Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
I SMARTGYM MA001 VersionV1.0.0 2023.03.16 Manufacturer:ShenzhenGymeraTechnologyCo.,LTD Address:13thFloor,XingfuchengCommercialBuilding,HepingEastRd,Longhua District,Shenzhen,China Thankyouforchoosingourproducts.Pleasereadthismanualcarefullybeforeuse. : Pleasereadthismanualcarefullybeforeusingtheproductandkeepitproperly.Theproduct, accessories,userinterfaceandotherillustrationsinthemanualareschematicdiagramsfor referenceonly.Duetotheupdateandupgradeoftheproduct,theactualproductandthe diagrammaybeslightlydifferent,pleaserefertotheactualproduct. ShenzhenGymeraTechnologyCo.,Ltd./E-mail:[email protected]/Website:www.gymeratech.com1 SafetyStatement ●Gymerafitnessequipmentutilizesspecifictechnology,anditsfeaturesand informationareintendedforreferencepurposesonly.Theyshouldnotreplace professionalmedicalandfitnessguidance.Priortofollowinganyfitnessplanor advicefromthisproduct,consultaqualifiedphysicianorfitnesstrainer. ●TheGymerasystemdoesnotguaranteethatauser'shealthorphysicalcondition isappropriateforspecificexercisesorfitnessprograms.Engaginginthefitness programsandsuggestionsprovidedbythisproductmayinvolverisks.Users mustassessandaccepttheserisksindependentlyandexercisecautionand attentivenessduringworkoutstopreventinjuriesorharm. ●ThefitnessdataandoutcomessuppliedbyGymeraserveasareferencefor usersandarenotabsolutelyaccurate.Duetoindividualdifferencesinphysical condition,exerciselevels,dietaryhabits,andotherfactors,thedataandtraining resultsfromGymerawillvary.Usersshouldevaluatethesuitabilityoffitness plansandrecommendationsontheirown,makingadjustmentsbasedontheir physicalconditionsandsensations. ●Gymeraequipmentisnotmeanttoreplacemedicalorfitnessadvicefroma physician,fitnesstrainer,orotherprofessionals.Ifusersexperiencephysical discomfortorhealthissues,theyshouldpromptlyconsultaqualifieddoctoror fitnesstrainerandfollowtheirrecommendations. ●Asitisnotfeasibletooutlineallpotentialrisksinthismanual,Gymeraassumes noresponsibilityforinjuries,productionloss,orindirectdamageresultingfrom incompleteinformation.Usersshouldassessriskswhileusingtheproduct. ShenzhenGymeraTechnologyCo.,Ltd./E-mail:[email protected]/Website:www.gymeratech.com2 ●Thiswarrantyexcludesfaultscausedbyimproperuseorfailuretoadhereto Gymera'sinstructions. SoftwareStatement ●Thepurchaserand/orenduserisgrantedanon-exclusiverighttousethe software,whichistheintellectualpropertyofShenzhenGymeraTechnologyCo., Ltd.,andisexclusivelyintendedforusewiththisproduct. ●Thebuyerand/orendusermayonlycreatecopiesofthesoftwareforpersonal backuppurposes. ●ShenzhenGymeraTechnologyCo.,Ltd.retainsallintellectualpropertyrightsto thesoftware,asstatedabove. ●ShenzhenGymeraTechnologyCo.,Ltd.isnotrequiredtoprovidethesoftware's sourcecode,asstatedabove. ●ShenzhenGymeraTechnologyCo.,Ltd.isresponsibleforprovidingcustomers withremotesoftwareupgradesorauthorizinganagentofShenzhenGymera TechnologyCo.,Ltd.tosupplyremotesoftwareupgradeservices,asstated above. ●Theownerisresponsibleforregularlybackingupallhardwareandsoftware components. ShenzhenGymeraTechnologyCo.,Ltd./E-mail:[email protected]/Website:www.gymeratech.com3 IntellectualPropertyStatement ●Thecopyrightforthismanualandanyaccompanyinginformationisheldby ShenzhenGymeraTechnologyCo.,Ltd.Theinformationprovidedinthismanual isintendedsolelyforinstallation,training,andservicepurposes. ●WithoutwrittenconsentfromShenzhenGymeraTechnologyCo.,Ltd.,itisstrictly prohibitedtoreuse,redesign,distribute,orotherwiseprocessanyportionofthis information,whetherinelectronicorwrittenform. ●Modificationstotheproduct,particularlythedevice,arenotallowedwithout explicitwrittenpermissionfromShenzhenGymeraTechnologyCo.,Ltd. ●Copyright©andTrademark®orTrademark™symbolsmustnotberemoved. Third-partytrademarksandotherintellectualpropertymaterialsbelongtotheir respectiveowners. ShenzhenGymeraTechnologyCo.,Ltd./E-mail:[email protected]/Website:www.gymeratech.com4 1.SafetyInstructions Forsafety,ensureaclear spacewithadiameterof3-4 meterssurroundingthe machineduringtraining sessions. Pleasedonotsteponthebase ofthemachine. Toavoidinstability,donot placethemachine onunevenground. Petsarestrictlyprohibitedfrom beinginthevicinityofthe machine. ShenzhenGymeraTechnologyCo.,Ltd./E-mail:[email protected]/Website:www.gymeratech.com5 Topreventinjuryordamage,do nothangfromthearmbar. Thepneumaticcomponents shouldnotbesubjectedtosevere blowsunderanycircumstances. Childrenmustbeaccompaniedby anadult.Donotleavechildren alonewiththemachine. Whenusingthefitnessmachine, thereisariskoffalling,especially forelderlyindividuals,children, andpregnantwomen.Please exercisecautionifyoufallunder anyofthesecategories. ShenzhenGymeraTechnologyCo.,Ltd./E-mail:[email protected]/Website:www.gymeratech.com6 Themachinemustbeunplugged whennotinuse. Themachinemustbeplugged intoagroundedoutlettoprevent theriskofelectricshock. Pleaseusenon-slipmatswhen training. Duringtheinstallation ofthefixingpedal,takecarenot topinchyourhands. ShenzhenGymera TechnologyCo., Ltd. /E-mail :[email protected]/ Website :www.gymeratech.com7 Th is equipmenthas been testedand found to complywith the limits for a Class B digital device,pursuantto part 15 of the FCC Rules.Theselimits are designedto providereasonableprotectionagainstharmfulinterferencein a residential installation.This equipmentgenerates,uses and can radiateradio frequency energyand, if not installedand used in accordancewith the instructions,may cause harmfulinterferenceto radio communications.However,there is no guaranteethat interferencewill not occur in a particularinstallation.If this equipmentdoes cause harmfulinterferenceto radio or televisionreception,which can be determinedby turningthe equipmentoff and on, the user is encouragedto try to correctthe interferenceby one or more of the followingmeasures: •Reorientor relocatethe receivingantenna. •Connectthe equipmentinto an outlet on a circuit differentfrom that to which the receiveris connected. •Consultthe dealeror an experiencedradio/TVtechnicianfor help. Caution:Any change…
Text truncated - open the document above for the full version.
Shenzhen Gymera Technology Co., Ltd Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 6/26/2023 U.S. Agent Designation Shenzhen Gymera Technology Co., Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BAMF-MR002): Name and company of U.S. agent: TianHeng Consulting, LLC Physical U.S. address of agent: 392 Andover Street, Wilmington, MA 01887, United States FRN of U.S. agent: 0033401258 Email address of U.S. agent: [email protected] TianHeng Consulting, LLC acknowledges their obligation to accept service of process on behalf of Shenzhen Gymera Technology Co., Ltd. Shenzhen Gymera Technology Co., Ltd with the FRN 0033559295 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Chuandou Liu Quality Engineer Shenzhen Gymera Technology Co., Ltd Signature Hualing Dong President TianHeng Consulting, LLC 48_[mo del] US_Agen t_2.911(d)(7) - U, V05
Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Shenzhen Gymera Technology Co., Ltd Address: 13th Floor, Xingfucheng Commercial Building, Heping East Rd, Longhua district, Shenzhen, China Phone: +86-755-23732305 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-06-26 Name / Title: Chuandou Liu / Quality Engineer Company: Shenzhen Gymera Technology Co., Ltd Address: 13th Floor, Xingfucheng Commercial Building, Heping East Rd, Longhua district, Shenzhen, China Phone: +86-755-23732305 Fax: +86-755-23732305 E-Mail: [email protected]
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BAMF-MR002 MR002 We, applicant Company Name: Shenzhen Gymera Technology Co., Ltd Address: 13th Floor, Xingfucheng Commercial Building, Heping East Rd, Longhua district, Shenzhen, China Phone: +86-755-23732305 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-06-26 Name / Title: Chuandou Liu / Quality Engineer Company: Shenzhen Gymera Technology Co., Ltd Address: 13th Floor, Xingfucheng Commercial Building, Heping East Rd, Longhua district, Shenzhen, China Phone: +86-755-23732305 Fax: +86-755-23732305 E-Mail: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BAMF-MR002 MR002 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-06-26 Name / Title: Chuandou Liu / Quality Engineer Company: Shenzhen Gymera Technology Co., Ltd Address: 13th Floor, Xingfucheng Commercial Building, Heping East Rd, Longhua district, Shenzhen, China Phone: +86-755-23732305 Fax: +86-755-23732305 E-Mail: [email protected]
Page1of3FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6
Page1of1FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L2.0cmx1.0cm) LabelLocation FCCID:2BAMF-MR002
Page1 of 4FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add: 101,201BldgA & 301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity InternalPhotosof theEUT Fig. 1 Fig. 2 Page2 of 4FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add: 101,201BldgA & 301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Fig. 3 Fig. 4 Page3 of 4FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add: 101,201BldgA & 301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Fig. 5 Fig. 6 Page4 of 4FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add: 101,201BldgA & 301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Fig. 7 Fig. 8 Antenna
Page1of3FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation FCCID:2BAMF-MR002 Productname:BluetoothController TestModel:MR002 Powersupply:DC1.5VbyAAABattery HardwareVersion:/ SoftwareVersion:/ BluetoothFrequencyRange:2402MHz~2480MHz ChannelNumber:40channelsforBluetoothV5.0(DTS) ChannelSpacing:2MHzforBluetoothV5.0(DTS) ModulationType:GFSKforBluetoothV5.0(DTS) BluetoothVersion:V5.0 AntennaDescription:PCBAntenna,-0.58dBi(Max.) Exposurecategory:Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:PortableDevice 2.EvaluationmethodandLimit AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSAR testexclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposureKDB procedures,standalone1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulation exposureconditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition,listedbelow,issatisfied.Thesetest exclusionconditionsarebasedonsource-basedtime-averagedmaximumconductedoutputpower oftheRFchannelrequiringevaluation,adjustedfortune-uptolerance,andtheminimumtest separationdistancerequiredfortheexposureconditions.22Theminimumtestseparationdistance isdeterminedbythesmallestdistancefromtheantennaandradiatingstructuresoroutersurfaceof thedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements,toany partofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSARtest exclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbythe operatingconfigurationsandexposureconditionsofthetransmitterandapplicablehostplatform requirements,typicallyintheSARmeasurementorSARanalysisreport,accordingtotherequired publishedRFexposureKDBprocedures.WhennootherRFexposuretestingorreportingis required,astatementofjustificationandcompliancemustbeincludedintheequipmentapproval,in lieuoftheSARreport,toqualifyfortheSARtestexclusion.Whenrequired,thedevicespecific conditionsdescribedintheotherpublishedRFexposureKDBproceduresmustbesatisfiedbefore applyingtheseSARtestexclusionprovisions;forexample,handheldPTTtwo-wayradios,handsets, laptops&tabletsetc.“ [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where: •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison •3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mm Page2of3FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmaccordingtof)insection4.1isappliedto determineSARtestexclusion. Whenoneofthefollowingtestexclusionconditionsissatisfiedforallcombinationsof simultaneoustransmissionconfigurations,furtherequipmentapprovalisnotrequiredto incorporatetransmittermodulesinhostdevicesthatoperateinthemixedmobileandportablehost platformexposureconditions.ThegranteeisresponsiblefordocumentingthisaccordingtoClassI permissivechangerequirements.AntennasthatqualifyforstandaloneSARtestexclusionmust applytheestimatedstandaloneSARtodeterminesimultaneoustransmissiontestexclusion. a)The[∑of(thehighestmeasuredorestimatedSARforeachstandaloneantennaconfiguration, adjustedformaximumtune-uptolerance)/1.6W/kg]+[∑ofMPEratios]is≤1.0. b)TheSARtopeaklocationseparationratiosofallsimultaneouslytransmittingantennapairs operatinginportabledeviceexposureconditionsareall≤0.04,andthe[∑ofMPEratios]is≤ 1.0. 3.ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01GeneralRFExposureGuidancev06:MobileandPortableDevices RFExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1093:Radiofrequencyradiationexposureevaluation:portabledevices Page3of3FCCID:2BAMF-MR002 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.ConductedPowerResults [BLE] ModeChannelFrequency(MHz) PeakConductedOutput Power(dBm) BLE1M 02402 -5.25 192440 -4.32 392480-3.92 BLE2M 02402 -5.31 192440 -4.37 392480 -3.98 5.ManufacturingTolerance [ BLE ] BLE1M(Peak) ChannelChannel0Channel19Channel39 Target(dBm)-5.0-4.0-3.0 Tolerance±(dB)1.01.01.0 BLE2M(Peak) ChannelChannel0Channel19Channel39 Target(dBm)-5.0-4.0-3.0 Tolerance±(dB)1.01.01.0 6.EvaluationResults 6.1StandaloneEvaluation [BLE] Mode Frequency (GHz) Antenna Distance (mm) RFoutput power SARTestExclusion Threshold SARTest Exclusion dBmmW BLE1M2.4805-2.00.63100.1987<3.0Yes BLE2M2.4805-2.00.63100.1987<3.0Yes Remark: 1.Outputpowerincludingtuneuptolerance; 2.Whentheminimumtestseparationdistanceis<5mm,adistanceof5mmaccordingtof)insection 4.1isappliedtodetermineSARtestexclusion. 6.2SimultaneousTransmissionforSARExclusion ThesamplesupportoneBTmodular.Noneedconsidersimultaneoustransmission. 7.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRF ExposureandSARExclusionThresholdperKDB447498v06. ----------------THEENDOFREPORT---------------
Summary Inverted F Antenna Specification ITEMANT SPEC Model Name2.4G ANT Center Frequency HorizontalVertical 2400MHz 2400MHz 2500MHz 2400MHz 2400MHz 2500MHz -1.26-0.76-0.58-5.25-2.46-1.86 MAX. Gain-0.58dB PolarizationHorizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance50 Ohm Antenna Length36.70mm Manufacture Shenzhen Gymera Technology Co., Ltd Antenna Photo & Length (mm) Horizontal:2400MHz2450MHz2500MHz Power(dBm) Max:0Min:-40Scale:5/div Frequency (MHz) Gain(dB) MaxMinAvg 2400-1.26174-30.0801-7.18716 2450-0.765802-36.5604-7.48023 2500-0.585582-22.0315-6.59127 Vertical:2400MHz2450MHz2500MHz Power(dBm) Max:0Min:-30Scale:5/div Frequency (MHz) Gain(dB) MaxMinAvg 2400-5.2537-22.1424-12.4294 2450-2.4652-24.5837-10.4702 2500-1.86120-29.5214-9.20432 ANTTestLabs:AttestationofGlobalComplianceCo.,Ltd.
Page1 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity RF Test Data for BLE (ConductedMeasurement) ProductName:BluetoothController Test Model:MR002 EnvironmentalConditions Temperature: 23.8 C RelativeHumidity:52.1% ATM Pressure:10 0.0 kPa Test Engineer:JokerHu Supervisedby:Ling Zhu Page2 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity A.1 -6dB Bandwidth ConditionModeFrequency(MHz)Antenna-6 dB Bandwidth(MHz)Limit -6 dB Bandwidth(MHz)Verdict NVNTBLE 1M2402Ant10.652>=0.5Pass NVNTBLE 1M2440Ant10.65>=0.5Pass NVNTBLE 1M2480Ant10.683>=0.5Pass NVNTBLE 2M2402Ant11.14>=0.5Pass NVNTBLE 2M2440Ant11.14>=0.5Pass NVNTBLE 2M2480Ant11.135>=0.5Pass Page3 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs -6dBBandwidthNVNTBLE 1M 2402MHzAnt1 -6dBBandwidthNVNTBLE 1M 2440MHzAnt1 Page4 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTBLE 1M 2480MHzAnt1 -6dBBandwidthNVNTBLE 2M 2402MHzAnt1 Page5 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity -6dBBandwidthNVNTBLE 2M 2440MHzAnt1 -6dBBandwidthNVNTBLE 2M 2480MHzAnt1 Page6 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity A.2 MaximumConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit (dBm)Verdict NVNTBLE 1M2402Ant1-5.2530Pass NVNTBLE 1M2440Ant1-4.3230Pass NVNTBLE 1M2480Ant1-3.9230Pass NVNTBLE 2M2402Ant1-5.3130Pass NVNTBLE 2M2440Ant1-4.3730Pass NVNTBLE 2M2480Ant1-3.9830Pass Page7 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs PowerNVNTBLE 1M 2402MHzAnt1 PowerNVNTBLE 1M 2440MHzAnt1 Page8 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PowerNVNTBLE 1M 2480MHzAnt1 PowerNVNTBLE 2M 2402MHzAnt1 Page9 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PowerNVNTBLE 2M 2440MHzAnt1 PowerNVNTBLE 2M 2480MHzAnt1 Page10 of 34FCCID: 2BAMF-MR002ReportNo. : LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity A.3 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) Duty Factor (dB) Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE 1M2402Ant1-21.490-21.498Pass NVNTBLE 1M2440Ant1-20.710-20.718Pass NVNTBLE 1M2480Ant1-20.140-20.148Pass NVNTBLE 2M2402Ant1-24.150-24.158Pass NVNTBLE 2M2440Ant1-23.110-23.118Pass NVNTBLE 2M2480Ant1-22.710-22.718Pass Page11 of 34FCCID: 2BAMF-MR002ReportNo.: LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity Test Graphs PSD NVNTBLE 1M 2402MHzAnt1 PSD NVNTBLE 1M 2440MHzAnt1 Page12 of 34FCCID: 2BAMF-MR002ReportNo. : LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PSD NVNTBLE 1M 2480MHzAnt1 PSD NVNTBLE 2M 2402MHzAnt1 Page13 of 34FCCID: 2BAMF-MR002ReportNo. : LCSA031423024EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86)0755-82591330| E-mail:[email protected]| Web:www.lcs-cert.com Scancodeto checkauthenticity PSD NVNTBLE 2M 2…
Text truncated - open the document above for the full version.
Page1of32FCCID:2BAMF-MR002ReportNo.:LCSA031423024EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For ShenzhenGymeraTechnologyCo.,Ltd BluetoothController TestModel:MR002 Preparedfor:ShenzhenGymeraTechnologyCo.,Ltd Address:13thFloor,XingfuchengCommercialBuilding,HepingEastRd, Longhuadistrict,Shenzhen,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:March25,2023 Numberoftestedsamples:2 SampleNo.:A031423024-1,A031423024-2 Serialnumber:Prototype DateofTest:March25,2023~May09,2023 DateofReport:May10,2023 Page2of32FCCID:2BAMF-MR002ReportNo.:LCSA031423024EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA031423024EA DateofIssue.......................................:May10,2023 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ShenzhenGymeraTechnologyCo.,Ltd Address................................................:13thFloor,XingfuchengCommercialBuilding,HepingEastRd, Longhuadistrict,Shenzhen,China TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo......................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:BluetoothController TradeMark..........................................: TestModel...........................................:MR002 Ratings.................................................:DC1.5VbyAAABattery Result...................................................:Positive Compiledby:Supervisedby:Approvedby: DiamondLu/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page3of32FCCID:2BAMF-MR002ReportNo.:LCSA031423024EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 410.00 µW |

Smart Gym
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Smart Handles
Equipment Class
DTS - Digital Transmission System