FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HAWORTH, INC./
  3. 2AZT6-MRJ8011-PLUS

2AZT6-MRJ8011-PLUSBELONG POWER SUITE

HAWORTH, INC.
BELONG POWER SUITE - FCC ID 2AZT6-MRJ8011-PLUS - HAWORTH, INC.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 26, 2023
Application Purpose
Original Equipment
Date of Application
Jul 26, 2023
Equipment Note
BELONG POWER SUITE
Frequency Range
0.11100000 - 0.20500000
Company
HAWORTH, INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Form Number:BST-QW-RD-020- R04-1.0 PRODUCTS SPECIFICATION MODEL: MRJ8011-PLUS NAME: U.S. POWER STRIP WRITTEN: Jiang Lincheng/Li Jianping Date: 2023-06-14 CHECKED: Date: APPROVED: Date: Address: No. 358, Baotian 1st Road, Tiegang Village, Xixiang Town, Baoan District, Shenzhen ADD:Eastern Side of Floor 3,NO.358,Baotian 1st Road,Tiegang Community,Xixiang Street, Bao'an District Shenzhen City,Guangdong Province,China TEL:+86-755-88823234(10 lines) FAX:+86-755-29977791 File name 产 品 规 格 书 Product model MRJ8011-PLUS Drafteddat e 2023-06-14 版本 REV1. 0 第 2 页 共 14 页 Form Number:BST-QW-RD-020-R04-1.0 version Revised Content Formulated/date d Review/Date Approval/date V1.0 The first version was developed 20230614 File name 产 品 规 格 书 Product model MRJ8011-PLUS Drafteddat e 2023-06-14 版本 REV1. 0 第 3 页 共 14 页 Form Number:BST-QW-RD-020-R04-1.0 Contents 1. 5Product Overview 5 3 ............................................................................................................................................. 5 2. Error! Bookmark not defined.Product model naming method: Error! Bookmark not defined. 4 ........................................................................................... Error! Bookmark not defined. 3. 5Product Figure 5 4 ............................................................................................................................................. 5 4. 7Product characteristic parameters 7 4 ............................................................................................................................................. 7 5. 9Performance indicators ............................................................................................................................................ 9: 9 6 ............................................................................................................................................. 9 95.1Input characteristic 9 6 .................................................................................................................................. 9 95.2Output characteristics 9 6 .................................................................................................................................. 9 5.2.1 9Rated output 9 6 ........................................................................................................................ 9 5.2.2 11Steady-state output characteristics 11 6 ...................................................................................................................... 11 5.2.3 11Power on and off characteristics 11 6 ...................................................................................................................... 11 125.3Protection function 12 7 ................................................................................................................................ 12 5.4 ................................................................................................................ 12Indicator 12 7 ................................................................................................................................ 12 6. 13Security requirements File name 产 品 规 格 书 Product model MRJ8011-PLUS Drafteddat e 2023-06-14 版本 REV1. 0 第 4 页 共 14 页 Form Number:BST-QW-RD-020-R04-1.0 13 7 ........................................................................................................................................... 13 6.1 13Safety Standard 13 7 ................................................................................................................................ 13 6.2 13Electrical strength test 13 7 ................................................................................................................................ 13 6.3 13Insulation impedance 13 8 ................................................................................................................................ 13 7. 13Electromagnetic compatibility 13 8 ........................................................................................................................................... 13 7.1 Electromagnetic interference ................................................................................................................................ 9 .................................................................................................................................... 7.2 Electromagnetic immunity ................................................................................................................................ 9 .................................................................................................................................... 8. Environmental requirements ........................................................................................................................................... 9 ............................................................................................................................................... 8.1 Ambient temperature ................................................................................................................................ 9 .................................................................................................................................... 8.2 Ambient humidity ................................................................................................................................ 9 .................................................................................................................................... 8.3 ...................................................................................................................... Altitude ................................................................................................................................ 9 .................................................................................................................................... 8.4…

Text truncated - open the document above for the full version.

Attestation Statements

1/1 US Agent for Service of ProcessLETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: HAWORTH, INC. FRN: 0030902324 Contact Name: Ross. Koning Address:One Haworth Center, Holland, MI 49423-9576 USA Telephone No: (616) 836-6996 Email: [email protected] Applicant: Company name: HAWORTH, INC. Product Description: BELONG POWER SUITE Grantee code: 2AZT6 FCC ID: 2AZT6-MRJ8011-PLUS Contact Name: Ross. Koning Address: One Haworth Center, Holland, MI 49423-9576 USA Telephone No: (616) 836-6996 Email: [email protected] [HAWORTH, INC.] certifies that, as of the date of this filing of the application with the TCB, [HAWORTH, INC.] is our designated US agent for service of process for the above referenced FCC ID. [HAWORTH, INC.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [HAWORTH, INC.] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicantis aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. 1/1 Date: 20/07/2023 Applicant’s Name:Ross. Koning US Agent’s Name: Ross. Koning Title:manager Title: manager Signature Signature

Attestation Statements

C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: HAWORTH, INC. Grantee code: 2AZT6 FCC ID: 2AZT6-MRJ8011-PLUS Contact Name: Ross. Koning Address: One Haworth Center, Holland, MI 49423-9576 USA Telephone No: (616) 836-6996 Fax No: N/A Email: [email protected] i. [HAWORTH, INC.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [HAWORTH, INC.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. Theapplicantmustsignthiscertification. HAWORTH, INC. certifies that, as of the date of the filing of theapplication, the applicant is notidentified on the Covered List as an entity producing “covered”equipment. Date: 09/05/2023 Applicant’s Name: Ross. Koning Title:General Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

HAWORTH, INC. Family models declaration letter. 7/20/2023 We Company: HAWORTH, INC. Address: One Haworth Center, Holland, MI 49423-9576 USA Product: BELONG POWER SUITE Model Name: 79280702 Family Model: MRJ8011-PLUS All models are the same circuit and RF module, except the model name. We (HAWORTH, INC.) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.), same mechanical structure and design (including product enclosure, materials, etc.), the only difference is the model name. Thanks Sincerely, Signature [Name] Ross. Koning [Title] Gernal manager [email protected]

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization < HAWORTH, INC.> Company: HAWORTH, INC. Address:One Haworth Center, Holland, MI 49423-9576 USA Product Name:BELONG POWER SUITE Model Number: 79280702, MRJ8011-PLUS FCC Identifier:2AZT6-MRJ8011-PLUS We authorize LGAI Technological Center S.A., Ronda de la Font delCarme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Ross. Kong Date: 20/07/2023 Title: General Manager Signature of applicant: Name: Ross. Koning

Cover Letter(s)

C5266091_X10_Ed.2 1/1 < HAWORTH, INC.> Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046Date: 20/07/2023 Subject: Request for Confidentiality FCC ID: 2AZT6-MRJ8011-PLUS To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location Attestation Statement External Photos Block Diagram Schematics Test Report Test Setup Photos User’s Manual NOTE 1 Internal Photos NOTE 1 Parts List / Tune Up / BOM List RF Exposure Info Operational Description Cover Letter(s) FCC Software Security Requirements for UNII devices NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of _180_ days from the date of the Grant of Equipment Authorization and prior to marketing. C5266091_X10_Ed.2 1/1 It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Ross. Koning Title: General Manager

External Photos

ATTACHMENT PHOTOGRAPHS OF EUT Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6

ID Label/Location Info

1 A 2345678 B C D A B C D 12345678 DRAWING TITLE DRAWING NUMBER REVISION SIZE 3RD ANGLE 45° .086 [2.18] .154 [3.92] .154 [3.92] REF .086 [2.18] .166 [4.21] .416 [10.57] .166 [4.22] REF 1.516 [38.5] 1.736 [44.1] 3.252 [82.6] 1.111 [28.21] .05 [1.2] 1.101 [27.98] 1.101 [27.98] REF .38 [9.6] .750 [19.05] .335 [8.51] REF .667 [16.94] .086 [2.18] .667 [16.94] REF .335 [8.51] .83 [21.2] .50 [12.7] .50 [12.7] REF .75 [19.1] .363 [9.22] .50 [12.7] .750 [19.05] .975 [24.77] .975 REF [24.78] .086 [2.18] REVISIONS DATE DD-MMM-YYYY CHGD/ENGRDESCRIPTIONREV 21-APR-2020KAH/MM ENGINEERING RELEASE PER ECO 298-797. 1 6-JUN-2020KAH/MM ADDED TEXTURE CALLOUTS AND RELATED TEXTURE NOTES. UPDATED PLUG NOTE 15 PER ECO 298-797. 1.6 10-JUL-2020KAH/MM ADDED NOTE 19 AND UPDATED VIEWS SHOWING UPDATED TEXT AND L.E.D. INDICATOR PER ECO 298-797. 1.7 15-JUL-2020KAH/MM UPDATED DRAWING AND VIEWS PICTORALLY PER SUPPLIER CAD DATE PER ECO 298-797. 1.8 30-SEP-2020KAH/MM DELETED P/N 79280201. REMOVED NOTES 12 AND 18 . DELETED ITEM 2 FROM B.O.M. PER ECO 298-797. 2 15-FEB-2021KAH/KING ADDED NUMEROUS DIMENSIONS, DETAIL VIEWS, AND UPDATED NUMEROUS NOTES PER ECO 298-797. 3 MATERIAL SEE NOTES DIMENSIONS INCH [METRIC] TOLERANCES EXCEPT AS NOTED: .XXX = ±.010 [.25] .XX = ±.03 [.76] ANGLES = ±2° FINISH SEE NOTES POWER SUITE, BELONG HAWORTH INC. CLAIMS PROPRIETARY RIGHTS TO THE MATERIAL DISCLOSED HEREON. THIS DRAWING AND/OR TECHNICAL INFORMATION IS THE PROPERTY OF HAWORTH INC. AND IS ISSUED IN CONFIDENCE FOR USE ONLY AS AUTHORIZED, AND MAY NOT BE REPRODUCED OR DESCRIBED OR SHOWN TO OTHERS WITHOUT WRITTEN PERMISSION FROM HAWORTH INC. D 792802003.5 SCALE 0.8751 OF 1 PART NUMBER REVDESCPSAP_MAT_NUMBER 792802023POWER SUITE, 3 PWR, 2 USB-A, 1 USB-C, QI135-4830 LIST OF MATERIALS DESCRIPTIONITEM PACKAGING0 POWER SUITE1 INSTALLATION INSTRUCTION (61000139)3 SCALE 0.500 SEE DETAIL B SEE DETAIL C SEE DETAIL D SEE DETAIL E 10 DETAIL A SCALE 1.750 12 DETAIL B SCALE 1.750 12 DETAIL C SCALE 3.000 20 DETAIL D SCALE 2.000 22 DETAIL E SCALE 2.000 12 76.2mm 5002764 Part NO: 79280702 BELONG POWER SUITE AC: 125V~,60HZ,15A 5V 3A 9V 3A 12V 3A 15V 3A 20V 3.25A 65W Max 5V 3A 9V 3A 12V 3A 15V 3A 20V 3A 60W Max + USB-C1+C2 Output: 45W+20W 65W Max + USB-C1+A Output: 45W+18W 63W Max + USB-C2+A Output: 5V 3A 15W Max + + USB-C1+C2+A Output: 45W+15W 60W Max Wireless Charger: 15W MAX Total USB Ouput: 65W MAX ETL LISTED 5002764 CONFORMS TO UL STD. 962A CERTIFIED TO CSA STD. C22.2 NO. 308 CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, USE INDOORS ONLY. DO NOT PLUG INTO ANOTHER POWER TAP. FOR USE IN DRY LOCATIONS ONLY. MADE IN CHINA Attention: Afin de réduire les risques de choc électrique, utiliser à l'intérieur seulement et utiliser uniquement dans des endroits secs. FCC ID: 2AZT6-MRJ8011-PLUS OR USB-A Output: USB-C1/C2 Output: Scan for Charging Guide

Internal Photos

Photo 7 Photo 8 Photo 9 Photo 10 Induction coil Photo 11 Photo 12 Photo 13 Photo 14 Photo 15 Photo 16 Photo 17 Photo 18

RF Exposure Info

FCC ID: 2AZT6-MRJ8011-PLUS 1.Measuring Standard FCC Part 1(1.1310) and Part 2(2.1091), KDB 680106 D01v03r01 RF Exposure Wireless Charging App v03 1.2. Requiments Three different categories of transmitters are defined by the FCC in OET Bulletin 65. These categories are fixed installation, mobile, and portable and are defined as follows: o Fixed Installations: fixed location means that the device, including its antenna, is physically secured at a permanent location and is not able to be easily moved to another location. Additionally, distance to humans from the antenna is maintained to at least 2 meters. o Mobile Devices: a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to be generally used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structures and the body of the user or nearby persons. Transmitters designed to be used by consumers or workers that can be easily re-located, such as a wireless modem operating in a laptop computer, are considered mobile devices if they meet the 20 centimeter separation requirement. The FCC rules for evaluating mobile devices for RF compliance are found in 47 CFR §2.1091. o Portable Devices: a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable device requirements are found in Section 2.1093 of the FCC's Rules (47 CFR§2.1093). The FCC also categorizes the use of the device as based upon the user’s awareness and ability to exercise control over his or her exposure. The two categories defined are Occupational/ Controlled Exposure and General Population/Uncontrolled Exposure. These two categories are defined as follows: Occupational/Controlled Exposure: In general, occupational/controlled exposure limits are applicable to situations in which persons are exposed as a consequence of their employment, who have been made fully aware of the potential for exposure and can exercise control over their exposure. This exposure category is also applicable when the exposure is of a transient nature due to incidental passage through a location where the exposure levels may be higher than the general population/uncontrolled limits, but the exposed person is fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. Awareness of the potential for RF exposure in a workplace or similar environment can be provided through specific training as part of a RF safety program. If appropriate, warning signs and labels can also be used to establish such awareness by providing prominent information on the risk of potential exposure and instructions on methods to minimize such exposure risks. General Population/Uncontrolled Exposure: The general population / uncontrolled exposure limits are applicable to situations in which the general public may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Members of the general public would come under this category when exposure is not employment-related; for example, in the case of a wireless transmitter that exposes persons in its vicinity. Warning labels placed on low-power consumer devices such as cellular telephones are not considered sufficient to allow the device to be considered under the occupational/controlled category, and the general population/uncontrolled exposure limits apply to these devices. 1.3 Test configuration 1, The field strength of both E-field was measured at 15cm, H-field was measured at 15cm surrounding the device, and 20 cm away from the surface from all coils using the equipment list above for determining compliance with the MPE requirements of FCC Part 1.1310. 2, The RF power density was measured at Under maximum load test 3, Maximum E-field measurements was made 15cm from each side of the EUT and H-field measurements was made 15cm from surrounding the EUT and 20 cm away from the surface from all coils. Along the side of the EUT and still 20cm away from the edge of the EUT, the field probes were positioned at the location where there is maximum field strength. The maximum E-field and H-field is reported below. 4, This device uses a wireless charging circuit for power transfer operating at the frequency of 111–205kHz. Thus, the 300kHz limits were used: E-field Limit = 614 (V/m); H-field limit = 1.63 (A/m). 1.4 Test Setup 2. Limits 3. MEASURING DEVICE AND TEST EQUIPMENT 3.1 Test Instruments Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Due day 1 Exposure Level Tester narda ELT-400 N-0231 2022.09.01 2023.08.31 2 Magnetic field probe 100cm2 narda ELT probe 100cm2 M0675 2022.09.01 2023.08.31 3 Isotropic Electric Field Probe narda EP-601 511WX60706 2022.09.08 2023.09.07 3.2 Measurement Uncertainty (95% confidence levels, k=2) No. Item Uncertainty 1 Uncertainty for H-Field 2.39dB 2 Uncertainty for E-Field 2.45dB 4. Measuring Results EUT: BELONG POWER SUITE Model Name. : 79280702 Temperature: 24 °C Relative Humidity: 56% Pressure: 1010hPa Test Date: 2023-6-01 Test Voltage: AC120V/60Hz For Full load mode: E-Field Strength at 15 cm for position A,B,C,D 20cm for position E from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limit (50%) (V/m) Limits Test (V/m) 0.111-0.205 4.424 3.986 3.809 4.074 4.532 307 614 H-Filed Strength at 15 cm for position A,B,C,D 20cm for position E from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limit (50%) (A/m) Limits Test (A/m) 0.111-0.205 0.566 0.762 0.549 0.824 0.689 0.815 1.63 For Null load mode: E-Field Str…

Text truncated - open the document above for the full version.

Test Report

(Wireless charging category) SPECIFICATION FOR APPROVAL SPECIFICATON APPROVAL 客户名称 HAWORTH, INC. CustomerName: 产品名称 roducts: 项目编号 ProjectNumber:YC811 送样日期 DeliveryDate:20211230 样板承认书编号:A1120211230-01 sign projectqualitymarketreviewapprove customer signature purchase R&D qualityprojectapprove 蒋林城 王赳骅 深圳市阅川电子有限公司 Shenzhen Yuechuan Electronics Co., Ltd. No. 07, 6th Floor, Dongfang Science and Technology Building, No. 16 Keyuan Road, Yuehai Street, Nanshan District, Shenzhen Transmitting Magnetic Coil Specification 规格内容 20.5*43*50*1.0*10T CISTOMEP/N: 客户品名 A11 Coil PARTNUMBER : 制造商料号 WMRTA11-10T 1.DIMENSIONS(外形尺寸): Note: 1. The overall appearance is clean and tidy, and the details are subject to the signed sample 2. Appearance Visually, the surface is smooth and flat, no flash, no burr, no sink mark, no weld marks, particles and scratches, and the appearance is poor APPROVEDBY 承认 CHECKEDBY 审 查 PREPAREDBY 制作 DATE 日期 PACE 页 码 20 21 /1 2/3 02 of 4 Specification 规格内容 20.5*43*50*1.0*10T CISTOMEP/N: 客户品名 A11 Coil PARTNUMBER: 制造商料号 WMRTA11-10T 5.WINDINGDETAILS(绕线详细说明): Wdy.NO. 绕 组 Start 开始 Finish 结束 Turns 圈数 WireDia 线径 Wdg.TyepeSprad/lose 绕线方法疏/密绕 Wdg.Direction 绕线方向 Turns/Layer 层数/每层圈数 1SF10TS Multi-strand wire covered wire tightly wound counter / clockwise 1 层 /10TS 公差±0.5TS 6.ELECTRICALCHARACTERISTICS(电气特性): PARAMETERSUNINLIMTI Inductancels@100KHz/1vuh 6.3uH±10% DCR@100KHz/1v Ω65m ΩMAX 未注明参数公差±5% 备注: APPROVEDBY 承 认 CHECKEDBY 审 查 PREPAREDBY 制 作 DATE 日期 PAGE 页码 20 21 /1 2/303 of 4

Test Report

Report No.: S23032903605001 Version.1.1Page 1 of 26 FCC Test Report FCC ID: 2AZT6-MRJ8011-PLUS Product: BELONG POWER SUITE Trade Name: HAWORTH Model Number: 79280702 Family Model: MRJ8011-PLUS Report No.: S23032903605001 Prepared for HAWORTH, INC. One Haworth Center, Holland, MI 49423-9576 USA Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, SanweiCommunity,Xixiang Street, Bao’an District, Shenzhen P.R. China Tel:400-800-6106,0755-2320 0050 / 2320 0090 Website:http://www.ntek.org.cn Report No.: S23032903605001 Version.1.1Page 2 of 26 TEST RESULTCERTIFICATION Applicant’s name ................. : HAWORTH, INC. Address ................................. : One Haworth Center, Holland, MI 49423-9576 USA Manufacturer's Name .......... : Guangdong BESTEK Medical Devices Co.,Ltd Address ................................. : 602, Block B, No.8 Changfa Middle Road, Yangmei Community, Bantian Street, Longgang District, Shenzhen City Factory 's Name ................... : Guangdong BESTEK Medical Devices Co., Ltd--Heyuan Branch office Address ................................. : 2nd Floor, No. 5 Xing'an South Road, Zicheng Industrial Park, Zicheng Town, Zijin County, Heyuan City Product Name: BELONG POWER SUITE Model and/or type reference : 79280702 Family Model: MRJ8011-PLUS Standards ............................. : FCC part 15C ANSI C63.10:2013 KDB 680106 D01 RF Exposure Wireless Charging App v03r01 This device described above has been tested by ShenzhenNTEK Testing Technology Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ShenzhenNTEK Testing Technology Co., Ltd., this document may be altered or revised by Shenzhen NTEK Testing Technology Co., Ltd., personnel only, and shall be noted in the revision of the document. The test results of this report relate only to the tested sample identified in this report. Date of Test ............................................ : TestSampleNumber............................: S230329036002 Date (s) of performance of tests ............. : Mar 30. 2023 ~ Jun 05. 2023 Date of Issue ........................................... : Jun 05. 2023 Test Result ............................................... : Pass Testing Engineer : (Gavan Zhang) Authorized Signatory : (Alex Li) Report No.: S23032903605001 Version.1.1Page 3 of 26 Table of Contents Page 1 . TEST SUMMARY 4 1.1 FACILITIES AND ACCREDITATIONS 5 1.2 LABORATORY ACCREDITATIONS AND LISTINGS 5 1.3 MEASUREMENT UNCERTAINTY 5 2 . GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF EUT 8 2.2 DESCRIPTION OF TEST SETUP 10 2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL 12 2.4 MEASUREMENT INSTRUMENTS LIST 13 3 . EMC EMISSION TEST 14 3.1 CONDUCTED EMISSION MEASUREMENT 14 3.1.1 POWER LINE CONDUCTED EMISSION 14 3.1.2 TEST PROCEDURE 15 3.1.3 TEST SETUP 15 3.1.4 EUT OPERATING CONDITIONS 15 3.1.5 TEST RESULTS 16 3.2 RADIATED EMISSION MEASUREMENT 18 3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 18 3.2.2 TEST PROCEDURE 19 3.2.3 TEST SETUP 20 3.2.4 TEST RESULTS 21 4. BANDWIDTH TEST 24 4.1TEST PROCEDURE 24 4.2TEST SETUP 24 4.3 TEST RESULT 25 5. ANTENNA APPLICATION 26 5.1 Antenna Requirement 26 5.2 Result 26 Report No.: S23032903605001 Version.1.1Page 4 of 26 1. TEST SUMMARY Test procedures according to the technical standards: EMC Emission Standard Test Item FCC Rules Limit Judgment Remark FCC part 15C ANSI C63.10:2013 Conducted Emission §15.207 / PASS Radiated Emission §15.209 / PASS ANTENNA APPLICATION §15.203 / PASS 20dB BANDWIDTH §15.215 / PASS NOTE: (1)’N/A’ denotes test is not applicable in this Test Report (2) For client’s request and manual description, the test will not be executed. Report No.: S23032903605001 Version.1.1Page 5 of 26 1.1 FACILITIES AND ACCREDITATIONS All measurement facilities used to collect the measurement data are located at 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen 518126 P.R. China. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 and CISPR Publication 22. 1.2 LABORATORY ACCREDITATIONS AND LISTINGS Site Description CNAS-Lab. : The Certificate Registration Number is L5516. IC-Registration : The Certificate Registration Number is 9270A-1. FCC- Accredited : Test Firm Registration Number:463705. Designation Number: CN1184 A2LA-Lab. : The Certificate Registration Number is 4298.01 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005General requirements for the competence of testing and calibration laboratories. This accreditation demonstratestechnical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Name of Firm : Shenzhen NTEK Testing Technology Co., Ltd. Site Location : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen 518126 P.R. China. 1.3 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE NTEKC01 ANSI 150 KHz ~ 30MHz 2.8 B. Radiated Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE NTEKA01 ANSI 9KHz ~1000MHz 2.64 1GHz ~12.4GHz 2.40 C. Occupied Bandwidth: Uncertainty ±3.7dB Report No.: S23032903605001 Version.1.1Page 6 of 26 Report No.: S23032903605001 Version.1.1Page 7 of 26 Revision History Report No. Version Description Issued Date S23032903605001 Rev.01 Initial issue of report Jun 05. 2023 Report No.: S23032903605001 Version.1.1Page 8 of 26 2. GENERAL INFORMATION 2.1G…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Measurement Photos AC Conducte…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ross. koning
[email protected]6168366996Fax: 616 836 6996

Technical Contact

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]86-755-6115 6588

Shenzhen · China

Non-Technical Contact

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]86-755-6115 6588

Test Firm

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]+86-755-6115-9384

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.111 MHz - 0.205 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from HAWORTH, INC.

BELONG POWER CUBE - FCC ID 2AZT6-MRJ3008-PLUS - HAWORTH, INC.
2AZT6-MRJ3008-PLUS

BELONG POWER CUBE

Jul 26, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz