  1. Home/
  2. Yongkang Saihan Technology Co.,Ltd/
  3. 2BATD-CS-WP6

2BATD-CS-WP6Fitness walker

Yongkang Saihan Technology Co.,Ltd
Fitness walker - FCC ID 2BATD-CS-WP6 - Yongkang Saihan Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
May 09, 2023
Application Purpose
Original Equipment
Date of Application
May 09, 2023
Equipment Note
Fitness walker
Frequency Range
2402.00000000 - 2480.00000000
Company
Yongkang Saihan Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ProductInstruction Fitnesswalker Model:CS-WP6 Pleasereadtheinstructioncarefullybeforeusing Content 1.Securitycautions.................................................................1 2.QualityAssuranceCommitment.........................................2 3.Configurationlistandtechnicalparameters.........................2 4.Productparts........................................................................3 5.Assemblyinstructions...........................................................3 6.Functionaloperationinstructions..........................................5 7.Warm-upexercise.................................................................6 8.MaintenanceGuidelines......................................................8 9.Faultcode............................................................................8 -1- Thankyouforpurchasingourproduct,ourproductswillhelptoimproveyourhealth. 1.Securitycautions Inordertoensureyoursafetyandavoidaccidents,pleasereadtheinstructionscarefullybefore use. Thisproductisindooruseonly,pleasedonotmakeitoruseitoutdoors;thetreadmillshouldbe placedinaflatandcleanposition,donotputitinathickcarpetornearwaterarea,thereshould be3-6ftbarrier-freesafetyareabehindthetreadmill.  Thisproductisforadults,minorsneedadultcare.Itisforbiddenforthosewhofeelunwellor mentallyhandicappedorlackcommonsensetouseit.Unlesstheyareunderthesupervision orguidanceofthepersonresponsiblefortheirsafetyregardingtheuseoftheproduct. Ifthepowercordisdamaged,inordertoavoiddanger,itmustbereplacedbythemanufacturer orprofessionalmaintenancepersonnel. Thisproductisonlyusedfor100V-120VACvoltage.Pleaseusethepowersocketwithsafe groundline.Theinstallationandgroundingofthegroundingplugmustbeconsistentwiththe parametersoftheuser'sarea.Iftheplugandsocketareincompatible,pleasearrangequalified electriciansorafter-salespersonneltohandleit. Checkallpartsbeforeusetoensurethatthescrewandnutarelocked  Whenusingit,pleasewearcomfortableandtightclothestoavoidtheclothesbeinghungbythe machine.Don'tletchildrenorpetscomeneartoavoidaccidents.  Avoidallmovingpartswithbothhands.Donotplacehandsorfeetinthespaceunderthe runningbelt.  Thisproductisdesignedforfamilyuseonly,butnotsuitableforprofessionaltrainingandtesting, andcannotbeusedformedicalpurposes.  Theheartratedisplayofthisproductdoesnotprovidedataformedicalpurpose. Thisproductisonlyforonepersonontherunningbelt.  Beforecleaningandmaintenance,pleaseshutdownandunplugthepowerplug. Shutdownthemachineandunplugthepowerplugwhenyouleave.  Pleaseusethesparepartsprovidedbytheoriginalfactory.Itisstrictlyforbiddentoreplace themprivately.  ThisproductisofHCgrade,andmaximumuser’sweightis200lbs. 2.QualityAssuranceCommitment Weensurethattheproductismadeofhighqualitymaterials.  Innormaluse,ifthereisaproblem,wewillberesponsibleforthewarranty. Thewarrantyperiodisoneyear(fromthedateofpurchase).Ifyoubuyproductswithquality problems,pleasecontactourcustomerservicewithin12months.Pleasedonotdealwiththem withoutpermission.  Thefollowingsarenotcoveredbythewarranty: Damagecausedbyexternalfactors. -2- Usenon-originalaccessories.  Privatelyhandledincorrectly.  Notfollowtheinstructions.  Thispledgeisvalidonlyforprivateusebyfamiliesandisnotapplicabletoprofessionaltrainingsuch asgyms. Ifyouneedtobuynon-warrantyaccessories,pleasecontactcustomerservice.Pleaseprovidethe followinginformationwhenordering: Instructions.  Productmodel. Fittingsserialnumber.  Certificateofpurchasedate. Beforetheconfirmationofourcustomerservice,pleasedonotsendtheproductstoourcompany,and sendthembackwithoutpermission.Ourcompanydoesnotbearanycost. 3.Configurationlistandtechnicalparameters 1.Walkingpadconfiguration PartsName Sketch(forreference)QTY Walkingpadmachine 1 Remotecontroller 1 Instructions 1 Hardwarepackage 1 Siliconeoil 1 2.Technicalparameters ParanameParametersParanameParameters Packingdimension50.79*22.64*5.5inchProductsize48.43*19.3*4.75inch Runningarea15*40.55inchmaximumpower380W Speedrange0.6-3.8mphMaxcapacity200lbs Netweight37.4lbsGrossweight43.4lbs -3- 4. Productparts 5.Assemblyinstructions Assemblysteps Outofthebox,takeouttheaccessoriesandthemachinefromthebox,andputthemachineona flatground,connectittothepoweranduseit. 6.Functionaloperationinstructions FunctionDescription 1:Start/stopbuttonontheremotecontrol,speedup/down. 2:Thespeedoftheremotecontrolis0.2mphspeedacceleration/decelerationeverytimeyoupress theplus/minusbutton. 3:Bluetoothmusic,BluetoothnameMAXFREE00001-65000. 4:Speeddisplay0.6-3.8mile,caloriesdisplay000-999KCAL,timedisplay00-99minutes,Themileage shows0.00-99.9mile. 5:After5minutesofstandby,itwillenterthedormantstate,andthedisplaywillturnoff. Runningbelt Displaypanel Motorcover Motorlowercover Footpedal Backcornerright Bluetoothspeaker Backcornerleft Powerswitch -4- DisplayPanel Infraredreceiver:Pleasepointtheremotetothisareawhenusingtheremotecontroller. Displayscreen:SPEEDwilldisplaywhenadjustingspeed;SPEED/CAL/TIME/DIST.Willbedisplayed inloopby3secondsinterval. Buttonfunction: Button:Bypressingthisbutton,thetreadmillstartsrunningwithlowestspeedunderstandby status.Andthetreadmillstopsrunningunderrunningstatus. +Button:Shortpress-Increasethespeedby0.2mph Longpress-Continuallyincreasethespeedby0.2mph -Button:Shortpress-Decreasethespeedby0.2mph Longpress-Continuallydecreasethespeedby0.2mph Note:thebuttonsasidethedisplayscreenisforbackupusingonly(whenremotecontrollernot working).Forsafetyreason,theuserofthetreadmillshouldfirststandontherunningbelt,and anotheradultshouldhelptoturnthemachineonandadjustittoaproperspeed.Whenfinishing running,anotheradultneedtohelptopresstheStopbuttontostopthetreadmill,andthenwalkoff thetreadmillafteritstops.Theaccidentalinjurycausedbyoperationnotinaccordancewiththe correctuserequirementshasnothingtodowiththetreadmillfactory. Remotecontroller ◆Needtopullouttheremotecontrolinsulationpaperbeforeuse Start/Stop Infraredreceiver Availablestatus Pulloutthe Preparetodraw Speeddown Speedup Start/Sotpkey Speeddown Speedup Functiondisplay:speed, calories,…

Text truncated - open the document above for the full version.

Attestation Statements

Yongkang Saihan Technology Co.,Ltd NO.666 Sifang Road,Chengxi New District Yongkang, Zhejiang China The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-5-10 To whom it may concern: We, Yongkang Saihan Technology Co.,Ltd , hereby certify that the equipment for which authorization is sought (FCC ID: 2BATD-CS-WP6) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). Sincerely, Signature Guangyi Luo Engineer Yongkang Saihan Technology Co.,Ltd 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V02

Attestation Statements

Yongkang Saihan Technology Co.,Ltd The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 5/9/2023 U.S. Agent Designation Yongkang Saihan Technology Co.,Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BATD-CS-WP6): Contact Name: Tim Payne C ompany of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of Yongkang Saihan Technology Co.,Ltd. Yongkang Saihan Technology Co.,Ltd with the FRN 0033640913 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature Guangyi Luo Engineer Yongkang Saihan Technology Co.,Ltd Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V04

Cover Letter(s)

Yongkang Saihan Technology Co.,Ltd Add: NO.666 Sifang Road,Chengxi New District Yongkang, Zhejiang China Date: 2023-5-10 FCC ID: 2BATD-CS-WP6 Dear Sir/Madam, We, Yongkang Saihan Technology Co.,Ltd Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Fitness walker Model no.: CS-WP6, TT-200A, TT-200E, TT-200F, TT-200G, TT-200H, TT-200I, TT-200J, P2, P3, CS- WP2, GT2, GT6, GT8, LS1, LS3, LS5, P1 Sincerely, Name/Title: Guangyi Luo/Engineer Company: Yongkang Saihan Technology Co.,Ltd Address: NO.666 Sifang Road,Chengxi New District Yongkang, Zhejiang China Phone: 0579-89281997 Fax: 0579-89281997 E-Mail: [email protected]

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2023-5-10> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BATD-CS-WP6 CS-WP6 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Guangyi Luo/Engineer Company: Yongkang Saihan Technology Co.,Ltd Address: NO.666 Sifang Road,Chengxi New District Yongkang, Zhejiang China Phone: 0579-89281997 Fax: 0579-89281997 E-Mail: [email protected]

Cover Letter(s)

Yongkang Saihan Technology Co.,Ltd NO.666 Sifang Road,Chengxi New District Yongkang, Zhejiang China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-5-10 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BATD-CS-WP6 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Guangyi Luo/Engineer Company: Yongkang Saihan Technology Co.,Ltd Address: NO.666 Sifang Road,Chengxi New District Yongkang, Zhejiang China Phone: 0579-89281997 Fax: 0579-89281997 E-Mail: [email protected]

External Photos

Page1of4FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8

ID Label/Location Info

Page1of1FCCID:2BTAD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L8.0cmx5.0cm) LabelLocation Fitnesswalker Model:CS-WP6 FCCID:2BATD-CS-WP6 Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowing twoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevice mustacceptanyinterferencereceived,includinginterferencethatmaycauseundesired operation.

Internal Photos

Page1of3FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Antenna Page3of3FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6

RF Exposure Info

Page1of4FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation FCCID2BATD-CS-WP6 ProductnameFitnesswalker ModelnumberCS-WP6 AdditionalModelTT-200A,TT-200E,TT-200F,TT-200G,TT-200H,TT-200I, TT-200J,P2,P3,CS-WP2,GT2,GT6,GT8,LS1,LS3,LS5,P1 ModelDeclarationPCBboard,structureandinternalofthesemodel(s)arethesame, Sonoadditionalmodelsweretested PowersupplyInput:100~120VAC,50/60Hz,550W ModulationType GFSK,π/4-DQPSKforBluetoothV5.0(DSS) GFSKforBluetoothV5.0(DTS) AntennaTypePCBAntenna AntennaGain4.02dBi(Max.) HardwareversionV1.0 SoftwareversionV1.0 FCCOperationfrequency2402MHz-2480MHz ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevices 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesum oftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoesnot applywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalentconditions. Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimumtest separationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. Page2of4FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequency ElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation PCBAntennacanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal Identification Antennatypeand antennanumber Operatefrequency band Maximumantenna gain Note AntennaPCBAntenna2400MHz-2500MHz4.02dBiBTAntenna Page3of4FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 6.ConductedPower <BTMaxConductedPower> ModeChannelFrequency(MHz) MaxConductedPower (dBm) GFSK 02402 -0.32 392441 0.35 782480 2.84 π/4-DQPSK 02402 -1.72 392441 0.03 782480 2.15 <BTLEMaxConductedPower> ModeChannelFrequency(MHz) MaxConductedPower (dBm) GFSK 02402 -4.1 192440 -3.04 392480 -4.03 7.ManufacturingTolerance <BT> GFSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)002.0 Tolerance±(dB)1.01.01.0 π/4-DQPSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)-1.002.0 Tolerance±(dB)1.01.01.0 <BTLE> GFSK(Peak) ChannelChannel0Channel19Channel39 Target(dBm)-4.0-3.0-4.0 Tolerance±(dB)1.01.01.0 Page4of4FCCID:2BATD-CS-WP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 8.MeasurementResults AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromany bodypartoftheuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparation distance,r=20cm,aswellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensity canbeobtained. [Antenna] <BT> Band/Mode RFoutputpower AntennaGain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW GFSK3.01.99534.020.00101.0000 π/4-DQPSK3.01.99534.020.00101.0000 <BTLE> Band/Mode RFoutputpower AntennaGain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dB…

Text truncated - open the document above for the full version.

Test Report

Antenna_Specification Manufacturer: Yongkang Saihan Technology Co.,Ltd Model: CS-WP6 SPECIFICATIONS Frequency(MHz)2400-2480 Peak Gain(dBi)4.015 Average Gain(dBi)>-4 VSWR<1.6 Impedance(Ω)50Ω Antenna TypePlannar Inverted F Antenna on board PolarizationLinear Test environment Z X Y Antenna dimensions Passive S parameter of antenna: 驻波比(VSWR)、回波损耗(Return Loss)And Smith circle chart Antenna efficiency and gain Frequency(MHz)Gain(dBi)Effciency(%)AverageGain(dBi)Efficiency(dB) 24000.66454.12%-3.155-2.666 24100.56849.63%-3.781-3.043 24200.26246.10%-3.949-3.363 24300.69648.69%-3.679-3.126 24401.14448.47%-3.738-3.145 24501.5951.42%-3.288-2.889 24602.29755.46%-2.914-2.561 24703.2562.98%-2.21-2.008 24804.01571.61%-1.617-1.45 Average1.61054.28%-3.148-2.695 Peak4.01571.61%-1.617-1.45 2480MHz 2D-Theta Pattern 2480MHz 2D-Phi Pattern 2480MHz 3D-Horizontal Pattern 2480MHz 3D-Vertical Pattern 2480MHz 3D-Total Pattern

Test Report

Page1of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBT(ConductedMeasurement) ProductName:Fitnesswalker TestModel:CS-WP6 EnvironmentalConditions Temperature: 23.5  C RelativeHumidity:52.2% ATMPressure:100.0kPa TestEngineer: NickPeng Supervisedby:LingZhu Page2of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.1-20dBBandwidth ConditionModeFrequency(MHz)Antenna-20dBBandwidth(MHz)Limit-20dBBandwidth(MHz)Verdict NVNT1-DH52402Ant11.169N/APass NVNT1-DH52441Ant10.914N/APass NVNT1-DH52480Ant10.91N/APass NVNT2-DH52402Ant11.274N/APass NVNT2-DH52441Ant11.274N/APass NVNT2-DH52480Ant11.277N/APass Page3of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs -20dBBandwidthNVNT1-DH52402MHzAnt1 -20dBBandwidthNVNT1-DH52441MHzAnt1 Page4of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -20dBBandwidthNVNT1-DH52480MHzAnt1 -20dBBandwidthNVNT2-DH52402MHzAnt1 Page5of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -20dBBandwidthNVNT2-DH52441MHzAnt1 -20dBBandwidthNVNT2-DH52480MHzAnt1 Page6of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNT1-DH52402Ant11.032 NVNT1-DH52441Ant10.774 NVNT1-DH52480Ant10.773 NVNT2-DH52402Ant11.179 NVNT2-DH52441Ant11.18 NVNT2-DH52480Ant11.174 Page7of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs OBWNVNT1-DH52402MHzAnt1 OBWNVNT1-DH52441MHzAnt1 Page8of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity OBWNVNT1-DH52480MHzAnt1 OBWNVNT2-DH52402MHzAnt1 Page9of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity OBWNVNT2-DH52441MHzAnt1 OBWNVNT2-DH52480MHzAnt1 Page10of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.3MaximumConductedOutputPowerande.i.r.p. ConditionModeFrequency(MHz)AntennaTotalPower(dBm)Limit(dBm)Verdict NVNT1-DH52402Ant1-0.3221Pass NVNT1-DH52441Ant10.3521Pass NVNT1-DH52480Ant12.8421Pass NVNT2-DH52402Ant1-1.7221Pass NVNT2-DH52441Ant10.0321Pass NVNT2-DH52480Ant12.1521Pass EIRP ConditionModeFrequency (MHz) AntennaTotalPower (dBm) Antenna Gain Report EIRPPower(dBm) Limit (dBm) Verdict NVNT1-DH52402Ant1-0.324.023.736Pass NVNT1-DH52441Ant10.354.024.3736Pass NVNT1-DH52480Ant12.844.026.8636Pass NVNT2-DH52402Ant1-1.724.022.336Pass NVNT2-DH52441Ant10.034.024.0536Pass NVNT2-DH52480Ant12.154.026.1736Pass Page11of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PowerNVNT1-DH52402MHzAnt1 PowerNVNT1-DH52441MHzAnt1 Page12of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNT1-DH52480MHzAnt1 PowerNVNT2-DH52402MHzAnt1 Page13of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNT2-DH52441MHzAnt1 PowerNVNT2-DH52480MHzAnt1 Page14of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.…

Text truncated - open the document above for the full version.

Test Report

Page30of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity BandEdge(Hopping)NVNT2-DH52480MHzAnt1HoppingRef BandEdge(Hopping)NVNT2-DH52480MHzAnt1HoppingEmission Page31of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.8ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNT1-DH52402Ant1-37.96-20Pass NVNT1-DH52441Ant1-53.93-20Pass NVNT1-DH52480Ant1-54.3-20Pass NVNT2-DH52402Ant1-37.6-20Pass NVNT2-DH52441Ant1-39.98-20Pass NVNT2-DH52480Ant1-55.05-20Pass Page32of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs Tx.SpuriousNVNT1-DH52402MHzAnt1Ref Tx.SpuriousNVNT1-DH52402MHzAnt1Emission Page33of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Tx.SpuriousNVNT1-DH52441MHzAnt1Ref Tx.SpuriousNVNT1-DH52441MHzAnt1Emission Page34of42FCCID:2BATD-CS-WP6IC:30379-CSWP6 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mai…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Guangyi Luo
[email protected]0579-89281997Fax: 0579-89281997

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.90 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Yongkang Saihan Technology Co.,Ltd

2BATD-SH02-B

Remote control

Sep 29, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter