2AZWK021SRobotic Vacuum Cleaner with 802.11b/g/n

Shenzhen Segoo Robot Co., Ltd.
Robotic Vacuum Cleaner with 802.11b/g/n - FCC ID 2AZWK021S - Shenzhen Segoo Robot Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 08, 2021
Application Purpose
Original Equipment
Date of Application
Jul 07, 2021
Equipment Note
Robotic Vacuum Cleaner with 802.11b/g/n
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Segoo Robot Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 SEGOO Rotopus S1 2 SEGOO Rotopus S1 3 SEGOO Rotopus S1 4 SEGOO Rotopus S1 5 SEGOO Rotopus S1 6 SEGOO Rotopus S1

External Photos

Details of: Overall view Details of: Overall view Details of: Top view Details of: Bottom view Details of: Side view Details of: Side view Details of: Accessories view (Adapter) Details of: Accessories view (Adapter) Details of: Accessories (Charging dock) Details of: Accessories (Charging dock) Details of: Accessories (Dust box) Details of: Accessories (Dust box)

ID Label/Location Info

Label Drawing Label Location

Internal Photos

Details of: Internal view Details of: Internal view WIFI ANTENNA Details of: Internal view Details of: Main PCB view Details of: Main PCB view Details of: Wi-Fi module Details of: Control PCB view Details of: Control PCB view Details of: Sensitive switch Details of: Sensitive switch Details of: PCB view for Sensitive switch Details of: Infrared sensor Details of: Rang sensor Details of: PCB view for rang sensor Details of: PCB view for rang sensor Details of: Infrared sensor Details of: Laser module Details of: Laser module Details of: UV PCB view Details of: UV PCB view Details of: Loudspeaker Details of: Rotary brush motor Details of: Suction motor Details of: Wheel drive Details of: Wheel drive motor Details of: Rolling brush motor Details of: Li-ion battery Details of: Internal view for Charging dock Details of: PCB view for Charging dock Details of: PCB view for Charging dock

RF Exposure Info

Report No: 68.910.21.0016.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 MPE Calculation Applicant: Shenzhen Segoo Robot Co., Ltd. Address: 1901, IMT Building, No.1 Gaoxin South 7th Road, Nanshan District, 518000 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Product: Robotic Vacuum Cleaner FCC ID: 2AZWK021S Model No.: SEGOO S1 Reference RF report # 68.910.21.0016.01 According to subpart 15.247(i)and subpart §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm2) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1,500 / / f/1500 30 1,500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. Calculated Formulary: Predication of MPE limit at a given distance S = PG/4πR² = power density (in appropriate units, e.g. mW/cm2); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Report No: 68.910.21.0016.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Calculated Data: Maximum peak output power at antenna input terminal (dBm): 15.9 Maximum peak output power at antenna input terminal (mW): 38.91 Prediction distance (cm): 20 Antenna Gain, typical (dBi): 2.0 Maximum Antenna Gain (numeric): 1.58 The worst case is power density at predication frequency at 20 cm (mW/cm2): 0.0123 MPE limit for general population exposure at prediction frequency (mW/cm2): 1.0 0.0123 (mW/cm2) < 1 (mW/cm2) Result: Compliant TUV SUD China, Shenzhen Branch Reviewed by: Prepared By: Dawi Xu / EMC Project Manager Myron Yu / EMC Project Engineer Date: 2021-06-03 Date: 2021-06-03

Test Report

Report Number: 68.910.21.0016.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 75 FCC - TEST REPORT Report Number:68.910.21.0016.01Date of Issue:July 8, 2021 Model:SEGOO S1 Product Type:Robotic Vacuum Cleaner Applicant:Shenzhen SegooRobot Co., Ltd. Address:1901, IMT Building, No.1 Gaoxin South 7th Road, Nanshan District, 518000 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Production Facility:Shenzhen Segoo Robot Co., Ltd. Address:1901, IMT Building, No.1 Gaoxin South 7th Road, Nanshan District, 518000 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Test Result:nPositiveoNegative Total pages including Appendices:75 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. Report Number: 68.910.21.0016.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 75 1 Table of Contents 1Table of Contents ............................................................................................................................................ 2 2Details about the Test Laboratory .................................................................................................................... 3 3Description of the Equipment under Test ......................................................................................................... 4 4Summary of Test Standards ............................................................................................................................ 5 5Summary of Test Results ................................................................................................................................ 6 6General Remarks ............................................................................................................................................ 7 7Test Setups ..................................................................................................................................................... 8 8Systems test configuration ............................................................................................................................... 9 9Technical Requirement .................................................................................................................................. 10 9.1Conducted Emission ............................................................................................................................. 10 9.2Conducted Peak output power .............................................................................................................. 13 9.36dB and 99% bandwidth ....................................................................................................................... 15 9.4Power spectral density .......................................................................................................................... 24 9.5Spurious RF conducted emissions ........................................................................................................ 29 9.6Band edge ............................................................................................................................................ 42 9.7Spurious radiated emissions for transmitter ........................................................................................... 46 10Test Equipment List .................................................................................................................................. 74 11System Measurement Uncertainty............................................................................................................. 75 Report Number: 68.910.21.0016.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 75 2 Details about the Test Laboratory Detailsabout the Test Laboratory Test Site 1 Company name:TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China FCC Registration Number: 514049 ISED#:10320A CAB identifier:CN0077 Telephone:86 755 8828 6998 Fax:86 755 8828 5299 Report Number: 68.910.21.0016.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certificati…

Text truncated - open the document above for the full version.

Test Setup Photos

Test setup of: Conducted Emission Test setup of: Spurious Radiated Emissions (Below 1 GHz) Test setup of: Spurious Radiated Emissions (1-18 GHz) Test setup of: Spurious Radiated Emissions (Above 18 GHz)

Contact Information

Applicant

Haitao Liu
[email protected]+8613028825015Fax: 076982933203

Test Firm

TUV SUD Cert & Testing (China) Co., Ltd.Harry Zhou
[email protected]86 755 3332 3281

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz38.90 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons to satisfy the requirements of 2.1091. End-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This device operates in 20 MHz and 40 MHz BW modes.