V1A Interface TYPE-C vers A 5V3A Adaptateur électrique standard certifié pour la sécurité *Vous devez d'abord installer le pilote pour utiliser le scanner d'empreintes digitales et la fonction Wi-Fi.URL d'installation du pilote:www.lanq.com TYPE-C 3.2TYPE-C 3.2USB 3.0USB 3.0ON/OFF Nom de la société : Langqun Yunchuang (Shenzhen) Electronics Co., Ltd. Adresse : Salle 320, salle B316-321, bloc B, Rue de la culture artisanale de Bantian, Communauté de Nankeng, Rue Bantian, District de Longgang, Shenzhen Site web : www.lanq.com Fabricant : Shenzhen Fubon New Technology Co., Ltd. Adresse : 3e étage, ascenseur 6, parc technologique d'Anlibang, quatrième zone industrielle, communauté de Heshuikou, Rue Matian, district de Guangming, Shenzhen Made in China Connectez le connecteur d'alimentation pcdocking avant de l'utiliser. Benutzerhandbuch So richten Sie es ein Spezifikation der Schnittstelle *Unterstützt Tastatur, Maus, Mobiltelefon, Festplatte und andere Geräte zur Verbindung mit * Anschluss für Hilfsstromversorgung: Die folgenden Umstände, die dazu führen würden, dass der Anschluss für die Hilfsstromversorgung ein externes Ladegerät (kein Standard-Ladegerät) zum Laden benötigt: 1. Verwenden Sie eine große Festplatte für die Datenübertragung 2. Laden von Mobiltelefonen und anderen Geräten *Verwenden Sie das mitgelie…
Text truncated - open the document above for the full version.
Langqun Yunchuang (Shenzhen) Electronics Co., Ltd. Agent Authorization Company: Langqun Yunchuang (Shenzhen) Electronics Co., Ltd. Address: Room 320, B316-321, Bantian Hand-made Culture Street B, Nankeng Community, Bantian Street, Longgang District, Shenzhen, China Product Name: Docking Station Model Number(s): PCDock PRO, PCDock PRO max Product Description: Docking Station We authorize MiCOM Labs Inc.,575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2021/04/15 Name: Sunny Liu Title: Engineer Company: Langqun Yunchuang (Shenzhen) Electronics Co., Ltd.
LangqunYunchuang (Shenzhen) Electronics Co., Ltd. Family models declaration letter. 5/8/2021 We LangqunYunchuang (Shenzhen) Electronics Co., Ltd. Of Room 320, B316-321, Bantian Hand-made Culture Street B, Nankeng Community, Bantian Street, Longgang District, Shenzhen, China Product: Docking Station FCC ID: 2AZKX-PCDOCKPRO Model Name: PCDock PRO Serial Model: PCDock PRO max All the model are the same circuit and RF module. except the model Name. Signature Signature Name : Sunny Liu Title: Manager Company name: Langqun Yunchuang (Shenzhen) Electronics Co., Ltd.
Langqun Yunchuang (Shenzhen) Electronics Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2021/04/15 Subject; Request for Confidentiality FCC ID: 2AZKX-PCDOCKPRO To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description FCC_Software_Security_Requirements_for_UNII_devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Sunny Liu Title: Engineer Email: [email protected]
LangqunYunchuang (Shenzhen) Electronics Co., Ltd. Room 320, B316-321, Bantian Hand-made Culture Street B, Nankeng Community, Bantian Street, Longgang District, Shenzhen China Date: Apr 28, 2020 FCC ID: 2AZKX-PCDOCKPRO Model Number: PCDock PRO, PCDock PRO max To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Telecell Mobile (H.K) Limited, declare that this EUT (FCC ID: 2AZKX-PCDOCKPRO) will conduct FCC compliance testing, the SDOC part recognized test lab(Shenzhen NTEK Testing Technology Co., Ltd.( ShenZhen Lab.). 1/F, Building E, Fenda Science Park, Sanwei Community,Xixiang Street Bao’an District, Shenzhen 518126 P.R. China) Please contact me if you have any question. Sincerely, (Signed) Name / Title: Sunny Liu/ Engineer Company: Langqun Yunchuang (Shenzhen) Electronics Co., Ltd. Address: Room 320, B316-321, Bantian Hand-made Culture Street B, Nankeng Community, Bantian Street, Longgang District, Shenzhen, China Phone: 18124025986 Email: [email protected]
S21012802504 Model: PCDock PRO Photo 1 Photo 2 S21012802504 Model: PCDock PRO Photo 3 Photo 4 S21012802504 Model: PCDock PRO Photo 5 Photo 6 S21012802504 Model: PCDock PRO Photo 7 Photo 8 S21012802504 Model: PCDock PRO Photo 9 Photo 10 S21012802504 Model: PCDock PRO Photo 11 Photo 12
S21012802504 Model: PCDock PRO Photo 1 Photo 2 S21012802504 Model: PCDock PRO Photo 3 Photo 4 WIFI ANT1 BT ANT WIFI ANT2 S21012802504 Model: PCDock PRO Photo 5 Photo 6 S21012802504 Model: PCDock PRO Photo 7 Photo 8 S21012802504 Model: PCDock PRO Photo 9 Photo 10 S21012802504 Model: PCDock PRO Photo 11 Photo 12 S21012802504 Model: PCDock PRO Photo 13 Photo 14 S21012802504 Model: PCDock PRO Photo 15 Photo 16 S21012802504 Model: PCDock PRO Photo 17 Photo 18
FCC ID: 2AZKX-PCDOCKPRO 1.Measuring Standard FCC Part 1(1.1310) and Part 2(2.1091), KDB 680106 D01v03 RF Exposure Wireless Charging App v03 1.2. Requiments Three different categories of transmitters are defined by the FCC in OET Bulletin 65. These categories are fixed installation, mobile, and portable and are defined as follows: o Fixed Installations: fixed location means that the device, including its antenna, is physically secured at a permanent location and is not able to be easily moved to another location. Additionally, distance to humans from the antenna is maintained to at least 2 meters. o Mobile Devices: a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to be generally used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structures and the body of the user or nearby persons. Transmitters designed to be used by consumers or workers that can be easily re-located, such as a wireless modem operating in a laptop computer, are considered mobile devices if they meet the 20 centimeter separation requirement. The FCC rules for evaluating mobile devices for RF compliance are found in 47 CFR §2.1091. o Portable Devices: a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable device requirements are found in Section 2.1093 of the FCC's Rules (47 CFR§2.1093). The FCC also categorizes the use of the device as based upon the user’s awareness and ability to exercise control over his or her exposure. The two categories defined are Occupational/ Controlled Exposure and General Population/Uncontrolled Exposure. These two categories are defined as follows: Occupational/Controlled Exposure: In general, occupational/controlled exposure limits are applicable to situations in which persons are exposed as a consequence of their employment, who have been made fully aware of the potential for exposure and can exercise control over their exposure. This exposure category is also applicable when the exposure is of a transient nature due to incidental passage through a location where the exposure levels may be higher than the general population/uncontrolled limits, but the exposed person is fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. Awareness of the potential for RF exposure in a workplace or similar environment can be provided through specific training as part of a RF safety program. If appropriate, warning signs and labels can also be used to establish such awareness by providing prominent information on the risk of potential exposure and instructions on methods to minimize such exposure risks. General Population/Uncontrolled Exposure: The general population / uncontrolled exposure limits are applicable to situations in which the general public may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Members of the general public would come under this category when exposure is not employment-related; for example, in the case of a wireless transmitter that exposes persons in its vicinity. Warning labels placed on low-power consumer devices such as cellular telephones are not considered sufficient to allow the device to be considered under the occupational/controlled category, and the general population/uncontrolled exposure limits apply to these devices. 1.3 Test configuration 1, The field strength of both E-field and H-field was measured at 15cm using the equipment list above for determining compliance with the MPE requirements of FCC Part 1.1310. 2, The RF power density was measured at Under maximum load test 3, Maximum E-field and H-field measurements were made 15cm from each side of the EUT. Along the side of the EUT and still 15cm away from the edge of the EUT, the field probes were positioned at the location where there is maximum field strength. The maximum E-field and H-field is reported below. 4, This device uses a wireless charging circuit for power transfer operating at the frequency of 111–175kHz. Thus, the 300kHz limits were used: E-field Limit = 614 (V/m); H-field limit = 1.63 (A/m). 1.4 Test Setup 2. Limits 3. MEASURING DEVICE AND TEST EQUIPMENT 2.1For MPE Measurement Equipment Manuf acturer Model No. Serial No. Last calibration Calibrated until Cal. Interval E-Field Probe(100kHz-3GHz) Narda EF0391 Q15221 May 15, 2020 May 14, 2021 1 Year H-Field Probe(300KHz-30MHz) Narda HF3061 Q15835 May 15, 2020 May 14, 2021 1 Year Broadband Field Meter Narda NBM-550 Q201455 May 15, 2020 May 14, 2021 1 Year Load N/A N/A N/A N/A N/A N/A 4. Measuring Results All the modulation modes(Max Load/Half Load/No Load) have been tested, and the worst result was report as below: EUT: Docking Station Model Name. : PCDock PRO Temperature: 26 °C Relative Humidity: 54% Pressure: 1010hPa Test Date: 2021-04-03 Test Voltage: DC 24V from adapter AC 120V/60Hz Test Mode : Max Load Low frequency: Table 1. H-Field MPE Data-Top EUT Side Top(A/m) Limits (A/m) Max load 0.062 1.63 Table 2. H-Field MPE Data- Surrounding EUT Side Left(A/m) Right(A/m) Bottom (A/m) Z- Axis(above) (A/m) Limits (A/m) Max load 0.063 0.061 0.043 0.062 1.63 Table 3. E-Field MPE E-Field Measurement (15cm) EUT Side Left(V/m) Right(V/m) Top(V/m) Bottom (V/m) Z- Axis(above) (V/m) Limits (V/m) Max load 2.18 1.96 1.54 1.64 1.26 614 Middle frequency: Table 1. H-Field MPE Data-Top EUT Side Top(A/m) Limits (A/m) Max load 0.033 1.63 Table 2. H-Field MPE Data- Surrounding EUT Side Left(A/m) Right(A/m) Bottom (A/m) Z- Axis(above) (A/m) Limits (A/m) Max load 0.0041 0.048 0.035 0.069 1.63 Table 3. E-Field MPE E-Field Measurement (15cm) EUT Side Left(V/m) Right(V/m) Top(V/m) Bo…
Text truncated - open the document above for the full version.
Report No.: S21012802504005 Version.1.1 Page 1 of 26 FCC Test Report FCC ID: 2AZKX-PCDOCKPRO Product: Docking Station Trade Name: PC DOCK Model Number: PCDock PRO Family Model: PCDock PRO max Report No.: S21012802504005 Prepared for LangqunYunchuang (Shenzhen) Electronics Co., Ltd. Room 320, B316-321, Bantian Hand-made Culture Street B, Nankeng Community, Bantian Street, Longgang District, Shenzhen China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen P.R. China Tel:400-800-6106,0755-2320 0050 / 2320 0090 Website:http://www.ntek.org.cn Report No.: S21012802504005 Version.1.1 Page 2 of 26 TEST RESULT CERTIFICATION Applicant’s name ................. : LangqunYunchuang (Shenzhen) Electronics Co., Ltd. Address ................................. : Room 320, B316-321, Bantian Hand-made Culture Street B, Nankeng Community, Bantian Street, Longgang District, Shenzhen China Manufacturer's Name .......... : LangqunYunchuang (Shenzhen) Electronics Co., Ltd. Address ................................. : Room 320, B316-321, Bantian Hand-made Culture Street B, Nankeng Community, Bantian Street, Longgang District, Shenzhen China Product description Product name............................ : Docking Station Model and/or type reference : PCDock PRO, PCDock PRO max Standards ............................. : FCC part 15C ANSI C63.10:2013 KDB 680106 D01 RF Exposure Wireless Charging App v03 This device described above has been tested by Shenzhen NTEK Testing Technology Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK Testing Technology Co., Ltd., this document may be altered or revised by Shenzhen NTEK Testing Technology Co., Ltd., personnel only, and shall be noted in the revision of the document. The test results of this report relate only to the tested sample identified in this report. Date of Test ........................................... : Date (s) of performance of tests ............. : 28 Jan. 2021 ~ 19 Mar. 2021 Date of Issue .......................................... : 19 Mar. 2021 Test Result.............................................. : Pass Testing Engineer : (Mary Hu) Technical Manager : (Jason Chen) Authorized Signatory : (Alex Li) Report No.: S21012802504005 Version.1.1 Page 3 of 26 Table of Contents Page 1 . TEST SUMMARY 4 1.1 FACILITIES AND ACCREDITATIONS 5 1.2 LABORATORY ACCREDITATIONS AND LISTINGS 5 1.3 MEASUREMENT UNCERTAINTY 5 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST SETUP 9 2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL 10 2.4 MEASUREMENT INSTRUMENTS LIST 11 3 . EMC EMISSION TEST 12 3.1 CONDUCTED EMISSION MEASUREMENT 12 3.1.1 POWER LINE CONDUCTED EMISSION 12 3.1.2 TEST PROCEDURE 13 3.1.3 TEST SETUP 13 3.1.4 EUT OPERATING CONDITIONS 13 3.1.5 TEST RESULTS 14 3.2 RADIATED EMISSION MEASUREMENT 16 3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 16 3.2.2 TEST PROCEDURE 17 3.2.3 TEST SETUP 18 3.2.4 TEST RESULTS 19 4. BANDWIDTH TEST 24 4.1 TEST PROCEDURE 24 4.2 TEST SETUP 24 4.3 TEST RESULT 25 5. ANTENNA APPLICATION 26 5.1 Antenna Requirement 26 5.2 Result 26 Report No.: S21012802504005 Version.1.1 Page 4 of 26 1. TEST SUMMARY Test procedures according to the technical standards: EMC Emission Standard Test Item FCC Rules Limit Judgment Remark FCC part 15C:2018 ANSI C63.10:2013 Conducted Emission §15.207 Class B PASS Radiated Emission §15.209 Class B PASS ANTENNA APPLICATION §15.203 / PASS NOTE: (1) ’N/A’ denotes test is not applicable in this Test Report (2) For client’s request and manual description, the test will not be executed. Report No.: S21012802504005 Version.1.1 Page 5 of 26 1.1 FACILITIES AND ACCREDITATIONS All measurement facilities used to collect the measurement data are located at 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen 518126 P.R. China. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 and CISPR Publication 22. 1.2 LABORATORY ACCREDITATIONS AND LISTINGS Site Description CNAS-Lab. : The Laboratory has been assessed and proved to be in compliance with CNAS-CL01:2006 (identical to ISO/IEC 17025:2005) The Certificate Registration Number is L5516. IC-Registration : The Certificate Registration Number is 9270A-1. FCC- Accredited : Test Firm Registration Number: 463705. Designation Number: CN1184 A2LA-Lab. : The Certificate Registration Number is 4298.01 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Name of Firm : Shenzhen NTEK Testing Technology Co., Ltd. Site Location : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen 518126 P.R. China. 1.3 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE NTEKC01 ANSI 150 KHz ~ 30MHz 3.2 B. Radiated Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE NTEKA01 ANSI 30MHz ~ 1000MHz 4.7 1GHz ~12.4GHz 5.0 Report No.: S21012802504005 Version.1.1 Page 6 of 26 Revision History Report No. Version Description Issued Date S21012802504005 Rev.01 Initial issue of report 19 Mar. 2021 Report No.: S21012802504005 Version.1.1 Page 7 o…
Text truncated - open the document above for the full version.
Radiated Measurement Photos AC Conducted Measurement Photos
PHOTOGRAPHS OF TEST SETUP 15 cm surrounding 20 cm above the top
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1257 MHz - 0.1259 MHz | - |

Docking Station
Equipment Class
DTS - Digital Transmission System