Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SPECIFICATION Welcome! We are excited to introduce you to your new BIOS SkyV iewTM Wellness Table Lamp. BIOS SkyV iewM is the first table lamp of its kind to merge beauty and science with our patented BIOS SkyBlue circadian technology developed by NASA scientists. Each lamp is uniquely yours, featuring hand-blown glass and a carefully crafted billet aluminum base We invite you to experience the biological benefits of natural light indoors including: We would like to offer you a 1: 1 virtual meeting with us to learn more about the science, technology and design behind BIOS SkyV iewTM. Please look out for your email invitation, or reach out to schedule a meeting directly. Modes and Brightness Note: When first plugged into the wall, the lamp will automatically cycle through a 30-minute Sunrise To override this initial setting and preview all the modes - Sunrise, Daytime, Sunset, Nighttime- simply press down on the dial every time you want to transition. Each Sunrise and Sunset are dynamic and take a full 2 minutes. APP Manual Use Your lamp can be used manually before it is connected to the BIOS Lighting App. To provide the bestmanual experience, we recommend the following schedule: . When you ar When you are just starting the day, set to Sunrise . Leave your lamp on "Daytime" throughout the day . Transition to "Sunset" two hours before you go to bed- "Sunset" will automatically transition to "Nighttime" . Power off once you are going to bed Dimension Parameter 1. Input Voltage: AC100-240V 50/60Hz 2. Power: 25W 3. Output Voltage:DC24V 1.5A 4. LED SOURCES: UVA *3PCS ; B *7PCS;TW*35PCS;NT*7PCS;BS*14PCS;LED*14PCS;R*7PCS Encoder Insrtruction 5. On/Off οΌ Short press the encoder to turn on or off the lamp. 6. Change the mode : Long press the encoder for 3 seconds to change the light mode , that contains two modes for mode1 and mode2 ; mode 1 is NT source 100% , mode2 is BS source ,LED source,TW source ,B source and UVA source 100%. 7. Adjust the brightness of the light : simply turn the dial to the right to increase the brightness and to the left to decrease the brightness. 8. Pair the lamp οΌ Long press the encoder for 10 seconds , the lamp will flash for red ,and enter the network connection state. APP Instruction Product information interface Biorhythm information interface On/Off T imed count down Modes Sleeping PWM1(UVA):0 PWM2(B+TW):0 PWM3(BS+LED):0 PWM4(NT):100% PWM5(R):100% Working PWM1(UVA):0 PWM2(B+TW):100% PWM3(BS+LED):100% PWM4(NT):0 PWM5(R):0 Reading PWM1(UVA):0 PWM2(B+TW):0 PWM3(BS+LED):100 % PWM4(NT):100% PWM5(R):0 Relaxing PWM1(UVA):100% PWM2(B+TW):100% PWM3(BS+LED):100% PWM4(NT):100% PWM5(R):0 T imed Count down FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: β’ Reorient or relocate the receiving antenna. β’ Increase the separation between the equipment and receiver. β’ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. β’ Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 5/23/2023 U.S. Agent Designation BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BAZK-BHSKY): Contact Name: Wei Sun Company of U.S. agent: BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC Physical U.S. address of agent: 274 E EAU GALLIE BLVD STE 116 INDN HBR BCH Florida 32937 United States FRN of U.S. agent: 0033701699 Email address of U.S. agent: [email protected] BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC acknowledges their obligation to accept service of process on behalf of BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC. BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC with the FRN 0033701699 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under Β§ 2.911(d)(7). Sincerely, Signature Wei Sun VP BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC Signature Wei Sun VP BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC 48_[mo del] US_Agent_2.911(d)(7) - U, V04
Page 1 of 5 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9
Page 1 of 1 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L 3.0cm x W 2.0cm) Label Location Sky View Wellness Table Lamp Model: BH-SKY2-000-CBK001-1 FCC ID: 2BAZK-BHSKY
Page 1 of 2 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 2 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 BT/WIFI ANT
Page 1 of 5 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information FCC ID : 2BAZK-BHSKY EUT : Sky View Wellness Table Lamp Test Model : BH-SKY2-000-CBK001-1 Additional Model No. : BH-SKYX-YYY-MCCZSS-R (Where: X = Product Family Code (2-9), YYY = Product Code (000,001,002,003,004), M = Product Code (may be A-Z), CC = Color (BK=Black, WT=White, SL=Silver, GD=Gold), Z = Product Code(0-9), SS = Product Code(00-99), R = Revision (1-9)) Model Declaration : PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power Supply : For AC Adapter: Input:100-240V~, 50/60Hz, 1.2A Output: 24V1.5A, 36.0W Hardware Version : 1.0 Software Version : 1.0 Bluetooth : Frequency Range : 2402MHz-2480MHz Channel Number : 40 channels for Bluetooth V5.1 (DTS) Channel Spacing : 2MHz for Bluetooth V5.1 (DTS) Modulation Type : GFSK for Bluetooth V5.1 (DTS) Bluetooth Version : V5.1 Antenna Description : PCB Antenna, 2.21dBi(Max.) WIFI(2.4G Band) : Frequency Range : 2412MHz-2462MHz Channel Spacing : 5MHz Channel Number : 11 Channels for 20MHz bandwidth (2412~2462MHz) 7 Channels for 40MHz bandwidth (2422~2452MHz) Modulation Type : IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Description : PCB Antenna, 2.21dBi(Max.) Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Mobile Device 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commissionβs guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. Page 2 of 5 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is β€ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1β2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cmΒ²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 β 3.0 3.0 β 30 30 β 300 300 β 1500 1500 β 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cmΒ²) Averaging Time (minute) Limits for Occupational/Uncontrolled Exposure 0.3 β 3.0 3.0 β 30 30 β 300 300 β 1500 1500 β 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4ΟRΒ² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna Page 3 of 5 FCC ID: 2BAZK-BHSKY Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 5. Antenna Information EUT can only use antennas certificated as follows provided by manufacturer; Internal/External Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Notes Antenna PCB Antenna 2400-2500 MHz 2.21dBi BT/WIFI Antenna 6. Conducted Power [BT LE] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 00 240β¦
Text truncated - open the document above for the full version.
Page 1 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BT LE (Conducted Measurement) Product Name: Sky View Wellness Table Lamp Test Model: BH-SKY2-000-CBK001-1 Environmental Conditions Temperature: 23.8 ο° C Relative Humidity: 52.0% ATM Pressure: 100.0 kPa Test Engineer: Nick Peng Supervised by: Li Huan Page 2 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 1M 2402 Ant1 0.653 >=0.5 Pass NVNT BLE 1M 2440 Ant1 0.665 >=0.5 Pass NVNT BLE 1M 2480 Ant1 0.706 >=0.5 Pass Page 3 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz Ant1 -6dB Bandwidth NVNT BLE 1M 2440MHz Ant1 Page 4 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 1M 2480MHz Ant1 Page 5 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402 Ant1 3.12 30 Pass NVNT BLE 1M 2440 Ant1 3.25 30 Pass NVNT BLE 1M 2480 Ant1 2.71 30 Pass Page 6 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 1M 2402MHz Ant1 Power NVNT BLE 1M 2440MHz Ant1 Page 7 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 1M 2480MHz Ant1 Page 8 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Duty Factor (dB) Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 1M 2402 Ant1 -20.08 0 -20.08 8 Pass NVNT BLE 1M 2440 Ant1 -19.54 0 -19.54 8 Pass NVNT BLE 1M 2480 Ant1 -19.93 0 -19.93 8 Pass Page 9 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 1M 2402MHz Ant1 PSD NVNT BLE 1M 2440MHz Ant1 Page 10 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT BLE 1M 2480MHz Ant1 Page 11 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT BLE 1M 2402 Ant1 -52.37 -20 Pass NVNT BLE 1M 2480 Ant1 -51.73 -20 Pass Page 12 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Band Edge NVNT BLE 1M 2402MHz Ant1 Ref Band Edge NVNT BLE 1M 2402MHz Ant1 Emission Page 13 of 23 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industriβ¦
Text truncated - open the document above for the full version.
Page 1 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: Sky View Wellness Table Lamp Test Model: BH-SKY2-000-CBK001-1 Environmental Conditions Temperature: 23.8 ο° C Relative Humidity: 52.0% ATM Pressure: 100.0 kPa Test Engineer: Nick Peng Supervised by: Li Huan Page 2 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant1 7.201 >=0.5 Pass NVNT b 2437 Ant1 7.557 >=0.5 Pass NVNT b 2462 Ant1 8.034 >=0.5 Pass NVNT g 2412 Ant1 16.069 >=0.5 Pass NVNT g 2437 Ant1 15.322 >=0.5 Pass NVNT g 2462 Ant1 15.693 >=0.5 Pass NVNT n20 2412 Ant1 16.649 >=0.5 Pass NVNT n20 2437 Ant1 17.59 >=0.5 Pass NVNT n20 2462 Ant1 17.565 >=0.5 Pass NVNT n40 2422 Ant1 35.09 >=0.5 Pass NVNT n40 2437 Ant1 35.123 >=0.5 Pass NVNT n40 2452 Ant1 35.102 >=0.5 Pass Page 3 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2437MHz Ant1 Page 4 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT b 2462MHz Ant1 -6dB Bandwidth NVNT g 2412MHz Ant1 Page 5 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT g 2437MHz Ant1 -6dB Bandwidth NVNT g 2462MHz Ant1 Page 6 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2412MHz Ant1 -6dB Bandwidth NVNT n20 2437MHz Ant1 Page 7 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2462MHz Ant1 -6dB Bandwidth NVNT n40 2422MHz Ant1 Page 8 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n40 2437MHz Ant1 -6dB Bandwidth NVNT n40 2452MHz Ant1 Page 9 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT b 2412 Ant1 13.21 30 Pass NVNT b 2437 Ant1 13.78 30 Pass NVNT b 2462 Ant1 13.18 30 Pass NVNT g 2412 Ant1 12.7 30 Pass NVNT g 2437 Ant1 13.28 30 Pass NVNT g 2462 Ant1 12.96 30 Pass NVNT n20 2412 Ant1 10.6 30 Pass NVNT n20 2437 Ant1 10.88 30 Pass NVNT n20 2462 Ant1 12.5 30 Pass NVNT n40 2422 Ant1 11.16 30 Pass NVNT n40 2437 Ant1 11.2 30 Pass NVNT n40 2452 Ant1 11.11 30 Pass Page 10 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Duty Factor (dB) Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT b 2412 Ant1 -9.43 0 -9.43 8 Pass NVNT b 2437 Ant1 -10.28 0 -10.28 8 Pass NVNT b 2462 Ant1 -9.78 0 -9.78 8 Pass NVNT g 2412 Ant1 -15.23 0 -15.23 8 Pass NVNT g 2437 Ant1 -14.74 0 -14.74 8 Pass NVNT g 2462 Ant1 -12.85 0 -12.85 8 Pass NVNT n20 2412 Ant1 -17.23 0 -17.23 8 Pass NVNT n20 2437 Ant1 -16.4 0 -16.4 8 Pass NVNT n20 2462 Ant1 -17.37 0 -17.37 8 Pass NVNT n40 2422 Ant1 -20.56 0 -20.56 8 Pass NVNT n40 2437 Ant1 -20.74 0 -20.74 8 Pass NVNT n40 2452 Ant1 -20.86 0 -20.86 8 Pass Page 11 of 55 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EB Shenzhen LCSβ¦
Text truncated - open the document above for the full version.
Page 1 of 34 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC Sky View Wellness Table Lamp Test Model: BH-SKY2-000-CBK001-1 Additional Model No.: Please Refer to Page 6 Prepared for : BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC Address : 274 E EAU GALLIE BLVD STE 116 INDN HBR BCH, FL 32937 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : February 08, 2023 Number of tested samples : 2 Sample No. : A121222279-1, A121222279-2 Serial number : Prototype Date of Test : February 08, 2023 ~ February 27, 2023 Date of Report : February 27, 2023 Page 2 of 34 FCC ID: 2BAZK-BHSKY Report No.: LCSA121222279EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA121222279EA Date of Issue .................................. : February 27, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards β Partial application of Harmonised standards β‘ Other standard testing method β‘ Applicantβs Name ......................... : BIOLOGICAL INNOVATION AND OPTIMIZATION SYSTEMS LLC Address .......................................... : 274 E EAU GALLIE BLVD STE 116 INDN HBR BCH, FL 32937 Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No.................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This pβ¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 3 | 15C | 2.42 GHz - 2.45 GHz | 13.20 mW |