FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Xiamen Yinxu Industry & Trade Co., Ltd./
  3. 2AZNW-WSLB

2AZNW-WSLBSmart bulb

Xiamen Yinxu Industry & Trade Co., Ltd.
Smart bulb - FCC ID 2AZNW-WSLB - Xiamen Yinxu Industry & Trade Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 13, 2021
Application Purpose
Original Equipment
Date of Application
May 13, 2021
Equipment Note
Smart bulb
Frequency Range
2412.00000000 - 2462.00000000
Company
Xiamen Yinxu Industry & Trade Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Xiamen Yinxu Industry & Trade Co., Ltd. Add: No.33 Factory Building, No.10-2 Lot Tong'an ParkTong'an Industrial Zone Xiamen China Date: 2021-5-11 FCC ID: 2AZNW-WSLB Dear Sir/Madam, We, Xiamen Yinxu Industry & Trade Co., Ltd. Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Smart bulb Model no.: SBR30, SG45-E12, SG45-E26, SC37, SGU10, SA60 Sincerely, Name/Title: Male Lin/General Manager Company: Xiamen Yinxu Industry & Trade Co., Ltd. Address: No.33 Factory Building, No.10-2 Lot Tong'an ParkTong'an Industrial Zone Xiamen China Phone: +86-592-7196111 Fax: +86-592-7196111 E-Mail: [email protected]

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2021-5-11> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AZNW-WSLB SBR30 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Male Lin/General Manager Company: Xiamen Yinxu Industry & Trade Co., Ltd. Address: No.33 Factory Building, No.10-2 Lot Tong'an ParkTong'an Industrial Zone Xiamen China Phone: +86-592-7196111 Fax: +86-592-7196111 E-Mail: [email protected]

Cover Letter(s)

Xiamen Yinxu Industry & Trade Co., Ltd. No.33 Factory Building, No.10-2 Lot Tong'an ParkTong'an Industrial Zone Xiamen China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2021-5-11 To whom it may concern: We, Xiamen Yinxu Industry & Trade Co., Ltd. the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AZNW-WSLB including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Male Lin/General Manager Company: Xiamen Yinxu Industry & Trade Co., Ltd. Address: No.33 Factory Building, No.10-2 Lot Tong'an ParkTong'an Industrial Zone Xiamen China Phone: +86-592-7196111 Fax: +86-592-7196111 E-Mail: [email protected]

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB EXTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Fig.3 Fig.3

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L: 3cm*W: 2cm Label Location Smart bulb Model No.: SBR30 FCC ID: 2AZNW-WSLB Caution:This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB INTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Fig.2 Fig.2 ANT SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Fig.2 Fig.2

RF Exposure Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 4 FCC RF Exposure Evaluation 1. Product Information FCC ID 2AZNW-WSLB Product name Smart bulb Test Model SBR30 Power supply AC 110-130V, 12W Modulation Type IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM,QPSK,BPSK) Antenna Type Internal Antenna Antenna Gain 0dBi(Max.) Hardware version / Software version / FCC Operation frequency 2412 – 2462 MHz Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Devices 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 4 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information Artemis Antenna can only use antennas certificated as follows provided by manufacturer; Internal Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Note Antenna Internal Antenna 2400MHz-2500MHz 0dBi WIFI Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 4 6. Conducted Power Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) 11B 1 2412 15.81 6 2437 16.31 11 2462 15.55 11G 1 2412 14.36 6 2437 16.54 11 2462 15.81 11N20SISO 1 2412 14.09 6 2437 16.43 11 2462 15.81 11N40SISO 3 2422 16.41 6 2437 16.53 9 2452 16.21 7. Manufacturing Tolerance 11B (Peak) Channel Channel 1 Channel 6 Channel 11 Target (dBm) 15.0 16.0 15.0 Tolerance ±(dB) 1.0 1.0 1.0 11G (Peak) Channel Channel 1 Channel 6 Channel 11 Target (dBm) 14.0 16.0 15.0 Tolerance ±(dB) 1.0 1.0 1.0 11N20SISO (Peak) Channel Channel 1 Channel 6 Channel 11 Target (dBm) 14.0 16.0 15.0 Tolerance ±(dB) 1.0 1.0 1.0 11N40SISO (Peak) Channel Channel 3 Channel 6 Channel 9 Target (dBm) 16.0 16.0 16.0 Tolerance ±(dB) 1.0 1.0 1.0 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 4 8. Measurement Results 8.1 Standalone MPE As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna refer to antenna information, the RF power density can be obtained. [Antenna ] Band/Mode RF output p…

Text truncated - open the document above for the full version.

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 1 of 46 Appendix A RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: Smart bulb Test Model: SBR30 Environmental Conditions Temperature: 24.6 C Relative Humidity: 54.1% ATM Pressure: 100.0 kPa Test Engineer: Jay Li Supervised by: Li Huan A.1 Duty Cycle Test Mode Test Channel Ant Duty Cycle[%] Verdict 11B 2437 Ant1 100 PASS 11G 2437 Ant1 100 PASS 11N20SISO 2437 Ant1 100 PASS 11N40SISO 2437 Ant1 100 PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 2 of 46 Duty Cycle_11B_2437_Ant1 Duty Cycle_11G_2437_Ant1 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 3 of 46 Duty Cycle_11N20SISO_2437_Ant1 Duty Cycle_11N40SISO_2437_Ant1 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 4 of 46 A.2 Maximum Conducted Output Power Mode Channel Meas.Level [dBm] Limit [dBm] Verdict 11B LCH 15.81 30 PASS MCH 16.31 30 PASS HCH 15.55 30 PASS 11G LCH 14.36 30 PASS MCH 16.54 30 PASS HCH 15.81 30 PASS 11N20SISO LCH 14.09 30 PASS MCH 16.43 30 PASS HCH 15.81 30 PASS 11N40SISO LCH 16.41 30 PASS MCH 16.53 30 PASS HCH 16.21 30 PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 5 of 46 A.3 Maximum Power Spectral Density Mode Channel Meas.Level [dBm/3KHz] Limit [dBm/3KHz] Verdict 11B LCH -13.811 8 PASS MCH -11.142 8 PASS HCH -14.354 8 PASS 11G LCH -18.364 8 PASS MCH -15.986 8 PASS HCH -17.187 8 PASS 11N20SISO LCH -18.965 8 PASS MCH -16.907 8 PASS HCH -18.512 8 PASS 11N40SISO LCH -19.643 8 PASS MCH -17.557 8 PASS HCH -20.042 8 PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 6 of 46 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 7 of 46 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 8 of 46 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 9 of 46 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 10 of 46 11N40SISO/LCH 11N40SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 11 of 46 11N40SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 12 of 46 A.4 6dB Bandwidth Mode Channel 6dB Bandwidth [MHz] Limit [MHz] Verdict 11B LCH 9.118 ≥0.5 PASS MCH 9.594 ≥0.5 PASS HCH 9.597 ≥0.5 PASS 11G LCH 15.16 ≥0.5 PASS MCH 15.32 ≥0.5 PASS HCH 15.72 ≥0.5 PASS 11N20SISO LCH 15.08 ≥0.5 PASS MCH 15.44 ≥0.5 PASS HCH 16.35 ≥0.5 PASS 11N40SISO LCH 35.39 ≥0.5 PASS MCH 35.17 ≥0.5 PASS HCH 35.13 ≥0.5 PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 13 of 46 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 14 of 46 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 15 of 46 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 16 of 46 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 17 of 46 11N40SISO/LCH 11N40SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 18 of 46 11N40SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 19 of 46 A.5 RF Conducted Spurious Emissions Mode Channel Pref [dBm] Max. Level [dBm] Limit [dBm] Verdic t 11B LCH 1.248 -38.332 -18.752 PASS MCH 1.962 -38.099 -18.038 PASS HCH 1.109 -37.541 -18.891 PASS 11G LCH -4.514 -37.749 -24.514 PASS MCH -2.082 -37.996 -22.082 PASS HCH -2.338 -37.530 -22.338 PASS 11N20 SISO LCH -3.382 -37.197 -23.382 PASS MCH -1.045 -37.983 -21.045 PASS HCH -2.405 -37.982 -22.405 PASS 11N40 SISO LCH -4.921 -37.685 -24.921 PASS MCH -4.562 -38.393 -24.562 PASS HCH -4.365 -38.729 -24.365 PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 20 of 46 11B_LCH_Graphs Pref/11B/LCH Puw/11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 21 of 46 11B_MCH_Graphs Pref/11B/MCH Puw/11B/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 22 of 46 11B_HCH_Graphs Pref/11B/HCH Puw/11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 23 of 46 11G_LCH_Graphs Pref/11G/LCH Puw/11G/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 24 of 46 11G_MCH_Graphs Pref/11G/MCH Puw/11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 25 of 46 11G_HCH_Graphs Pref/11G/HCH Puw/11G/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 26 of 46 11N20SISO_LCH_Graphs Pref/11N20SIS O/LCH Puw/11N20 SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 27 of 46 11N20SISO_MCH_Graphs Pref/11N20 SISO/MCH Puw/11N20 SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 28 of 46 11N20SISO_HCH_Graphs Pref/11N20 SISO/HCH Puw/11N20 SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA Page 29 of 46 11N40SISO_LCH_Graphs Pref/11N40 SISO/LCH Puw/11N40 SISO/LCH SHENZHEN LCS COMPLIANCE TES…

Text truncated - open the document above for the full version.

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 39 FCC TEST REPORT For Xiamen Yinxu Industry & Trade Co., Ltd. Smart bulb Test Model: SBR30 Additional Model No.: SG45-E12, SG45-E26, SC37, SGU10, SA60 Prepared for : Xiamen Yinxu Industry & Trade Co., Ltd. Address : No.33 Factory Building, No.10-2 Lot, Tong'an Park, Tong'an Industrial Zone, Xiamen,Fujian, 361100 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : March 14, 2021 Number of tested samples : 2 Sample number : 210312038A-1, 210312038A-2 Serial number : Prototype Date of Test : March 14, 2021 ~ March 27, 2021 Date of Report : April 01, 2021 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 39 FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCS210312038AEA Date of Issue .................................. : April 01, 2021 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : Xiamen Yinxu Industry & Trade Co., Ltd. Address .......................................... : No.33 Factory Building, No.10-2 Lot, Tong'an Park, Tong'an Industrial Zone, Xiamen,Fujian, 361100 Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. .................. : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : Smart bulb Trade Mark ..................................... : N/A Test Model ...................................... : SBR30 Ratings ........................................... : AC 110-130V, 12W Result ............................................ : Positive Compiled by: Supervised by: Approved by: Jin Wang/ File administrator Linda He/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 39 FCC -- TEST REPORT EUT......................................... : Smart bulb Test Model............................... : SBR30 Applicant............................... : Xiamen Yinxu Industry & Trade Co., Ltd. Address.................................. : No.33 Factory Building, No.10-2 Lot, Tong'an Park, Tong'an Industrial Zone, Xiamen,Fujian, 361100 Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Xiamen Yinxu Industry & Trade Co., Ltd. Address................................... : No.33 Factory Building, No.10-2 Lot, Tong'an Park, Tong'an Industrial Zone, Xiamen,Fujian, 361100 Telephone............................... : / Fax.......................................... : / Factory................................... : Xiamen Yinxu Industry & Trade Co., Ltd. Address................................... : No.33 Factory Building, No.10-2 Lot, Tong'an Park, Tong'an Industrial Zone, Xiamen,Fujian, 361100 Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS210312038AEA April 01, 2021 Date of issue SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 39 Revision History Revision Issue Date Revisions Revised By 000 April 01, 2021 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB Report No.: LCS210312038AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 39 TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 6 1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6 1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS ............................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB _______________________________________________________________________________________________ TEST SETUP PHOTOGRAPHS Photo of Radiated Emissions Measurement Below 1 GHz Above 1 GHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AZNW-WSLB _______________________________________________________________________________________________ Power Line Conducted Emission

Contact Information

Applicant

Male Lin(Manager)
[email protected]+86-592-7196111Fax: +86-592-7196111

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz45.10 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.