Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Packing List Note: Please read the Operation Manual carefully before use and follow it strictly.
2BAI5-P600
2BAI5-P600
2BAI5-P600
ZhejiangHuafonESSTechnologyCo.,Ltd. AgentAuthorization Company:ZhejiangHuafonESSTechnologyCo.,Ltd. Address:XinchengIndustrialPark(FormerlyHuafonIndustrialPark),XinchengSub- WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown district, Rui'an, Wenzhou, Zhejiang, China Model Number(s):P600 Product Description:Portable Power Station . Signature: Date:2023.3.23 Name: FeiLiu Title: TestEngineer Company: ZhejiangHuafonESSTechnologyCo.,Ltd.
ZhejiangHuafonESSTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2023.3.23 Subject; Request for Confidentiality FCC ID: 2BAI5-P600 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:FeiLiu Title: TestEngineer
Externa FCC ID:2BAI5-P600 l Adapter
*107.7 ` 0.1 * 57.7 ` 0.1 R0.5 版本内容日期 V1.0 初版发行 2022-11-10 Model:P600 Battery Capacity:22.2V,28.6Ah (635Wh) AC Outlet(2 Ports):120V ~ ,60Hz , Power:600W (Peak Power:1200W)) USB-A(2 Ports):5V 3A,15W USB-A QC3.0(1 Port):5V 3A、9V 2A、12V 1.5A,Max Power:18W USB-C(1 Port):5V 3A、9V 3A、12V 3A、15V 3A、20V 5A, Max Power:100W Car Outlet(1 Port):12V 10A DC 5521(2 Ports):12V 5A ,the DC 5521 and the car outlet have a total output of 120W Adapter:100V-240V~,50Hz/60Hz,120W Solar Panel Input:Max 120W , Max voltage 24V USB-C(1 Port):5V 3A、9V 3A、12V 3A、15V 3A、20V 5A, Max 100W Battery Discharge Temperature:-4°F~140°F±5°F(-20°C~60°C±3°C) Battery Charge Temperature:32°F~113°F±5°F(0°C~45°C±3°C) 12001054 Warning 1.Refer to local laws and regulations for the disposal method 2.Do not disassemble, puncture, shock or burn the subject in the fire Portable Power Station FCC ID:2BAI5-P600 Label location:
Internal FCC ID:2BAI5-P600
OTA TEST REPORT Applicant Espressif Systems Product ESP ANT B Model ESP ANT B Report No. Y1806A0621-T1V3 Issue Date November 1, 2021 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in ANSI/IEEE Std 149-2008. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Prepared by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 OTA Test Report Report No: Y1806A0621-T1V3 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 2 of 14 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENTS 1. General Information................................................................................................ ....................... 3 1.1. Notes of the Test Report................................................................................................ ... 3 1.2. Testing laboratory................................................................................................ .............. 3 1.3. Laboratory Environment................................................................................................ .... 3 2. General Description of Equipment under Test................................................................ ............... 4 2.1. Applicant Information................................................................................................ ......... 4 2.2. Manufacturer Information................................................................................................ .. 4 2.3. Information of EUT................................................................................................ ............ 4 2.4. Test Date................................................................................................ ........................... 4 2.5. Applied Standards................................................................................................ ............. 5 3. Test Conditions................................................................................................ .............................. 6 3.1. Test Configuration................................................................................................ ............. 6 3.2. Test Measurement................................................................................................ ............. 6 4. Test Results................................................................................................................................ ... 7 4.1. Gain and Efficiency................................................................................................ ............ 7 4.2. Voltage Standing Wave Ratio (VSWR)................................................................ .............. 8 4.3. Antenna S11................................................................................................ ...................... 9 5. Test Equipment List ..................................................................................................................... 10 APPENDIX A: 2-D Pattern Plots ............................................................................................................. 11 APPENDIX B: The EUT Appearance and Test Configuration ............................................................. 13 B.1 EUT Appearance ................................................................................................................. 13 B.2 Test Configuration .............................................................................................................. 14 OTA Test Report Report No: Y1806A0621-T1V3 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 3 of 14 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. General Information 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd.The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. This report must not be used by the client to claim product certification, approval, or endorsement by any government agencies. 1.2. Testing laboratory Company: TA Technology (Shanghai) Co., Ltd. Address: No.145, Jintang Rd, Tangzhen Industry Park, Pudong City: Shanghai Post code: 201201 Country: P. R. China Contact: Xu Kai Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: http://www.ta-shanghai.com E-mail: [email protected] 1.3. Laboratory Environment Temperature Min. =19°C,Max. = 25°C Relative humidity Min. =40%,Max. =72% Shield effect 0.7-6GHz > 100dB Ground resistance <0.5Ω OTA Test Report Report No: Y1806A0621-T1V3 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 4 of 14 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 2. General Description of Equipment under Test 2.1. Applicant Information Company: Espressif Systems Address: #101, Block 2, 690 Bibo Road, Zhang Jiang High-Tech Park, Shanghai, China 2.2. Manufacturer Information Company: Espressif Systems Address: #101, Block 2, 690 Bibo Road, Zhang Jiang High-Tech Park, Shanghai, China 2.3. Information of EUT General information EUT Description Product Name: ESP ANT B Model ESP ANT B HW Version: / SW Version: / Antenna Type: Fixed Antenna Antenna Manufacturer: Espressif Systems Test Frequency: 2400MHz ~ 2500MHz Test lab. of the antenna gain and rad…
Text truncated - open the document above for the full version.
Page1 of 72ReportNo.: KS2303S1191E01 TRF RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TEST REPORT ReportNo................................:KS2303S1191E01 FCCID.....................................:2BAI5-P600 Applicant..................................:ZhejiangHuafonESS TechnologyCo., Ltd. Address....................................: XinchengIndustrialPark(FormerlyHuafonIndustrialPark),Xincheng Sub-district,Rui'an,Wenzhou,Zhejiang,China Manufacturer...........................:ZhejiangHuafonESS TechnologyCo., Ltd. Address....................................: XinchengIndustrialPark(FormerlyHuafonIndustrialPark),Xincheng Sub-district,Rui'an,Wenzhou,Zhejiang,China ProductName ......................... :PortablePowerStation Trademark ............................... :HuafonESS Model/Typereference............:P600 Standard..................................:47 CFRPart 15.247 Dateof Receipt.......................:March8, 2023 Dateof Test Date....................:March8, 2023to April 1, 2023 Dateof issue ........................... :April 1, 2023 Test result ............................... :Pass Preparedby: ( Printedname+ Signature)Pai Zheng Approvedby: ( Printedname+ Signature) Sky Dong TestingLaboratoryName...:KSIGN(Guangdong)TestingCo., Ltd. Address .................................... : WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrial Park,Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong, China This test reportmay be duplicatedcompletelyfor legaluse with the approvalof the applicant.It shouldnot be reproducedexceptin full, withoutthe writtenapprovalof our laboratory.The clientshouldnot use it to claim productendorsementby KSIGN.The test resultsin the reportonly applyto the testedsample.The test reportshallbe invalidwithoutall the signaturesof testingengineers,reviewerand approver.Any objections mustbe raisedto KSIGNwithin15 dayssincethe date whenthe reportis received.It will not be takeninto considerationbeyondthis limit. The test reportmerelycorrespondsto the test sample.The reportis invalidif it is not stampedwith the "TestingSpecialStamp"and the "RidingSeamStamp". Page2 of 72ReportNo.: KS2303S1191E01 TRF RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TABLEOF CONTENTSPage 1. TEST SUMMARY.............................................................................................................................................3 1.1. Test Standards.......................................................................................................................................3 1.2. ReportVersion.......................................................................................................................................3 1.3. Test Description......................................................................................................................................4 1.4. Test Facility.............................................................................................................................................5 1.5. MeasurementUncertainty......................................................................................................................6 2. GENERALINFORMATION..............................................................................................................................7 2.1. GeneralDescriptionOf EUT ..................................................................................................................7 2.2. AccessoryEquipmentInformation.........................................................................................................7 2.3. Descriptionof Test Modes......................................................................................................................7 2.4. MeasurementInstrumentsList ...............................................................................................................8 3. EvaluationResults(Evaluation)..................................................................................................................12 3.1. Antennarequirement............................................................................................................................12 4. RadioSpectrumMatterTest Results(RF) ..................................................................................................13 4.1. ConductedEmissionat AC powerline .................................................................................................13 4.2. OccupiedBandwidth............................................................................................................................16 4.3. MaximumConductedOutputPower....................................................................................................17 4.4. PowerSpectralDensity........................................................................................................................19 4.5. Emissionsin non-restrictedfrequencybands......................................................................................20 4.6. Bandedgeemissions(Radiated).........................................................................................................22 4.7. Emissionsin restrictedfrequencybands(below1GHz)......................................................................27 4.8. Emissionsin restrictedfrequencybands(above1GHz)......................................................................30 5. EUT TEST PHOTOS......................................................................................................................................37 6. PHOTOGRAPHSOF EUT CONSTRUCTION…
Text truncated - open the document above for the full version.
Page1 of 89ReportNo.: KS2303S1191E02 TRF RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TEST REPORT ReportNo................................:KS2303S1191E02 FCCID.....................................:2BAI5-P600 Applicant..................................:ZhejiangHuafonESS TechnologyCo., Ltd. Address....................................: XinchengIndustrialPark(FormerlyHuafonIndustrialPark),Xincheng Sub-district,Rui'an,Wenzhou,Zhejiang,China Manufacturer...........................:ZhejiangHuafonESS TechnologyCo., Ltd. Address....................................: XinchengIndustrialPark(FormerlyHuafonIndustrialPark),Xincheng Sub-district,Rui'an,Wenzhou,Zhejiang,China ProductName ......................... :PortablePowerStation Trademark ............................... :HuafonESS Model/Typereference............:P600 Standard..................................:47 CFRPart 15.247 Dateof Receipt.......................:March8, 2023 Dateof Test Date....................:March8, 2023to April 1, 2023 Dateof issue ........................... :April 1, 2023 Test result ............................... :Pass Preparedby: ( Printedname+ Signature)Pai Zheng Approvedby: ( Printedname+ Signature) Sky Dong TestingLaboratoryName...:KSIGN(Guangdong)TestingCo., Ltd. Address .................................... : WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrial Park,Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong, China This test reportmay be duplicatedcompletelyfor legaluse with the approvalof the applicant.It shouldnot be reproducedexceptin full, withoutthe writtenapprovalof our laboratory.The clientshouldnot use it to claim productendorsementby KSIGN.The test resultsin the reportonly applyto the testedsample.The test reportshallbe invalidwithoutall the signaturesof testingengineers,reviewerand approver.Any objections mustbe raisedto KSIGNwithin15 dayssincethe date whenthe reportis received.It will not be takeninto considerationbeyondthis limit. The test reportmerelycorrespondsto the test sample.The reportis invalidif it is not stampedwith the "TestingSpecialStamp"and the "RidingSeamStamp". Page2 of 89ReportNo.: KS2303S1191E02 TRF RF_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TABLEOF CONTENTSPage 1. TEST SUMMARY.............................................................................................................................................3 1.1. Test Standards.......................................................................................................................................3 1.2. ReportVersion.......................................................................................................................................3 1.3. Test Description......................................................................................................................................4 1.4. Test Facility.............................................................................................................................................5 1.5. MeasurementUncertainty......................................................................................................................6 2. GENERALINFORMATION..............................................................................................................................7 2.1. GeneralDescriptionOf EUT ..................................................................................................................7 2.2. AccessoryEquipmentInformation.........................................................................................................7 2.3. Descriptionof Test Modes......................................................................................................................7 2.4. MeasurementInstrumentsList ...............................................................................................................8 3. EvaluationResults(Evaluation)..................................................................................................................12 3.1. Antennarequirement............................................................................................................................12 4. RadioSpectrumMatterTest Results(RF) ..................................................................................................13 4.1. ConductedEmissionat AC powerline .................................................................................................13 4.2. OccupiedBandwidth............................................................................................................................16 4.3. MaximumConductedOutputPower....................................................................................................17 4.4. PowerSpectralDensity........................................................................................................................19 4.5. Emissionsin non-restrictedfrequencybands......................................................................................20 4.6. Bandedgeemissions(Radiated).........................................................................................................22 4.7. Emissionsin restrictedfrequencybands(below1GHz)......................................................................27 4.8. Emissionsin restrictedfrequencybands(above1GHz)......................................................................30 5. EUT TEST PHOTOS......................................................................................................................................37 6. PHOTOGRAPHSOF EUT CONSTRUCTION…
Text truncated - open the document above for the full version.
TRFNo.FCCRFExposure_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page1of2 MPEEvaluation FCCID:2BAI5-P600 ApplicableStandard KDB447498D04InterimGeneralRFExposureGuidancev01,clause2.1.4MPE-BaseExemption: AnalternativetotheSAR-basedexemptionisprovidedinclause1.1307(b)(3)(i)(C),foramuchwiderfrequencyrange, from300KHzto100GHz,applicableforseparationdistancesgreaterorequaltoλ/2π,whereλisthefree-space operatingwavelengthinmeters.TheMPE-basedtestexemptionconditionisintermsofERP,definedastheproductof themaximumantennagainandthedeliveredmaximumtime-averagedpower.Forthiscase,aRFsourceisanRF exemptdeviceifitsERP(watts)isnomorethanafrequency-dependentvalue,asdetailedtabularforminAppendixB. TheselimitshavebeenderivedbasedonthebasicspecificationsonMaximumPermissibleExposure(MPE)considered fortheFCCrulesinclause1.1310(e)(1). Tabel1-ThresholdsForSingleRfSourcesSubjectToRoutineEnvironmentalEvaluation Note:Theminimumseparationdistance(Rinmeters)fromthebodyofanearbypersonforthefrequency(finMHz)at whichthesourceoperatestheERP(watts)isnomorethanthecalculatedvalueprescribedforthatfrequency TESTRESULT PassedNotApplicable TRFNo.FCCRFExposure_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page2of2 BLE Testmode Channel Frequency (MHz) Max. Measured Power (dBm) Tuneup tolerance (dBm) Max. Tuneup Power (dBm) ERP Evaluation distance cm Exemption Limit (mW) dBmmw BLE2402-2480 1.891.89±12.892.891.9520 768 WIFI Testmode Channel Frequency (MHz) Max. Measured Power (dBm) Tuneup tolerance (dBm) Max. Tuneup Power (dBm) ERP Evaluation distance cm Exemption Limit (mW) dBmmw B/G/N20/N40 2412/2422- 2452/2462 18.1218.12±119.1219.1281.6620 768 Note: -Thetune-uppowerwasdeclaredbytheapplicant -dBi=dBd+2.15 -limit=19.2*0.2 2 =0.768W=768mW -Themaximumantennagainis3.42dBi. -TomaintaincompliancewiththeRFexposureguidelines,placetheequipmentatleast20cmfromnearbypersons -TheWIFIandBLEcannotbetransmitsimultaneously. Result:Compliant --THEEND--
ConductedEmissionatACpowerlin FCC ID:2BAI5-P600 e Emissionsinrestrictedfrequencybands(below1GHz) Emissionsinrestrictedfrequencybands(above1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 64.86 mW |