Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Manual Page 1 of 32 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Tel: +49 5734 51466 - 0 Technical data might change [email protected]; www.deuta-controls.net Fax:+49 5734 51466 - 28 EnoPuck ® CO2 EnoPuck ® CO2 NOISE EnoPuck ® CO2 WALL EnOcean Sensor and RGB-LED for CO2 and sound pressure level measurement EnOcean / 902 MHz / FCC Version 1.02 EnoPuck ® CO2 / CO2 NOISE / CO2 WALL Product manual Page 2 of 32 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Tel: +49 5734 51466 - 0 Technical data might change [email protected]; www.deuta-controls.dnet Fax:+49 5734 51466 - 28 © 2022 DEUTA Controls GmbH All rights reserved This manual, including all figures and illustrations, is copyright-protected. Any further use of this manual by third parties that violate pertinent copyright provisions is prohibited. Reproduction, translation, electronic and phototechnical filing/archiving (e.g., photocopying) as well as any amendments require the written consent of DEUTA Controls GmbH, Bergisch Gladbach, Germany. Non-observance will involve the right to assert damage claims. DEUTA Controls GmbH Paffrather Straße 140 51465 Bergisch Gladbach Phone: +49 2202 28557-61 Fax: +49 2202 28557-79 E- Mail: [email protected] Web: www.deuta-controls.net Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation. However, as errors can never be fully excluded, we always appreciate any information or suggestions for improving the documentation. E- Mail: [email protected] EnoPuck ® CO2 / CO2 NOISE / CO2 WALL Product manual Page 3 of 32 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Tel: +49 5734 51466 - 0 Technical data might change [email protected]; www.deuta-controls.dnet Fax:+49 5734 51466 - 28 Table of contents 1.1 About this manual ................................................................................................... 6 1.2 Notes about this Manual .......................................................................................... 6 1.3 Validity of this documentation .................................................................................. 7 1.4 Symbols / Information on safety .............................................................................. 8 2 Information on product safety ......................................................................................... 9 2.1 Intended use ........................................................................................................... 9 2.2 Predictable incorrect application .............................................................................10 2.3 Qualification of personnel .......................................................................................11 2.3.1 EnoPuck ® CO2 / EnoPuck ® CO2 NOISE .........................................................11 2.3.2 EnoPuck ® CO2 WALL .....................................................................................11 3 Disposal ........................................................................................................................12 4 Device description .........................................................................................................13 4.1 Functionality ...........................................................................................................13 4.2 Multi-Sensor with EnOcean interface .....................................................................13 4.3 RGB-LED with local or remote control ....................................................................13 4.4 Factory settings ......................................................................................................14 4.5 External product interface ......................................................................................14 4.5.1 EnoPuck ® CO2 / EnoPuck ® CO2 NOISE .........................................................14 4.5.2 EnoPuck ® CO2 WALL .....................................................................................15 4.6 Observe intended use ............................................................................................16 4.7 Observe statutory provisions for operating frequency range. ..................................16 4.8 Non-conduction mounting surface ..........................................................................16 5 Technical data ...............................................................................................................17 5.1 Communication / EnOcean wireless interface ........................................................17 5.2 Sensor: CO2 concentration ....................................................................................17 5.3 Sensor: Rel. humidity (RH) .....................................................................................17 5.4 Sensor: Temperature .............................................................................................17 5.5 Sensor: Ambient light / brightness ..........................................................................18 5.6 Sensor: Sound pressure level (only EnoPuck® CO2 NOISE) .................................18 EnoPuck ® CO2 / CO2 NOISE / CO2 WALL Product manual Page 4 of 32 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Tel: +49 5734 51466 - 0 Technical data might change [email protected]; www.deuta-controls.dnet Fax:+49 5734 51466 - 28 5.7 Sensor: Motion / PIR ..............................................................................................18 5.8 User interfaces .......................................................................................................1…
Text truncated - open the document above for the full version.
ANTENNA DECLARATION FCC ID: 2AZTH-AL-602-XX-902 The antenna is a simple wire antenna and fixed integrated as PCB antenna. The device is tested and certified under CFR47 §15.249 Operation within the bands 902 – 928 MHz, 2400 – 2483.5 MHz, 5725 – 5875 MHz and 24.0 – 24.25 GHz. All compliance measurements (Test Report F221482E1 issued by PHOENIX TESTLAB GmbH) are performed radiated and therefore additional antenna gain documentation is not required. The internal photo exhibit clearly indicates the position and dimensions of the PCB antenna.
Long/Short-term Confidentiality Request PHOENIX TESTLAB GmbH Product Certification Koenigswinkel 10 D 32825 Blomberg 2022-11-22 FCC ID: 2AZTH-AL-602-XX-902 To Whom it may concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby request long-term confidential treatment of information accompanying this application as outlined below: ☒ Schematics ☐ Parts List ☒ Block Diagram ☐ Tune-Up Info ☒ Operational Description In addition, we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure ☐ for an initial period of 180 days ☐ until: ☒ not applicable ☐ External Photos ☐ Test Setup Photos ☐ Internal Photos ☐ Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. If you have any questions, please feel free to contact me. Yours sincerely, Sabrina Berghahn Authorized Agent
Page 1 of 3 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Tel: +49 5734 51466 - 0 Technische Änderungen vorbehalten [email protected]; www.deuta-controls.net Fax:+49 5734 51466 - 28 External photos / 12562 AL-602-01-902 Figure 1: Top view Product data sheet Page 2 of 3 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Phone.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Phone: +49 5734 51466 - 0 Technical data might change [email protected]; www.deuta-controls.dnet Fax:+49 5734 51466 - 28 External photos / 12562 AL-602-01-902 Figure 2: Bottom view Product data sheet Page 3 of 3 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Phone.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Phone: +49 5734 51466 - 0 Technical data might change [email protected]; www.deuta-controls.dnet Fax:+49 5734 51466 - 28 External photos / 12562 AL-602-01-902 Figure 3: Side view
External Photographs Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 1 of 4 EUT 1 - top view EUT 1 - bottom view External Photographs Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 2 of 4 EUT 1 - DC connector view Standard power adapter (PA1) External Photographs Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 3 of 4 EUT 2 - top view EUT 2 - bottom view External Photographs Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 4 of 4 In-wall power adapter (PA2)
Lable Location Info Additional Variant not covered by Test Report
Page 1 of 4 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Tel: +49 5734 51466 - 0 Technische Änderungen vorbehalten [email protected]; www.deuta-controls.net Fax:+49 5734 51466 - 28 Internal photos / 12562 AL-602-01-902 Figure 1: Internal, top view of PCB with housing Page 2 of 4 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Phone.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Phone: +49 5734 51466 - 0 Technical data might change [email protected]; www.deuta-controls.dnet Fax:+49 5734 51466 - 28 Internal photos / 12562 AL-602-01-902 Figure 2: Internal, bottom view of PCB with housing Page 3 of 4 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Phone.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Phone: +49 5734 51466 - 0 Technical data might change [email protected]; www.deuta-controls.dnet Fax:+49 5734 51466 - 28 Internal photos / 12562 AL-602-01-902 Figure 3: Side view of PCB, CO2 sensor Page 4 of 4 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Phone.:+49 2202 285 57- 61 23.11.2022 Hauptstraße 76, 32479 Hille Phone: +49 5734 51466 - 0 Technical data might change [email protected]; www.deuta-controls.dnet Fax:+49 5734 51466 - 28 Internal photos / 12562 AL-602-01-902 Figure 4: Side view of PCB, power connector
Internal Photographs Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 1 of 3 EUT 1 – PCB internal Top view EUT 2 - PCB internal view Internal Photographs Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 2 of 3 PCB internal Side/ Bottom view PCB Antenna Internal Photographs Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 3 of 3 RF Modul without shielding provided by the applicant
Königswinkel 10 32825 Blomberg, Germany Phone: +49 (0) 52 35 / 95 00-0 Fax: +49 (0) 52 35 / 95 00-10 [email protected] www.phoenix-testlab.de Test Report Report Number: F221482E1 Equipment under Test (EUT): EnOcean Sensor EnoPuck AL-602-02-902 EnoPuck CO2 NOISE / FCC AL-602-04-902 EnoPuck CO2 WALL / FCC Applicant: DEUTA Controls GmbH Manufacturer: DEUTA Controls GmbH Examiner: Mohamed Yassine KHALEK Report Number: F221482E1 Date of Issue: 28.11.2022 Order Number: 22-111482 Page 2 of 34 References [1] ANSI C63.10: 2013 American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices [2] FCC CFR 47 Part 15 Radio Frequency Devices [3] RSS-210 Issue 10 (December 2019) Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment [4] RSS-Gen Issue 5 (April 2018) Amendment 1 (March 2019) Amendment 2 (February 2021) General Requirements for Compliance of Radio Apparatus Examiner: Mohamed Yassine KHALEK Report Number: F221482E1 Date of Issue: 28.11.2022 Order Number: 22-111482 Page 3 of 34 Test Result The requirements of the tests performed as shown in the overview (clause 4) were fulfilled by the equipment under test. The complete test results are presented in the following. “Passed” indicates that the equipment under test conforms with the relevant limits of the testing standard without taking any measurement uncertainty into account as stated in clause 1.3 of ANSI C63.10 (2013). However, the measurement uncertainty is calculated and shown in this test report. T h i s t e s t r e p o r t i s o n l y v a l i d i n i t s o r i g i n a l f o r m. Any reproduction of its contents in extracts without written permission of the accredited test laboratory PHOENIX TESTLAB GmbH is prohibited. The test results herein refer only to the tested sample. PHOENIX TESTLAB GmbH is not responsible for any generalisations or conclusions drawn from these test results concerning further samples. Any modification of the tested samples is prohibited and leads to the invalidity of this test report. Each page necessarily contains the PHOENIX TESTLAB Logo and the TEST REPORT NUMBER. Tested and written by: Signature Reviewed and approved by: Signature Examiner: Mohamed Yassine KHALEK Report Number: F221482E1 Date of Issue: 28.11.2022 Order Number: 22-111482 Page 4 of 34 Contents: Page Identification ................................................................................................................................. 5 1.1 Applicant ................................................................................................................................................... 5 1.2 Manufacturer ............................................................................................................................................ 5 1.3 Test Laboratory ........................................................................................................................................ 5 1.4 EUT (Equipment under Test) ................................................................................................................... 6 1.5 Technical Data of Equipment ................................................................................................................... 7 1.6 Dates ........................................................................................................................................................ 8 Operational States ........................................................................................................................ 9 Overview ..................................................................................................................................... 12 Results........................................................................................................................................ 13 4.1 Conducted emissions on AC power supply lines ................................................................................... 13 4.1.1 Test method ................................................................................................................................... 13 4.1.2 Test results .................................................................................................................................... 14 4.2 Radiated emissions (Field strength of fundamental and spurious emissions) ....................................... 16 4.2.1 Test method ................................................................................................................................... 16 4.2.2 Test results preliminary measurement 9 kHz to 30 MHz............................................................... 22 4.2.3 Test results final measurement 9 kHz to 30 MHz .......................................................................... 23 4.2.4 Test results final measurement 30 MHz to 1 GHz ......................................................................... 24 4.2.5 Test results final measurement above 1 GHz ............................................................................... 26 4.3 99 % bandwidth ...................................................................................................................................... 28 4.3.1 Test method ................................................................................................................................... 28 4.3.2 Test results .................................................................................................................................... 29 4.4 The 20 dB bandwidth ............................................................................................................................. 30 4.4.1 Test method ................................................................................................................................... 30 4.4.2 Test results .......................................................................................................…
Text truncated - open the document above for the full version.
ANNEX A TEST SETUP PHOTOS Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 1 of 6 AC Mains conducted emissions setup for EUT1 with PA 1 ANNEX A TEST SETUP PHOTOS Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 2 of 6 AC Mains conducted emissions setup for EUT2 with PA2 ANNEX A TEST SETUP PHOTOS Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 3 of 6 Test setup 9kHz to 30 MHz ANNEX A TEST SETUP PHOTOS Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 4 of 6 Test setup 30 MHz to 1 GHz ANNEX A TEST SETUP PHOTOS Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 5 of 6 Test setup 1 – 4 GHz ANNEX A TEST SETUP PHOTOS Examiner:Mohamed Yassine KHALEKReport Number: F221482E1 Date of issue: 28.11.2022Order Number: 22-111482page 6 of 6 Test setup 4 – 10 GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.875 MHz - 902.875 MHz | - |
AL-447 EnoSense PM VOC
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterAL-435 EnoSense Temp/RH
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterAL-439 EnoSense CO2
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
EnoPuck Basic
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver