
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
BFSITO-260 WOLONOW Smart Body Fat Scale User Guide 90MM 90MM 风琴折页,128g哑粉字体印刷/单色 k 80 或冷灰11C /字体:阿里巴巴普惠体 材料: 工艺: 尺寸: 印刷颜色: CMYK设计:XXX版本:XX FCC Requirement FCC ID: 2AZSZ-ITO260 changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. Measuring Weight and Body Fat Please stand on the scale barefooted in the posture as shown below for measuring your weight and body fat. Stand on the scale with your feet paralleled and aligned by the center of the scale surface. Scan QR Code to download the official app Basic Parameters Product Name: WOLONOW Smart Body Fat Scale Model: BFSITO – 260 Unit of Measurement: lb Communication Mode: Bluetooth 4.0 Dimensions: 260 x 260 x25 (mm) Execution Standard: Q/XF 001-2021 Net Weight: 1.13 kg Weight Range: 5kg – 150kg Measurement Precision: ±50g Operating Ambient Temperature: - 5°C to 40°C Enclosure Material: ABS engineering plastics Battery Type: 1.5v AAA Battery x 3 More detailed information is available from www.wolonow.cn. Or, call WOLONOW’s customer service hotline 400-999-0509 for more inquiries. Manufacturer: Star Atmosphere Technology (Shenzhen) Co., LTD Address: Room 2706A, Block A, Sunshine TDI Building, Nanshan District, Shenzhen 518000, China ① Note: Please remove the insulating strip so that the product can be switched on. Product Description Thank you for choosing WOLONOW Smart Body Fat Scale Hidden High-Resolution LED Screen User Guide V1.0 WOLONOW Smart Body Fat Scale User Guide Installation of WOLONOW App Search for “WOLO” in Android App Market or App Store, or scan the QR code below to download and install WOLO App for connection with the device. The device or the app may not work properly if the app is downloaded through other channels. Before communication with your device, make sure your device is either: • iPhone / iPod Touch with the system of iOS 9.0 or above; or • Mobile phone with the system of Android 4.3 or above and with Bluetooth 4.0. Enable Bluetooth on the phone and open WOLO App After the Bluetooth on your phone is enabled and WOLO App is open, stand on the scale and measure your weight, and the data can be synched, displayed and recorded in your phone app. Imperceptible ITO Coating Please read through the user guide before using the product and keep it in good condition Warning: This product must not be used by: • Patients with a cardiac pacemaker or special population who have other electronic product to maintain their vital signs in their body. When this product is used to measure BMI, weak current flows through the human body, which current may affect the proper operation of the medical apparatus inside the body and lead to a severe consequence. • Pregnant women. Those pregnant women who need to use this product should seek for their doctor’s advice first. • This product should not be used on an unstable or slippery surface to avoid falling. Note: The device may not be able to obtain precise body data from the following people due to their special nature. Only the body weight information can be accurate. • Children in growth stage • Osteoporosis patients • Elderly people • Professional athletes • Edema patients • Patients with cold or fever • Pregnant women • Patients with dialysis Please try to avoid measuring your weight if: • The environment is humid, the scale surface is slippery or the product is not steady • You have just finish sauna and shower and your body surface is not completely dry • You have just finish intense exercises and your body is not completely quiet down • You have just drunk a large volume of water or you have just eaten • You have drunk a large volume of alcohol Before measuring your weight: • Turn on or restart the scale and wait for the“ ”icon stops flashing on the scale surface. • Keep the scale static for 5 to 10 seconds for the first time use or after moving the scale to allow calibration of the sensor with the ground. Maintenance and Care • Please use clean wet cloth to wipe to clean the scale surface. • Please do not use any detergent to clean the scale surface. Corrosive detergents may cause damage to the ITO conductive coating and affect the precision in body fat measurement. “ITO coating is used with the body fat measurement chip to measure your body fat” Scale Leg with High-Precision Sensor Battery Cover Weight Unit Information on Display Note: When the red light flashes, the battery is low. Body Fat Low Battery Weight Number Performance Fault Failure of function listed on the user guide No display / missing display on the screen Unable to switch on the device or unable to ac…
Text truncated - open the document above for the full version.
FCCID:2AZSZ-ITO260 FCCID:2AZSZ-ITO260
FCCID:2AZSZ-ITO260 FCCID:2AZSZ-ITO260 FCCID:2AZSZ-ITO260 . TheEnd
Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax: +86-755-26648637 Website: www.cqa-cert.com Report Template Version: V04 Report Template Revision Date: 2018-07-06 RF Exposure Evaluation Report The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No.: CQASZ20210500594E-02 Applicant: Star Atmosphere Technolo gy (Shenzhen) Co., LTD Address of Applicant: Room 2706A, Block A, Sunshine TDI Building, Nanshan District, Shenzhen 518000, China Equipment Under Test (EUT): EUT Name: WOLONOW Smart Body Fat Scale Model No.: BFSITO-260 Test Model No.: BFSITO-260 Brand Name: WOLONOW FCC ID: 2AZSZ-ITO260 Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2021-05-08 Date of Test: 2021-05-08 to 2021-05-18 Date of Issue: 2021-06-17 Test Result: PASS* *In the configuration tested, the EUT complied with the standards specified above Tested By: (Lewis Zhou) Reviewed By: (Sheek Luo ) Approved By: ( Jack Ai) Shenzhen Huaxia Testin g Technology Co., Ltd Report No.: CQASZ20210500594E-02 Page:2 of 6 1 Version Revision History Of Report Report No. Version Description Issue Date CQASZ20210500594E-02 Rev.01 Initial report 2021-06-17 Shenzhen Huaxia Testin g Technology Co., Ltd Report No.: CQASZ20210500594E-02 Page:3 of 6 2 Contents Page 1 VERSION ..................................................................................................................................................................... 2 2 CONTENTS ................................................................................................................................................................. 3 3 GENERAL INFORMATION ...................................................................................................................................... 4 3.1 CLIENT INFORMATION ............................................................................................................................................... 4 3.2 GENERAL DESCRIPTION OF EUT ............................................................................................................................... 4 4 SAR EVALUATION .................................................................................................................................................... 5 4.1 RF EXPOSURE COMPLIANCE REQUIREMENT .............................................................................................................. 5 4.1.1 Standard Requirement ................................................................................................................................. 5 4.1.2 Limits .............................................................................................................................................................. 5 4.1.3 EUT RF Exposure......................................................................................................................................... 6 Shenzhen Huaxia Testin g Technology Co., Ltd Report No.: CQASZ20210500594E-02 Page:4 of 6 3 General Information 3.1 Client Information Applicant: Star Atmosphere Technolo gy(Shenzhen) Co., LTD Address of Applicant: Room 2706A, Block A, Sunshine TDI Building, Nanshan District, Shenzhen 518000, China Manufacturer: Star Atmosphere Technolo gy (Shenzhen) Co., LTD Address of Manufacturer: Room 2706A, Block A, Sunshine TDI Building, Nanshan District, Shenzhen 518000, China Factory: Star Atmosphere Technolo gy (Shenzhen) Co., LTD Address of Factory: Room 2706A, Block A, Sunshine TDI Building, Nanshan District, Shenzhen 518000, China 3.2 General Description of EUT Product Name: WOLONOW Smart Body Fat Scale Model No.: BFSITO-260 Test Model No.: BFSITO-260 Trade Mark: WOLONOW Hardware Version: V1.1 Software Version: V1.5 Operation Frequency: 2402MHz~2480MHz Version: 2.4G custom Modulation Type: GFSK Transfer Rate: 1Mbps Number of Channel: 3 Product Type: Mobile Portable Fix Location Test Software of EUT: MacroGiga Test V2.0 (manufacturer declare) Antenna Type: PCB antenna Antenna Gain: 0 dBi EUT Power Supply: DC 4.5V 50M A . Shenzhen Huaxia Testin g Technology Co., Ltd Report No.: CQASZ20210500594E-02 Page:5 of 6 4 SAR Evaluation 4.1 RF Exposure Compliance Requirement 4.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 4.3.1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 4.1.2 Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation 17 The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion Shenzhen Huaxia Testin g Technology Co., Ltd Report No.: CQASZ20210500594E-02 Page:6 of 6 4.1.3 EUT RF Exposure 1) For BLE Measurement Data GFSK mode Test channel Peak Output Power (dBm) Tune up tolerance (dBm) Maximum tune-up Power (dBm) (m…
Text truncated - open the document above for the full version.
Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax: +86-755-26648637 Website: www.cqa-cert.com Report Template Version: V03 Report Template Revision Date: Mar.1st, 2017 Test Report * In the configuration tested, the EUT complied with the standards specified above. The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. 1 Cover page Report No.: CQASZ20210500594E-01 Applicant: Star Atmosphere Technology (Shenzhen) Co., LTD Address of Applicant: Room 2706A, Block A, Sunshine TDI Building, Nanshan District, Shenzhen 518000, China Equipment Under Test (EUT): EUT Name: WOLONOW Smart Body Fat Scale Model No.: BFSITO-260 Test Model No.: BFSITO-260 Brand Name: WOLONOW FCC ID: 2AZSZ-ITO260 Standards: 47 CFR Part 15, Subpart C Date of Receipt: 2021-05-08 Date of Test: 2021-05-08 to 2021-05-18 Date of Issue: 2021-06-17 Test Result: PASS* * In the configuration tested, the EUT complied with the standards specified above Tested By: (Lewis Zhou) Reviewed By: (Sheek Luo ) Approved By: ( Jack Ai) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20210500594E-01- Page:2 of 42 2 Version Revision History Of Report Report No.Version Description Issue Date CQASZ20210500594E-01 Rev.01 Initial report 2021-06-17 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20210500594E-01- Page:3 of 42 3 Test Summary Test Item Test Requirement Test method Result Antenna Requirement 47 CFR Part 15, Subpart C Section 15.203/15.247 (c) ANSI C63.10 2013 PASS AC Power Line Conducted Emission 47 CFR Part 15, Subpart C Section 15.207 ANSI C63.10 2013 N/A Conducted Peak Output Power 47 CFR Part 15, Subpart C Section 15.247 (b)(3) ANSI C63.10 2013 PASS 6dB Occupied Bandwidth 47 CFR Part 15, Subpart C Section 15.247 (a)(2) ANSI C63.10 2013 PASS Power Spectral Density 47 CFR Part 15, Subpart C Section 15.247 (e) ANSI C63.10 2013 PASS Band-edge for RF Conducted Emissions 47 CFR Part 15, Subpart C Section 15.247(d) ANSI C63.10 2013 PASS RF Conducted Spurious Emissions 47 CFR Part 15, Subpart C Section 15.247(d) ANSI C63.10 2013 PASS Radiated Spurious Emissions 47 CFR Part 15, Subpart C Section 15.205/15.209 ANSI C63.10 2013 PASS Restricted bands around fundamental frequency (Radiated Emission) 47 CFR Part 15, Subpart C Section 15.205/15.209 ANSI C63.10 2013 PASS N/A: The EUT is powered by AAA battery, So Not Applicable Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20210500594E-01- Page:4 of 42 4 Contents Page 1 COVER PAGE ......................................................................................................................................................... 1 2 VERSION .................................................................................................................................................................. 2 3 TEST SUMMARY .................................................................................................................................................... 3 4 CONTENTS .............................................................................................................................................................. 4 5 GENERAL INFORMATION ................................................................................................................................... 5 5.1 CLIENT INFORMATION .......................................................................................................................................... 5 5.2 GENERAL DESCRIPTION OF EUT .......................................................................................................................... 5 5.3 ADDITIONAL INSTRUCTIONS ................................................................................................................................. 7 5.4 TEST ENVIRONMENT ............................................................................................................................................ 8 5.5 DESCRIPTION OF SUPPORT UNITS ......................................................................................................................... 8 5.6 STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................. 9 5.7 TEST LOCATION ................................................................................................................................................. 10 5.8 TEST FACILITY ................................................................................................................................................... 10 5.9 DEVIATION FROM STANDARDS ........................................................................................................................... 10 5.10 OTHER INFORMATION REQUESTED BY THE CUSTOMER ...................................................................................... 10 5.11 EQUIPMENT LIST ................................................................................................................................................ 11 6 TEST RESULTS AND MEASUREMENT DATA .............................................................................................. 12 6.1 ANTENNA REQUIREMENT ................................................................................................................................... 12 6.2 CONDUCTED PEAK OUTPUT POWER ................................................................................................................... 13 6.3 6DB OCCUPY BANDWIDTH ................................................................................................................................. 16 6.4 POWER SPECTRAL DENSITY .............................................…
Text truncated - open the document above for the full version.
FCCID:2AZSZ-ITO260 9KHz~30MHz: 30MHz~1GHz: Above1GHz: FCCID:2AZSZ-ITO260 FCCID:2AZSZ-ITO260 Above1GHz:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.11 mW |

WOLONOW Smart Dual-Mode Jumping Rope
Equipment Class
DTS - Digital Transmission System