How to Use THE BREAKMASTER The BreakMaster turns on by pressing the On/Off switch at the top of the unit. It will cycle through a brief calibration sequence and then it's ready to go. It doesn't matter which direction you orient the BreakMaster. Simply place the BreakMaster on the green near the hole on line with your putt. There's no need to "aim" it, as it will work properly in any direction. It takes just three second for the BreakMaster to settle and read the green. The arrow display on the BreakMaster shows the direction of downhill slope (the direction of the break) as indicated below. If two directional arrows are illuminated, this means that the direction of the break lies between them. If all the arrows are illuminated, the surface is perfectly flat. The numeric display on the BreakMaster shows the amount (or severity) of break in degrees. What's the significance in the number of degrees? Generally, the higher the number of degrees, the more significant the angle and therefore the more your ball will break. You'll find readings under 1.0 degree will tend to break very little, if at all. At 1.5 degrees you'll begin to see increased break, and by 2.5 degrees the ball will break significantly more. At 3.0 - 4.0 degrees of break you'll find the effect of break on the ball becomes increasingly severe. The effect of the angle of breaks on your ball will also vary depending on the hard/soft or wet/dry nature of the particular green you're playing. Generally, hard or dry greens will give you a faster roll, soft or moist greens will give you a slower roll. The faster the green, the more the putt will tend to break. Conversely, the slower the green, the less the putt will break. When you're finished reading the green, simply press the on/off switch to turn the BreakMaster off and conserve battery power. If you forget to turn the BreakMaster off, it shuts itself off automatically after two minutes. Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help. FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example ‐ use only shielded interface cables when connecting to computer or peripheral devices). This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 24 External Photos Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 8 of 24
Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 9 of 24 Internal Photos Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 10 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 11 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 12 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 13 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 14 of 24
of Applicant: Ronald Wilkerson DBA BreakMaster Address: 6121 Shoup Avenue, Unit #24, Woodland Hills, CA 91367, USA Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1477, TW1072 Industry Canada filed test laboratory Reg. No.: 20037, 5107A Report No.: W6M22303-22492-EE 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] FCC RF Exposure Exemption report for Digital Green Reader Model No.: BreakMaster+ FCC ID: 2BAJB-GRBM02 Registration number: W6M22303-22492-EE FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 8 TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................................................... 2 1.1 NOTES ...................................................................................................................................................................... 2 1.2 TESTING LABORATORY ............................................................................................................................................. 3 1.2.1 Location .............................................................................................................................................................. 3 1.2.2 Details of accreditation status ............................................................................................................................ 3 1.3 DETAILS OF APPROVAL HOLDER ............................................................................................................................... 3 1.4 APPLICATION DETAILS .............................................................................................................................................. 4 1.5 GENERAL INFORMATION OF TEST ITEM ..................................................................................................................... 4 1.6 TEST STANDARDS ..................................................................................................................................................... 4 2 TECHNICAL TEST ........................................................................................................................................................ 5 2.1 SUMMARY OF TEST RESULTS ..................................................................................................................................... 5 2.2 TEST ENVIRONMENT ................................................................................................................................................. 5 2.3 TEST EQUIPMENT LIST .............................................................................................................................................. 5 3 RF EXPOSURE TEST EXEMPTIONS ........................................................................................................................ 6 4 EXEMPTION CALCULATION.................................................................................................................................... 8 Registration number: W6M22303-22492-EE FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 8 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: March 24, 2023 Sora Kuo Date WTS-Lab. Name Signature Technical responsibility for area of testing: March 24, 2023 Kevin Wang Date WTS Name Signature Registration number: W6M22303-22492-EE FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 8 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) 3 meter semi-anechoic chamber No.35, Aly. 21, Ln. 228, Ankang Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.) Tel: 886-2-6613-0228 Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114 , Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1477, TW1072 Industry Canada filed test laboratory Reg. No.: 20037, 5107A Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. Name: ./. Accredited no.: ./. Street: ./. Town: ./. Country: ./. 1.3 Details of approval holder Name: Ronald Wilkerson DBA BreakMaster Street: 6121 Shoup Avenue, Unit #24, Woodland Hills, Town: CA 91367, Country: USA Registration number: W6M22303-22492-EE FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Page 4 of 8 1.4 Application details Date of receipt of test item: March 09, 2023 Date of test: from March 10, 2023 to March 23, 2023 1.5 General information of Test item Type of test item: Digital Green Reader Model no.: Brea…
Text truncated - open the document above for the full version.
of Applicant: Ronald Wilkerson DBA BreakMaster Address: 6121 Shoup Avenue, Unit #24, Woodland Hills, CA 91367, USA Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1477, TW1072 Industry Canada filed test laboratory Reg. No.: 20037, 5107A Report No.: W6M22303-22492-C-1 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] 47 CFR PART 15 SUBPART C TEST REPORT for Digital Green Reader Model No.: BreakMaster+ FCC ID: 2BAJB-GRBM02 Registration number: W6M22303-22492-C-1 FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 28 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 NOTES .......................................................................................................................................... 2 1.2 TESTING LABORATORY ................................................................................................................ 3 1.3 A PPLICATION DETAILS ................................................................................................................. 3 1.4 G ENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.5 P OWER SETTING ........................................................................................................................... 4 1.6 D UTY CYCLE AND FACTOR ........................................................................................................... 5 1.7 T EST STANDARDS ......................................................................................................................... 6 2 TEST CONFIGURATION .............................................................................................................. 7 2.1 T EST ENVIRONMENT .................................................................................................................... 7 2.2 MEASUREMENT UNCERTAINTY .................................................................................................... 7 2.3 T EST EQUIPMENT LIST ................................................................................................................. 8 3 TEST RESULTS (ENCLOSURE) ................................................................................................ 11 3.1 P EAK OUTPUT POWER (TRANSMITTER) ...................................................................................... 12 3.2 SPURIOUS EMISSIONS RADIATED – TRANSMITTER OPERATING ................................................... 15 3.3 E MISSIONS IN NONRESTRICTED FREQUENCY BANDS ................................................................... 17 3.4 M INIMUM 6 DB BANDWIDTH ..................................................................................................... 19 3.5 PEAK POWER SPECTRAL DENSITY ............................................................................................. 22 3.6 P OWER LINE CONDUCTED EMISSION ......................................................................................... 25 Appendix: Diagrams Registration number: W6M22303-22492-C-1 FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 28 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: March 24, 2023 Sora Kuo Date WTS-Lab. Name Signature Technical responsibility for area of testing: March 24, 2023 Kevin Wang Date WTS Name Signature Registration number: W6M22303-22492-C-1 FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 28 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) 3 meter semi-anechoic chamber No.35, Aly. 21, Ln. 228, Ankang Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.) Tel: 886-2-6613-0228 Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114 , Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1477, TW1072 Industry Canada filed test laboratory Reg. No.: 20037, 5107A Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. : Name: ./. Accredited no.: ./. Street: ./. Town: ./. Country: ./. 1.3 Application details Approval holder Name: Ronald Wilkerson DBA BreakMaster Street: 6121 Shoup Avenue, Unit #24, Woodland Hills, Town: CA 91367, Country: USA Manufacturer: (if applicable) Name: ./. Street: ./. Town: ./. Country: ./. Registration number: W6M22303-22492-C-1 FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Page 4 of 28 Date of receipt of test item: March 09, 2023 Date …
Text truncated - open the document above for the full version.
承 認 書 SPECIFICATION FOR APPROVAL 客戶名稱 CUSTOMER : 客戶料號 CUSTOMER’S P/N : 料號 PART NUMBER : WAN3216F245W36 規格 DESCRIPTION : Chip Antenna 3216 M-Ant 2.45G Type 36 版本 VERSION : V2.0 日期 ISSUE DATE : 2016/08/04 客 戶 承 認 CUSTOMER APPROVED 工 程 部 R&D CENTER 承 認 APPROVAL 確 認 CHECKED 製 作 DRAWN Ray Thor Rocky 富廷科技股份有限公司 Hong Kong RIMON TECHNOLOGY CO., LTD. RIMON TECHNOLOGY CO., LTD. 香港九龍旺角彌敦道582-592號信和中心804室 114台北市內湖區內湖路2段352號4樓之6 RM804, Sino Centre., 582-592 Nathan Rd., Kln, Hong Kong 4F-6, No.352, Sec. 2, Neihu Rd., Neihu District,Taipei 114, Taiwan 電話: +886-2-2796-2568 傳真: +886-2-2796-6433 E-mail : [email protected] 3216 Chip antenna For Bluetooth / WLAN Applications RIMON TECHNOLOGY CO., LTD. 2/11 Dimension (mm) L 3.23 ± 0.20 W 1.66 ± 0.20 T 1.23 ± 0.20 P/N:WAN3216F245W36 Part Number Information WAN 3216 F 245 W 36 A B C D E F A Product Series Antenna B Dimension L x W 3.2X1.6mm (+‐0.2mm) C Material High K material D Working Frequency 2.4 ~ 2.5GHz E Feeding mode Function Antenna F Antenna type Type=36 1. Electrical Specification Specification Part Number WAN3216F245W36 Central Frequency 2450 MHz Bandwidth 100 (Min.) MHz Return Loss ‐6.5 (Max) dB Peak Gain 2.71 dBi Impedance 50 Ohm Operating Temperature ‐40~+85 °C Maximum Power 4 W Resistance to Soldering Heats 10 ( @ 260°C) sec. Polarization Linear Azimuth Beamwidth Omni‐directional Termination Cu / Sn (Leadless) Remark : Bandwidth & Peak Gain was measured under evaluation board of next page RIMON TECHNOLOGY CO., LTD. 3/11 2. Recommended PCB Pattern Evaluation Board Dimension Suggested Matching Circuit RIMON TECHNOLOGY CO., LTD. 4/11 Layout Dimensions in Clearance area (Size=5.2*5.0mm) RIMON TECHNOLOGY CO., LTD. 5/11 50 ohm transmission Line Matching Circuit FootPrint (Unit : mm) 3. Measurement Results Return Loss RIMON TECHNOLOGY CO., LTD. 6/11 Radiation Pattern Y RIMON TECHNOLOGY CO., LTD. 7/11 X Z Efficiency Peak Gain Directivity 2400MHz 55.21 % 1.45 dBi 5.32 dBi 2450MHz 66.45 % 2.71 dBi 5.21 dBi 2500MHz 57.53 % 1.98 dBi 5.29 dBi Chamber Coordinate System 4. Reliability and Test Condictions ITEM REQUIREMENTS TEST CONDITION Solderability 1. Wetting shall exceed 90% coverage 2. No visible mechanical damage Pre‐heating temperature:150°C/60sec. Solder temperature:230±5°C Duration:4±1sec. Solder:Sn‐Ag3.0‐Cu0.5 Flux for lead free: rosin Solder heat Resistance 1. No visible mechanical damage 2. Central Freq. change :within ± 6% 10±0.5 sec. 60sec TEMP (°C) 150°C 260°C Pre‐heating temperature:150°C/60sec. Solder temperature:260±5°C Duration:10±0.5sec. Solder:Sn‐Ag3.0‐Cu0.5 Flux for lead free: rosin Component Adhesion (Push test) 1. No visible mechanical damage The device should be reflow soldered(230±5°C for 10sec.) to a tinned copper substrate A dynometer force gauge should be applied the side of the component. The device must with-ST-F 0.5 Kg without failure of the termination attached to component. Component Adhesion (Pull test) 1. No visible mechanical damage Insert 10cm wire into the remaining open eye bend ,the ends of even wire lengths upward and wind together. Terminal shall not be remarkably damaged. Thermal shock 1. No visible mechanical damage 2. Central Freq. change :within ±6% Phase Temperature(°C) Time(min) 1 +85±5°C 30±3 2 Room Temperature Within 3sec 3 -40±2°C 30±3 4 Room Temperature Within 3sec +85°C=>30±3min -40°C=>30±3min Test cycle:10 cycles The chip shall be stabilized at normal condition for 2~3 hours before measuring. Resistance to High Temperature 1. No visible mechanical damage 2. Central Freq. change :within ±6% 3. No disconnection or short circuit. Temperature: 85±5°C Duration: 1000±12hrs The chip shall be stabilized at normal condition for 2~3 hours before measuring. Resistance to Low Temperature 1. No visible mechanical damage 2. Central Freq. change :within ±6% 3. No disconnection or short circuit. Temperature:-40±5°C Duration: 1000±12hrs The chip shall be stabilized at normal condition for 2~3 hours before measuring. Humidity 1. No visible mechanical damage 2. Central Freq. change :within ±6% 3. No disconnection or short circuit. Temperature: 40±2°C Humidity: 90% to 95% RH Duration: 1000±12hrs The chip shall be stabilized at normal condition for 2~3 hours before measuring. 4±1 sec. 60sec TEMP (°C) 150°C 230°C RIMON TECHNOLOGY CO., LTD. 8/11 5.Soldering and Mounting Mildly activated rosin fluxes are preferred. The minimum amount of solder can lead to damage from the stresses caused by the difference in coefficients of expansion between solder, chip and substrate. The terminations are suitable for all wave and re-flow soldering systems. If hand soldering cannot be avoided, the preferred technique is the utilization of hot air soldering tools. Recommended temperature profiles for re-flow soldering in Figure 1. Products attachment with a soldering iron is discouraged due to the inherent process control limitations. In the event that a soldering iron must be employed the following precautions are recommended. ‧Preheat circuit and products to 150°C ‧Never contact the ceramic with the iron tip ‧Use a 20 watt soldering iron with tip diameter of 1.0mm ‧280°C tip temperature (max) ‧1.0mm tip diameter (max) ‧Limit soldering time to 3 sec. RIMON TECHNOLOGY CO., LTD. 9/11 6.Packaging Information Tape Specification: P2 F E P0 D 0 P B0 W A0 K0 T W Ao Bo Ko P F E D D1 Po P2 t 8.0 ±0.30 1.80 ±0.05 3.51 ±0.10 1.59 ±0.10 4.00 ±0.05 3.50 ±0.05 1.75 ±0.10 1.50 ±0.10 0.00 ±0.10 4.00 ±0.10 2.00 ±0.05 0.25 ±0.05 Reel Specification: (7’’, Φ180 mm) Tape Width(mm) A(mm) B(mm)C(mm) D(mm)Chip/Reel(pcs) 8 9.0±0.5 60±2 13.5±0.5178±23000 RIMON TECHNOLOGY CO., LTD. 10/11 RIMON TECHNOLOGY CO., LTD. 11/11 7.Storage and Transportation Information Storage Conditions To maintain the solderability of terminal electrodes: 1. Temperature and humidity conditions: -10~ 40°C and 30~70% RH. 2. Recommended products should be used within 6 months from the time of delivery. 3. The packaging material should be kept where no chlorine or sulfur exists in the air. Transpo…
Text truncated - open the document above for the full version.
Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 15 of 24 Set Up Photo of Radiated Emission EMI Battery Below 1GHz Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 16 of 24 Above 1GHz Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 17 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 18 of 24 Charge Below 1GHz Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 19 of 24 Above 1GHz Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 20 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 21 of 24 RF Below 1GHz Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 22 of 24 Above 1GHz Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 23 of 24 Registration number: W6M22303-22492-FCC FCC ID: 2BAJB-GRBM02 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 24 of 24 Set Up Photo of Conducted Emission
6F., No.58, Lane 188, Ruey Kuand Rd., · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 300.00 µW |