FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dongguan Shidu Technology Co., Ltd/
  3. 2BADLSD-472

2BADLSD-472Hera Lick

Dongguan Shidu Technology Co., Ltd
Hera Lick - FCC ID 2BADLSD-472 - Dongguan Shidu Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 04, 2025
Application Purpose
Original Equipment
Equipment Note
Hera Lick
Frequency Range
2402.00000000 - 2480.00000000
Company
Dongguan Shidu Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Warning 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC RF Radiation Exposure Statement: 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. 3. This equipment should be installed and operated with minimum distance 5mm between the radiator and your body.

Attestation Statements

DongguanShiduTechnologyCo.,Ltd. AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:Dec.1,25 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2BADLSD-472 DongguanShiduTechnologyCo.,Ltd.(“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002of referencechapter,asanentityproducing“covered”communicationequipment.Theequipmentfor whichauthorizationissoughtisnot“covered”telecommunicationsequipmentandvideosurveillance equipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthatprohibitedfrom receivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:YongXiong Title:Manager Address:Room201,No.97,YanheWestRoad,ChangpingTown,DongguanCity,China Tel:8618098289399 Email:[email protected]

Attestation Statements

DongguanShiduTechnologyCo.,Ltd. 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Dec.1,25 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:[2BADLSD-472] ProductName:[HeraLick] Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered" softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:YongXiong Title:Manager Address:Room201,No.97,YanheWestRoad,ChangpingTown,DongguanCity,China Tel:8618098289399 Email:[email protected] DongguanShiduTechnologyCo.,Ltd. 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) Seeattached“SBoM“ Note:TheSBoMcontentislimited tothescopeofcoveredlist software(e.g.antivirusand cybersecuritysoftware). ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck

Attestation Statements

DongguanShiduTechnologyCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 [2025-12-01] U.S.AgentDesignation [DongguanShiduTechnologyCo.,Ltd.]acknowledgestheirconsentforthefollowingcontactlocatedinthe UnitedStatestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCC ID:2BADLSD-472): NameandcompanyofU.S.agent:[GLOCERTSTECHNOLOGYINC] PhysicalU.S.addressofagent:[19784SUNKISSEDRIDGEDR,RIVERSIDE,CA92507] FRNofU.S.agent:[0036339737] EmailaddressofU.S.agent:[[email protected]] TelephoneofU.S.agent:(626)588-8039 [GLOCERTSTECHNOLOGYINC]acknowledgestheirobligationtoacceptserviceofprocessonbehalfof [DongguanShiduTechnologyCo.,Ltd.]. [DongguanShiduTechnologyCo.,Ltd.]withtheFRN[0033453069]acceptsitsobligationtomaintainanagent forserviceofprocessintheUnitedStatesfornolessthan1yearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Sincerely, SignatureSignature [YongXiong][HuiyingFan] [Manager][Director] [DongguanShiduTechnologyCo.,Ltd.][GLOCERTSTECHNOLOGYINC] Tel:8618098289399 Email:[email protected]

Cover Letter(s)

DongguanShiduTechnologyCo.,Ltd. (December1,2025) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2BADLSD-472 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: BlockDiagram  Schematics OperationalDescription Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. Sincerely, (Signature) PrintedName:YongXiong Title:Manager Address:Room201,No.97,YanheWestRoad,ChangpingTown,DongguanCity,China Tel:8618098289399 Email:[email protected]

Cover Letter(s)

DongguanShiduTechnologyCo.,Ltd. (December1,2025) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2BADLSD-472 I,theundersigned,herebyauthorize( BTFTestingLab(Shenzhen)Co.,Ltd. )toactonour behalfinallmattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(BTFTestingLab(Shenzhen)Co.,Ltd.)shallhavethesameeffectas ourownandIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsof certification,asspecifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith (DongguanShiduTechnologyCo.,Ltd.). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, (Signature) (FullnameofcontactpersonlistedonFCC’swebsite)YongXiong (Title)Manager Tel:8618098289399 Email:[email protected]

External Photos

FCCID:2BADLSD-472ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page1of4 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangd ong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 AppendixIIExternalPhotos FCCID:2BADLSD-472ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page2of4 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangd ong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 FCCID:2BADLSD-472ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page3of4 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangd ong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 FCCID:2BADLSD-472ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page4of4 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangd ong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00

ID Label/Location Info

Label&Location

Internal Photos

FCCID:2BADLSD-472ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page1of3 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangd ong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 AppendixIIIInternalPhotos FCCID:2BADLSD-472ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page2of3 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangd ong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 FCCID:2BADLSD-472ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page3of3 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangd ong,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00

RF Exposure Info

TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page1of9 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 HealthTestReport For Applicantname: DongguanShiduTechnologyCo.,Ltd. Address: Room201,No.97,YanheWestRoad,ChangpingTown,Dongguan City,China EUTname: HeraLick Brandname: N/A Modelnumber: SD-472 Seriesmodelnumber: N/A FCCID: 2BADLSD-472 IssuedBy Companyname: BTFTestingLab(Shenzhen)Co.,Ltd. Address: Plant101,201and301,Building1,Block2,TantouIndustrialPark, TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Reportnumber: BTF251112R00602 Teststandards: 47CFRPart2SubpartJSection2.1093 Testconclusion: Pass Dateofsamplereceipt: 2025-11-14 Testdate: 2025-11-14to2025-11-20 Dateofissue: 2025-11-29 Preparedby: Approvedby: Chris.Liu/ProjectengineerRyan.CJ/EMCmanager Note:Allthetestresultsinthisreportonlyrelatedtothetestingsamples.Whichcanbeduplicatedcompletelyforthelegalusewithapprovalof applicant;itshallnotbereproducedexceptinfullwithoutthewrittenapprovalofBTFTestingLab(Shenzhen)Co.,Ltd.,Alltheobjectionsshouldbe raisedwithinthirtydaysfromthedateofissue.Tovalidatethereport,youcancontactus. ReportNumber:BTF251112R00602 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page2of9 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 RevisionHistory VersionIssuedateRevisionscontent R_V02025-11-29Original ReportNumber:BTF251112R00602 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page3of9 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 TableofContents 1Introduction...............................................................................................................................................................4 1.1LaboratoryLocation..........................................................................................................................................4 1.2LaboratoryFacility............................................................................................................................................4 1.3Announcement..................................................................................................................................................4 2ProductInformation..................................................................................................................................................5 2.1ApplicationInformation.....................................................................................................................................5 2.2ManufacturerInformation.................................................................................................................................5 2.3FactoryInformation...........................................................................................................................................5 2.4GeneralDescriptionofEquipmentunderTest(EUT)......................................................................................5 2.5TechnicalInformation.......................................................................................................................................5 3RFOutputPower.......................................................................................................................................................6 4AppliedReferenceDocuments................................................................................................................................7 5RFExposureLimit....................................................................................................................................................7 6RFExposureAssessment........................................................................................................................................8 ReportNumber:BTF251112R00602 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page4of9 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 1Introduction 1.1LaboratoryLocation Testlocation:BTFTestingLab(Shenzhen)Co.,Ltd. Address: Plant101,201and301,Building1,Block2,TantouIndustrialPark,Tantou Community,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Description: AllmeasurementfacilitiesusedtocollectthemeasurementdataarelocatedatPlant 101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity, SonggangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Phonenumber:+86-0755-23146130 Faxnumber:+86-0755-23146130 1.2LaboratoryFacility Thetestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: FCC-DesignationNo.:CN1409 BTFTestingLab(Shenzhen)Co.,Ltd.hasbeenaccreditedasatestinglaboratorybyFCC(Federal CommunicationsCommission).ThetestfirmRegistrationNo.is695374. CNAS-RegistrationNo.:CNASL17568 BTFTestingLab(Shenzhen)Co.,Ltd.isaccreditedtoISO/IEC17025:2017GeneralRequirementsfor theCompetenceofTestingandCalibrationlaboratoriesforthecompetenceoftesting.TheRegistration No.isCNASL17568. A2LA-RegistrationNo.:6660.01 BTFTestingLab(Shenzhen)Co.,Ltd.isaccreditedinaccordancewiththerecognizedInternational StandardISO/IEC17025:2017Generalrequirementsforthecompetenceoftestingandcalibration laboratories. 1.3Announcement (1)Thetestreportrefere…

Text truncated - open the document above for the full version.

Test Report

TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page1of32 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-0755-23146130http://www.btf-lab.comVersion:1/00 RFTestReport For Applicantname:DongguanShiduTechnologyCo.,Ltd. Address: Room201,No.97,YanheWestRoad,ChangpingTown,Dongguan City,China EUTname:HeraLick Brandname:N/A Modelnumber:SD-472 Seriesmodelnumber:N/A FCCID:2BADLSD-472 IssuedBy Companyname:BTFTestingLab(Shenzhen)Co.,Ltd. Address: Plant101,201and301,Building1,Block2,TantouIndustrialPark, TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Reportnumber:BTF251112R00601 Teststandards:47CFRPart15.247 Testconclusion:Pass Dateofsamplereceipt:2025-11-14 Testdate:2025-11-14to2025-11-19 Dateofissue:2025-11-29 Testby: Sean.He/Tester Preparedby:Approvedby: Chris.Liu/ProjectengineerRyan.CJ/EMCManager Note:Allthetestresultsinthisreportonlyrelatedtothetestingsamples.Whichcanbeduplicatedcompletelyforthelegalusewithapprovalof applicant;itshallnotbereproducedexceptinfullwithoutthewrittenapprovalofBTFTestingLab(Shenzhen)Co.,Ltd.,Alltheobjectionsshouldbe raisedwithinthirtydaysfromthedateofissue.Tovalidatethereport,youcancontactus. ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page2of32 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-0755-23146130http://www.btf-lab.comVersion:1/00 RevisionHistory VersionIssueDateRevisionsContent R_V02025-11-29Original Note: Oncetherevisionhasbeenmade,thenpreviousversionsreportsareinvalid. ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page3of32 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, Guangdong,China Email:[email protected]:+86-0755-23146130http://www.btf-lab.comVersion:1/00 TableofContents 1Introduction........................................................................................................................................................4 1.1LaboratoryLocation...................................................................................................................................4 1.2LaboratoryFacility......................................................................................................................................4 1.3Announcement...........................................................................................................................................4 2ProductInformation...........................................................................................................................................5 2.1ApplicationInformation..............................................................................................................................5 2.2ManufacturerInformation...........................................................................................................................5 2.3FactoryInformation....................................................................................................................................5 2.4GeneralDescriptionofEquipmentunderTest(EUT)................................................................................5 2.5TechnicalInformation.................................................................................................................................6 3SummaryofTestResults..................................................................................................................................7 3.1TestStandards...........................................................................................................................................7 3.2UncertaintyofTest.....................................................................................................................................7 3.3SummaryofTestResult.............................................................................................................................7 3.4Additionsto,deviations,orexclusionsfromthemethod...........................................................................8 4TestConfiguration..............................................................................................................................................9 4.1TestEquipmentList....................................................................................................................................9 4.2TestAuxiliaryEquipment..........................................................................................................................10 4.3TestModes...............................................................................................................................................10 4.4TestChannelofEUT................................................................................................................................10 4.5Testsoftware............................................................................................................................................11 5EvaluationResults(Evaluation).....................................................................................................................12 5.1Antennarequirement...............................................................................................................................12 6RadioSpectrumMatterTestResults(RF).....................................................................................................12 6.1ConductedEmissionatACpowerline.................................................................................................…

Text truncated - open the document above for the full version.

Test Report

$QWHQQDGHVFULEH $QWHQQDGHVFULEH $QWHQQD SODWH0 RQRSORHDQWHQQD 0DNHQDPHPRGHOQDPH) $QWHQQDJDLQG%L )UHTXHQF\UDQJH * +=   * += &RQQHFWRUW\SHGLUHFW ([WHUQDOYLHZGUDZLQJ 3LFWXUHRIDQWHQQD $QWHQQD5DGLDWLRQ3DWWHUQ 5DGLDWLRQSDWWHUQ#*+= 7RWDO$YHUDJH*DLQGEL  3KL *DLQ  5DGLDWLRQSDWWHUQ#*+= 7RWDO$YHUDJH*DLQGEL  3KL *DLQ  5DGLDWLRQSDWWHUQ#*+= 7RWDO$YHUDJH*DLQGEL  3KL *DLQ 

Test Report

ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page1of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 Appendix-BLE 1.DutyCycle 1.1TestResult 1.1.1Ant1 Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) DutyCycle (%) DutyCycle CorrectionFactor(dB) Max.DC Variation(%) 1MSISO 24022.1432.50085.720.670.03 24402.1432.50085.720.670.03 24802.1432.50085.720.670.03 2MSISO 24021.0912.50143.623.600.02 24401.0902.49943.623.600.03 24801.0902.49943.623.600.03 ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page2of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 1.2TestGraph 1.2.1Ant1 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page3of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page4of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page5of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2.Bandwidth 2.1TestResult 2.1.1OBW Mode TX Type Frequency (MHz) ANT 99%OccupiedBandwidth(MHz) Verdict ResultLimit 1MSISO 240211.037/Pass 244011.033/Pass 248011.032/Pass 2MSISO 240212.043/Pass 244012.040/Pass 248012.031/Pass 2.1.26dBBW Mode TX Type Frequency (MHz) ANT 6dBBandwidth(MHz) Verdict ResultLimit 1MSISO 240210.663>=0.5Pass 244010.666>=0.5Pass 248010.666>=0.5Pass 2MSISO 240211.170>=0.5Pass 244011.163>=0.5Pass 248011.161>=0.5Pass ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page6of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2.2TestGraph 2.2.1OBW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page7of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page8of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page9of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2.2.26dBBW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page10of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page11of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV ReportNumber:BTF251112R00601 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page12of38 BTFTestingLab(Shenzhen)Co.,Ltd. Plant101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,Guangdon g,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 3.MaximumConductedOutputPower 3.1TestResult 3.1.1Power Mode TX Type Frequency (MHz) MaximumPeakConductedOutputPower(dBm) Verdict ANT1Limit 1MSISO 2402-1.68<=30Pass 2440-1.37<=30Pass 2480-1.02<=30Pass 2MSISO 2402-1.66<=30Pass 2440-1.29<=30Pass 2480-0.91<=30Pass Note1:AntennaGain:Ant1:0.00dBi; ReportNumber:BTF251112R00601 Totalorpartialreproductionofthisd…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BADLSD-472ReportNumber:BTF251112R00601 Totalorpartialreproductionofthisdocumentwithoutp…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yong Xiong(Manager)
[email protected]

Test Firm

BTF Testing Lab (Shenzhen) Co., Ltd.Ryan CJ
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz800.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.