2BAKG-US67-V1T-BLECompact sensor for monitoring the condition of machines

Weidmuller Interface GmbH & Co. KG
Compact sensor for monitoring the condition of machines - FCC ID 2BAKG-US67-V1T-BLE - Weidmuller Interface GmbH & Co. KG
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 03, 2023
Application Purpose
Original Equipment
Date of Application
Oct 03, 2023
Equipment Note
Compact sensor for monitoring the condition of machines
Frequency Range
2402.00000000 - 2480.00000000
Company
Weidmuller Interface GmbH & Co. KG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 / 42819630000/03/06.2023 Bedienungsanleitung Smart Sensor u-sense vibration Operating instructions Smart sensor u-sense vibration Mode d’emploi Capteur de vibrations intelligent u-sense Istruzioni per l’uso Sensore intelligente u-sense vibration Instrucciones de empleo Sensor inteligent u-sense vibration US67-V1T-BLE 2751260000 Zubehör / Accessories / Accessoires / Accessori / Accesorios US67-BAT-COSL 2757620000 US67-PLATE64-STD 2811910000 US67-USB-STICK-BLE 2874720000 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 www.weidmueller.com 2819630000/03/06.2023 DEUTSCH Bestimmungsgemäßer Gebrauch Der Smart Sensor u-sense vibration ist für die Zustandsüberwachung einer rotierenden Ma- schine im industriellen Umfeld vorgesehen. Der Sensor muss gemäß DIN ISO 10816 am Stator der zu überwachenden Maschine be- festigt werden. An einer Anlage können meh- rere Sensoren verwendet werden. Das Gerät entspricht der Schutzart IP66. Für den Betrieb des Sensors sind folgende Geräte und Software notwendig: –Weidmüller IoT-Gateway mit den integrier- ten Web-Anwendungen u-create web und u-sense vibration configurator –ein Bluetooth-fähiger USB-Stick (z. B. Weidmüller Stick US67-USB-STICK-BLE 2874720000) Für die Inbetriebnahme des Sensors ist ein Rechner notwendig, der sich in demselben Netzwerk befindet wie das IoT-Gateway. Funktionsbeschreibung In benutzerdefinierten Zeitintervallen er- wacht der Sensor aus dem Energiesparmo- dus und misst die lokale Beschleunigung in drei Raumachsen und die Temperatur. Aus den Rohdaten berechnet der Sensor cha- rakteristische Datenmerkmale und übermit- telt diese per Bluetooth an das IoT-Gateway. Das IoT-Gateway übermittelt die Daten an die Web-Anwendung u-create web. Aus den übermittelten Gerätedaten kann der Betriebs- zustand ermittelt und visualisiert werden. Ent- sprechend vorgegebener Parameter können Warnmeldungen generiert werden. Mit der Software u-sense vibration configurator kann der Sensor konfiguriert werden. ENGLISH Intended use The u-sense vibration smart sensor is inten- ded for the condition monitoring of a rotating machine in an industrial environment. The sensor must be attached to the stator of the machine to be monitored in accordance with DIN ISO 10816. Several sensors can be used on a single system. The device conforms to the degree of protec- tion IP66. The following devices and software are requi- red to operate the sensor: –Weidmüller IoT gateway with the integra- ted u-create web and u-sense vibration configurator web applications –a Bluetooth-compatible USB stick (e.g. Weidmüller Stick US67-USB-STICK-BLE 2874720000) A computer located in the same network as the IoT gateway is required for commissio- ning the sensor. Functional description At user-defined time intervals, the sensor wa- kes up from energy-saving mode and mea- sures the local acceleration in three spatial axes and temperature. From the raw data, the sensor calculates characteristic data fea- tures and transmits them to the IoT gateway via Bluetooth. The IoT gateway transmits the data to the u-create web application. The operating state can be determined and visu- alised from the transmitted device data. War- ning messages can be generated according to predefined parameters. The sensor can be configured with the u-sense vibration configu- rator software. FRANÇAIS Utilisation prévue Le capteur intelligent u-sense vibration est conçu pour la surveillance de l’état d’une ma- chine à rotation dans le secteur industriel. Le capteur doit être fixé selon DIN ISO 10816 sur le stator de la machine à surveiller. Plu- sieurs capteurs peuvent être utilisés sur une installation. L'appareil correspond au degré de protec- tion IP66. Pour le fonctionnement du capteur, les ap- pareils et logiciels suivants sont nécessaires. –Passerelle Weidmüller IoT avec les appli- cations web intégrées u-create web et u-sense vibration configurator –une clé USB compatible Bluetooth (par ex. clé Weidmüller US67-USB-STICK-BLE 2874720000) Pour la mise en service du capteur, un ordi- nateur se trouvant sur le même réseau que la passerelle IoT est nécessaire. Description du fonctionnement Aux intervalles définis par l’utilisateur, le cap- ter sort du mode d'économie d'énergie et me- sure l’accélération locale sur les trois axes et la température. À partir des données bru- tes, le capteur calcule les caractéristiques de données spécifiques et les transmet à la passerelle IoT en Bluetooth. La passerel- le IoT transmet les données à l’application web u-create web. À partir des données d'appareil transmises, l’état de fonctionne- ment peut être défini et visualisé. En fonc- tion des paramètres prescrits, des messages d'avertissement peuvent être générés. Le capteur peut être configuré avec le logiciel u-sense vibration configurator. ITALIANO Uso previsto Smart Sensor u-sense vibration è pensato per il monitoraggio di una macchina rotante in ambito industriale. Il sensore deve essere fis- sato a norma DIN ISO 10816 allo statore del- la macchina da monitorare. Su un impianto possono essere utilizzati più sensori. L’apparecchio presenta un grado di protezi- one IP66. Per il funzionamento del sensore occorrono i seguenti apparecchi e software: –Weidmüller IoT-Gateway con le applicazio- ni web integrate u-create web e u-sense vibration configurator –una chiavetta USB dotata di bluetooth (es. chiavetta Weidmüller US67-USB-STICK-BLE 2874720000) Per la messa in funzione del sensore oc- corre un computer collegato alla stessa rete dell’IoT-Gateway. Descrizione del funzionamento A intervalli temporali definiti dall’utente, il sen- sore si riprende dalla modalità a risparmio energetico e misura l’accelerazione locale su tre assi spaziali e la temperatura. Dai da- ti grezzi, il sensore calcola le caratteristiche dei dati e le trasmette all’IoT-Gateway via blu- etooth. L’IoT-Gateway invia a sua volta i da- ti all’applicazione web u-create web. I dati dell’apparecchio t…

Text truncated - open the document above for the full version.

Attestation Statements

1 Kommanditgesellschaft Sitz: Detmold Amtsgericht Lemgo HRA 2790 USt-ID-Nr. DE124599660 Komplementärin: Weidmüller Interface Führungsgesellschaft mbH Sitz: Detmold Amtsgericht Lemgo HRB 3924 Geschäftsführer: Dr. Timo Berger Volker Bibelhausen André Sombecki Bankverbindungen: Commerzbank AG IBAN: DE27 4808 0020 0283 3128 00 BIC: DRESDEFF480 Deutsche Bank IBAN: DE28 4767 0023 0437 5580 00 BIC: DEUTDE3B476 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: CFR 47 §2.911 (d)(5) Attestation Date: 03-16-2023 FCC ID: 2BAKG-US67-V1T-BLE To whom it may concern 1. Weidmüller Interface GmbH & Co. KG (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2. Weidmüller Interface GmbH & Co. KG (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Best regards Weidmüller Interface GmbH & Co. KG Sascha Dreifert Vice President BU Power Supplies & Interface Electronics Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 32758 Detmold Germany T +49 5231 14-0 F +49 5231 14-292083 Sascha Dreifert T +49 5231 14-292761 [email protected] Detmold, 06/16/2023 Page 1 of 1

Attestation Statements

1 Kommanditgesellschaft Sitz: Detmold Amtsgericht Lemgo HRA 2790 USt-ID-Nr. DE124599660 Komplementärin: Weidmüller Interface Führungsgesellschaft mbH Sitz: Detmold Amtsgericht Lemgo HRB 3924 Geschäftsführer: Dr. Timo Berger Volker Bibelhausen André Sombecki Bankverbindungen: Commerzbank AG IBAN: DE27 4808 0020 0283 3128 00 BIC: DRESDEFF480 Deutsche Bank IBAN: DE28 4767 0023 0437 5580 00 BIC: DEUTDE3B476 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: CFR 47 §2.911 (d)(7) Agent Designation Attestation Date: 03-16-2023 FCC ID: 2BAKG-US67-V1T-BLE To whom it may concern Weidmüller Interface GmbH & Co. KG (“the applicant”) as required by section 2.911(d)(7), designates the following agent, located in the United States, for purposes of acting as the applicant’s agent for service of process. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. U. S. Agent Information: Kevin Dascotte Weidmuller Inc. 821 Southlake Blvd., Richmond, VIRGINIA 23236 USA [email protected] Best regards Weidmüller Interface GmbH & Co. KG Sascha Dreifert Vice President BU Power Supplies & Interface Electronics Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 32758 Detmold Germany T +49 5231 14-0 F +49 5231 14-292083 Sascha Dreifert T +49 5231 14-292761 [email protected] Detmold, 06/16/2023 Page 1 of 1

Cover Letter(s)

1 Kommanditgesellschaft Sitz: Detmold Amtsgericht Lemgo HRA 2790 USt-ID-Nr. DE124599660 Komplementärin: Weidmüller Interface Führungsgesellschaft mbH Sitz: Detmold Amtsgericht Lemgo HRB 3924 Geschäftsführer: Dr. Timo Berger Volker Bibelhausen André Sombecki Bankverbindungen: Commerzbank AG IBAN: DE27 4808 0020 0283 3128 00 BIC: DRESDEFF480 Deutsche Bank IBAN: DE28 4767 0023 0437 5580 00 BIC: DEUTDE3B476 Telecommunication Certification Body UL International (UK) Ltd. Units 1-3, Horiz Wade Road Kingsland Business Park Basingstoke Hampshire RG24 8AH United Kingdom Subject: Authorisation Letter To whom it may concern This is to certify that Weidmüller Interface GmbH & Co. KG hereby authorises UL International (UK) Ltd. to act as the TCB for the application of the smart sensor US67-V1T-BLE, 2BAKG-US67-V1T-BLE, to the FCC. We certify that we are not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. Best regards Weidmüller Interface GmbH & Co. KG Sascha Dreifert Vice President BU Power Supplies & Interface Electronics Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 32758 Detmold Germany T +49 5231 14-0 F +49 5231 14-292083 Sascha Dreifert T +49 5231 14-292761 [email protected] Detmold, 06/16/2023 Page 1 of 1

Cover Letter(s)

1 Kommanditgesellschaft Sitz: Detmold Amtsgericht Lemgo HRA 2790 USt-ID-Nr. DE124599660 Komplementärin: Weidmüller Interface Führungsgesellschaft mbH Sitz: Detmold Amtsgericht Lemgo HRB 3924 Geschäftsführer: Dr. Timo Berger Volker Bibelhausen André Sombecki Bankverbindungen: Commerzbank AG IBAN: DE27 4808 0020 0283 3128 00 BIC: DRESDEFF480 Deutsche Bank IBAN: DE28 4767 0023 0437 5580 00 BIC: DEUTDE3B476 Telecommunication Certification Body UL International (UK) Ltd. Units 1-3, Horiz Wade Road Kingsland Business Park Basingstoke Hampshire RG24 8AH United Kingdom Subject: Permanent Confidentiality Request Certification Application FCC ID: 2BAKG-US67-V1T-BLE To whom it may concern Pursuant to Sections 0.457(d) and 0.459 of CFR 47 Weidmüller Interface GmbH & Co. KG requests that the following information, provided to support the FCC application for the smart sensor US67-V1T-BLE, FCC ID 2BAKG-US67-V1T-BLE, be held permanently confidential: Schematics Parts List Operational Description Block Diagram The above material contains trade secrets not customarily released to public that are judged to have the potential to cause detriment to the applicant and provide unjustified benefits to its competitors. This information should not be available for public disclosure for an indefinite period of time. Best regards Weidmüller Interface GmbH & Co. KG Sascha Dreifert Vice President BU Power Supplies & Interface Electronics Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 32758 Detmold Germany T +49 5231 14-0 F +49 5231 14-292083 Sascha Dreifert T +49 5231 14-292761 [email protected] Detmold, 06/16/2023 Page 1 of 1

ID Label/Location Info

HVIN PMN FCC ID ISED ID

Internal Photos

u-sense Internal photos Top of PCB Bottom of PCB BT transmitter and chip antenna

RF Exposure Info

I I RF Exposure Considerations for the u-sense vibration Seite 1 von 2 \ Page 1 of 2 FCC ID: 2BAKG-US67-V1T-BLE The u-sense vibration equipment operates using 2.4GHz Bluetooth LE The following FCC Rule Parts are applicable: Part 2.1091 – Radiofrequency radiation exposure evaluation: mobile devices Part 1.1307(b)(3)(i)(C) - SAR test exemption (ii) Part 1.1307(b)(3)(i)(B) - SAR test exemption (iii) KDB 447498 D04 – RF Exposure Procedures For the u-sense vibration BT Operating Frequency: 2402 – 2480MHz Tx Power: +8.0dBm Antenna gain 0.5dBi EIRP = +8.5dBm ERP = 8.5 - 2.15dBm = 6.35dBm (4.31mW) Minimum separation distance (R) = 20cm (0.2m) Evaluation From Part 2.1093(c)(1). RF exemption applies if the maximum transmitted power is less than the maximum of the following three criteria: i) Less than 1 mw Blanket exemption. P TH = 0.001 W – (The BT32D is not compliant) ii) determination of exemption under the MPE-based §1.1307(b)(3)(i)(C), if i) not met iii) determination of exemption under the SAR-based §1.1307(b)(3)(i)(B) if both i) and ii) are not met; Determination of threshold power (P TH ) under the MPE-based §1.1307(b)(3)(i)(C) This is only applicable at a separation distance greater than λ/2π For the u-sense vibration: 2.4GHz operation - λ/2π = 0.02m The separation distance is 0.2m, therefore §1.1307(b)(3)(i)(C), is applicable I I RF Exposure Considerations for the u-sense vibration Seite 2 von 2 \ Page 2 of 2 From §1.1307(b)(3)(i)(C), Table 1: Threshold ERP P TH (2.4GHz) = 19.2R 2 watts (R = metres) ie: P TH = 19.2 x 0.2 2 P TH = 0.768W ie: Threshold Power P TH = 768mW ERP The u-sense vibration max. transmitter power = 4.31mW, so is therefore exempt from MPE evaluation in accordance with §1.1307(b)(3)(i)(C).

Test Report

UL INTERNATIONAL GERMANY GMBH Hedelfinger Str. 61 70327 Stuttgart, Germany [email protected] TEST REPORT Test Report No. : UL-RPT-RP-13304752-916-FCC Applicant * : Weidmüller Interface GmbH & Co KG Model No. * : US67-V1T-BLE / 2751260000 FCC ID * : 2BAKG-US67-V1T-BLE Technology * : Bluetooth 4.0 – Low Energy Test Standard(s) : FCC Parts 15.207, 15.209(a) & 15.247 For details of applied tests refer to test result summary 1. This test report shall not be reproduced in full or partial, without the written approval of UL International Germany GmbH. 2. The results in this report apply only to the sample tested. 3. The test results in this report are traceable to the national or international standards. 4. Test Report Version 1.2 supersede Version 1.1 with immediate effect Test Report No. UL-RPT-RP-1 3304752-916-FCC Version 1.2, Issue Date 15 SEPTEMBER 2023 replaces Test Report No. UL-RPT-RP-13304752-916-FCC Version 1.1, Issue Date 11 SEPTEMBER 2022, which is no longer valid. 5. Result of the tested sample: PASS 6. All information marked with a (*) were provided by customer / applicant or authorized representative _____________________________ _________________________ Prepared by: Muhammad Faiq Khan Approved by: Rachid Acharkaoui Title: Project Engineer Title: Operations Manager Date: 15 September 2023 Date: 15 September 2023 This laboratory is accredited by DAkkS. The tests reported herein have been performed in accordance with its’ terms of accreditation. UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-13304752-916-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 15 SEPTEMBER 2023 Page 2 of 54 FCC 15.247 BT LE - Template Vers. 2.0 This page has been left intentionally blank. UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-13304752-916-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 15 SEPTEMBER 2023 Page 3 of 54 FCC 15.247 BT LE - Template Vers. 2.0 Table of Contents 1. Customer Information * ........................................................................................................... 4 1.1. Applicant Information 4 1.2. Manufacturer Information 4 2. Summary of Testing ................................................................................................................. 5 2.1. General Information 5 Applied Standards 5 Location 5 Date information 5 2.2. Summary of Test Results 6 2.3. Methods and Procedures 6 2.4. Deviations from the Test Specification 6 3. Equipment Under Test (EUT) .................................................................................................. 7 3.1. Identification of Equipment Under Test (EUT) * 7 3.2. Description of EUT * 7 3.3. Modifications Incorporated in the EUT 7 3.4. Additional Information Related to Testing 8 3.5. Support Equipment 8 A. Support Equipment (In-house) 8 B. Support Equipment (Manufacturer supplied) * 8 4. Operation and Monitoring of the EUT during Testing ........................................................... 9 4.1. Operating Modes 9 4.2. Configuration and Peripherals 9 5. Measurements, Examinations and Derived Results ............................................................ 11 5.1. General Comments 11 5.2. Test Results 12 5.2.1. Transmitter Minimum 6 dB Bandwidth 12 5.2.2. Transmitter Duty Cycle 17 5.2.3. Transmitter Maximum (Peak) Output Power 22 5.2.4. Transmitter Radiated Emissions 31 5.2.5. Transmitter Band Edge Radiated Emissions 42 6. Measurement Uncertainty ..................................................................................................... 52 7. Used equipment ..................................................................................................................... 53 8. Report Revision History ........................................................................................................ 54 UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-13304752-916-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 15 SEPTEMBER 2023 Page 4 of 54 FCC 15.247 BT LE - Template Vers. 2.0 1. Customer Information * 1.1.Applicant Information Company Name: Weidmüller Interface GmbH & Co KG Company Address: Klingenbergstr. 26, 32758 Detmold, Germany Company Phone No.: +49 5231 14-0 Company E-Mail: [email protected] Contact Person: Franz-Josef Hegener Contact E-Mail Address: [email protected] Contact Phone No.: +49 5231 14-292445 1.2.Manufacturer Information Company Name: Weidmüller Interface GmbH & Co KG Company Address: Klingenbergstr. 26, 32758 Detmold, Germany Company Phone No.: +49 5231 14-0 Company E-Mail: [email protected] Contact Person: Franz-Josef Hegener Contact E-Mail Address: [email protected] Contact Phone No.: +49 5231 14-292445 UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-13304752-916-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 15 SEPTEMBER 2023 Page 5 of 54 FCC 15.247 BT LE - Template Vers. 2.0 2. Summary of Testing 2.1. General Information Specification Reference: 47CFR15.247 Specification Title: Code of Federal Regulations Volume 47 (Telecommunications): Part 15 Subpart C (Intentional Radiators) - Section 15.247 Specification Reference: 47CFR15.207 and 47CFR15.209 Specification Title: Code of Federal Regulations Volume 47 (Telecommunications): Part 15 Subpart C (Intentional Radiators) - Sections 15.207 and 15.209 Applied Standards Location Location of Testing: UL International Germany GmbH Hedelfinger Str. 61 70327 Stuttgart Germany Test Firm Registration: 399704 Date information Order Date: 31 March 2020 EUT arrived: 14 June 2022 Test Dates: 20 June 2022 to 21 June 2022 EUT returned: -/- UL INTERNATIONAL GERMANY GMBH TEST REPORT NO: UL-RPT-RP-13304752-916-FCC TEST REPORT VERSION 1.2 ISSUE DATE: 15 SEPTEMBER 2023 Page 6 of 54 FCC 15.247 BT LE - Template Vers. 2.0 2.2.Summary of Test Results Clause Measurement Complied Did not comply Not performed Not applicable Part 15.207 Transmitter AC Conducted Emissions (1) ☐ ☐ ☐ ☒ Part 15.247(a)(2) Transmitter Minimum 6 dB Bandwidth ☒ ☐ ☐ ☐ Part 15.35(c) Transmitter…

Text truncated - open the document above for the full version.

Test Report

LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 FeaturesApplications Electrical Specifications •2450MHz, Bandwidth ≥90MHz •Suitable for RoHS compliant reflow •Gain 0.5dBi (Peak) / -1dBi (Average) •VSWR <2:1 •Small size – 3.2 x 1.6 x 1.2mm (0.125 x 0.62 x 0.047 inch) •Non Ground Mounting type. •Power Handling 3W Max •Matched to 50 Ohm. •Wireless application - Bluetooth / WiFi (2.445GHz) •High density applications •Bluetooth headsets or ear pieces •Computer mouse and keyboards •PROFINET – Industrial automation •Video Game systems •Alternative to larger PCB solution ParameterMin.Typ.Max.UnitsNote Frequency2450MHz Bandwidth100MHz Peak Gain0.5dBi Average Gain-1dBi VSWR2 Impedance50Ω Power Capability3W Environmental Characteristics ParametersSpecification Environmental friendlyPb-free MSL1 Operating Temperature-40 ºC to + 85 ºC Storage Temperature-10 ºC to +40 ºC Relative Humidity70% LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Product Dimensions and PCB Land Drawing (Unit: mm) This is the feed-line to the Antenna and should be matched to 50 Ohms based upon the PCB dielectric parameters. SeriesABCDEFGH AMCA313.2±0.21.6±0.21.2±0.20.5±0.21.6±0.20.8±0.20.8±0.22.6±0.2 No.Terminal NameNo.Terminal Name Pad 1Feed PointPad 2NC Terminal Configurations LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Application Test Circuit & PCB layouts – Default Layouts Figure shows the PCB layout highlighting the Ground and No Ground areas and trace feed line to the chip antenna. Matching Circuit and Reference Values ComponentDescriptionValue AntennaAMCA31-2R450G-S1F-T3---- Capacitor *Series C0.5 ~ 10 pF *Shunt C33pF, 100 pF Inductor Series L1.0 ~ 6nH Shunt L1.0 ~ 6nH *Series: Connected between antenna and feeding line in series. *Shunt: Connected between antenna and feeding line in parallel Note: Recommendation is to pre-place the π-type circuit layout circuit which will offer full flexibility to match the antenna to 50 Ohm in the final product layout with one of the match configurations below. Depending on matching, NC will apply to certain components. Network Analyzer LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Matching Circuit on Evaluation Board • Line width should be designed to match 50 Ω characteristic impedance, depending on PCB material and thickness. • The component values given above will be vary based on the PCB layout Return Loss, VSWR and Impedance Characteristics Before Matching LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Return Loss, VSWR and Impedance Characteristics Cont. After Matching Radiation Pattern and Gain Test Setup LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Radiation Pattern and Gain XY Plane LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Radiation Pattern and Gain XZ Plane LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Radiation Pattern and Gain YZ Plane LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Radiation Pattern and Gain 3D – Pattern | (2400 MHz, 2450 MHz, 2500 MHz) Frequency (MHz)Gain (dBi) 2400-4.125434820 2410-4.180958401 2420-3.877599807 2430-3.930632294 2440-3.676540694 2450-3.582882743 2460-3.534294730 2470-3.598055402 2480-3.690017588 2490-3.876259790 2500-3.918544199 Gain LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450…

Text truncated - open the document above for the full version.

Test Setup Photos

Weidmüller Interface GmbH & Co KG FCC ID: 2BAKG-US67-V1T-BLE UL-RPT-RP-13304752-916 ISED Certification No.: IC: 22915-US67V1TBLE UL International Germany GmbH 1 Test Setup Photographs for Model No. / PMN: US67-V1T-BLE 1.Transmitter Radiated Emissions 1.1.Radiated Emissions: 9 kHz to 30 MHz @ 3 m Picture 1 Radiated Test Setup-9 kHz to 30 MHz Photo 2: Radiated Test Setup-9 kHz to 30 MHz Weidmüller Interface GmbH & Co KG FCC ID: 2BAKG-US67-V1T-BLE UL-RPT-RP-13304752-916 ISED Certification No.: IC: 22915-US67V1TBLE UL International Germany GmbH 2 1.2.Radiated Emissions: 30 MHz to 1GHz @ 3 m Photo 3: Radiated Test Setup-30 MHz to 1GHz Photo 4: Radiated Test Setup-30 MHz to 1GHz Weidmüller Interface GmbH & Co KG FCC ID: 2BAKG-US67-V1T-BLE UL-RPT-RP-13304752-916 ISED Certification No.: IC: 22915-US67V1TBLE UL International Germany GmbH 3 1.3.Radiated Emissions: 1 GHz to 18 GHz @ 3 m Photo 5: Radiated Test Setup-1 GHz to 18 GHz Photo 6: Radiated Test Setup-1 GHz to 18 GHz Weidmüller Interface GmbH & Co KG FCC ID: 2BAKG-US67-V1T-BLE UL-RPT-RP-13304752-916 ISED Certification No.: IC: 22915-US67V1TBLE UL International Germany GmbH 4 Photo 7: Radiated Test Setup-1 GHz to 18 GHz Weidmüller Interface GmbH & Co KG FCC ID: 2BAKG-US67-V1T-BLE UL-RPT-RP-13304752-916 ISED Certification No.: IC: 22915-US67V1TBLE UL International Germany GmbH 5 1.4.Radiated Emissions: 18 GHz to 25 GHz @ 1 m Photo 8 Radiated Test Setup-18 GHz – 25 GHz Photo 9 Radiated Test Setup-18 GHz – 25 GHz Weidmüller Interface GmbH & Co KG FCC ID: 2BAKG-US67-V1T-BLE UL-RPT-RP-13304752-916 ISED Certification No.: IC: 22915-US67V1TBLE UL International Germany GmbH 6 2.Transmitter Conducted Measurements 2.1.Conducted Measurements Photo 10: Conducted Test Setup-with DC Power Supply Photo 11: Conducted Test Setup-with DC Power Supply

Contact Information

Applicant

Sascha Dreifert
[email protected]+49 5231 14-292761Fax: +49 5231 14-292761

Technical Contact

Weidmuller Interface GmbH & Co. KGMichael Piekarzewitz
[email protected]+49 5231 14

Zukunftsmeile 2 · Paderborn · Germany

Non-Technical Contact

Weidmuller Interface GmbH & Co. KGMichael Piekarzewitz
[email protected]+49 5231 14

Test Firm

UL International Germany GmbHBernd Woerl
[email protected]004971149002031Fax: -

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.70 mW
Confidentiality
Long Term
Grant Notes
Power is conducted. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with accepted multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.