FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. AirSuite Limited/
  3. 2BAOD-1420

2BAOD-1420AirSuite Glance LTE

AirSuite Limited
AirSuite Glance LTE - FCC ID 2BAOD-1420 - AirSuite Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 30, 2023
Application Purpose
Original Equipment
Date of Application
May 30, 2023
Equipment Note
AirSuite Glance LTE
Frequency Range
2402.00000000 - 2480.00000000
Company
AirSuite Limited
Country
New Zealand

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Getting started guide Indoor. Outcomes. connected ASCM1420 AirSuite Glance LTE 2 Getting started guideIirouite. GOance m2C Contents Introduction What’s in the box? Your sensor Before you start Installation Deployment Usage information Safety & compliance 3 4 5 – 6 7 8 – 9 10 – 11 12 – 13 14 – 15 3 Getting started guideIirouite. GOance m2C Introduction AirSuite ™ Sensors are a range of intelligent devices designed to monitor indoor environmental conditions. Each device is packed with a powerful array of sensors that monitor all important environmental factors including thermal comfort, ventilation, lighting, and acoustics. AirSuite ™ Sensors have a wireless connection to the Internet and provide a live feed of sensor data securely into the AirSuite ™ Monitor Portal and to the AirSuite ™ Monitor App. This AirSuite ™ sensor is battery-powered, and connects to the Internet over the Spark mobile network for Internet of Things (IoT) devices. The network uses LTE Cat-M1 technology and runs over Spark’s 4G mobile network. This network allows this sensor to operate in an ultra low-power mode, meaning its battery should last for up to 5 years, depending on the configured reporting frequency. AirSuite ™ sensors with LTE are especially suitable for: • Rapid deployment for large numbers of sensors • No-cable deployments, and deployment in locations where it would be difficult to connect to a power supply • Deployment in buildings without a secure Wi-Fi network for IoT devices • Temporary deployments Check the network connection at your intended deployment location here: www.spark.co.nz/coverage 4 Getting started guideIirouite. GOance m2C Included are enough accessories to support a variety of installation scenarios. It is recommended that you select the mounting solution that best suits your intended installation location. Command adhesive strips (B) can be used as an alternative to mounting with screws. Hollow wall anchor screws (D) can be used for mounting on plasterboard. Mounting bracket 4x mounting bracket screws 2x Command adhesive strips 4x hollow wall anchor screws A. C. B. D. What’s in the box? 5 Getting started guideIirouite. GOance m2C LED indicator, Light Sensor Your sensor — Front The latest sensor readings 6 Getting started guideIirouite. GOance m2C Reset button Micro-USB port for optional mains power Serial number & barcode will appear here Air intake Your sensor — Back 7 Getting started guideIirouite. GOance m2C • We recommend installing on the wall at a height of 1.5m to 1.8m from the ground, so that it has a good view of the room. • Avoid positioning facing windows, where it would be exposed to direct sunlight, as this will affect temperature and light level measurements. • Avoid positioning too close to where people will be using the space, as this could affect carbon dioxide level measurements. • Avoid placing near a stove or kettle, as this may affect temperature and humidity measurements. Optimal height install range 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 Height (metres) Before you start 8 Getting started guideIirouite. GOance m2C 1. Locate the mounting kit (A) included in the box. 2. Determine the best way to mount the bracket to your chosen surface. In this example, we are mounting to a wooden board, so screws (C) are used to install the bracket permanently. For a temporary installation, substitute the screws for the two Command adhesive strips (B). 3. Mount the bracket to the wall. The “wings” of the mounting bracket should sit level across the wall as shown in Figure 1. This ensures that the sensor sits plumb. 4. With the bracket installed on the wall, it is time to turn your sensor on. With a ball-point pen or the end of a paperclip, press and hold down the reset button for 2 seconds until the LED illuminates solid green in the Indicator LED window. 5. The LED will flash green once every second to indicate that the sensor is connecting to the mobile network. This could take up to 5 minutes. When it successfully connects, the LED will illuminate solid green briefly. 6. To confirm that the sensor has connected successfully, press the reset button once. The LED will flash green twice to indicate it is connected. Figure 1: The mounting bracket secured to a wall. The dashed lines illustrate how the “wings” on either side are horizontally level. Continued on the following page Installation 9 7. Place the sensor on the wall mount at an angle, then rotate it clockwise until it clicks into place. 8. The sensor is now reporting to the Cloud. To set its name and location, you can either sign in to the AirSuite ™ Monitor Portal, or follow the instructions on the next page to create a new deployment for the sensor using the AirSuite™ Monitor app. Indoor. Outcomes. Installation continued 10 Getting started guideIirouite. GOance m2C After physically installing your sensor, you can set its name and location (which will appear in the Portal) using the mobile app as follows: 1. Scan the QR code, or visit the link provided in Figure 2 to download and install the AirSuite ™ Monitor App. 2. Open the app and accept the prompts to enable the required permissions for Bluetooth and Location access. 3. The app will automatically scan for nearby devices. When it finds the device you are setting up, select it from the list. 4. Press the “Setup” button to start the deployment process. 5. Enter the password provided to you by AirSuite ™ or your organisation. If your organisation has not chosen a password, it may be set to “password” by default. Figure 2: Scan the QR code above to download the AirSuite ™ Monitor App, or visit app.airsuite.com Download the app Deployment Continued on the following page 11 6. Enter a descriptive name for the deployment. For deployments across a large number of rooms and buildings, we recommend that your organisation uses a consistent naming scheme so that deployments are easy to identify later for management purposes. 7. Press “Fi…

Text truncated - open the document above for the full version.

Attestation Statements

AirSuite Limited 3 Melody Lane, Hamilton East, Hamilton 3216 New Zealand The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-05-23 To whom it may concern: We, AirSuite Limited, hereby certify that the equipment for which authorization is sought FCC ID: 2BAOD-1420 is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). Sincerely, Signature Sam Mathews CTO AirSuite Limited 62_[model] CoveredEqu_2.911(d )(5)(i) and (ii) - U, V02

Attestation Statements

AirSuite Limited 3 Melody Lane, Hamilton East, Hamilton 3216 New Zealand The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 5/23/2023 U.S. Agent Designation AirSuite Limited acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2BAOD-1420 Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of AirSuite Limited. AirSuite Limited with the FRN 0033578162 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature Sam Mathews CTO AirSuite Limited Signature Tim Payne FCC US Agent, LLC 48_[mo del] US_Agent_2.911(d)(7) - U, V04

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2023-05-23> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BAOD-1420 ASCM1420 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Sam Mathews/CTO Company: AirSuite Limited Address: 3 Melody Lane, Hamilton East, Hamilton 3216 New Zealand Phone: +64 27 225 8082 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

AirSuite Limited 3 Melody Lane, Hamilton East, Hamilton 3216 New Zealand Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-05-23 To whom it may concern: We, AirSuite Limited the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BAOD-1420 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Sam Mathews/CTO Company: AirSuite Limited Address: 3 Melody Lane, Hamilton East, Hamilton 3216 New Zealand Phone: +64 27 225 8082 Fax: N/A E-Mail: [email protected]

External Photos

FCC ID:2BAOD-1420 TB-RF-074-1.0 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of EUT FCC ID:2BAOD-1420 TB-RF-074-1.0 Photo 3 Appearance of EUT Photo 4 Appearance of EUT FCC ID:2BAOD-1420 TB-RF-074-1.0 Photo 5 Appearance of EUT Photo 6 Appearance of EUT FCC ID:2BAOD-1420 TB-RF-074-1.0 Photo 7 Appearance of EUT Photo 8 Appearance of EUT

ID Label/Location Info

FCC ID:2BAOD-1420 TB-RF-074-1.0 Appendix IFCC ID Label AirSuite Glance LTE FCC ID: 2BAOD-1420 Model: ASCM1420 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. FCC ID:2BAOD-1420 TB-RF-074-1.0 Appendix II ID Label Location Size for the label: 40mm X 10mm Label Location

Internal Photos

FCC ID:2BAOD-1420 TB-RF-074-1.0 Appendix IV EUT Internal Photographs Photo 9 Internal of EUT Photo 10 Internal of EUT FCC ID:2BAOD-1420 TB-RF-074-1.0 Photo 11 Appearance of PCB Photo 12 Appearance of PCB FCC ID:2BAOD-1420 TB-RF-074-1.0 Photo 13 Appearance of PCB Photo 14 Appearance of PCB 4G Antenna FCC ID:2BAOD-1420 TB-RF-074-1.0 Photo 15 Appearance of PCB BLE Antenna

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202305-0005-2 Page: 1 of 4 TB-RF-074-1.0 1 A/F., Building.6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao’an, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Maximum Permissible Exposure Evaluation FCC ID:2BAOD-1420 1. Client Information Applicant : AirSuite Limited Address : 3 Melody Lane, Hamilton East, Hamilton 3216 New Zealand Manufacturer : SHENZHEN FENDA SMART TECHNOLOGY LIMITED Address : Fenda Hi-Tech Park, Zhoushi Road, Shiyan Baoan, Shenzhen, China. 518108 2. General Description of EUT EUT Name : AirSuite Glance LTE Model(s) No. : ASCM1420 Model Difference : ---- Product Description : Operation Frequency: Bluetooth (BLE) V5.2:2402MHz~2480MHz LTE Band 2/4/5/12/13/17/25/26/66 Power Supply : Input: DC 5V DC 3.6V by 10.8Ah Li-ion battery Software Version : 1.0.0 Hardware Version : S010C Remark: The antenna gain provided by the applicant, the adapter and verified for the RF conduction test and adapter provided by TOBY test lab. Note: More test information about the EUT please refer the RF Test Report. Report No.: TBR-C-202305-0005-2 Page: 2 of 4 TB-RF-074-1.0 MPE Calculations for WIFI 1. Antenna Gain: BLE Ceramic Antenna: -0.65dBi. LTE Ceramic Antenna: 2.4dBi 2. EUT Operation Condition: Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 3. Exposure Evaluation: Equation from page 18 of OET Bulletin 65, Edition 97-01 S=(PG)/4πR 2 Where S: power density P: power input to the antenna G: power gain of the antenna in the direction of interest relative to an isotropic radiator. R: distance to the center of radiation of the antenna Report No.: TBR-C-202305-0005-2 Page: 3 of 4 TB-RF-074-1.0 4. Test Result: Mode N TX Conducted Power(max) (dBm) Turn-up Power (dB) Max tune up power (dBm) [P] ANT Gain (dBi) [G] Distance (cm) [R] Power Density (mW/ cm 2 ) [S] limit (mW/cm2) BLE (1Mbps) 1 4.309 4±1 5 -0.65 20 0.0005 1 1 4.4 4±1 5 -0.65 20 0.0005 1 1 4.447 4±1 5 -0.65 20 0.0005 1 BLE (2Mbps)1 1 4.311 4±1 5 -0.65 20 0.0005 1 1 4.392 4±1 5 -0.65 20 0.0005 1 1 4.461 4±1 5 -0.65 20 0.0005 1 LTE Band 2 (M1) 1 23.88 24±1 25 2.4 20 0.1093 1 LTE Band 4 (M1) 1 24.00 24±1 25 2.4 20 0.1093 1 LTE Band 5 (M1) 1 23.85 24±1 25 2.4 20 0.1093 0.55 LTE Band 12 (M1) 1 23.90 24±1 25 2.4 20 0.1093 0.47 LTE Band 13 (M1) 1 23.87 24±1 25 2.4 20 0.1093 0.52 LTE Band 25 (M1) 1 23.80 24±1 25 2.4 20 0.1093 1 LTE Band 26A (M1) 1 23.89 24±1 25 2.4 20 0.1093 0.54 LTE Band 26B (M1) 1 23.92 24±1 25 2.4 20 0.1093 0.54 LTE Band 66 (M1) 1 23.91 24±1 25 2.4 20 0.1093 1 LTE Band 2 (NB) 1 23.77 24±1 25 2.4 20 0.1093 1 LTE Band 4 (NB) 1 23.83 24±1 25 2.4 20 0.1093 1 LTE Band 5 (NB) 1 23.62 24±1 25 2.4 20 0.1093 0.55 LTE Band 12 (NB) 1 23.81 24±1 25 2.4 20 0.1093 0.47 LTE Band 13 (NB) 1 23.69 24±1 25 2.4 20 0.1093 0.52 LTE Band 17 (NB) 1 23.78 24±1 25 2.4 20 0.1093 0.47 LTE Band 25 (NB) 1 23.72 24±1 25 2.4 20 0.1093 1 LTE Band 26A (NB) 1 23.61 24±1 25 2.4 20 0.1093 0.54 LTE Band 26B (NB) 1 23.67 24±1 25 2.4 20 0.1093 0.54 LTE Band 66 (NB) 1 23.74 24±1 25 2.4 20 0.1093 1 Note: RF Output power specifies that Maximum Conducted Peak Output Power. Report No.: TBR-C-202305-0005-2 Page: 4 of 4 TB-RF-074-1.0 5. Conclusion: As specified in Table 1B of 47 CFR 1.1310- Limits for Maximum Permissible Exposure (MPE), Limits for General Population/ Uncontrolled Exposure Frequency Range (MHz) Power density (mW/ cm 2 ) 300-1,500 F/1500 1,500-100,000 1.0 For BLE&LTE MPE limit S: 1mW/ cm 2 MPE limit S: 1mW/ cm 2 6. Summary simultaneous transmission results LTE and Bluetooth support simultaneous transmit the LTE-M1 MPE (Ratio) LTE-NB MPE (Ratio) BLE MPE (Ratio) simultaneous MPE (Ratio) MPE Limits (Ratio) 0.1093 0.1093 0.0005 0.2191 1.0000 So, RF exposure limit warning or SAR test are not required. The EUT will only be used with a separation of 20cm or greater between the antenna and nearby persons and can therefore be considered a mobile transmitter per 47 CFR2.1091 (b). The RF Exposure Information page from the manual is included here for reference. -----END OF REPORT-----

Test Report

Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group Report No.: E4/2018/50029 Page No.: 1 of 8 Antenna Test Report Report No.: E4/2018/50029 Test Plan: Non-compliance with ISO17025 Applicant Name: Raytac Corporation Manufacturer Name: Raytac Corporation Product Name: Bluetooth Low Energy Module Model Number: MDBT50Q (CHIP antenna) Measurements performed at SGS Taiwan Ltd. Hwaya District, Taiwan Issued Date: July 10, 2018 Name Date & Signature Distribution Prepared by: Shawn Yen Asst. Supervisor July 10, 2018 Approved by: Dragon Wu Asst. Manager July 10, 2018 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group Report No.: E4/2018/50029 Page No.: 2 of 8 Measurement System Information General Information Testing Condition:  Temperature: 22±3 ̊C  Humidity: <80% Measurement Facility:  Measurement Chamber: Satimo 3D fully anechoic chamber and its measuring system (Stargate-24-L)  Base Station Simulator: Anritsu MT8820C (or R&S CMU200)  Network Analyzer: Agilent E5071C Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group Report No.: E4/2018/50029 Page No.: 3 of 8 Measurements are performed in a Satimo Stargate-24-L with the StarAct interface for a base station simulator. The Stargate-24-L has 23 probe antennas mounted with equal spacing on a circular arch. Electronic switching of the probe antennas provides outstanding measurement speed. The geometry of the setup, with only a Styrofoam column within 1.6 meters of the EUT, ensures minimum interference and low ripple on the measured radiation patterns. The DUT is placed on top of the pedestal, in the center of the system. Typical Setup for Satimo Stargate-24-L: Inst…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 1 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 RF Test Data for Bluetooth LE (Conducted Measurements) General Description of EUT Product Name: AirSuite Glance LTE Test Model: ASCM1420 Sample ID: C-202305-0005-01-2# Environmental Conditions Temperature: 25°C Relative Humidity: 55% Test Voltage: DC 5V Test Engineer: Huang jian ping Note: For a more detailed features description, please refer to the report TBR-C-202305-0005-8 The report only show the worst case data. Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 2 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 Contents 1. Duty Cycle ........................................................................................................................................................................................... 3 2. Maximum Conducted Output Power ................................................................................................................................................. 7 3. -6dB Bandwidth ................................................................................................................................................................................ 11 4. Occupied Channel Bandwidth ......................................................................................................................................................... 15 5. Maximum Power Spectral Density Level ......................................................................................................................................... 19 6. Band Edge ........................................................................................................................................................................................ 23 7. Conducted RF Spurious Emission .................................................................................................................................................. 28 8. Restrict Band .................................................................................................................................................................................... 35 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 3 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 1. Duty Cycle Condition Mode Frequency (MHz) Antenna Duty Cycle (%) Correction Factor (dB) 1/T (kHz) NVNT BLE 1Mbps 2402 Ant1 100 0 0 NVNT BLE 1Mbps 2440 Ant1 100 0 0 NVNT BLE 1Mbps 2480 Ant1 100 0 0 NVNT BLE 2Mbps 2402 Ant1 100 0 0 NVNT BLE 2Mbps 2440 Ant1 100 0 0 NVNT BLE 2Mbps 2480 Ant1 100 0 0 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 4 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 Test Graphs Duty Cycle NVNT BLE 1Mbps 2402MHz Ant1 Duty Cycle NVNT BLE 1Mbps 2440MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 5 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 Duty Cycle NVNT BLE 1Mbps 2480MHz Ant1 Duty Cycle NVNT BLE 2Mbps 2402MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 6 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 Duty Cycle NVNT BLE 2Mbps 2440MHz Ant1 Duty Cycle NVNT BLE 2Mbps 2480MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 7 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 2. Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT BLE 1Mbps 2402 Ant1 4.309 30 Pass NVNT BLE 1Mbps 2440 Ant1 4.4 30 Pass NVNT BLE 1Mbps 2480 Ant1 4.447 30 Pass NVNT BLE 2Mbps 2402 Ant1 4.311 30 Pass NVNT BLE 2Mbps 2440 Ant1 4.392 30 Pass NVNT BLE 2Mbps 2480 Ant1 4.461 30 Pass Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 8 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 Test Graphs Power NVNT BLE 1Mbps 2402MHz Ant1 Power NVNT BLE 1Mbps 2440MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 9 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 Power NVNT BLE 1Mbps 2480MHz Ant1 Power NVNT BLE 2Mbps 2402MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 10 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 Power NVNT BLE 2Mbps 2440MHz Ant1 Power NVNT BLE 2Mbps 2480MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0005-8 Page: 11 of 39 FCC ID:2BAOD-1420 TB-RF-074-1.0 3. -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 1Mbps 2402 Ant1 0.69 0.5 Pass NVNT BLE 1Mbps 2440 Ant1 0.7…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202305-0005-8 Page: 1 of 52 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Radio Test Report FCC ID: 2BAOD-1420 Report No. : TBR-C-202305-0005-8 Applicant : AirSuite Limited Equipment Under Test (EUT) EUT Name : AirSuite Glance LTE Model No. : ASCM1420 Series Model No. : ---- Brand Name : AirSuite Glance Sample ID : C-202305-0005-01-1# & C-202305-0005-01-2# Receipt Date : 2023-03-09 Test Date : 2023-03-09 to 2023-05-19 Issue Date : 2023-05-19 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10: 2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Witness Engineer : Camille Li Engineer Supervisor : Ivan Su Engineer Manager : Ray Lai This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Sam Mathews
[email protected]+64 27 225 8082Fax: N/A

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]---

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.80 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.