Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
COM2USKOREA 131,Gasandigital1-ro,Geumcheon-gu,Seoul,RepublicofKorea TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotifytheFCCwithin30daysvia thegrantingTCB. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 4/23/23 U.S.AgentDesignation COM2USKOREAacknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatesto actastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID: 2BAUR-SWWCA001): NameandcompanyofU.S.agent:FCCUSAgentInc. PhysicalU.S.addressofagent:1942BroadwaySte314CBoulderCO80302US ContactPerson:DavidWilson FRNofU.S.agent:0033649971 EmailaddressofU.S.agent:[email protected] FCCUSAgentInc.acknowledgestheirobligationtoacceptserviceofprocessonbehalfofCOM2US KOREA. COM2USKOREAwiththeFRN0033654021acceptsitsobligationtomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusion ofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheveris later. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirements listedunder§2.911(d)(7). Sincerely, Signature DonggyuKim CHO COM2USKOREA Signature DavidWilson CEO FCCUSAgentInc. 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 4
Sincerely, Name/Title: Donggyu Kim/Cho Company: COM2US KOREA Address: 131, Gasan digital 1-ro, Geumcheon-gu, Seoul South Korea Phone: 82 10-5122-6307 Fax: N/A E-Mail: [email protected]
Shenzhen Tongzhou Testing Co.,Ltd FCC ID: 2BAUR-SWWCA001 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd Page 1 of 4 EXTERIOR PHOTOGRAPHS OF EUT Fig.1 Fig.2 Shenzhen Tongzhou Testing Co.,Ltd FCC ID: 2BAUR-SWWCA001 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd Page 2 of 4 Fig.3 Fig.4 Shenzhen Tongzhou Testing Co.,Ltd FCC ID: 2BAUR-SWWCA001 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd Page 3 of 4 Fig.5 Fig.6 Shenzhen Tongzhou Testing Co.,Ltd FCC ID: 2BAUR-SWWCA001 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd Page 4 of 4 Fig.7
Label Location: FCC ID: 2BAUR-SWWCA001
Shenzhen Tongzhou Testing Co.,Ltd FCC ID: 2BAUR-SWWCA001 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd Page 1 of 2 INTERIOR PHOTOGRAPHS OF EUT Fig.1 Fig.2 Antenna Shenzhen Tongzhou Testing Co.,Ltd FCC ID: 2BAUR-SWWCA001 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd Page 2 of 2 Fig.3 Fig.4
Page 1 of 9 Report No.: TZ230404215-E2 FCC TEST REPORT Test report On Behalf of COM2US KOREA For Summoners War Angelmon Wireless Charger Model No.: SWWCA001 FCC ID: 2BAUR-SWWCA001 Prepared for : COM2US KOREA 131, Gasan digital 1-ro, Geumcheon-gu, Seoul, Republic of Korea Prepared By : Shenzhen Tongzhou Testing Co.,Ltd 1th Floor, Building 1, Haomai High-tech Park, Huating Road 387, Dalang Street, Longhua, Shenzhen, China Date of Test: 2023/4/7 ~ 2023/4/13 Date of Report: 2023/4/13 Report Number: TZ230404215-E2 The test report apply only to the specific sample(s) tested under stated test conditions It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Page 2 of 9 Report No.: TZ230404215-E2 TEST RESULT CERTIFICATION Applicant’s name ................. : COM2US KOREA Address ................................. : 131, Gasan digital 1-ro, Geumcheon-gu, Seoul, Republic of Korea Manufacture's Name ............ : Shenzhen hoosung technology co.,LTD Address ................................. : No. 113, 1st Road Gushu, Xixiang Street, Baoan District, Shenzhen, China Product description Trade Mark ............................ : Com2uS Product name ........................... : Summoners War Angelmon Wireless Charger Model ..................................... : SWWCA001 Standards ............................. : FCC Rules and Regulations Part 2.1091, ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Tongzhou Testing Co.,Ltd is acknowledged as copyright owner and source of the material. Shenzhen Tongzhou Testing Co.,Ltd takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of performance of tests ............. : 2023/4/7 ~ 2023/4/13 Date of Issue ........................................... : 2023/4/13 Test Result ............................................... : Pass Testing Engineer : (Nancy Li) Technical Manager : (Hugo Chen) Authorized Signatory : (Andy Zhang) Page 3 of 9 Report No.: TZ230404215-E2 1. GENERAL INFORMATION 1.1 General Description of EUT Equipment Summoners War Angelmon Wireless Charger Model Name SWWCA001 Model Difference N/A Test Model SWWCA001 Trade Mark Com2uS FCC ID 2BAUR-SWWCA001 Antenna Type Coil Antenna Antenna Gain 0dBi Operation frequency 110– 205 KHz Test Frequency 116.75 KHz Modulation Type ASK Power Rating Input: 5V2A, 9V2A, 12V1.5A Output: 5V1A, 7.5V1A, 9V1.12A, 9V1.67A (Wireless charger) Test Sample ID TZ230404215-1# Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. Page 4 of 9 Report No.: TZ230404215-E2 2. SUMMARY OF TEST RESULTS 2.1 Test procedures according to the technical standards: FCC KDBD01 RF Exposure Wireless Charging App v03r01 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB680106 D01v03r01 (3)(3) Electric Field Strength (E) (V/m) PASS Magnetic Field Strength (H) (A/m) PASS 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 All emissions, radiated(<30M)(9KHz-30MHz) ±2.45dB 2 Temperature ±0.5°C 3 Humidity ±2% Page 5 of 9 Report No.: TZ230404215-E2 2.3 Test Instruments Equipment Manufacturer Model Serial no. Calibrated date Calibrated Due Exposure Level Tester Narda ELT-400 N-0713 2022-08-03 2023-08-02 B-Field Probe Narda ELT-400 M-1154 2022-08-03 2023-08-02 NOTE: 1. The calibration interval of the above test instruments is 12 months. 2.4 Special Accessories No. Equipment Manufacturer Model 1 Wireless charger tester YBZ YBZ 2 AC adapter Xiaomi MDY-10-EH 2.5 Operation of EUT during testing Test Modes: Mode 1 AC/DC Adapter (12V/1.5A) + EUT + Wireless charger tester (Load 15W) Record Mode 2 AC/DC Adapter (12V/1.5A) + EUT + Wireless charger tester (Load 10W) Pre-test Mode 3 AC/DC Adapter (12V/1.5A) + EUT + Wireless charger tester (Load 7.5W) Pre-test Mode 4 AC/DC Adapter (12V/1.5A) + EUT + Wireless charger tester (Load 5W) Pre-test Mode 5 AC/DC Adapter (9V/2A) + EUT + Wireless charger tester (Load 15W) Pre-test Mode 6 AC/DC Adapter (9V/2A) + EUT + Wireless charger tester (Load 10W) Pre-test Mode 7 AC/DC Adapter (9V/2A) + EUT + Wireless charger tester (Load 7.5W) Pre-test Mode 8 AC/DC Adapter (9V/2A) + EUT + Wireless charger tester (Load 5W) Pre-test Mode 9 AC/DC Adapter (5V/2A) + EUT + Wireless charger tester (Load 15W) Pre-test Mode 10 AC/DC Adapter (5V/2A) + EUT + Wireless charger tester (Load 10W) Pre-test Mode 11 AC/DC Adapter (5V/2A) + EUT + Wireless charger tester (Load 7.5W) Pre-test Mode 12 AC/DC Adapter (5V/2A) + EUT + Wireless charger tester (Load 5W) Pre-test Note: All test modes were pre-tested, but we only recorded the worst case in this report. Page 6 of 9 Report No.: TZ230404215-E2 3. MAXIMUM PERMISSIBLE EXPOSURE Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: …
Text truncated - open the document above for the full version.
深圳市宸兴电子技术有限公司 Shenzhen Chenxing Electronic Technology Co,Ltd. 第 1 页 产 品 规 格 书 PRODUCT SPECIFICATION FOR APPROVAL 客 户 名 称: CUSTOMER 新全汉 产 品 名 称: PRODUCT NAME Power Transmitter A11 物 料 编 码: PART No. 产 品 规 格: PRODUCT SPEC Inductance:6.3uH±10% Shielding spec:50*5.3*1 with two grooves Silk covered wire spec: 2 UEW/155 0.08*105*10Ts Segment Length:50mm Double side Type 日 期: DATE 2023/04/10 版 本 型 号: VERSION REV 1.0 版本 Revision 变更内容 Modified Content 责任人 Principle 日期 Date 备注 Note REV 1.0 首次发布 薛 磊 2023-04-10 制定/PREPARED BY 审核/CHECKED BY 核准/APPROVED BY 李小云 周小菊 客户认可签名及盖章 Authorized signature & company chop 深圳市宸兴电子技术有限公司 Shenzhen Chenxing Electronic Technology Co,Ltd. 第 2 页 产 品 规 格 SPECIFICATION 一、Mechanical Specification: 二、Schematic: Shielding Outer Diameter(A) 49.5±0.5mm Shielding Inner Diameter(G) 5±0.3mm Coil Outer Diameter (B) 42±1mm Coil Inner Diameter (C) 20.5±0.5mm Total Thickness(D) <2.5mm Segment Length(E) 50mm±3mm Pin Length(F) 3±2mm Shielding Thickness 1±0.1mm Shielding Shape Circle with two grooves Adhesive Tape Double side Type 深圳市宸兴电子技术有限公司 Shenzhen Chenxing Electronic Technology Co,Ltd. 第 3 页 三、Coil Parameter: 端子 TERMINAL 线径 WIRE 圈数 Turns 绕线方向 Winding Direction S F 2UEW/155 0.08*105 10Ts CCW ELECTRICAL SPECIFICATIONS 四、Electrical Specification: 温度 TEMPERATURE:25±10°C, 湿度RELATIVE HUMIDITY:65±20% 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TEST FREQUENCY 测试仪器 TEST EQUIPMENTS IND. S-F 6.3uH±10% 100KHz/1.0V LCZ METER 1062B 五、Product Picture:
Report No.: TZ230404215-E1 Page 1 of 20 FCC TEST REPORT Test report On Behalf of COM2US KOREA For Summoners War Angelmon Wireless Charger Model No.: SWWCA001 FCC ID: 2BAUR-SWWCA001 Prepared for : COM2US KOREA 131, Gasan digital 1-ro, Geumcheon-gu, Seoul, Republic of Korea Prepared By : Shenzhen Tongzhou Testing Co.,Ltd 1th Floor, Building 1, Haomai High-tech Park, Huating Road 387, Dalang Street, Longhua, Shenzhen, China Date of Test: 2023/4/7 ~ 2023/4/13 Date of Report: 2023/4/13 Report Number: TZ230404215-E1 The test report apply only to the specific sample(s) tested under stated test conditions It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: TZ230404215-E1 Page 2 of 20 TEST RESULT CERTIFICATION Applicant’s name ................. : COM2US KOREA Address ................................. : 131, Gasan digital 1-ro, Geumcheon-gu, Seoul, Republic of Korea Manufacture's Name ............ : Shenzhen hoosung technology co.,LTD Address ................................. : No. 113, 1st Road Gushu, Xixiang Street, Baoan District, Shenzhen, China Product description Trade Mark ............................ : Com2uS Product name ........................... : Summoners War Angelmon Wireless Charger Model ..................................... : SWWCA001 Standards ............................. : FCC Rules and Regulations Part 15 Subpart C (Section 15.209), ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Tongzhou Testing Co.,Ltd is acknowledged as copyright owner and source of the material. Shenzhen Tongzhou Testing Co.,Ltd takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of performance of tests ............. : 2023/4/7 ~ 2023/4/13 Date of Issue ........................................... : 2023/4/13 Test Result ............................................... : Pass Testing Engineer : (Nancy Li) Technical Manager : (Hugo Chen) Authorized Signatory : (Andy Zhang) Report No.: TZ230404215-E1 Page 3 of 20 Table of Contents Page 1 TEST SUMMARY ................................................................................................ 4 1.1 TEST PROCEDURES AND RESULTS ....................................... 4 1.2 TEST FACILITY ........................................................................... 4 1.3 MEASUREMENT UNCERTAINTY ............................................... 4 2 GENERAL INFORMATION ................................................................................. 5 2.1 General Description of EUT ......................................................... 5 2.2 Operation of EUT during testing .................................................. 6 2.3 Description of Test Setup ............................................................. 6 2.4 Description of Test Facility ........................................................... 7 3 Measurement Instruments List ............................................................................ 8 4 CONDUCTED EMISSION TEST ......................................................................... 9 4.1 Block Diagram of Test Setup ....................................................... 9 4.2 Conducted Power Line Emission Limit ......................................... 9 4.3 Test Procedure ............................................................................ 9 4.4 Test Result ................................................................................... 9 5 Bandwidth ......................................................................................................... 12 5.1 Block Diagram of Test Setup ..................................................... 12 5.2 Rules and specifications ............................................................ 12 5.3 Test Procedure .......................................................................... 12 5.4 Test Result ................................................................................. 13 6 RADIATED EMISSIONS ................................................................................... 14 6.1 Block Diagram of Test Setup ..................................................... 14 6.2 Rules and specifications ............................................................ 15 6.3 Test Procedure .......................................................................... 16 6.4 Test Result ................................................................................. 16 7 ANTENNA REQUIREMENT .............................................................................. 19 7. TEST SETUP Photographs of EUT .................................................................. 20 8. Exterior Photographs of the EUT ..................................................................... 20 9. INTERIOR Photographs of the EUT ................................................................. 20 Report No.: TZ230404215-E1 Page 4 of 20 1 TEST SUMMARY 1.1 TEST PROCEDURES AND RESULTS DESCRIPTION OF TEST RESULT CONDUCTED EMISSIONS TEST COMPLIANT RADIATED EMISSION TEST COMPLIANT OCCUPIED BANDWIDTH MEASUREMENT COMPLIANT ANTENNA REQUIREMENT COMPLIANT 1.2 TEST FACILITY Test Firm : Shenzhen Tongzhou Testing Co.,Ltd Address 1th Floor, Building 1, Haomai High-tech Park, Huating Road 387, Dalang Street, Longhua, Shenzhen, China 1.3 MEASUREMENT UNCERTAINTY Measurement Uncertainty Conducted Emission Expanded Uncertainty = 2.23dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.08dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz) = 4.42dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.06dB, k=2 Report No.: TZ230404215-E1 Page 5 of 20 2 GENERAL INFORMATION 2.1 General Description of EUT Equipment Summoners War Angelmon Wireless Charger Mode…
Text truncated - open the document above for the full version.
Shenzhen Tongzhou Testing Co.,Ltd FCC ID: 2BAUR-SWWCA001 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd Page 1 of 2 TEST SETUP PHOTOS OF THE EUT Radiated Emission Shenzhen Tongzhou Testing Co.,Ltd FCC ID: 2BAUR-SWWCA001 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd Page 2 of 2 Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |

Summoners War Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz