Mytech Intelligence(Shenzhen) Co.,Ltd
Palmtop Ultrasound Diagnostic System - FCC ID 2BANFMT10-MT10P - Mytech Intelligence(Shenzhen) Co.,Ltd
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 15, 2023
Application Purpose
Original Equipment
Date of Application
Jul 15, 2023
Equipment Note
Palmtop Ultrasound Diagnostic System
Frequency Range
5745.00000000 - 5825.00000000
Company
Mytech Intelligence(Shenzhen) Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Part No. MTI-RD-FDA-011 Palmtop Ultrasound Diagnostic System MT10P/MT10 User manual (V2) Mytech Intelligence(ShenZhen)Co., Ltd. Manufacturer’s Address Mytch Intelligence(Shenzhen)Co., Ltd. Room604, 605, 615 & 616, Block R3-B, Virtual University Park, No. 018, South 7th Gaoxin Road, Gaoxin Community, Yuehai Street, Nanshan District, Shenzhen, China Product information page Product name: Palmtop Ultrasound Diagnostic System Product modle: MT10P、MT10 Product waterproof Rate: The protection class of the whole machine is IPX5 The protection class of the probe is IPX7 Production date: In Hand-held ultrasonic diagnostic instrument Product life 5years Power Requirments: Battery Nominal Voltage DC3.85V; Input Voltage DC5V; Power input: 5 VA The software edition: V1 Registrant&production enterprise: Mytech Intelligence(ShenZhen)Co.,Ltd. Address: Room604, 605, 615 & 616, Block R3-B, Virtual University Park, No. 018, South 7th Gaoxin Road, Gaoxin Community, Yuehai Street, Nanshan District, Shenzhen Production address: Room604, 605, 615 & 616, Block R3-B, Virtual University Park, No. 018, South 7th Gaoxin Road, Gaoxin Community, Yuehai Street, Nanshan District, Shenzhen Production license no. : Postal code: 518000 Phone code: Fax: Email: After-sales service unit: Mytech Intelligence(ShenZhen)Co.,Ltd. Address: Room604, 605, 615 & 616, Block R3-B, Virtual University Park, No. 018, South 7th Gaoxin Road, Gaoxin Community, Yuehai Street, Nanshan District, Shenzhen Post code: 518000 Phone code: Mytech Intelligence(ShenZhen)Co., Ltd. has the final interpretation of this instruction manual. Intended Use Palmtop Ultrasound Diagnostic is intended for clinical ultrasound diagnosis. User responsibility The user is responsible for ensuring that meets the following conditions: 1. Any person operating the device shall read and understand the entire contents of this user manual and other attached documents. 2. Any person who operates the device shall be authorized and shall be fully qualified after strict training. Warning 1. Please read this manual carefully before using this devicedevice. 2. This manual is only used as a reference for operation, repair and maintenance of the device. 3. Only qualified medical personnel can operate the device. 4. Only images approved by qualified medical personnel can be used for clinical diagnosis. 5. The acoustic power level described in this specification shall be below the maximum allowable value. 6. Do not use too high a power level, although regular ultrasound testing will not cause side effects. 7. Do not place or use flammable, explosive or combustible materials around the main engine. 8. Do not place any liquid material around the device. 9. Liquid immersion should be prevented during device disinfection/sterilization. 10. The maintenance of the device must be carried out by personnel approved by Mytech Intelligence (ShenZhen)Co., Ltd.. 11. Do not modify the device. User modification will lead to safety hazards and degrade system performance. The system modification must be completed by a staff approved by the company. 12. To ensure the accuracy of the user's use of this manual, the contents in this manual can be modified and updated without prior notice to the user based on software upgrades and new clinical findings. 13. Only qualified personnel could login and operate the software following to the instructions, so as to protect the product from being attacked by virus. FCC Compliance Statements This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. RF Exposure Compliance This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End user must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The portable device is designed to meet the requirements for exposure to radio waves established by the FCC. These requirements set a SAR limit of 4 W/kg averaged over 10 gram of tissue. The highest SAR value reported under this standard during product certification for use when properly worn on the extremity, with 0mm separation. Intellectual property 1.Mytech Intelligence(ShenZhen)Co., Ltd. owns the intellectual copyright of all hardware, software and documents of the device. 2.Without permission, any unit, individual or institution shall not copy or copy any part of this manual in any form or by any means. 3.This manual is only used to operate and maintain the system. Mytech…

Text truncated - open the document above for the full version.

Cover Letter(s)

Software Security Description 180

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 1 of 4 External Photos for SZCR2303000551ME FCC ID: 2BANFMT10-MT10P SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 2 of 4 EUT Constructional Details (EUT Photos) Label Location SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 4 of 4

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 1 of 6 Appendix D for SZCR230300055104 Photographs 1. SAR measurement System 2. Photographs of Tissue Simulate Liquid 3. Photographs of EUT test position 4. EUT Antenna Locations 5. EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 2 of 6 1. SAR measurement System SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 3 of 6 2. Photographs of Tissue Simulate Liquid Tissue Simulant Liquid for Head 2450 Tissue Simulant Liquid for Head 5GHz SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 4 of 6 3. Photographs of EUT test position Front 0mm Left 0mm Back side 0mm SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 5 of 6 4. EUT Antenna Locations SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 6 of 6 5. EUT Constructional Details Details please Refer to Appendix – Photographs of EUT Constructional Details for SZCR2303000551ME.

ID Label/Location Info

MT10丝印图-EN 蓝色为潘通 蓝色为潘通 黑字

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 1 of 5 Internal Photos for SZCR2303000551ME FCC ID: 2BANFMT10-MT10P SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 2 of 5 EUT Constructional Details (EUT Photos) Antenna SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 3 of 5 Wireless charging Rx coil SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 4 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 5 of 5 - End of the Appendix -

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Report No.: SZCR230300055104 Page: 1 of 57 Keny Xu EMC Laboratory Manager FCC SAR TEST REPORT Application No.: SZCR2303000551ME Applicant: Mytech Intelligence(Shenzhen) Co., Ltd Address of Applicant: Room 604, 605, 615 & 616, Block R3-B, Virtual University Park, Nanshan District, Shenzhen, China Manufacturer: Mytech Intelligence(Shenzhen) Co., Ltd Address of Manufacturer: Room 604, 605, 615 & 616, Block R3-B, High-tech industrial village, No. 018, South 7th Gaoxin Road, Gaoxin Community, Yuehai Street, Nanshan District, Shenzhen, China Factory: Mytech Intelligence(Shenzhen) Co., Ltd Address of Factory: Room 604, 605, 615 & 616, Block R3-B, High-tech industrial village, No. 018, South 7th Gaoxin Road, Gaoxin Community, Yuehai Street, Nanshan District, Shenzhen, China Product Name: Palmtop Ultrasound Diagnostic System Model No.(EUT): MT10, MT10P   Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: 2BANFMT10-MT10P Standard(s) : FCC 47CFR §2.1093 Date of Receipt: 2023-05-26 Date of Test: 2023-05-27 to 2023-05-30 Date of Issue: 2023-06-08 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Report No.: SZCR230300055104 Page: 2 of 57 REVISION HISTORY Revision Record Version Description Date Remark 00 Original 2023-06-08 / Authorized for issue by: Owen. Xiao/ Project Engineer Eric. Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Report No.: SZCR230300055104 Page: 3 of 57 TEST SUMMARY Frequency Band Maximum Reported SAR(W/kg) Extremity WI-FI (2.4GHz) 0.1 WI-FI (5GHz) 0.48 SAR Limited(W/kg) 4 Note: Palmtop Ultrasound Diagnostic System and its below model (s) / item(s): MT10, MT10P Only the model MT10 was tested, since according to the declaration from the applicant, the electrical circuit design, PCB layout, components used and internal wiring and functions were identical for the above models, with only difference on model No.. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Report No.: SZCR230300055104 Page: 4 of 57 CONTENTS 1 GENERAL INFORMATION .............................................................................................................................. 6 1.1 GENERAL DESCRIPTION OF EUT .................................................................................................................. 6 1.2 DUT ANTENNA LOCATIONS .......................................................................................................................... 7 1.3 TEST SPECIFICATION ................................................................................................................................... 8 1.4 RF EXPOSURE LIMITS .................................................................................................................................. 9 1.5 TEST LOCATION ........................................................................................................................................ 10 1.6 TEST FACILITY .......................................................................................................................................... 10 2 LABORATORY ENVIRONMENT ................................................................................................................... 11 3 SAR MEASUREMENTS SYSTEM CONFIGURATION .................................................................................. 12 3.1 THE SAR MEASUREMENT SYSTEM ............................................................................................................ 12 3.2 ISOTROPIC E-FIELD PROBE EX3DV4 ......................................................................................................... 14 3.3 DATA ACQUISITION ELECTRONICS (DAE) ................................................................................................... 15 3.4 SAM TWIN PHANTOM ................................................................................................................................ 15 3.5 ELI PHANTOM ........................................................................................................................................... 16 3.6 DEVICE HOLDER FOR TRANSMITTERS ......................................................................................................... 17 3.7 MEASUREMENT PROCEDURE ...................................................................................................................... 18 3.7.1 Scanning procedure ........................................................................................................................... 18 3.7.2 Data Storage ...................................................................................................................................... 20 3.7.3 Data Evaluation by SEMCAD ............................................................................................................. 20 4 SAR MEASUREMENT VARIABILITY AND UNCERTAINTY ........................................................................ 22 4.1 SAR MEASUREMENT VARIABILITY ............................................................................................................... 22 4.2 SAR MEASUREMENT UNCERTAINTY ............................................................................................................ 23 5 DESCRIPTION OF TEST POSITION ............................................................................................................. 24 5.1 THE TEST POSITION .................................................................................................................................. 24 6 SAR SYSTEM VERIFICATION PROCEDURE .....................…

Text truncated - open the document above for the full version.

Test Report

2.4 / 5GHz Multilayer Monopole Antenna ( for W-LAN ) AH 104N2450D1 (2.4GHz band) Actual data L= 10.0 ± 0.3 mm * Wide Band Efficiency : -1.3dB ( 73%) W= 4.0 ± 0.3 mm * High Performance Peak Gain : 2.1dBi T= 1.0 ± 0.3 mm Average Gain : 0.3dBi (ZX plane-Vertical polarization) 2400MHz 2450MHz 2500MHz Efficiency [dB] -1.4 -1.3 -1.2 ( 72%) ( 73%) ( 76%) Peak gain [dBi] 1.7 2.1 1.4 Average XY-plane TX-H - 2.6 -2.5 -2.5 gain TX-V - 29.5 -29.0 -29.1 [dBi] YZ-plane TX-H - 2.4 -2.5 -2.5 TX-V - 15.1 -15.1 -15.3 ZX-plane TX-H - 17.1 -17.0 -16.8 TX-V 0 .3 0.3 0.5 XY-plane YZ-plane ZX-plane @2450MHz (-X) (+Z) (+Z) (-Y) (+Y) (-Y) (+Y) (+X) (-X) unit: dBi (+X) (-Z) (-Z) @2450MHz -45-35-25-15 -5 5 TX-HTX-V +Y +X +Z +Y +X +Z +Y +X +Z -45-35-25-15 -5 5 TX-HTX-V -45-35-25-15 -5 5 TX-HTX-V ■ ■■■ Shapes ■ ■■■ Feature ■ ■■■ VSWR ■ ■■■ Radiation Pattern ■ ■■■ Electrical Characteristics *on Taiyo Yuden’s Evaluation Board ( 54 x 12 mm ) *Element-GND Distance : 1.5 mm Bandwidth: 500MHz (VSWR<2) 11 97531 10 86421950 2450 MHz 2950 The data is reference only. Electrical characteristics vary depending on environment or measurement condition.TAIYO YUDEN reserves the right to make change to the Date at any time without notice.Before making final selection, please check product specification Date: Sep/01/2011 manufacturer: TAIYO YUDEN CO., LTD.Address:Kyobashi East Bldg., 2-7-19, Kyobashi, Chuo-ku, Tokyo 104-0031, Japan 2.4 / 5GHz Multilayer Monopole Antenna ( for W-LAN ) AH 104N2450D1 (5GHz band) Actual data L= 10.0 ± 0.3 mm * Wide Band Efficiency : -1.6dB ( 69%) W= 4.0 ± 0.3 mm * High Performance Peak Gain : 2.4dBi T= 1.0 ± 0.3 mm 4900MHz 5250MHz 5900MHz Efficiency [dB] -2.0 -1.6 -2.0 ( 64%) ( 69%) ( 64%) Peak gain [dBi] 2.2 2.4 2.4 Average XY-plane TX-H - 3.2 -3.1 -3.2 gain TX-V - 25.4 -24.6 -22.7 [dBi] YZ-plane TX-H - 3.0 -2.6 -3.0 TX-V - 7.7 -8.2 -8.8 ZX-plane TX-H - 10.9 -10.8 -12.3 TX-V - 12.0 -10.6 -6.3 XY-plane YZ-plane ZX-plane @5250MHz (-X) (+Z) (+Z) (-Y) (+Y) (-Y) (+Y) (+X) (-X) unit: dBi (+X) (-Z) (-Z) @5250MHz -45-35-25-15 -5 5 TX-HTX-V +Y +X +Z +Y +X +Z +Y +X +Z -45-35-25-15 -5 5 TX-HTX-V -45-35-25-15 -5 5 TX-HTX-V ■ ■■■ Shapes ■ ■■■ Feature ■ ■■■ VSWR ■ ■■■ Radiation Pattern ■ ■■■ Electrical Characteristics *on Taiyo Yuden’s Evaluation Board ( 54 x 12 mm ) *Element-GND Distance : 1.5 mm Bandwidth: 1200MHz (VSWR<2) 11 97531 10 86424900 5400 MHz 5900 The data is reference only. Electrical characteristics vary depending on environment or measurement condition.TAIYO YUDEN reserves the right to make change to the Date at any time without notice.Before making final selection, please check product specification Date: Sep/01/2011 manufacturer: TAIYO YUDEN CO., LTD.Address:Kyobashi East Bldg., 2-7-19, Kyobashi, Chuo-ku, Tokyo 104-0031, Japan

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 1 of 27 Appendix C for SZCR230300055104 Calibration certificate 1. Dipole D2450V2 - SN 955(2022/06/06) D5GHzV2 - SN 1042(2022/06/01) 2. DAE DAE4 - SN 760(2022/06/06) 3. Probe EX3DV4 - SN 3836 (2022/06/27) SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 2 of 27 1. Dipole D2450V2 - SN 955 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 3 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 4 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 5 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 6 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 7 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 8 of 27 D5GHzV2 - SN 1042 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 9 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 10 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 11 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 12 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 13 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 14 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 15 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 16 of 27 2. DAE4 - SN 760 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 17 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 18 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 19 of 27 3. EX3DV4 - SN 3836 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 20 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 21 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 22 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 23 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 24 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 25 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 26 of 27 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/0 May15,2023 Page: 27 of 27

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 1 of 218 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2303000551ME Applicant: Mytech Intelligence(Shenzhen) Co., Ltd Address of Applicant: Room 604, 605, 615 & 616, Block R3-B, Virtual University Park, Nanshan District, Shenzhen, China Manufacturer: Mytech Intelligence(Shenzhen) Co., Ltd Address of Manufacturer: Room 604, 605, 615 & 616, Block R3-B, High-tech industrial village, No. 018, South 7th Gaoxin Road, Gaoxin Community, Yuehai Street, Nanshan District, Shenzhen, China Factory: Mytech Intelligence(Shenzhen) Co., Ltd Address of Factory: Room 604, 605, 615 & 616, Block R3-B, High-tech industrial village, No. 018, South 7th Gaoxin Road, Gaoxin Community, Yuehai Street, Nanshan District, Shenzhen, China Equipment Under Test (EUT): EUT Name: Palmtop Ultrasound Diagnostic System Model No.: MT10, MT10P   Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: 2BANFMT10-MT10P Standard(s) : 47 CFR Part 15, Subpart E 15.407 Date of Receipt: 2023-03-29 Date of Test: 2023-04-22 to 2023-05-26 Date of Issue: 2023-06-06 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 2 of 218 Revision Record Version Chapter Date Modifier Remark 01 2023-06-06 Original Authorized for issue by: Edison Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 3 of 218 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart E 15.407 N/A 47 CFR Part 15, Subpart C 15.203 Pass Transmission in the Absence of Data N/A 47 CFR Part 15, Subpart E 15.407 (c) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart E 15.407 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 & Subpart E 15.407 b(9) Pass Duty Cycle KDB 789033 II B 1 KDB 789033 D02 II B 1 Pass 99% Bandwidth KDB 789033 II D N/A Pass 26dB Emission bandwidth KDB 789033 D02 II C 1 47 CFR Part 15, Subpart E 15.407 (a) Pass Minimum 6 dB bandwidth (5.725- 5.85 GHz band ) KDB 789033 D02 II C 2 47 CFR Part 15, Subpart E 15.407 (e) Pass Maximum Conducted output power KDB 789033 D02 II E 47 CFR Part 15, Subpart E 15.407 (a) Pass Peak Power spectrum density KDB 789033 D02 II F 47 CFR Part 15, Subpart E 15.407 (a) Pass Radiated Emissions which fall in the restricted bands KDB 789033 D02 II G 47 CFR Part 15, Subpart C 15.209 & Subpart E 15.407(b) Pass Radiated Emissions (Below 1GHz) KDB 789033 D02 II G 47 CFR Part 15, Subpart C 15.209 & Subpart E 15.407(b) Pass Radiated Emissions (Above 1GHz) KDB 789033 D02 II G 47 CFR Part 15, Subpart C 15.209 & Subpart E 15.407(b) Pass Frequency Stability ANSI C63.10 (2013) Section 6.8 47 CFR Part 15, Subpart E 15.407 (g) Pass Non-occupancy period KDB 905462 D02 Section 7.8.3 KDB 905462 D02 Section 5.1 Pass Channel Move Time KDB 905462 D02 Section 7.8.3 KDB 905462 D02 Section 5.1 Pass Channel Closing Transmission Time KDB 905462 D02 Section 7.8.3 KDB 905462 D02 Section 5.1 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 4 of 218 Declaration of EUT Family Grouping: Model No.: MT10, MT10P Only the model MT10 was tested, since according to the declaration from the applicant, the electrical circuit design, PCB layout, components used and internal wiring and functions were identical for the above models, with only difference on model No.. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 5 of 218 3 Contents Page 1 Cover Page ................................................................................................................................................ 1 2 Test Summary ........................................................................................................................................... 3 3 Contents .................................................................................................................................................... 5 4 General Information .................................................................................................................................. 8 4.1 Details of E.U.T. ................................................................................................................................. 8 4.2 Description of Support Units .............................................................................................................. 8 4.3 Measurement Uncertainty .................................................................................................................. 9 4.4 Test Location .................................................................................................................................... 10 4.5 Test Facility ...................................................................................................................................... 10 4.6 Deviation from Standards ................................................................................................................. 10 4.7 Abnormalities from Standard Conditions ......................................................................................... 10 5 Equipment List ........................................................................................................................................ 11 6 Radio Spectrum Technical Requirement ...................................…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 168 of 218 2. Bandwidth 2.1 OBW 2.1.1 Test Result Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result 802.11a SISO 5180 1 18.520 Pass 5200 1 18.464 Pass 5240 1 18.536 Pass 5260 1 18.375 Pass 5300 1 18.362 Pass 5320 1 18.312 Pass 5500 1 18.274 Pass 5580 1 18.331 Pass 5700 1 18.283 Pass 5745 1 18.506 Pass 5785 1 18.561 Pass 5825 1 18.554 Pass 802.11n (HT20) SISO 5180 1 19.472 Pass 5200 1 19.314 Pass 5240 1 19.279 Pass 5260 1 19.219 Pass 5300 1 19.188 Pass 5320 1 19.298 Pass 5500 1 19.143 Pass 5580 1 19.173 Pass 5700 1 19.131 Pass 5745 1 19.379 Pass 5785 1 19.367 Pass 5825 1 19.347 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 169 of 218 2.1.2 Test Graph 802.11a_LCH_5180MHz_Ant1_NTNV 802.11a_MCH_5200MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 170 of 218 802.11a_HCH_5240MHz_Ant1_NTNV 802.11a_LCH_5260MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 171 of 218 802.11a_MCH_5300MHz_Ant1_NTNV 802.11a_HCH_5320MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 172 of 218 802.11a_LCH_5500MHz_Ant1_NTNV 802.11a_MCH_5580MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 173 of 218 802.11a_HCH_5700MHz_Ant1_NTNV 802.11a_LCH_5745MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 174 of 218 802.11a_MCH_5785MHz_Ant1_NTNV 802.11a_HCH_5825MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 175 of 218 802.11n(HT20)_LCH_5180MHz_Ant1_NTNV 802.11n(HT20)_MCH_5200MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 176 of 218 802.11n(HT20)_HCH_5240MHz_Ant1_NTNV 802.11n(HT20)_LCH_5260MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 177 of 218 802.11n(HT20)_MCH_5300MHz_Ant1_NTNV 802.11n(HT20)_HCH_5320MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 178 of 218 802.11n(HT20)_LCH_5500MHz_Ant1_NTNV 802.11n(HT20)_MCH_5580MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 179 of 218 802.11n(HT20)_HCH_5700MHz_Ant1_NTNV 802.11n(HT20)_LCH_5745MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 180 of 218 802.11n(HT20)_MCH_5785MHz_Ant1_NTNV 802.11n(HT20)_HCH_5825MHz_Ant1_NTNV SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230300055103 Page: 181 of 218 2.2 6dB BW 2.2.1 Test Result Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz)…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Will Shi
[email protected]008617721449420Fax: +86-755-86545139

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]+8675525328629

No.1 Workshop, M-10, Middle Section, · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]+8675525328629

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd. ShKeny Xu
[email protected]+86 (0)755 2532 8629

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.83 GHz30.30 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. Device is an 802.11a/n device enabled for 5 GHz band operations as described in this filing. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. SAR compliance for extremity operating conditions is limited to the specific configurations tested for this filing. End-users must be informed of the extremity requirements to satisfy RF exposure compliance. The highest reported SAR for extremity exposure conditions is Wi-Fi(5G): 0.48W/kg. This device supports 20MHz bandwidth mode only. SAR testing was performed to demonstrate RF compliance.