FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. EchoCare Technologies Ltd./
  3. 2BAUTECT1310PC

2BAUTECT1310PCRemote Home Care monitoring system

EchoCare Technologies Ltd.
Remote Home Care monitoring system - FCC ID 2BAUTECT1310PC - EchoCare Technologies Ltd.
Click to zoom

Application Details

Equipment Class
UWB - Ultra Wideband Transmitter
Date of Grant
Sep 26, 2023
Application Purpose
Original Equipment
Date of Application
Sep 21, 2023
Equipment Note
Remote Home Care monitoring system
Frequency Range
8000.00000000 - 9500.00000000
Company
EchoCare Technologies Ltd.
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ECHO System User Guide Release 2.0, April 2023 EchoCare Technologies Ltd. Confidential and Proprietary Information Contents EchoCare Technologies Ltd. Confidential and Proprietary Information Echo System UG and Product Specifications 2 Release 2.0, April 2023 Contents 1 System Overview ................................................................................................................... 3 1.1 Introduction 3 1.2 Main Features and Functions 4 1.2.1 The ECHO System Capabilities 4 1.2.2 System Use Cases 5 1.2.3 Display Example - Caregiver Dashboard 5 1.3 System Architecture 6 2 Offered Services ..................................................................................................................... 7 2.1 Monitoring Services 8 3 User Guide 10 3.1 Installation Guide 10 3.1.1 Safety and Precaution Guidelines 10 3.1.2 Product Package Contents 11 3.2 System Setup 12 3.2.1 Connecting PC to the ECHO Device 12 3.2.2 Initial Configuration 12 3.3 EchoCloud Dashboard 19 3.3.1 Introduction 19 3.3.2 Caregivers Dashboard 21 3.3.3 Displayed Indications and Alerts 22 3.3.4 Respiration Monitoring (Optional Service) 27 3.3.5 Daily Living Activity Report (Optional Service) 29 3.4 Mobile Application 33 4 Appendix – Acronyms and Abbreviations .............................................................................. 34 5 Statements 35 5.1 FCC Statements 35 5.2 IC Statements 35 System Overview Introduction EchoCare Technologies Ltd. Confidential and Proprietary Information Echo System UG and Product Specifications 3 Release 2.0, April 2023 1 System Overview 1.1 Introduction The ECHO system by EchoCare Technologies is capable of monitoring persons living in their homes or in nursing care facilities. Decisions on emergency alerts, various indications and reports, are made in real time, and are sent to pre-defined clients – site admins, caregivers, etc. Therefore, the ECHO system helps increasing the safety of the persons being monitored, and helps tracking their physical condition for identifying possible degradations that may happen over time. The purpose of this document is to provide information about: • System architecture • Main features and functions of the ECHO system • Review of product variants • Guidance for system assembly and installation • Guidance for system setup (initialization, calibration and mapping) • System usage with its cloud capabilities • Types of, alerts, indications and reports • Product specifications • Applicable standards and certificates Figure 1 : Assembled ECHO System Mounted on Ceiling System Overview Main Features and Functions EchoCare Technologies Ltd. Confidential and Proprietary Information Echo System UG and Product Specifications 4 Release 2.0, April 2023 1.2 Main Features and Functions The EchoCare monitoring system, with its “ECHO” device, has unique and innovative capabilities of identifying various situations that could involve a physical or health risk for the monitored person. In combination with the system cloud – “EchoCloud”, web dashboards and a mobile application, the system can immediately alert on such detected situations. It also gives relevant indications about the person’s status and about any identified abnormalities. Yet, the system does not apply any video means, so that the privacy and intimacy of the monitored person is fully respected. The EchoCare monitoring technology applies very low power RF signals, about 1000 times lower than mobile handset RF power, yet can “see” through walls under certain conditions. The EchoCare monitoring technology further uses Edge processing (that is, performed within the end device, not remotely). This means that data analysis is done by the monitoring ECHO device, so that decisions on emergency events and other situations are reached immediately, and are independent of latency caused by the communication link to a cloud server. Moreover, all the necessary data and decisions for real time events are stored within the ECHO device, not relying on a remote storage facility. 1.2.1 The ECHO System Capabilities The ECHO system tracks four indicators of the monitored person – location, posture, motion and respiration, based on which it is able to: • Detect and provide various indications in real time − Person's location within the apartment and the presence of visitors − Out of Home / Out of Room indication • Detect and provide emergency alerts in real time − Moderate fall, Acute fall, Fall from bed − Hyperventilation − Drowning in bathtub • Detect and provide abnormal status alerts − Sedentary condition or Lying on the floor for 3 minutes by default (can be adjusted per customer request at 0.5 minute steps) − Risk of drowning • Perform respiration measurements − Measuring respiration parameters and recording respiration patterns • Provide Daily Living Activity reports − Location distribution − Gait measurements − Per-hour activity statistics System Overview Main Features and Functions EchoCare Technologies Ltd. Confidential and Proprietary Information Echo System UG and Product Specifications 5 Release 2.0, April 2023 1.2.2 System Use Cases The system is intended for the following use cases: • Aging in Place – monitoring persons in the apartment where they live, or monitoring only part of the apartment, using either a single ECHO device or multiple devices for appropriate coverage of the entire space; special cases may be monitoring the bedroom or bathroom area only. • Assisted Living / Skilled Nursing Facilities – using a single device per resident room • Remote Patient Monitoring – using a single device installed above the patient's bed 1.2.3 Display Example - Caregiver Dashboard The Caregiver Dashboard (normally used by the person’s caregiver or by his/her family) displays each resident’s information on a dedicated tile showing his/her instantaneous location and emergency events if applicable, as shown in Figure 1. The example figure shows the following cases: • a resident who has had an acute fal…

Text truncated - open the document above for the full version.

Attestation Statements

Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_02 15-02-2023 Certification Application Attestation Statements EchoCare Technologies Ltd. 5 Golda-Meir St. 7403649 Ness-Ziona ISRAEL Subject: FCC ID: 2BAUTECT1310PC To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) EchoCare Technologies Ltd. certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) [Insert Company Name Here] (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 30-May-2023 City: Ness-Ziona Name (2) : Rafi Zack Function: (CEO) 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” Covered list attestation FCC application letter Kiwa Page 2 of 2 RF_755_02 15-02-2023 Telephone number: + 972-8-613-3338 Email address: [email protected] Signature: Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvM 02 1 15-02-2023 Changed Applicant to Company and added “Subject: FCC ID: “ RvdM Issued/modified by : Richard van de Meer Function : Certification assessor Revision : 02 Date : 15-02-2023 Verified by : Willem Jan Jong Function : Team Lead Date : 16-02-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 19-02-2023

Attestation Statements

EchoCare Technologies Ltd. 5 Golda-Meir St. Ness-Ziona ISRAEL 7403649 Tel: +972-8-613-3338 V02072023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03/05/2023 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: 2BAUTECT1310PC EchoCare Technologies certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. EchoCare Technologies accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance consulting, LLC dba iCertifi FCC FRN: 0033399411 Address: 1001 SW Disk Drive, Suite 250, Bend, Oregon 97702 Contact Person: Paul Preston Tel: 866-885-4575 Email: [email protected] Sincerely, EchoCare Technologies Americas Compliance Consulting LLC dba iCertifi Rafi Zack Paul Preston EchoCare Technologies Ltd. 5 Golda-Meir St. Ness-Ziona ISRAEL 7403649 Tel: +972-8-613-3338 V02072023 Signature

Cover Letter(s)

May 30, 2023 Telefication B.V. Attn: Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Application for certification for a Remote Home Care Monitoring System, FCC ID: 2BAUTECT1310PC Dear Gentlemen, Please find attached our application for certification for a Remote Home Care Monitoring System, FCC ID: 2BAUTECT1310PC, prepared in accordance with FCC Rules, parts 2 and 15, section 15.517. The product testing and this application for certification were performed by Hermon Laboratories, which is recognized and accredited by FCC, Test Firm Registration Number is 927748, Designation Number is IL1001. Hermon Labs responsible person is Mr. Michael Nikishin, tel: +972 4626 8440, fax:+972 4628 8277, e-mail: [email protected]. We hope this application satisfies your requirements. Please send an invoice to Hermon Labs. Rafi Zack, CEO EchoCare Technologies Ltd.

Cover Letter(s)

RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 Declaration of Authorization We Name: EchoCare Technologies Ltd. Address: 5 Golda Meir St. . City: Ness-Ziona , 7403649. Country: Israel. Declare that: Name Representative of agent: ............. (1) Agent Company name: Hermon Laboratories Ltd. Address: Harakevet Industrial Zone City: Binyamina 30500 Country Israel. is authorized to apply for Certification of the following product(s): Product description:  Remote Home Care monitoring system . Type designation:  ECT-1310PC . Trademark: . Validity/ expiry date May 30, 2024 on our behalf. Date:  May 30, 2024.. City:  Ness Ziona .. Name:  Rafi Zack .. (2) Function: ...... CEO ............. Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent. Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 02 1 02-01-2023 History sheet added AG Issued/modified by : Axel Gase Function : Quality Manager Revision : 02 Date : 02-01-2023 Verified by : Willem Jan Jong Function : Team Lead Date : 02-01-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 02-01-2023

Cover Letter(s)

EchoCare Technologies Ltd. 5 Golda-Meir St. Ness-Ziona ISRAEL 7403649 Tel: +972-8-613-3338 EchoCare Technologies Ltd. Proprietary and Confidential information To Whom it may concern Declaration The EchoCare’s system, ECT-1310PC, is an indoor system that transmits a UWB signal in a Time-division duplexing (TDD) mode. The transmission duty cycle is 0.025. That means, the system transmits the info for 670pSec (Transmission period). The information is transmitted every 40nSec. The device receives information during the transmission off (i.e. during the following 40nSec). Sincerely yours Rafi Zack, CEO EchoCare Technologies Ltd.

Cover Letter(s)

FCC, Request for non-disclosure Date: 02-01-2022 RF_501, Issue 10 Company Name: EchoCare Technologies Ltd. Address: 5 Golda Meir St. City: Ness-Ziona , 7403649, Country: Israel To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: 2BAUTECT1310PC Reference number: 49449 Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: in order to avoid exposed of the technology to the competitors Date: 30-May-23 Name and signature of applicant: Rafi Zack Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! FCC, Request for non-disclosure Date: 02-01-2023 RF_501, Issue 10 Page 1 of 1 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period FCC, Request for non-disclosure Date: 02-01-2023 RF_501, Issue 10 Page 1 of 1 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 10 1 02-01-2023 History sheet added AG Issued/modified by : Axel Gase Function : Quality Manager Revision : 10 Date : 02-01-2023 Verified by : Willem Jan Jong Function : Team Lead Date : 02-01-2023 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 02-01-2023

Cover Letter(s)

May 12, 2023 To Whom It May Concern: Hermon Laboratories is currently undergoing a renewal assessment with the American Association for Laboratory Accreditation (A2LA). The on-site renewal assessment is scheduled for July 2023. Upon successful assessment, completion of necessary corrective actions, and review by A2LA staff, the renewal of accreditation for certificates 0839.01, 0839.03, 0839.04, and 0839.05 will be granted through May 31, 2025. However, in the meantime, the A2LA accreditation of Hermon Laboratories (0839.01, 0839.03, 0839.04, 0839.05) has been extended until August 31, 2023. Sincerely, Ryan Kidwiler Electrical Program Manager Email: [email protected]

External Photos

FCC ID: 2BAUTECT1310PC Page 1 of 3 EXTERNAL PHOTOGRAPHS FCC ID: 2BAUTECT1310PC Page 2 of 3 ECT-1310PC Front view FCC ID: 2BAUTECT1310PC Page 3 of 3 Rear view

ID Label/Location Info

40 mm 60mm EchoCare Technologies Ltd. Model: ECT-1310PCRev: 5.0 MAC Address: S/N: 230000XXX 005-102257 201-135370 Th is devi ce complies with Part 15F of the F CC Rules Operation is subjected to the following two conditions: (1) Th is device may not harmful interference, and (2) Th is device must accept any interference received, including i nterference that may caus e undesired operation. www.echocare-tech.com FCC ID: 2BAUTECT1310PC Contain: FCC ID: Z64-WL18SBMOD R Do not use outdoors Docking Input voltage: 100-240VAC / 0.1A (50-60Hz) Device Input voltage: 5VDC / 2A The device complies with CE Safety

Internal Photos

FCC ID: 2BAUTECT1310PC Page 1 of 3 INTERNAL PHOTOGRAPHS FCC ID: 2BAUTECT1310PC Page 2 of 3 ECT-1310PC Front view FCC ID: 2BAUTECT1310PC Page 3 of 3 Rear view

RF Exposure Info

FCC ID: 2BAUTECT1310PC Page 1 of 2 Environmental evaluation and exposure limit according to FCC CFR 47part 1, §1.1307, §1.1310 The Remote Home Care Monitoring System unit is classified as a mobile device. The Home unit includes transmitter operating in 6000 – 8500 MHz according to FCC part 15 subpart F section 15.517 and Wi-Fi / BLE module approval under FCC ID: Z64-WL18SBMOD. BLE band not in use in Remote Home Care Monitoring System (as indicated in Operational Description on Page 6). The UWB device and the Wi-Fi module can work together. Limit for power density for general population/uncontrolled exposure is 1mW/cm 2 for 1500 -100000 MHz frequency range. The power density P (mW/cm 2 ) = P T / 4 r 2 , where PT is the transmitted power, which is equal to the peak transmitter output power -11.84dBm plus maximum antenna gain 4dBi, the maximum equivalent isotropically radiated power EIRP is PT = -11.84dBm + 13dBi* = 1.16dBm = 1.306mW -11.84 dBm is the EUT maximum output power with the tune up tolerance, 13 dBi – total antenna gain, which is equal to GANT + 10 log (4 Antenna arrays x 2 TX Antenna) . The power density at 20 cm (minimum safe distance, required for mobile devices), calculated as follows: 1.306mW / 4 (20 cm) 2 = 0.0026mW/cm 2 << 1mW/cm 2 Maximum conducted power given in FCC ID: Z64-WL18SBMOD module grant for band 2412 – 2462 MHz is 243.8mW (23.87dBm). Limit for power density is 1mW/cm2 for 1500 -100000 MHz for general population/uncontrolled exposure. The gain of antennas used with the module are 3.2dBi. The maximum equivalent isotropic radiated power EIRP is for band 26: PT = 23.87dBm + 3.2dBi = 27.07 dBm = 509.33mW FCC ID: 2BAUTECT1310PC Page 2 of 2 The power density at 20 cm (minimum safe distance, required for mobile devices), calculated as follows: 509.33mW / 4 (20 cm) 2 = 0.10137mW/cm 2 << 1mW/cm 2 Assessment of RF hazard from UWB and Wi-Fi wireless module S1/limit + S2/limit ≤ 1, i.e 0.0026/1 + 0.10137/1 = 0.0026 + 0.10137 = 0.10397 ≤ 1 The aggregate ratio of transmit power to the relevant power limits does not exceed 100% and meets the safety requirements.

Test Report

EchoCare Technologies Proprietary and Confidential Information 1 X-Band UWB Antenna Spec EchoCare Technologies Proprietary and Confidential Information E-Plane 2 Frequency: 9.5 EchoCare Technologies Proprietary and Confidential Information H-Plane 3 Frequency: 9.5 EchoCare Technologies Proprietary and Confidential Information E-Plane 4 Frequency: 8 EchoCare Technologies Proprietary and Confidential Information E-Plane 5 Frequency: 8.75 EchoCare Technologies Proprietary and Confidential Information E-Plane 6 Frequency: 9.5 EchoCare Technologies Proprietary and Confidential Information 7 Thank You www.echocare-tech.com

Test Report

Hermon Laboratories Ltd. P.O. Box 23, Binyamina 3055001, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 43 Report ID: ECHRAD_FCC.49449.docx Date of Issue: 1-Jun-23 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC CFR 47 Part 15 subpart F, section 15.517 and subpart B; FOR: EchoCare Technologies Ltd. Remote Home Care Monitoring System Model: ECT-1310PC FCC ID: 2BAUTECT1310PC This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: ECHRAD_FCC.49449.docx Date of Issue: 1-Jun-23 Page 2 of 43 Table of contents 1 Applicant information ..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details .................................................................................................................................................................... 3 5 Tests summary .............................................................................................................................................................. 4 6 EUT description ............................................................................................................................................................. 5 6.1 General information ....................................................................................................................................................... 5 6.2 Test configuration .......................................................................................................................................................... 5 6.3 Changes made in EUT .................................................................................................................................................. 5 6.4 Transmitter characteristics ............................................................................................................................................ 6 7 Transmitter tests according to 47CFR part 15 requirements ......................................................................................... 7 7.1 Occupied bandwidth test ............................................................................................................................................... 7 7.2 Peak power within 50 MHz bandwidth and Radiated power density ............................................................................. 9 7.3 Radiated spurious emission measurements ................................................................................................................ 14 7.4 Conducted emissions .................................................................................................................................................. 24 8 Emission tests according to 47CFR part 15 subpart B requirements .......................................................................... 28 8.1 Conducted emissions .................................................................................................................................................. 28 8.2 Radiated emission measurements .............................................................................................................................. 32 9 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 36 10 APPENDIX B Test equipment correction factors ......................................................................................................... 37 11 APPENDIX C Measurement uncertainties .................................................................................................................. 41 12 APPENDIX D Test laboratory description ................................................................................................................... 42 13 APPENDIX E Specification references........................................................................................................................ 42 14 APPENDIX F Abbreviations and acronyms ................................................................................................................. 43 Report ID: ECHRAD_FCC.49449.docx Date of Issue: 1-Jun-23 Page 3 of 43 1 Applicant information Client name: EchoCare Technologies Ltd. Address: 5 Golda Meir St. Ness-Ziona 7403649, Israel Telephone: +972 54 543 4503 E-mail: [email protected] Contact name: Mr. Rafi Zack 2 Equipment under test attributes Product name: Remote Home Care monitoring system Product type: Transceiver Model(s): ECT-1310PC Trade Mark: Serial number: N.A. Hardware version: Rev 5 Software release: N.A. Receipt date 11-Dec-22 3 Manufacturer information Manufacturer name: EchoCare Technologies Ltd. Address: 5 Golda Meir St. Ness-Ziona 7403649, Israel Telephone: +972 54 543 4503 E-Mail: [email protected] Contact name: Mr. Rafi Zack 4 Test details Project ID: 49449 Location: Hermon Laboratories Ltd. P.O. Box 23, Binyamina 3055001, Israel Test started: 17-Jan-23 Test completed: 20-Mar-23 Test specification(s): FCC CFR 47 Part 15 subpart F, section 15.517 and subpart B, Report ID: ECHRAD_FCC.49449.docx Date of Issue: 1-Jun-23 Page 4 of 43 5 Tests summary Test Status Transmitter characteristics FCC section 15.519(b), Occupied b…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2BAUTECT1310PC Page 1 of 5 SETUP PHOTOGRAPHS This document contains 6 photographs FCC ID: 2BAUTECT1310PC Page 2 of 5 Photograph No.1 Carrier field strength and OBW measurement setup FCC ID: 2BAUTECT1310PC Page 3 of 5 Photograph No.2 Spurious emissions measurement setup in the anechoic chamber below 30 MHz FCC ID: 2BAUTECT1310PC Page 4 of 5 Photograph No.3 Spurious emissions measurement setup in the anechoic chamber in 30 -1000 MHz FCC ID: 2BAUTECT1310PC Page 5 of 5 Photograph No.4 Spurious and band edge emissions measurement setup in the anechoic chamber above 1 GHz

Contact Information

Applicant

Rafi Zack
[email protected]+ 972-8-613-3338Fax: + 972-8-613-3339

Technical Contact

Hermon Laboratories Ltd.Michael Nikishin
[email protected]972 4626 8440

Harakevet Industrial zone, P.O.Box 23 · Israel

Non-Technical Contact

EchoCare Technologies Ltd.Rafi Zack
[email protected]972-8-613-3338

Test Firm

Hermon Laboratories Ltd.George Shleimovich
[email protected]97246268468Fax: +972 4 626 8469

Technical Specifications

#Rule PartsFrequency RangePower Output
115F8.00 GHz - 9.50 GHz-
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. Device is restricted to indoor use only. The device with its antenna must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with operating conditions for satisfying RF exposure compliance. Only indoor operation. Operation onboard an aircraft, a ship or a satellite is prohibited.