Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Housefarm User Manual INTRODUCTION Read these instructions carefully before using the appliance. Failure to follow these instructions may result in injuries and equipment damage. The manufacturer is not liable for damages resulting from failure to follow these instructions for use. - This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved - Children shall not play with the appliance - Cleaning and user maintenance shall not be made by children without supervision - If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard ①Temperature Current temperature ② Humidity Current Humidity ③ Water tank the amount of water in the water tank ④ Air quality Current air quality ⑤ pH Indicates the ph value. ⑥ Cultivation mode Choose from standard, leaf and herbs. ⑦ LED time change Change the set time in the cultivation mode to the desired time. ⑧ LED Power A button to temporarily turn on/off the LED power. ⑨ Settings This button is for wireless Internet connection. Basically, the method of use is the same as that of a smartphone. Cleaning Prior to the Next Planting Once the crop is harvested, clean up the hydroponics unit to start another planting. To clean up the hydroponics system: 1. Turn off the power and unplug the cord from the wall outlet. 2. Clean up the sponge for reuse (optional) or purchase new sponge. 3. Drain water from the system: • Plant Producer Hydroponics System: a. Remove the tray covers from all two shelves. b. Beginning with the top tray and working down, use a towel to push the water into the drain. c. Disconnect the water hose and remove the tray. d. Remove the water in the tray. 4. Clean the tank(s) and tray covers with warm soapy water from a bucket. Do not pour soap/bleach directly into the reservoir. Bleach can be used to clean the hydroponics system, but it is suggested to use less than a ¼ capful of bleach for every 1-2 gallons of water. If bleach is used, wait an additional 24 hours before filling the tank with water. 5. Rinse thoroughly to remove the soap and bleach (if used). 6. Remove all visible green algae that may have accumulated from the previous harvest. 7. Dry or let air dry before adding new water. 8. Once clean and dry, new water can be added. The recommendation is to let water sit/circulate for 24 hours before adding any plant life to the hydroponics system. FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is con-nected. • Consult the dealer or an experienced radio/TV technician for help. Caution Modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Dreamfarm Solution Co., Ltd. Covered Equipment Certification Attestation Letter 4/19/2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2BAD5-HFMODEL7 Dreamfarm Solution Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Dreamfarm Solution Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Jihoon Jeong Title: Leader Company Name: Dreamfarm Solution Co., Ltd. Date: 4/19/2023
[Dreamfarm Solution Co., Ltd.] [Office1, 7F Junwave sunworld clinic-dong, 444, Dongbaekjukjeon-daero, Giheung-gu] [Yongin-si, Gyeonggi-do] [South Korea] Date: [April 19, 2023] Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: [2BAD5-HFMODEL7] US Agent – Attestation Statement / Part 2.911(d)(7) [Dreamfarm Solution Co., Ltd.] certifies, that as of [April 19, 2023], we have designated FCC US Agent, LLC to accept service of process on our behalf for FCC ID: [2BAD5-HFMODEL7]. [Dreamfarm Solution Co., Ltd.], accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. FCC US Agent, LLC, accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of [Dreamfarm Solution Co., Ltd.] for FCC ID: [2BAD5-HFMODEL7]. Designated Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Company: [Dreamfarm Solution Co., Ltd.] Designated Agent: FCC US Agent, LLC Company Representative: [Jihoon Jeong] Designated Agent Representative: Tim Payne Signature: Signature:
Dreamfarm Solution Co., Ltd. 4/19/2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint ONETECH Corp. / 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi- do, 12735, Korea., to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Jihoon Jeong
Dreamfarm Solution Co., Ltd. April 19, 2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: 2BAD5-HFMODEL7 Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☒ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Jihoon Jeong Title: Leader Company Name: Dreamfarm Solution Co., Ltd.
Page 1 of 6 Page 2 of 6 Page 3 of 6 Page 4 of 6 Page 5 of 6 Page 6 of 6
Page 1 of 1 IDENTIFICATION LABEL: PROPOSED FCC ID LABEL The FCC ID shall be permanently affixed in the rear side of the equipment
Page 1 of 11 Page 2 of 11 Page 3 of 11 Page 4 of 11 Page 5 of 11 Page 6 of 11 Page 7 of 11 Page 8 of 11 Page 9 of 11 Page 10 of 11 Page 11 of 11
Page 1 of 7 Report No.: OT-234-RWD-020 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMF TEST REPORT Test Report No. : OT-234-RWD-020 Reception No. : 2301000193 Applicant : Dreamfarm Solution Co., Ltd. Address : Office 1, 7F Junwave sunworld clinic-dong, 444, Dongbaekjukjeon-daero, Giheung- gu, Yongin-si, Gyeonggi-do, Republic of Korea Manufacturer : Dreamfarm Solution Co., Ltd. Address : Office 1, 7F Junwave sunworld clinic-dong, 444, Dongbaekjukjeon-daero, Giheung- gu, Yongin-si, Gyeonggi-do, Republic of Korea Type of Equipment : Housefarm FCC ID. : 2BAD5-HFMODEL7 Model Name : HF22F Multiple Model Name : N/A Serial number : N/A Total page of Report : 7 pages (including this page) Date of Incoming : December 06, 2022 Date of issue : April 17, 2023 SUMMARY The equipment complies with the regulation; FCC CFR 47 PART 1.1310 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. This report is not correlated with the "KS Q ISO/IEC 17025 and KOLAS accreditation" of Korean Laboratory Accreditation Scheme. Tested by Yun-Bok, Wi / Prj. Engineer ONETECH Corp. Reviewed by Tae-Ho, Kim / Chief Engineer ONETECH Corp. Approved by Jae-Ho, Lee / Chief Engineer ONETECH Corp. Page 2 of 7 Report No.: OT-234-RWD-020 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 4 2. GENERAL INFORMATION ............................................................................................................................................ 5 2.1 PRODUCT DESCRIPTION ................................................................................................................................................. 5 2.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 5 3. EUT MODIFICATIONS .................................................................................................................................................... 5 4. MAXIMUM PERMISSIBLE EXPOSURE ...................................................................................................................... 6 4.1 RF EXPOSURE CALCULATION ....................................................................................................................................... 6 4.2 EUT DESCRIPTION ......................................................................................................................................................... 6 4.3 CALCULATED MPE SAFE DISTANCE............................................................................................................................. 7 Page 3 of 7 Report No.: OT-234-RWD-020 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) Revision History Rev. No. Issue Report No. Issued Date Revisions Section Affected 0 OT-234-RWD-020 April 17, 2023 Initial Release All Page 4 of 7 Report No.: OT-234-RWD-020 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 1. VERIFICATION OF COMPLIANCE Applicant : Dreamfarm Solution Co., Ltd. Address : Office 1, 7F Junwave sunworld clinic-dong, 444, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do, Republic of Korea Contact Person : Jihoon, Jeong / Leader Telephone No. : +82-10-8798-4252 FCC ID : 2BAD5-HFMODEL7 Model Name : HF22F Brand Name : - Serial Number : N/A Date : April 17, 2023 EQUIPMENT CLASS DTS – DIGITAL TRNSMISSION SYSTEM E.U.T. DESCRIPTION Housefarm THIS REPORT CONCERNS Original Grant MEASUREMENT PROCEDURES KDB 447498 D01 General RF Exposure Guidance v06 TYPE OF EQUIPMENT TESTED Pre-Production KIND OF EQUIPMENT AUTHORIZATION REQUESTED Certification Modifications on the Equipment to Achieve Compliance None -. The above equipment was tested by ONETECH Corp. for compliance with the requirement set forth in the FCC Rules and Regulations. This said equipment in the configuration described in this report, shows the maximum emission levels emanating from equipment are within the compliance requirements. Page 5 of 7 Report No.: OT-234-RWD-020 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 2. GENERAL INFORMATION 2.1 Product Description The Dreamfarm Solution Co., Ltd., Model HF22F (referred to as the EUT in this report) is a Housefarm. The product specification described herein was obtained from product data sheet or user’s manual. DEVICE TYPE Housefarm OPERATING FREQUENCY 2 412 MHz ~ 2 462 MHz (802.11b/g/n(HT20)) MODULATION TYPE 802.11b: DSSS Modulation (DBPSK/DQPSK/CCK) 802.11g/n(HT20): OFDM Modulation (BPSK/QPSK/16QAM/64QAM) RF OUTPUT POWER 17.04 dBm (802.11b) 14.91 dBm (802.11g) 15.66 dBm (802.11n_HT20) ANTENNA TYPE PCB Antenna ANTENNA GAIN 0.49 dBi List of each Osc. or crystal Freq.(Freq. >= 1 MHz) 26 MHz RATED SUPPLY VOLTAGE DC 12.0 V 2.2 Alternative type(s)/model(s); also covered by this test report. -. None 3. EUT …
Text truncated - open the document above for the full version.
Page 1 of 31 Report No.: OT-234-RWD-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) RADIO PERFORMANCE TEST REPORT Test Report No. : OT-234-RWD-019 Reception No. : 2301000193 Applicant : Dreamfarm Solution Co., Ltd. Address : Office 1, 7F Junwave sunworld clinic-dong, 444, Dongbaekjukjeon-daero, Giheung- gu, Yongin-si, Gyeonggi-do, Republic of Korea Manufacturer : Dreamfarm Solution Co., Ltd. Address : Office 1, 7F Junwave sunworld clinic-dong, 444, Dongbaekjukjeon-daero, Giheung- gu, Yongin-si, Gyeonggi-do, Republic of Korea Type of Equipment : Housefarm FCC ID. : 2BAD5-HFMODEL7 Model Name : HF22F Multiple Model Name : N/A Serial number : N/A Total page of Report : 31 pages (including this page) Date of Incoming : December 06, 2022 Date of issue : April 17, 2023 SUMMARY The equipment complies with the regulation; FCC PART 15 SUBPART C Section 15.247 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. This report is not correlated with the "KS Q ISO/IEC 17025 and KOLAS accreditation" of Korean Laboratory Accreditation Scheme. Tested by Yun-Bok, Wi / Prj. Engineer ONETECH Corp. Reviewed by Tae-Ho, Kim / Chief Engineer ONETECH Corp. Approved by Jae-Ho, Lee / Chief Engineer ONETECH Corp. Page 2 of 31 Report No.: OT-234-RWD-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 5 2. TEST SUMMARY .............................................................................................................................................................. 6 2.1 TEST ITEMS AND RESULTS ............................................................................................................................................. 6 2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS ........................................................................................... 6 2.3 RELATED SUBMITTAL(S) / GRANT(S) ............................................................................................................................ 6 2.4 PURPOSE OF THE TEST ................................................................................................................................................... 6 2.5 TEST METHODOLOGY .................................................................................................................................................... 6 2.6 TEST FACILITY ............................................................................................................................................................... 6 3. GENERAL INFORMATION ............................................................................................................................................ 7 3.1 PRODUCT DESCRIPTION ................................................................................................................................................. 7 3.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 7 4. EUT MODIFICATIONS .................................................................................................................................................... 7 5. SYSTEM TEST CONFIGURATION ............................................................................................................................... 8 5.1 JUSTIFICATION ............................................................................................................................................................... 8 5.2 PERIPHERAL EQUIPMENT .............................................................................................................................................. 8 5.3 MODE OF OPERATION DURING THE TEST ...................................................................................................................... 8 5.4 CONFIGURATION OF TEST SYSTEM ............................................................................................................................. 10 5.5 ANTENNA REQUIREMENT ............................................................................................................................................ 10 6. PRELIMINARY TEST .................................................................................................................................................... 10 6.1 AC POWER LINE CONDUCTED EMISSIONS TESTS ....................................................................................................... 10 6.2 GENERAL RADIATED EMISSIONS TESTS ..................................................................................................................... 10 7. MIMIMUM 6 DB BANDWIDTH ................................................................................................................................... 11 7.1 OPERATING ENVIRONMENT ......................................................................................................................................... 11 7.2 TEST SET-UP ................................................................................................................................................................. 11 7.3 TEST DATE ................................................................................................................................................................... 1…
Text truncated - open the document above for the full version.
Page 1 of 2 - CONDUCTED EMISSION TEST Page 2 of 2 - RADIATED EMISSION TEST
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 50.59 mW |