intelliZENS SMART PLUG ADAPTOR USER MANUAL DEVICE PICTURE iz PA xxxx 1.I ntroduction: Employment of IntelliZENS Smart Plug Adapter offers you device protection from surges and voltage fluctuations, allows you to measure power consumption patterns, monitor the appliances basic health via smart alerts and controlling options such as setting specific voltage and power consumption limits to your appliances. Following are the key features of the device you have purchased. 1.1 Protection: IntelliZENS smart plug adapter offers a range of appliance protection features that are not supported by typical smart plugs out there in the market. This is why we call the device and solution rather than a smart plug! •Surge Protection up to 5000V (5kV) •Over & Under Voltage Protection by disconnecting the device from the supply when voltage fluctuates beyond normal range and reconnecting the device once voltage is stable. •Over & Under Operating Power Fluctuation Protection by allowing you to set specific power consumption range based on your appliance’s manufacturer recommendations. Once you set these limits, device will monitor power consumption of the appliance, detach the appliance from the supply and report to you via smart alerts if the device is connected to internet. •Zero Cross Voltage Switching to ensure appliance always turns ON at the most safer load conditions. This is the same feature employed by some of your expensive and power fluctuation sensitive appliances. Adding this to the plug point itself can prevent situations such as having to replace appliance’s PCB boards, which can be expensive. •Plug Point Fire Hazard Protection via shutting down the plug point if the internal temperature of the plug socket exceeds certain limits. This feature helps conditions such as burnt plug sockets etc and acts as a fire hazard deterrent. In such conditions, this device will turn-off the appliance (no-load condition) and alerts the users via smart messages provided device is connected to the internet. •Electrical Earth Fault Detector will generate smart alerts if your plug point’s earth wiring is not optimally functional. 1 .2 Measure & Monitor IntelliZENS smart plug adapter comes with power consumption measurement circuit as well as integrated temperature and humidity monitoring sensors. This opens up a range of possibilities such as: •Predicting Maintenance Needs in conditions such as air-conditioner not cooling the room efficiently to geyser turning ON more frequently. These factors unnecessarily cause excessive power consumption costing you more and attribute to increasing CO2 emissions which are high in power generation. •Periodic Power Consumption Reports allowing you to predict potential electrical supply costs from the specific appliance as well as alerting you if the device is consuming excessive energy. This will allow you to take necessary actions to prevent such situations 1 .3 Control •Offers you both OFFLINE & ONLINE control facilities via supporting both WiFi (internet based) and Bluetooth (direct from the mobile). This will help you not only in controlling devices when there is no internet, but also semi-control appliances that are typically not in the range of WiFi •Allows you to set multiple schedules for the appliance in the same day as well as supports count down timer functionality. Multiple schedules while offer you more flexibility in scheduling your appliances per your daily utilization patterns, count down times type additional scheduling facility can really help scheduling repetitive task such as water my plants for XX minutes every YY hours. Such features are very helpful when you have repetitive task requiring set-us such as balcony / roof gardens using drip irrigation etc. •Ofcourse your plug also supports typical Voice Activated Controls such as controlling via Amazon Alex, Google Home etc as with any other smart plugs out there in the market. Now you now know what all can you do with iZ xxxx you have purchased! Hope this device helps you offering you possible intelligence about your appliance and also insights on your usage patterns. Please do provide us your feedback if you think, this device can be further improved in terms of features. Where possible, we will try to improve your experience on a continual basis via software upgrades to the device. 2.S etting Up & Registering Your D evice 2 .1 Where i s What on the Device Device Photos with notes. 2 .2 S etting U p your Device 2.3 Download Evoluzn Smart H ome A pp Download from Google Play Download from IOS App Store 2.4 Create Your U ser Account Click the SignUp Button Enter your desired credintials and click Submit button You will receive an OTP via SMS & Email with in 1 to 2 minutes Enter the OTP and click verify your OTP button Once account is verifired you will be redirected to Login screen 2.5 Log into Your Account Enter your Login details You will be Going to your home screen 2.6 Add Device Click on Add Device Button to add your appliance if you are setting up your device for the first time. You will be directed to the following screen NOTE : If you have only one device that device’s identifier will show in the screen, if you have multiple devices at home app will show the full list of identifiers 2.6.1 Select the Bluetooth ID of Your Device & Connect Select the desire device identifier and click the Connect Button 2.6.2 Verify Your Device Connection You can now verify whether your mobile is connected to the device by trying to Turn it OFF / ON. If the device could be turned OFF and turned ON, you have successfully setup your device. Now it is the time to connect your device to internet via WiFi by clicking the Proceed to WiFi Connection button 2.6.3 Select Your Home WiFi Network & Connect the Device The app will show all the wifi network SSID’s in the range Select your desired home Wifi SSID and enter your wifi networks password in the Space shown as Please enter your Wifi password and click the Connect Device to Wi…
Text truncated - open the document above for the full version.
evoluzn DATE 2021-04-25 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agernt On our behalf,I appointJasonWNu of Global United Technology Services Co., Ltd.and No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents accurately describe the device or system for which equipment certification is sought. l also certify that each unit manufactured, imported, or marketed, as defined in the Federal Communications Commission's regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Evoluzn Inc, 34 Samoset Lane, Schaumburg, Ilinois 60193, United States. Signature: Name: Suryanarayana Jonnalagadda Title: CEO Company: Evoluzn Inc Evoluzn Inc. Confidential & Proprietary
Date : 2021-04-25 Equipment Autorisation Division Federal Communications Commission 7 435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AZN3-PA16UW evoluzn Product Name: lntelliZENS SMART PLUG Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission's rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality - for example ... ) •S chematics •Block diagram •Operation description •BOM These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Signature: N � onnalagadda Title: CEO Company: Evoluzn Inc Evoluzn Inc. Confidential & Proprietary
FCC LABLE AND LOCATION: Lable dimensions with Fcc id : Location of Lable on device: 2AZN3-PA16UW IZ-PA16UW
.
FCC ID: 2AZN3-PA16UW RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. FCC ID: 2AZN3-PA16UW Test Result of RF Exposure Evaluation Wifi Channel Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result Lowest (2412MHz) 58.34 0.02484 1.0 PASS Middle (2437MHz) 56.49 0.02405 1.0 PASS Highest (2462MHz) 57.28 0.02439 1.0 PASS Remark: antenna gain=3.3dBi
Global United Technology Services Co., Ltd. Report No.: GTSL202104000079F02 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 49 TEST REPORT Applicant: Evoluzn Inc Address of Applicant: 34 Samoset Lane, Schaumburg, Illinois 60193, United States Manufacturer: EVOLUZN INDIA PRIVATE LIMITED Address of Manufacturer: 51-8-40/21/3, KRM COLONY, NEAR BHARAT APARTMENT, SEETHAMMADARA, VISAKHAPATNAM, ANDHRA PRADESH, INDIA Equipment Under Test (EUT) Product Name: intelliZENS Smart Plug Adaptor 16 Model No.: intelliZENS SPA16UW Trade Mark: N/A FCC ID: 2AZN3-PA16UW Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: April 08, 2021 Date of Test: April 08-14, 2021 Date of report issued: April 28, 2021 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTSL202104000079F02 Global United Technology Services Co., Ltd. No. 123-128, Tower A,Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 49 2 Version Version No. Date Description 00 April 28, 2021 Original Prepared By: Date: April 28, 2021 Project Engineer Check By: Date: April 28, 2021 Reviewer Report No.: GTSL202104000079F02 Global United Technology Services Co., Ltd. No. 123-128, Tower A,Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 49 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION ...................................................................................................................................................2 3 CONTENTS ...............................................................................................................................................3 4 TEST SUMMARY ......................................................................................................................................4 5 GENERAL INFORMATION .......................................................................................................................5 5.1 GENERAL DESCRIPTION OF EUT ..........................................................................................................5 5.2 TEST MODE .........................................................................................................................................7 5.3 DESCRIPTION OF SUPPORT UNITS ........................................................................................................7 5.4 DEVIATION FROM STANDARDS ..............................................................................................................7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................7 5.6 TEST FACILITY ....................................................................................................................................7 5.7 TEST LOCATION ..................................................................................................................................7 5.8 ADDITIONAL INSTRUCTIONS ..................................................................................................................7 6 TEST INSTRUMENTS LIST ......................................................................................................................8 7 TEST RESULTS AND MEASUREMENT DATA .....................................................................................10 7.1 ANTENNA REQUIREMENT ....................................................................................................................10 7.2 CONDUCTED EMISSIONS ....................................................................................................................11 7.3 CONDUCTED PEAK OUTPUT POWER ...................................................................................................14 7.4 CHANNEL BANDWIDTH .......................................................................................................................15 7.5 POWER SPECTRAL DENSITY ..............................................................................................................18 7.6 BAND EDGES .....................................................................................................................................21 7.6.1 Conducted Emission Method ......................................................................................................21 7.6.2 Radiated Emission Method .........................................................................................................24 7.7 SPURIOUS EMISSION .........................................................................................................................29 7.7.1 Conducted Emission Method ......................................................................................................29 7.7.2 Radiated Emission Method .........................................................................................................32 8 TEST SETUP PHOTO .............................................................................................................................49 9 EUT CONSTRUCTIONAL DETAILS .......................................................................................................49 Report No.: GTSL202104000079F02 Global United Technology Services Co., Ltd. No…
Text truncated - open the document above for the full version.
Radiated Emission Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.42 GHz - 2.45 GHz | 36.14 mW |