FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. renqiu xinmaizhong auto parts co.ltd/
  3. 2BAZM-XMZ2200B

2BAZM-XMZ2200BAir-warm Parking heater switch

renqiu xinmaizhong auto parts co.ltd
Air-warm Parking heater switch - FCC ID 2BAZM-XMZ2200B - renqiu xinmaizhong auto parts co.ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
May 28, 2023
Application Purpose
Original Equipment
Date of Application
May 28, 2023
Equipment Note
Air-warm Parking heater switch
Frequency Range
2402.00000000 - 2480.00000000
Company
renqiu xinmaizhong auto parts co.ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UPKey SetupKey ON/OFFKey DOWNKey RunModedeclaration TheAirHeaterhavemanualsettheoutputpowermodeandautomaticconstanttemperature mode,intheautomaticmodetheheaterbythetemperaturedifferencewithsettingand room,automaticadjusttheoutputpower.InthemanualmodetheadjustablepowerrangeforLevel 1~10,Intheautomaticmodethesettingtemperatureadjustablefor8~36°C(46.4°F~96.8°F) Instruction TurnON/OFFtheHeater:ClickedtheON/OFFKeytoturnONorOFFtheheater ChangetheRunMode:ClickedtheSetupKeytochangetherunmodefortheheater.itwell LoopatmanualModeandautomaticmode OutputpowerLevelorsettingtemperatureadjust:InthemanualmodebytheUPkeyand DOWNKeytoadjusttheoutputpower.assameintheautomaticmodebytheUPkeyand DOWNKeycanajdustthesettingtemperature; Remotecontrollerauthorization:whencontrollerOnstatus,pushedtheUPKeygreaterthan3s untillthedisplayershow“rte”,thenreleasetheUPKey.thenext,clickthekeyintheremote controlleranyone.whenthecontrollerautobacktooffstatus,itmeansauthorizationhas succeeded,otherwiserepeataboveoprateagain Clearmatchedremotecontrols:UnplugthecontrollerandpushedtheON/OFFkey,thenplugin thecontroller,untilthedisplayershow“CLr”,waitabout3sthedisplayershow“SUC”means succeed BluetoothPasswordsetup:thefirstruntheAirheaterBLEappopenthesetupdialoginthe passwordoptionsetnewpasswordsaveandexitthedialog.thenturnonthecontroller,nextatthe sametimepushedtheUPkeyandDOWNkeygreaterthan3suntillthedisplayershowEn00,then clicktheUPkeytoselecttoEn10andthedisplay“bLE”oncenterand4digtalnumber (default:1234)passwordinthetoprightcorner,nextpushedtheSETUPKeygreaterthan3s untillthepasswordisblinking.whendisplay“SUC”thenewpasswordsetupsucceed. TimeSetting:whencontrollerOnstatus,pushedSETUPkeygreaterthan3suntilldisplayer showF0onthetopletfcornerandtimeonthetoprightcornerofdisplayer.clickUPkeyor DOWNkeycanLoopeddisplayF0-F1-F2-F3 appointmenttime eg:07:00 Timerswitch eg:t-oF runningtime eg:05:00 Localtime eg:12:18 inaFxoptionclickedtheSETUPkeyintoeditmodeandclickedtheSETUPkeycanselecttheset option,clicktheON/OFFkeytoexiteditmode。intheeditmodethedisplayblinkthesetdata therunningtimesetrange0.5~10hour,setstep0.5hour。whileTimerswitchdisplayt-oFthe Timerisdisable,displayt-ontheTimerisenable. GetbluetoothID:whencontrollerOnstatus,pushedSETUPandON/OFFkeygreaterthan3s untilldisplayershow“”bLE”onthecenterandtheidnumberisdisplayedabove SelectLaugage:whencontrolleronOnstatus,pushedSETUPkeyandDOWNkeygreater3scan changethelanguageofthespeaker.It`swhileloopedatu-OF(mute)oru-En(Englist)oru- Ge(German)oru-Ru(Russian) Changethe°Cand°F:whencontrollerOnstatus,pushedSETUPkeygreaterthan3suntill displayershowF0onthetopleftcornerandtimeonthetoprightcornerofdisplayer.clicktheUP keytoshowF5.clicktheSETUPkeyintosetupmodeandclickUPkeyorDOWNkeycanchange the°Cor°F. ExecutepumpingFuelprogrammeindependent:whencontrolleronOFFstatusbyFirst poweronandPushedtheDOWNKeygreater7suntillthedisplayerdisplaydigital“300”then releasetheDOWNKey.atthesametimethepumpwillstarttopumpingthefuel.the displayerdisplaytheremaintime(Seconds)forthisprogramme.whentheremaintimelessthan “0”,thepumpingprogrammeover.clickedtheON/OFFkeycanhalttheprogramme. whenexecutethisprogrammeattentiondon`tpumpingtoomuchfuelintotheheater FaultCodeTable whentheheaterfails,thecorrespondinglogowillblinkinginthedisplayer,atthesametimethe faultcodedisplayinthedisplayer.thefaultcauseandsolutionrefertointhetablebelow Getapp ScantogetIOSapp orsearchairheaterble inappstore Scantodownloadandroidapporvisit https://www.booyood.com/app/airHeaterByBLE.apk Version:V1.0.0 LasteEditDate:2023.05.03CreateDate:2023.05.03 FCC Statement This equipment has been tested and found t o comply with t he limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Statement The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Attestation Statements

renqiu xinmaizhong auto parts co.ltd * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 4/25/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID:2BAZM-XMZ2200B FRN of applicant: 0033701749 Per section 2.911(d)(7) of the FCC rules, renqiu xinmaizhong auto parts co.ltd certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Baihetian Innovative Solutions FCC Registration Number (FRN): 0033401605 Physical U.S. Company Address: 6837 Chase Rd, Dearborn, MI 48126, USA Contact Person: Kenneth Young Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: mengli sun Title: General manager Company Name: renqiu xinmaizhong auto parts co.ltd Date: 4/25/2023 Agent Signed: Signed: Printed name: Kenneth Young Title: Manager Company Name: Baihetian Innovative Solutions Date: 4/25/2023

ID Label/Location Info

SIZE: 10*30mm FCC ID:2BAZM-XMZ2200B

RF Exposure Info

FCC ID: 2BAZM-XMZ2200B RF Exposure evaluation According to 447498 D04 Interim General RF Exposure Guidance v01 ERP/EIRP = P T +G T −L C ERP/EIRP is the equivalent (or effective) radiated power [in same units as P T , typically dBW, dBm, or power spectral density (psd)], relative to either a dipole antenna (ERP) or an isotropic antenna (EIRP). P T is the transmitter output power, in dBW, dBm, or psd (power over a specified reference bandwidth). G T is the gain of the transmitting antenna, in dBd (ERP) or dBi (EIRP). L C is the signal attenuation in the connecting cable between the transmitter and the antenna, in dB. For BT EDR mode Frequency (MHz) Output power to antenna (dBm) Ant gain(dBi) EIRP(dBm) ERP(dBm) ERP(mw) Distance (cm) P th (mW) 2402 3.20 -3.68 -0.48 -2.63 0.55 0.5 2.8 ERP = EIRP −2.15 dB WORSE CASE 2.09mW<2.8mW Remark: Then SAR evaluation is not required

Test Report

Global United Technology Services Co., Ltd. Report No.: GTS2023030480F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 26 TEST REPORT Applicant: renqiu xinmaizhong auto parts co.ltd Address of Applicant: Dajiang Village, Liangzhao Town, Renqiu City, Hebei Province, China Manufacturer/Factory: renqiu xinmaizhong auto parts co.ltd Address of Manufacturer/Factory: Dajiang Village, Liangzhao Town, Renqiu City, Hebei Province, China Equipment Under Test (EUT) Product Name: Air -warm Parking heater switch Model No.: XMZ-2200B FCC ID: 2BAZM-XMZ2200B Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: April 12, 2023 Date of Test: April 13-24, 2023 Date of report issued: April 24, 2023 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 26 2 Version Version No. Date Description 00 April 24, 2023 Original Prepared By: Date: April 24, 2023 Project Engineer Check By: Date: April 24, 2023 Reviewer Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 26 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED PEAK OUTPUT POWER .................................................................................................. 11 7.3 20DB EMISSION BANDWIDTH ............................................................................................................ 12 7.4 CARRIER FREQUENCIES SEPARATION ................................................................................................ 13 7.5 HOPPING CHANNEL NUMBER ............................................................................................................ 14 7.6 DWELL TIME ..................................................................................................................................... 15 7.7 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ....................................................... 16 7.7.1 Conducted Emission Method ..................................................................................................... 16 7.7.2 Radiated Emission Method ........................................................................................................ 17 8 TEST SETUP PHOTO ............................................................................................................................ 26 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 26 Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 26 4 Test Summary Test Item Section in CFR 47 Result Antenna Requirement 15.203/15.247 (c) Pass AC Power Line Con…

Text truncated - open the document above for the full version.

Test Report

TestDate:2019.05.06 地址:深圳市宝安区67区洪浪北二路凌云大厦10楼 电话:17688988025陈先生www.RFsister.com 聚焦·开放·分享 JDY-23蓝牙 天线测试报告 -RFsister TestDate:2019.05.06 地址:深圳市宝安区67 区洪浪北二路凌云大厦10 楼 电话:17688988025陈先生www.RFsister.com 聚焦·开放·分享 1.ElectricalCharacteristics No.ItemSpecifications 1 WorkingCentralFrequency2450MHz 2 BandWidth ±75 MHz( 2400 ~2500MHz) 3 Gain -3.68dbi 4 V.S.W.R(in BW) ≤4.3 5 PolarizationLinear 6 AzimuthBeamwidthOmni-directional 7 Impedance阻抗50 2.Return Loss and Smith Chat Return Loss TestDate:2019.05.06 地址:深圳市宝安区67区洪浪北二路凌云大厦10楼 电话:17688988025陈先生www.RFsister.com 聚焦·开放·分享 V.S.W.R SmithChat TestDate:2019.05.06 地址:深圳市宝安区67区洪浪北二路凌云大厦10楼 电话:17688988025陈先生www.RFsister.com 聚焦·开放·分享 3.PhysicalTestEnvironment E5071C网络分析仪 4.Shapeoftheantenna Efficiency : TestDate:2019.05.06 地址:深圳市宝安区67区洪浪北二路凌云大厦10楼 电话:17688988025陈先生www.RFsister.com 聚焦·开放·分享 Hpattern Fre(Mhz)Maxgain(dB)Degree 2400(MHz)-6.79dB114.00deg 2450(MHz)-4.92dB112.00deg 2500(MHz)-4.07dB108.00deg TestDate:2019.05.06 地址:深圳市宝安区67区洪浪北二路凌云大厦10楼 电话:17688988025陈先生www.RFsister.com 聚焦·开放·分享 E1pattern Fre(Mhz)Maxgain(dB)Degree 2400(MHz)-5.29dB164.00deg 2450(MHz)-4.80dB160.00deg 2500(MHz)-4.87dB-20.00deg TestDate:2019.05.06 地址:深圳市宝安区67区洪浪北二路凌云大厦10楼 电话:17688988025陈先生www.RFsister.com 聚焦·开放·分享 E2pattern Fre(Mhz)Maxgain(dB)Degree 2400(MHz)-5.86dB174.00deg 2450(MHz)-4.78dB-70.00deg 2500(MHz)-3.68dB-68.00deg

Test Report

Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 52 1. Bandwidth 1.1 OBW 1.1.1 Test Result Mode TX Type Frequency (MHz) Packet Type ANT 99% Occupied Bandwidth (MHz) Verdict Result GFSK SISO 2402 DH5 1 0.902 Pass 2441 DH5 1 0.902 Pass 2480 DH5 1 0.899 Pass π/4-DQPSK SISO 2402 2DH5 1 1.164 Pass 2441 2DH5 1 1.171 Pass 2480 2DH5 1 1.165 Pass 8-DPSK SISO 2402 3DH5 1 1.175 Pass 2441 3DH5 1 1.177 Pass 2480 3DH5 1 1.171 Pass Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 52 1.1.2 Test Graph GFSK_DH5_LCH_2402MHz_Ant1_NTNV GFSK_DH5_MCH_2441MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 52 GFSK_DH5_HCH_2480MHz_Ant1_NTNV π/4-DQPSK_2DH5_LCH_2402MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 52 π/4-DQPSK_2DH5_MCH_2441MHz_Ant1_NTNV π/4-DQPSK_2DH5_HCH_2480MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 52 8-DPSK_3DH5_LCH_2402MHz_Ant1_NTNV 8-DPSK_3DH5_MCH_2441MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 52 8-DPSK_3DH5_HCH_2480MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 52 1.2 20dB BW 1.2.1 Test Result Mode TX Type Frequency (MHz) Packet Type ANT 20dB Bandwidth (MHz) Verdict Result GFSK SISO 2402 DH5 1 1.046 Pass 2441 DH5 1 1.042 Pass 2480 DH5 1 1.033 Pass π/4-DQPSK SISO 2402 2DH5 1 1.310 Pass 2441 2DH5 1 1.309 Pass 2480 2DH5 1 1.310 Pass 8-DPSK SISO 2402 3DH5 1 1.310 Pass 2441 3DH5 1 1.310 Pass 2480 3DH5 1 1.304 Pass Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 52 1.2.2 Test Graph GFSK_DH5_LCH_2402MHz_Ant1_NTNV GFSK_DH5_MCH_2441MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 52 GFSK_DH5_HCH_2480MHz_Ant1_NTNV π/4-DQPSK_2DH5_LCH_2402MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 52 π/4-DQPSK_2DH5_MCH_2441MHz_Ant1_NTNV π/4-DQPSK_2DH5_HCH_2480MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 52 8-DPSK_3DH5_LCH_2402MHz_Ant1_NTNV 8-DPSK_3DH5_MCH_2441MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 52 8-DPSK_3DH5_HCH_2480MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 52 2. Maximum Conducted Output Power 2.1 Test Result Mode TX Type Frequency (MHz) Packet Type Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit GFSK SISO 2402 DH5 3.20 <=20.97 Pass 2441 DH5 2.64 <=20.97 Pass 2480 DH5 1.91 <=20.97 Pass π/4-DQPSK SISO 2402 2DH5 2.76 <=20.97 Pass 2441 2DH5 1.26 <=20.97 Pass 2480 2DH5 0.92 <=20.97 Pass 8-DPSK SISO 2402 3DH5 1.31 <=20.97 Pass 2441 3DH5 1.29 <=20.97 Pass 2480 3DH5 1.02 <=20.97 Pass Report No.: GTS2023030480F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 14 of 52 2.2 Test Graph GFSK_DH5_LCH_2402MHz_Ant1_NTNV GFSK_DH5_MCH_2441MHz_Ant1_NTNV Report No.: GTS2023030480F01 Global Uni…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission Conducted Emission

Contact Information

Applicant

mengli sun(General manager)
[email protected]+86-18733774980Fax: +86-0317-2262336

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]86-0-755-2779-8480Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.09 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted.

Other Applications from renqiu xinmaizhong auto parts co.ltd

Air-warm Parking heater switch - FCC ID 2BAZM-XMZM4 - renqiu xinmaizhong auto parts co.ltd
2BAZM-XMZM4

Air-warm Parking heater switch

May 21, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter