Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TimelyHandSOSButtonUsermanual TimelyHandSOSButtonisapersonalemergencydevicewhichtogetherwiththeTimelyhand apponsmartphonescreatesanemergencyalarmsystemusingbluetoothtechnology. TimelyHandSOSButtoncanonlyworkwithTimelyhandapp;itcannotbeusedasan independentdevice. Usermanual Topoweronthedevicepressthebuttonfor3s.Thedevicewillpoweronandwillstartsending iBeaconsignals.TheTimelyHandappshouldbeusedtoconnecttothedevicefurtherstepswill beprovidedontheapp. Generalfeatures MainChipNordicnRF52840 BluetoothBluetooth5.3 RangeUpto150meters(intheopenareaandnoobstacles) Dimension48.9mmx41.7mmx12mm(Mainbody) MaterialABS+PC&TPU WaterproofIP67 ColorBlack InstallationNeckpendant,wristband ButtonMechanicalbutton LEDREDandGREENLED Operatingtemperature-20°C/+60°C PowersupplyCR2032LithiumCoinCellBattery220mAh CertificationUSAFCCID:2BACY-THSB1 Mechanicaldrawings FCCSTATEMENT 1.ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions: (1)Thisdevicemaynotcauseharmfulinterference. (2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause undesiredoperation. 2.Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliance could voidtheuser'sauthoritytooperatetheequipment. NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation. Thisequipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnotinstalledand usedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio communications. However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthis equipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbe determinedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreofthefollowingmeasures: Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. RFwarningstatement: ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirements.Thedevicecanbe used inportableexposureconditionswithoutrestriction.
UAB Kilo grupe Covered Equipment Certification Attestation Letter 3/31/2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2BACY-THSB1 Spintly Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Spintly Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Arnas Petravicius Title: Product lead Company Name: UAB Kilo grupe Date: 3/31/2023
UAB Kilo grupe * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter April 7, 2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2BACY-THSB1 Per section 2.911(d)(7) of the FCC rules, UAB Kilo grupe certifies that the equipment for which authorization is sought is designated to the following U.S. Designated agent* for service of process: Company Name: #" Physical U.S. Company Address: " # $ Agent name: # Agent Email Address: #" #"! FRN: The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Designated Agent Signed: (Required, if different to Applicant): Signed: Signed: Printed name: !" $#! Printed name: # Title: Product lead Title: CEO Company Name: UAB Kilo grupe Company Name: #" Date: 2023-3-31 Date: March 31, 2023
UAB Kilo grupe 4/7/2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: 2BACY-THSB1 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request confidential treatment of information accompanying this application as outlined below: PERMANENT LONG-TERM CONFIDENTIALITY: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation The above information contains trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Sincerely, Signed: Printed name:Arnas Petravicius Title: Product lead
UAB Kilo grupe 4/11/2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint UAB Kilo grupe Antakalnio 17 Building 8 LT-10312 Vilnius, Lithuania to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Arnas Petravicius
FCC ID: 2BACY-THSB1 Page 1/4 External photo FCC ID: 2BACY-THSB1 Page 2/4 FCC ID: 2BACY-THSB1 Page 3/4 FCC ID: 2BACY-THSB1 Page 4/4 --END---
Label Location
FCC ID: 2BACY-THSB1 Page 1/3 Internal photo FCC ID: 2BACY-THSB1 Page 2/3 2402-2480MHz BT Antenna FCC ID: 2BACY-THSB1 Page 3/3 ---END---
Page 1 of 2 Address: No.11, WuSong Road, Tel: 86-769-22607797 DongchengDistrict,Dongguan, Fax: 86-769-22607907 GuangdongProvince,China523117 http://www.cpcteam.com RF EXPOSURE EVALUATION EUT Specification EUT Timely Hand SOS Button Model Number THSB1 FCC ID 2BACY-THSB1 Antenna gain (Max) -0.47dBi Operation Frequency 2402-2480MHz Input Rating DC 3V Standard 47 CFR Part 1.1307 47 CFR Part 1.1310 KDB447498D01 General RF Exposure Guidance v06 Modulation BLE Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] • [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation17 • The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion According to KDB447498D01 General RF Exposure Guidance v06 Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 90187-23-72-23-PP002 Page 2 of 2 Address: No.11, WuSong Road, Tel: 86-769-22607797 DongchengDistrict,Dongguan, Fax: 86-769-22607907 GuangdongProvince,China523117 http://www.cpcteam.com Calculated Result and Limit Operation Mode: GFSK, 8DPSK Channel Maximum Peak Conducted Output Power (dBm) Tune up tolerance (dBm) Maximum tune-up Power Calculated value Exclusion threshold (dBm) (mW) GFSK -Lowest (2402MHz) 7.60 7±1 8 6.30 1.95 3.0 GFSK -Middle (2440MHz) 7.17 7±1 8 6.30 1.97 GFSK -Highest (2480MHz) 7.09 7±1 8 6.30 1.98 Conclusion: the calculated value ≤3.0, SAR is exempted. Remark: The Max Conducted Peak Output Power data refer to report Report No.: 90187-23-72-23-PP001.
Page 1 of 30 Address: No. 11, Wu Song Road, Tel: 86-769-22607797 DongchengDistrict,Dongguan, Fax: 86-769-22607907 Guangdong Province, China 523117 http://www.cpcteam.com TEST REPORT Report Number. ........................ : 90187-23-72-23-PP001 Date of issue ............................ : 2023.03.31 Tested by (+signature) ............ : Duke Chen Approved by (+signature) ....... : Jason Gao Testing Laboratory name ........ : SLG-CPC Testlaboratory Co., Ltd. Address .................................... : No. 11, Wu Song Road, Dongcheng District, Dongguan, Guangdong Province, China 523117 Applicant’s name ..................... : UAB Kilo grupe Address .................................... : Antakalnio 17 Building 8 LT-10312 Vilnius, Lithuania Manufacturer’s name ............. : MOKO TECHNOLOGY Ltd Address .................................... : Factory 201, 107 Pinshun Rd Guixiang community, Guanlan Street, Longhua, Shenzhen, China 518110 Factory’s name ....................... : MOKO TECHNOLOGY Ltd Address .................................... : Factory 201, 107 Pinshun Rd Guixiang community, Guanlan Street, Longhua, Shenzhen, China 518110 Standard(s) ............................... : FCC 47 CFR Part 15, Subpart C Test item description ............... : THSB1 EUT ............................................ : Timely Hand SOS Button Model/Type reference .............. : THSB1 FCC ID ....................................... : 2BACY-THSB1 Date of receipt of test item ..... : 2023.03.22 Date (s) of performance of test: 2023.03.22 - 2023.03.30 Summary of Test Results ........ : Pass The Summary of Test Results based on a technical opinion belongs to the standard(s). General disclaimer: This report shall not be reproduced except in full, without the written approval of SLG-CPC Testlaboratory Co., Ltd. The test results in the report only apply to the tested sample. 90187-23-72-23-PP001 Page 2 of 30 Address: No. 11, Wu Song Road, Tel: 86-769-22607797 DongchengDistrict,Dongguan, Fax: 86-769-22607907 Guangdong Province, China 523117 http://www.cpcteam.com Table of Contents 1 EUT TECHNICAL DESCRIPTION ............................................................................................. 4 2 SUMMARY OF TEST RESULT ................................................................................................. 5 3 TEST METHODOLOGY ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF APPLIED STANDARDS .................................................... 6 3.2 MEASUREMENT EQUIPMENT USED .............................................................................. 6 3.3 DESCRIPTION OF TEST MODES ..................................................................................... 7 4 FACILITIES AND ACCREDITATIONS ....................................................................................... 8 4.1 FACILITIES ........................................................................................................................ 8 4.2 LABORATORY ACCREDITATIONS AND LISTINGS .......................................................... 8 5 TEST SYSTEM UNCERTAINTY ............................................................................................... 9 6 SETUP OF EQUIPMENT UNDER TEST ................................................................................ 10 6.1 RADIO FREQUENCY TEST SETUP 1 ............................................................................ 10 6.2 RADIO FREQUENCY TEST SETUP 2 ............................................................................ 10 7 TEST REQUIREMENTS ......................................................................................................... 12 7.1 DTS 6DB BANDWIDTH ................................................................................................... 12 7.2 MAXIMUM PEAK CONDUCTED OUTPUT POWER ....................................................... 15 7.3 MAXIMUM POWER SPECTRAL DENSITY ..................................................................... 17 7.4 RADIATED SPURIOUS EMISSION ................................................................................. 20 7.5 ANTENNA APPLICATION ................................................................................................ 30 90187-23-72-23-PP001 Page 3 of 30 Address: No. 11, Wu Song Road, Tel: 86-769-22607797 DongchengDistrict,Dongguan, Fax: 86-769-22607907 Guangdong Province, China 523117 http://www.cpcteam.com Modified Information Version Report No. Revision Data Summary Ver.1.0 90187-23-72-23-PP001 2023-03-31 Original Version 90187-23-72-23-PP001 Page 4 of 30 Address: No. 11, Wu Song Road, Tel: 86-769-22607797 DongchengDistrict,Dongguan, Fax: 86-769-22607907 Guangdong Province, China 523117 http://www.cpcteam.com 1 EUT TECHNICAL DESCRIPTION Product: Timely Hand SOS Button Model Number: THSB1 Power supply: : DC 3V :Adapter information Modulation: BLE Frequency Range: 2402MHz~2480MHz Number of Channels: 40channels Channel Space: 1MHz Antenna Gain: -0.47dBi Antenna: PCB Antenna Temperature Range: 0°C ~ +45°C Note: for more details, please refer to the User’s manual of the EUT. 90187-23-72-23-PP001 Page 5 of 30 Address: No. 11, Wu Song Road, Tel: 86-769-22607797 DongchengDistrict,Dongguan, Fax: 86-769-22607907 Guangdong Province, China 523117 http://www.cpcteam.com 2 SUMMARY OF TEST RESULT FCC Part Clause Test Parameter Verdict Remark 15.247(a)(2) DTS (6dB) Bandwidth PASS 15.247(b)(3) Maximum Peak Conducted Output Power PASS 15.247(e) Maximum Power Spectral Density Level PASS 15.247(d) Unwanted Emission Into Non-Restricted Frequency Bands PASS 15.247(d) 15.209 Radiated Spurious Emission PASS 15.207 Conducted Emission Test N/A 15.247(b) Antenna Application PASS NOTE1: N/A (Not Applicable) NOTE2: According to FCC OET KDB 558074, the report use radiated measurements in the restricted frequency bands. In addition, the radiated test is also performed to ensure the …
Text truncated - open the document above for the full version.
Confidential Data Project Name: W6 Author: 杨永成 Update: 2021-05-22 Antenna Test Report Index: 1.Overview 2.Revision History 3.Test Item &Equipment 4.Matching Circuit 5.SParameter Test 6.Active Test 7.Conducted EmissionTest 8.Environmental Processing Confidential Data 项目概况 OverView CUSTOMER NAME 华创恒达 PROJECT NAMEW6 ItemsDetails •FREQUENCY2400MHz-2500MHz •Manufacturer’s •M/N: •Address •SENSITIVE ELEMENTS •ANTENNA TYPE •PCB •OTHERS MOKO TECHNOLOGY Ltd W6 Factory 201, 107 Pinshun Rd Guixiang community, Guanlan Street, Longhua, Shenzhen, China 518110 Confidential Data 日期(Date) 版本 (Revision) 负责人(Author)更改原因(Description of changes) 202010520 A 杨永成天线无源测试报告 20201022 B 杨永成新主板 历史报告记录 Revision History Confidential Data ListTest ItemEquipment 1.SParameterVSWR, Return LossAgilent VNA 2.Active Test TRP, TISAgilent 8960 RayZone1800 3.Passive TestGain, Efficiency, PatternAgilent E5071C Test Item & Equipment Confidential Data 2021/6/22 Matching Circuit Antenna RF Module E3E1 E2 ElementValue E1(0402)NC E2(0402)0Ω E3(0402)NC Confidential Data 2021/6/22 天线 Confidential Data VSWR Confidential Data PASSIVE TEST(天线效率及增益) Freq (Mhz) Gain (dB) Effi (%) 2400-1.2428.75 2410-1.1531.57 2420-1.2531.72 2430-1.1431.83 2440-1.1131.47 2450-1.1631.21 2460-1.1632.08 2470-0.8833.20 2480-0.5233.11 2490-0.4732.86 2500-0.5933.15 Confidential Data 3D Antenna Radiation Pattern(2450MHz) Confidential Data 2D Antenna Radiation Pattern(2450MHz )
FCC ID: 2BACY-THSB1 Test photo Radiated emission FCC ID: 2BACY-THSB1
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 5.75 mW |