Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Fairy Lee
C5266091_X24_Ed.2 1/1 Shenzhen GULIGULI Intelligent Technology Co.,Ltd “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen GULIGULI Intelligent Technology Co.,Ltd Grantee code: 2BB38 FCC ID: 2BB38-GR-W25 Contact Name: Wang Kuijun Address: 1/F Building C, 12 Huanzhen Rd., Bo Gang Industrial Zone, Shajing Town, Bao'an District, Shenzhen, China Telephone No: 0755-86168854 Fax No: 0755-86168854 Email: [email protected] i. [Shenzhen GULIGULI Intelligent Technology Co.,Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shenzhen GULIGULI Intelligent Technology Co.,Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Shenzhen GULIGULI Intelligent Technology Co.,Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered”equipment . Date: 2023/07/19 Applicant’s Name: Wang Kuijun Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
C5266091_X8_Ed.1 1/1 Letter of Authorization Shenzhen GULIGULI Intelligent Technology Co.,Ltd Company: Shenzhen GULIGULI Intelligent Technology Co.,Ltd Address: 1/F Building C, 12 Huanzhen Rd., Bo Gang Industrial Zone, Shajing Town, Bao'an District, Shenzhen, China Product Name: Hiibo Model Number: GR-W25 FCC Identifier: 2BB38-GR-W25 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Wang Kuijun Date: 2023.07.19 Title: Manager Signature of applicant:
C5266091_X10_Ed.2 1/1 Shenzhen GULIGULI Intelligent Technology Co.,Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2023-07-19 Subject: Request for Confidentiality FCC ID: 2BB38-GR-W25 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Wang Kuijun Title: Manager 2023.07.19
Page1of3ReportNo.:FCS202307024 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202307024 Photo3 Photo4 Page3of3ReportNo.:FCS202307024 Photo5 Photo6
LabelandLabelLocation FCCID:2BB38-GR-W25
Page1of5ReportNo.:FCS202307024 Internalphotos Photo1 Photo2 Page2of5ReportNo.:FCS202307024 Photo3 Photo4 Page3of5ReportNo.:FCS202307024 Photo5 Photo6 Page4of5ReportNo.:FCS202307024 Photo7 Photo8 Page5of5ReportNo.:FCS202307024 Photo9 Photo10
Page1of2ReportNo.:FCS202307024W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com FCCRFExposure EUTDescription:Hiibo ModelNo.:GR-W25 FCCID:2BB38-GR-W25 Equipmenttype:Mobileequipment Testproceduresaccordingtothetechnicalstandards:KDB447498D01V06andFCC2.1091. 1.Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactof humanexposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) F=frequencyinMHz Formula:Pd=(Pout*G)/(4*π*r 2 ) Where: Pd=powerdensityinmW/cm 2 , Pout=outputpowertoantennainmW; G=gainofantennainlinearscale, π=3.14; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantennaandthetotal powerinputtotheantenna,throughthecalculation,wewillknowthedistancerwheretheMPE limitisreached. 2.TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleand Page2of2ReportNo.:FCS202307024W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com highestchannelindividually. 3.TestResultofRFExposureEvaluation Modulation Channel Freq. (MHz) Conduct edpower (dBm) Max tune-up power (mW) Antenna Gain (dBi) Antenna gainnumeric Evaluation result (mW/cm2) Power density Limits (mW/cm2) 802.11b 241211.0612.762.161.640.0041651 243710.2310.542.161.640.0034401 246210.3810.912.161.64 0.003561 1 802.11g 241210.4511.092.161.64 0.003620 1 243710.3210.762.161.64 0.003512 1 246210.7811.972.161.64 0.003907 1 802.11n 24129.989.952.161.64 0.003248 1 24379.809.542.161.64 0.003114 1 24629.769.462.161.64 0.003088 1 Wifi:Conclusion:themaxresult:0.004165≤1.0compliancewithFCC'sRFExposure.
深圳市顺达成科技有限公司 SHENDACHENGELECTRONICSCO.,LTD 1 1 射频性能测量报告 RFPerformanceTestReport 天线测试设备简介 AntennaTestEquipmentIntroduction 测试天线输入特性使用AgilentE5071CandAgilent5062A矢量网络分析仪;辐射特性利 用广屏三维近场暗室进行测试,并分别使用8960E5515和AgilentE4438C进行了分析。暗房的测 试坐标如下: TestofantennainputcharacteristicsusingAgilentE5071CandAgilent5062Avectornetwork analyzer;Theradiationpatternoftheantennaaretestedusingtheguangping3DnearfieldAnechoicChamber, andtheinstrumentisusedtoagilent8960E5515andAgilentE4438C.Thetestcoordinatesofthedarkroom areasfollows: 1.S11参数测量/S11Parameter-VSWR 使用一根50Ω同轴电缆连接到天线,然后该电缆连接到网络分析仪测量S11参数,被测量产品远离金属至少 20厘米。 MeasuringMethodisa50Ωcoaxialcableisconnectedtotheantenna.Thenthiscableisconnectedtoanetworkanalyzer tomeasuretheS11parameter,Keepingthisfixtureawayfrommetalatleast20cm. S11Parameter-VSWR 深圳市顺达成科技有限公司 SHENDACHENGELECTRONICSCO.,LTD 2 2 2.天线匹配网络/ AntennaMatchingNetwork 3.Gain&Efficiency 深圳市顺达成科技有限公司 SHENDACHENGELECTRONICSCO.,LTD 3 3 4.WIFIOTA 深圳市顺达成科技有限公司 SHENDACHENGELECTRONICSCO.,LTD 4 4 可靠性测试报告 ReliabilityTestReport 测试日期 TestDate 22.5.6 样品数量 SampleQty. 3 测试人 Inspector 许燕芳 测试项目 TestItem 要求 Requirement 试验设备 testing equipment 样品1 Sample1 样品2 Sample2 样品3 Sample3 判定 PASS/NG 高温存储 在+85°C条件下暴露 24H,恢复2H后进行测 试 恒温恒湿箱OKOKOKPass 低温存储 在-40°C条件下暴露 24H,恢复2H后进行测 试 恒温恒湿箱OKOKOKPass 高温工作 在+60°C条件下通电工 作24H 恒温恒湿箱OKOKOKPass 低温工作 在-20°C条件下通电工 作24H 恒温恒湿箱OKOKOKPass 盐雾试验 (5士0.5)%氯化钠、 pH值为6.5~7.2,实验 箱温度(35±2)°C □24H☑48H 盐雾试验机OKOKOKPass 连接器铆压拉 拔力 1.13线径≥10N 0.81线径≥8N RG174≥60N RG178≥50N 推拉力计≥10N≥10N≥10NPass 最终结论 Conclusion Pass 测试人&日 期 Inspector& Date 许燕芳22.5.7 批准&日期 Approval&D ate 深圳市顺达成科技有限公司 SHENDACHENGELECTRONICSCO.,LTD 5 5 深圳市顺达成科技有限公司 SHENDACHENGELECTRONICSCO.,LTD 6 6 产品ROHS成分宣告表 安装事宜或其它 InstallWizardorOther 安装过程: 取1PCS产品,用手撕下FPC背面的离型纸,然后将FPC定位孔位置与外壳定位孔位置(定位筋 位或定位线)对齐,平整的贴附与外壳上,具体位置如下图所示: 安装过程注意事项: □粘贴天线后保证FPC完整贴附于外壳; □定位孔与外壳定位柱位置对齐; □FPC边缘与外壳边缘对齐; □带端子天线在将端子扣合到主板PCBA端时请首先对齐端子,然后垂直扣合; □拆卸天线端子时需使用工具(如专用撬棍)垂直翘起端子,不可直接拽线拆卸。 产品名 称 均匀 物质 材料 有害物质含量(PPM) HS测试报告编号HS测试报告日期 PbCdHgCrBr WF 天线 FPC NDNDNDNDND UNIB21042707HR-01 2021-4-27 NDNDNDNDND NDNDNDNDND NDNDNDNDND NDNDNDNDND 线材 NDNDNDNDND NDNDNDNDND NDNDNDNDND 端子 NDNDNDNDND
FCCTestReport ReportNo:FCS202307024W03 Issuedfor Applicant: ShenzhenGULIGULIIntelligentTechnologyCo.,Ltd. Address: 1/FBuildingC,12HuanzhenRd.,BoGangIndustrialZone, ShajingTown,Bao'anDistrict,Shenzhen,China ProductName: Hiibo BrandName: GULIGULI ModelName: GR-W25 SeriesModel: N/A FCCID: 2BB38-GR-W25 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page 2 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:ShenzhenGULIGULIIntelligentTechnologyCo.,Ltd. Address......................................: 1/FBuildingC,12HuanzhenRd.,BoGangIndustrialZone, ShajingTown,Bao'anDistrict,Shenzhen,China Manufacture'sName................:ShenzhenKimDaiIntelligenceInnovationTechnologyCo.,Ltd. Address ...................................... : Floor3,Workshop,12HuanzhenRd.,BogangCommunity, Shajing,Bao'anDistrict,Shenzhen,GuangdongProvince,China. ProductDescription ProductName ........................... :Hiibo BrandName...............................:GULIGULI ModelName..............................:GR-W25 SeriesModel..............................:N/A TestStandards..........................:FCCPart15.247 TestProcedure..........................:ANSIC63.10-2013 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetest resultsshowthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Andit isapplicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceService Laboratory,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests . :July5,2023~Jluy13,2023 DateofIssue ................................. :July13,2023 TestResult....................................:Pass Testedby: (ScottShen) Reviewedby: (DukeQian) Approvedby: (JackWang) Page 3 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY....................................................................................7 2.GENERALINFORMATION......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT.........................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS................11 2.4EQUIPMENTSLIST.........................................................................................................12 3.6DBBANDWIDTH..................................................................................................................13 3.1Limit......................................................................................................................................13 3.2TestProcedure.....................................................................................................................13 3.3Testsetup.............................................................................................................................13 3.4Testresults...........................................................................................................................14 4CONDUCTEDOUTPUTPOWER............................................................................................19 4.1limit...................................................................................................................................19 4.2testprocedure..................................................................................................................19 4.3TESTSETUP...................................................................................................................19 4.5testresults........................................................................................................................19 5.POWERSPECTRALDENSITY..............................................................................................20 5.1LIMIT................................................................................................................................20 5.2TESTPROCEDURE........................................................................................................20 5.3TESTSETUP.................................................................................................................20 5.4TESTRESULTS..............................................................................................................21 5.5originaltestdata...............................................................................................................22 6.Bandedgeandspurious(conducted).................................................................................27 6.1LIMIT................................................................................................................................27 6.2TESTPROCEDURE........................................................................................................27 6.3TESTSETUP...................................................................................................................27 6.5TESTRESULTS.......................…
Text truncated - open the document above for the full version.
Page 31 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11n20HighCH Page 32 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 6.6Spuriousemissions (802.11b)Lowestchannel 30MHz-25GHz 802.11bMiddleCH,2437MHz Page 33 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11bHighCH,2462MHz 30MHz-25GHz 802.11gLowCH,2412MHz 30MHz-25GHz Page 34 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11gMiddleCH,2437MHz 30MHz-25GHz 802.11gHighCH,2462MHz 30MHz-25GHz Page 35 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11n20LowCH,2412MHz 30MHz-25GHz 802.11n20MiddleCH,2437MHz 30MHz-25GHz Page 36 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11n20HighCH,2462MHz 30MHz-25GHz Page 37 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 7RADIATEDEMISSIONMEASUREMENT 7.1RADIATEDEMISSIONLIMITS Inany100kHzbandwidthoutsidetheoperatingfrequencyband.Incasetheemissionfallwithin theRestrictedbandspecifiedonPart15.205(a)&209(a)limitinthetableandaccordingtoANSI C63.10-2013belowhastobefollowed LIMITSOFRADIATEDEMISSIONMEASUREMENT(0.009MHz-1000MHz) Frequencies (MHz) FieldStrength (micorvolts/meter) MeasurementDistance (meters) 0.009~0.4902400/F(KHz)300 0.490~1.70524000/F(KHz)30 1.705~30.03030 30~881003 88~2161503 216~9602003 Above9605003 LIMITSOFRADIATEDEMISSIONMEASUREMENT(1GHz-25GHz) FREQUENCY(MHz) (dBuV/m)(at3M) PEAKAVERAGE Above10007454 Notes: (1)ThelimitforradiatedtestwasperformedaccordingtoFCCPART15C. (2)Thetighterlimitappliesatthebandedges. (3)Emissionlevel(dBuV/m)=20logEmissionlevel(uV/m). ForRadiatedEmission SpectrumParameterSetting AttenuationAuto DetectorPeak/AV StartFrequency1000MHz(Peak/AV) StopFrequency10thcarrierhamonic(Peak/AV) RB/VB(emissioninrestricted band) PK=1MHz/1MHz,AV=1MHz/10Hz ForBandedge SpectrumParameterSetting DetectorPeak/AV Start/StopFrequency LowerBandEdge:2300to2403MHz UpperBandEdge:2479to2500MHz RB/VB(emissioninrestrictedband)PK=1MHz/1MHz,AV=1MHz/10Hz Page 38 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com ReceiverParameterSetting AttenuationAuto Start~StopFrequency9kHz~90kHz/RB200HzforPK&AV Start~StopFrequency90kHz~110kHz/RB200HzforQP Start~StopFrequency110kHz~490kHz/RB200HzforPK&AV Start~StopFrequency490kHz~30MHz/RB9kHzforQP Start~StopFrequency30MHz~1000MHz/RB120kHzforQP 7.2TESTPROCEDURE a.Themeasuringdistanceofat3mshallbeusedformeasurementsatfrequency0.009MHzup to1GHz,andabove1GHz. b.TheEUTwasplacedonthetopofarotatingtable0.1meters(above1GHzis1.5m)abovethe groundata3meteranechoicchambertestsite.Thetablewasrotated360degreesto determinethepositionofthehighestradiation. c.Theheightoftheequipmentshallbe0.1m(above1GHzis1.5m);theheightofthetest antennashallvarybetween1mto4m.horizontalandverticalpolarizationsoftheantennaare settomakethemeasurement. d.Theinitialstepincollectingconductedemissiondataisaspectrumanalyzerpeakdetector modepre-scanningthemeasurementfrequencyrange.Significantpeaksarethenmarkedand thenQuasiPeakdetectormodere-measured. e.IfthePeakModemeasuredvaluecompliancewithandlowerthanQuasiPeakModeLimit,the EUTshallbedeemedtomeetQPLimitsandthennoadditionalQPModemeasurement performed. f.Fortheactualtestconfiguration,pleaserefertotherelatedItem–EUTTestPhotos. Note: Bothhorizontalandverticalantennapolaritiesweretested andperformedpretesttothreeorthogonalaxis.Theworstcaseemissionswerereported Page 39 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 7.3TESTSETUP (A)RadiatedEmissionTest-UpFrequencyBelow30MHz (B)RadiatedEmissionTest-UpFrequency30MHz~1GHz Page 40 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com (C)RadiatedEmissionTest-UpFrequencyAbove1GHz Page 41 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 7.4.TESTRESULTS (9KHz-30MHz) Temperature:22.7°CRelativeHumidity:61% TestVoltage:AC110VTestMode:802.11b Freq.ReadingLimitMarginState TestResult (MHz)(dBuV/m)(dBuV/m)(dB)P/F ----------PASS ----------PASS Note: Theamplitudeofspuriousemissionswhichareattenuatedbymorethan20dBbelowthe permissiblevaluehasnoneedtobereported. Distanceextrapolationfactor=40log(specificdistance/testdistance)(dB); Limitline=specificlimits(dBuv)+distanceextrapolationfactor. Page 42 of54ReportNo.:FCS202307024W03 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:7…
Text truncated - open the document above for the full version.
Page 1 of2ReportNo.:FCS202307024 Blow1GHzforradiatedemissiontestsetup Above1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202307024 Conductedemissiontestsetup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 12.76 mW |