This manual includes the information necessary for use of Nurugo CPR manikin. Be sure to read this manual carefully in advance for accurate and safe use of the manikin. ※ For more detailed information, check out the homepage of best CPR,Inc. at www.aed.kr. 1 INSTRUCTIONS FOR USE L360/L360B/L380/L380B Product overview The Nurugo seriesproducts are manikins for CPRtraining. Designed to provide advanced features, such asvisual and auditory feedbacks, the Nurugo seriesproducts improve the quality and efficiency of your CPR training. Features Refer to the following for the enhanced features of the Nurugo series products. •Thick and sturdy chest The chest part was designed for realistic, deep chest compressions over 5 cm. •Visible clavicles (collarbones) and extended skin Clavicles are clearly visible, and the skin is extended on the left side of the manikin for more precise AED pad placement. •Realistic neck design resembling human body -The head rotates 15° to left and right. -Double neck joints allow for vertical movements of the head. •Metronome-guided compression training Audible signals may be turned on (30 times,110 times/min rate) atanearly stage of compression to provide a guidance on thecompression rate. •Visual and auditory feedbacks Feedbacks through visual display and sound provide guidance and show the performance of a CPR training. Also, information about a full cycle of contraction and relaxation by chest compression is provided as well, for more effective CPR training. •Vertical pressure feedback and posture correction function -Application of tilt sensor inside mannequin.(patent registration) -You can correct the vertical compression posture of CPR -It is important to keep your arms straight and press them vertically to the ground. Product overview 2 Display Depth and rate of the chest compression are indicated. The color of the display changes according to the quality of a chestcompression. Battery cover Used to replace batteries. Refer to Replacing the batteries on page 8 for information about replacing the batteries. Extended skin for AED pad placement Extended skin provides a precise spot to attach the AED pad for a training of antero-lateral placement (middle-line from the armpit) Visual feedback switch Turns on or off the visual feedback feature. Language setting button Used to change languages. Languages will change in the following order each time you press the button. (KOR-ENG-CHN-JPN-GER-FRA-SPN-UAE-INA-VN) Volume setting button Used to adjust volume of speaker output. The audio volume will change in the order of (LOW- MEDI UM-HIGH) each time you press the button. Speaker Used to provide voice instructions and audio instructions/feedbacks. Metronome switch Turns on or off the metronome guide sound. Auditory feedback switch Turns on or off the auditory feedback feature. CPR clicker switch The CPR clicker is used to verify compression depth. It makes a “click” sound when the compression depth reaches 5 cm. You can turn it on or off by pushin g in or pulling out the switch. Product overview (in some models only) Product overview On Off (located under the skin, at the bottom of the product) 3 Utilizing the features (in some models only) Utilizing the features Performing feedback-guided compressions 1. Push the feedback button to turn on the feedback. 2. Perform compressions on the chest following the visual and auditory feedbacks. - The power LED and the forehead display will be turned on. - The following feedbacks will be provided. Refer to the following to utilize the enhanced features the Nurugo series products provide. 4 Indications Description Compression depth Green Compression depth is exactly 5cm ~6cm. Red Compression depth is not 5cm~6cm. Compression rate GreenCompression rate is 100~120 times/min. RedCompression rate is not 100~120 times/min. Indication Greenpressed vertically Rednot pressed vertically Voice instruction Description “Press it more deeply.” Compression depth is shallower than 5 cm. “Press it faster.” Compression rate is less than 100 times/min. “You are doing well.”Compressiondepth is 5cm~6 cm, and compression rate is over 100~120 times/min. “Press it a bit slowly.”When the Compression rate is over 120 times/min. “Press it a more deeply and slowly.” When the Compressiondepthislessthan5cm,andcompressionrateis over120times/min. “Relax the chest.” When the chest is not relaxed correctly. “Press down vertically” When chest compressions are not applied vertically to the center of the chest Utilizing the features (in some models only) Visual feedback The color of the displayed information will change according to the depth and rate of your compression. ※The latest AHA GUIDE recommends a compression rate of 100 to 120 times per minute. Accordingly, NURUGOevaluates the average value of 110 times asan appropriate compression rate. Auditory feedback Voice instructions will be provided to inform you of the current CPR status and what you have to do to successfully complete the CPR session. Utilizing the features 5 Utilizing the features (in some models only) 2. Perform compressions to the metronome signals. - Audible signals will be output at a rate of 110 times/min. -The metronome signal will sound 30 times at a rate of 110 times/min, then it will turn off automatically. -You can push the metronome button again to turn the signal sound on. Performing metronome-guided compressions 1. Push the metronome button to turn on the metronome. Utilizing the features 6 Note •The visual feedbackfeature of your Nurugo manikin will enter standbymode if no chestcompressionis detectedfor 30 seconds. •While in standby mode, the visual feedbackoperation will automatically resumewhen it senses compressionson the chest. •The power indicator will blink if the battery is low, and a voice instruction will be made. (“The batteriesis low. Pleasereplace it with the new one.”) Referto Replacing the batterieson page 8for information about replacing batteries. Utilizing the features …
Text truncated - open the document above for the full version.
bestCPR, Inc. August 17, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (2BB24‐NURUGOL380B) [bestCPR, Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Jiho, Choi / Manager bestCPR, Inc. August 17, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (2BB24‐NURUGOL380B) [bestCPR, Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Jiho, Choi / Manager
V02072023 Manufacturers Letterhead Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 18, 2023 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: 2BB24-NURUGOL380B bestCPR, Inc. certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. bestCPR, Inc. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission- related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance consulting, LLC dba iCertifi FCC FRN: 0033399411 Address: 1001 SW Disk Drive, Suite 250, Bend, Oregon 97702 Contact Person: Paul Preston Tel: 866-885-4575 Email: [email protected] Sincerely, bestCPR, Inc. Americas Compliance Consulting LLC dba iCertifi Jiho Choi Paul Preston
bestCPR, Inc. 273-277, KyeongDongMirwellCity, 741, Taejang-ro, Gimpo-si, Gyeonggi-do, Republic of Korea Date: August 17, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (NURUGO/NURUGO L380B # 2BB24- NURUGOL380B#) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (below list) required to be submitted with this application be permanently withheld from public review. Permanent Confidential Request -. Schematics -. Block Diagram -. Operational Description SPECIFY REASON FOR REQUEST (i.e. the above documents are company proprietary information that could never get into the possession of your competition). Please contact me if there is any information you may need. Sincerely, Jiho, Choi / Manager
bestCPR, Inc. 273-277, KyeongDongMirwellCity, 741, Taejang-ro, Gimpo-si, Gyeonggi-do, Republic of Korea Date: August 17, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (NURUGO/NURUGO L380B # 2BB24- NURUGOL380B#) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (below list) required to be submitted with this application be short-term Confidentiality for a period of 180 days after grant is issued. Short-Term Confidential Request -. External Photos -. Internal Photos -. Test set-up photo -. User Manual SPECIFY REASON FOR REQUEST (i.e. These documents contain detailed system and equipment descriptions and related information about the product, which we considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, we feel that this information would be of benefit to our competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Jiho, Choi / Manager
bestCPR, Inc. 273-277, KyeongDongMirwellCity, 741, Taejang-ro, Gimpo-si, Gyeonggi-do, Republic of Korea Date: August 17, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Ms. Chloe Lee/Deputy General Manager of Eurofins KCTL Co.,Ltd. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Sincerely, Jiho, Choi / Manager
bestCPR, Inc. #273~#277, KyeongDongMirwellCity, 741, Taejang-ro, Gimpo-si, Gyeonggi-do, Republic of Korea Tel +82-31-385-7272 / Fax +82-31-385-3999 Date: August 17, 2023 Dear Sir/Madam, Re: Letter of Similarity We, bestCPR, Inc. declare the differences for between original model and variant models. -Product : NURUGO -Model name : NURUGO L380B -Variant Model name : NURUGO L360B Differences in language support provided, product hardware is the same, not different. Sincerely Yours, _________ NAME : Jiho, Choi TITLE : Manager E-MAIL: [email protected] bestCPR, Inc.
This document shall not be reproduced, except in full, without the written approval External photos of EUT This document shall not be reproduced, except in full, without the written approval This document shall not be reproduced, except in full, without the written approval
Basic Model Label Variant Mod el Label Label Location The rear of device
This document shall not be reproduced, except in full, without the written approval Internal photos of EUT This document shall not be reproduced, except in full, without the written approval This document shall not be reproduced, except in full, without the written approval This document shall not be reproduced, except in full, without the written approval Chip Antenna in RF Module This document shall not be reproduced, except in full, without the written approval This document shall not be reproduced, except in full, without the written approval This document shall not be reproduced, except in full, without the written approval This document shall not be reproduced, except in full, without the written approval This document shall not be reproduced, except in full, without the written approval
This test report shall not be reproduced, except in full, without the written approval * RF Exposure FCC ID: 2BB24-NURUGOL380B 1. Regulation According to the KDB 447498 D01 V06, the following RF exposure evaluation shall to demonstrate RF exposure compliance. Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified, typically in the SAR measurement or SAR analysis report, by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting are required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops and tablets, etc. a) For 100 ㎒ to 6 ㎓ and test separation distances ≤ 50 ㎜, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, ㎽) / (min. test separation distance, ㎜)] ꞏ [√f(㎓)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR,30 where ● f(㎓) is the RF channel transmit frequency in ㎓ ● Power and distance are rounded to the nearest ㎽ and mm before calculation ● The result is rounded to one decimal place for comparison ● The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 ㎜, and for transmission frequencies between 100 ㎒ and 6 ㎓. When the minimum test separation distance is < 5 ㎜, a distance of 5 ㎜ according to 4.1 f) is applied to determine SAR test exclusion. b) For 100 ㎒ to 6 ㎓ and test separation distances > 50 ㎜, the 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B): 1) {[Power allowed at numeric threshold for 50 ㎜ in step a)] + [(test separation distance – 50 ㎜)ꞏ(f(㎒)/150)]} ㎽, for 100 ㎒ to 1500 ㎒ 2) {[Power allowed at numeric threshold for 50 ㎜ in step a)] + [(test separation distance – 50 ㎜)ꞏ10]} ㎽, for > 1500 ㎒ and ≤ 6 ㎓ c) For frequencies below 100 ㎒, the following may be considered for SAR test exclusion (also illustrated This test report shall not be reproduced, except in full, without the written approval in Appendix C): 1) For test separation distances > 50 ㎜ and < 200 ㎜, the power threshold at the corresponding test separation distance at 100 ㎒ in step b) is multiplied by [1 + log(100/f(㎒))] 2) For test separation distances ≤ 50 ㎜, the power threshold determined by the equation in c) 1) for 50 ㎜ and 100 ㎒ is multiplied by ½ 3) SAR measurement procedures are not established below 100 ㎒. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any SAR test results below 100 ㎒ to be acceptable. 2. Result 2-1. Calculation Result of RF Exposure Mode Test frequency [㎒] Max. tune-up Power [㏈m] Conducted output power [㎽/] Min. test separation distance [㎜] SAR test exclusion thresholds ≤ 7.5 for 10-g SAR BLE/1 Mbps 2 440 -1.00 0.79 5.00 0.25 Note: 1. SAR test exclusion thresholds = [(max. power of channel, including tune-up tolerance, ㎽)/(min. test separation distance, ㎜)] ꞏ [√f(㎓)] = [(0.79)/(5)] ꞏ [√2.402] = 0.25 3. Target power and tolerance, Max tuneup power Mode Test frequency [㎒] Target power [㏈m] Max tuneup power [㏈m] Measured average Power [㏈m] Bluetooth LE_1 Mbps 2402 -2.00 -1.00 -2.51 2440 -2.00 -1.00 -1.79 2480 -2.00 -1.00 -1.25 4. RF Exposure Compliance Issue Therefore, EUT is not required the SAR Evaluation.
F1media 2.4GHz SMD Antenna F0403 1. Features • Designed for 2.4GHz applications: BT / BLE, Wi-Fi ® (802.11a/b/g/n), ZigBee ® . • Low profile design • High efficiency • Lightweight • Intended for SMD mounting • Supplied in tape and reel 2. Description F0403 is intended for use with all 2.4 GHz applications. The antenna uses a ground plane in order to radiate efficiently, but this ground plane must not extend underneath the antenna itself. Ideal for small wearables. 3. Applications •Mobile phones • PDAs • PNDs • Headsets • PMPs / MP3s • Laptops • PC-Cards • Medical devices • Sensors F1media 2.4GHz SMD Antenna F0403 4. Part Number F1-FR4 ANT : F0403 5. General Data Product name F1-FR4 ANT Part Number F0403 Frequency 2.4 – 2.5GHz Polarization Linear Operating temperature -40°C to140°C Impedance with matching 50 Ω Weight <0.03g Antenna type SMD Dimensions 4 x 3 x 1.1 (mm) 6. RF Characteristics 2.4 – 2.5 GHz Peak gain 0.8dBi Average gain (Linear) -1.9dBi Average efficiency 65% Maximum return loss <-10dB Maximum VSWR 2:1 All data measured on F1media co,. Ltd evaluation PCB Part No. F0403 Ant for Wireless Applications F1media 2.4GHz SMD Antenna F0403 7. RF Performance 7.1 Return Loss 7.2 VSWR F1media 2.4GHz SMD Antenna F0403 7.3 Antenna pattern 7.3.1 2400 MHz – 2500 MHz 3D pattern at 2450 MHz F1media 2.4GHz SMD Antenna F0403 F1media 2.4GHz SMD Antenna F0403 F1media 2.4GHz SMD Antenna F0403 ntennas for Wireless Applications F1media 2.4GHz SMD Antenna F0403 8. Antenna Dimensions F1media:F0403 Top side Bottom Side 3 solder pads (1.0 x 0.8 mm) All Dimensions in (mm) F1media 2.4GHz SMD Antenna F0403 9. Schematic symbol and Pin definition The circuit symbol for the antenna is shown below. The antenna has 5 pins with only two as functional. All other pins are for mechanical strength. Pin Description 1,2 Feed 3 Not used (Mechanical only) 10. Antenna footprint The recommended host PCB footprint is below. F1media 2.4GHz SMD Antenna F0403 11. Electrical Interface 11. 1 Transmission Line All transmission lines should be designed to have a characteristic impedance of 50Ω. • The length of the transmission lines should be kept to a minimum • Any other parts of the RF system like transceivers, power amplifiers, etc, should also be designed to have an impedance of 50 Ω Once the material for the PCB has been chosen (PCB thickness and dielectric constant), a coplanar transmission line can easily be designed using any of the commercial software packages for transmission line design. For the chosen PCB thickness, copper thickness and substrate dielectric constant, the program will calculate the appropriate transmission line width and gaps on either side of the track, so the characteristic impedance of the co-planar transmission is 50 Ω. 11.2 Matching Circuit The antenna requires a matching circuit that must be optimized for each product. The matching circuit will require up to 3 components and the following circuit should be designed into the host PCB. Not all components may be required but should be included as a precaution. The matching network must be placed close to the antenna feed to ensure it is more effective in tuning the antenna. Antennas for Wireless Applications F1media 2.4GHz SMD Antenna F0403 12. Antenna Integration Guide 12. 1 Antenna Placement F1media strongly recommends placing the antenna at the edge of the board. Maximum antenna performance is achieved by placing the antenna towards one of the corners of the PCB and with the feed point of the antenna as close to same corner of the PCB as possible. Additional ground and components near the antenna should be at a distance of at least 2 mm. Where possible the antenna should be clear of ground from both sides, although the antenna can work well with a minimum clearance of D ≥ 2 mm as shown in the drawing above. F1media 2.4GHz SMD Antenna F0403 13. Reference Board The reference board has been designed for the purpose of evaluating F0403 and includes an SMA female connector. F0403 Evaluation Board F1media 2.4GHz SMD Antenna F0403 14. Reference Board Matching Circuit Designator Type Value Description L1, L2 Inductor 2.2nH Murata LQG15HN series C1 Capacitor Not fitted Not fitted F1media 2.4GHz SMD Antenna F0403 15. Packaging 15.1 Optimal Storage Conditions Temperature -10ºC to 40ºC Humidity Less than 75% RH Shelf life 24 Months Storage place Away from corrosive gas and direct sunlight Packaging Reels should be stored in unopened sealed manufacturer’s plastic packaging. Note: Storage of open reels of antennas is not recommended due to possible oxidization of pads on antennas. If short term storage is necessary, then it is highly recommended that the bag containing the antenna reel is re-sealed and stored in like storage conditions as in above table. 18.2 Tape Characteristics F1media [Part Number: F0403] F1media 2.4GHz SMD Antenna F0403 15.3 Reel Dimensions
verify No.282330906470 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-5008-1021 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR23-SRF0204 Page (2) of (32) KCTL-TIR001-003/7 (220705) KP23-03182 REPORT REVISION HISTORY Date Revision Page No 2023-08-28 Originally issued - This report shall not be reproduced except in full, without the written approval of Eurofins KCTL Co.,Ltd. This document may be altered or revised by Eurofins KCTL Co.,Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by Eurofins KCTL Co.,Ltd. will constitute fraud and shall nullify the document. This test report is a general report that does not use the KOLAS accreditation mark and is not related to KS Q ISO/IEC 17025 and KOLAS accreditation. General remarks for test reports Statement concerning the uncertainty of the measurement systems used for the tests (may be required by the product standard or client) Internal procedure used for type testing through which traceability of the measuring uncertainty has been established: Procedure number, issue date and title: Calculations leading to the reported values are on file with the testing laboratory that conducted the testing. Statement not required by the standard or client used for type testing Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-5008-1021 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR23-SRF0204 Page (3) of (32) KCTL-TIR001-003/7 (220705) KP23-03182 CONTENTS 1. General information ...................................................................................................... 4 2. Device information ........................................................................................................ 4 2.1. Information about derivative model ......................................................................... 4 2.2 Frequency/channel operations ................................................................................... 5 2.3. Duty Cycle Factor ................................................................................................... 5 2.4. RF power setting in TEST SW ................................................................................. 5 3. Antenna requirement .................................................................................................... 6 4. Summary of tests .......................................................................................................... 7 5. Measurement uncertainty ............................................................................................. 8 6. Measurement results explanation example .................................................................. 9 7. Test results ................................................................................................................. 10 7.1. Maximum Peak Output Power .............................................................................. 10 7.2. Peak Power Spectral Density ............................................................................... 13 7.3. 6 ㏈ Bandwidth(DTS Channel Bandwidth) .......................................................... 15 7.4. Spurious Emission, Band Edge and Restricted bands .......................................... 17 7.5. Conducted Spurious Emission .............................................................................. 30 8. Measurement equipment ............................................................................................ 32 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-5008-1021 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR23-SRF0204 Page (4) of (32) KCTL-TIR001-003/7 (220705) KP23-03182 1. General information Client : bestCPR, Inc. Address : 273-277, KyeongDongMirwellCity 741, Taejang-ro, Gimpo-si Gyeonggi-do Republic of Korea Manufacturer : bestCPR, Inc. Address : 273-277, KyeongDongMirwellCity 741, Taejang-ro, Gimpo-si Gyeonggi-do Republic of Korea Laboratory : Eurofins KCTL Co.,Ltd. Address : 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea Accreditations : FCC Site Designation No: KR0040, FCC Site Registration No: 687132 VCCI Registration No. : R-20080, G-20078, C-20059, T-20056 CAB Identifier: KR0040 ISED Number: 8035A KOLAS No.: KT231 2. Device information Equipment under test : NURUGO Model : NURUGO L380B Derivative Model : NURUGO L360B Modulation technique : GFSK( Bluetooth Low Energy) Number of channels : 40 ch Power source : DC 6 V Antenna specification : Chip Antenna Antenna gain : 0.8 ㏈i Frequency range : 2 402 ㎒ ~ 2 480 ㎒(Bluetooth Low Energy) Software version : 1.0 Hardware version : 1.0 Test device serial No. : TEST01(Conducted) TEST02(Radiated) Operation temperature : -10 °C ~ 50 °C 2.1. Information about derivative model The difference between basic model and derivative models is: The basic and derivative model are electrically identical. The derivative model is only for the simplified difference based on supporting language. Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-5008-1021 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR23-SRF0204 Page (5) of (32) KCTL-TIR001-003/7 (220705) KP23-03182 2.2 Frequency/channel operations This device contains the following capabilities: Bluetooth Low Energy Ch. Frequency (㎒) 00 2 402 . . . . 19 2 440 . . . . 39 2 480 Table 2.3.1. Bluetooth Low Energy 2.3. Duty Cycle Factor Test mode Period (ms) On time (ms) Duty cycle Duty Cycle Factor (dB) (Linear) (%) 1M Bits/s, 37 Packet 0.625 0.394 0.630 5 63.05 2.00 Notes. 1. Duty cycle (Linear) = T on time / Period 2. DCF(Duty cycle factor) = 10log(1/duty cycle) 3. DCF is not compensated to average result if the duty cycle is more than 98% 1M Bits/s, 37 Packet 2.4. RF power setting in TEST SW Ch. Frequency (㎒) RF Power setting value So…
Text truncated - open the document above for the full version.
This document shall not be reproduced, except in full, without the written approval Test setup photos - Below 30 ㎒ (9 ㎑ ~ 30 ㎒) - Below 1 ㎓ (30 ㎒ ~ 1 ㎓) This document shall not be reproduced, except in full, without the written approval - Above 1 ㎓ (1 ㎓ ~ 18 ㎓) - Above 1 ㎓ (18 ㎓ ~ 26.5 ㎓) This document shall not be reproduced, except in full, without the written approval Conducted
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 880.00 µW |