FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Jiangsu Ever-tie Lighting Inc/
  3. 2BB69-HTWT001

2BB69-HTWT001BLE module

Jiangsu Ever-tie Lighting Inc
BLE module - FCC ID 2BB69-HTWT001 - Jiangsu Ever-tie Lighting Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 19, 2023
Application Purpose
Original Equipment
Date of Application
Sep 19, 2023
Equipment Note
BLE module
Frequency Range
2402.00000000 - 2480.00000000
Company
Jiangsu Ever-tie Lighting Inc
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Instruction-PLCxxxDyyyyyB-zzzz 1 、 TheexposedpartsatbothendsofthePCBoftheDrivershouldbestuck intothemetalslotofthelamptothemaximumdepth. 2 、 MakesurethatthebottomconductivepartofthePCBisingoodcontact withthemountingslot. 3 、 Theantennamustbeinstalledinplaceandsecuredwithplasticparts Note: ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClass Adigitaldevice,pursuanttopart15oftheFCCRules.Theselimitsare designedtoprovidereasonableprotectionagainstharmfulinterferencewhen theequipmentisoperatedinacommercialenvironment.Thisequipment generates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalled andusedinaccordancewiththeinstructionmanual,maycauseharmful interferencetoradiocommunications.Operationofthisequipmentina residentialareaislikelytocauseharmfulinterferenceinwhichcasetheuser willberequiredtocorrecttheinterferenceathisownexpense. Instruction-MACxxxDyyyyyB-zzzz 1 、 FastenthedrivetotheluminairehousingusingM4screws 2 、 Theantennamustbeinstalledinplaceandsecuredwithplasticparts Note: ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClass Adigitaldevice,pursuanttopart15oftheFCCRules.Theselimitsare designedtoprovidereasonableprotectionagainstharmfulinterferencewhen theequipmentisoperatedinacommercialenvironment.Thisequipment generates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalled andusedinaccordancewiththeinstructionmanual,maycauseharmful interferencetoradiocommunications.Operationofthisequipmentina residentialareaislikelytocauseharmfulinterferenceinwhichcasetheuser willberequiredtocorrecttheinterferenceathisownexpense. Instruction-Externalbluetooth 1 、 UseM3screwstofixthemoduletothelampshell 2 、 Wiringaccordingtospecifications 3 、 Theantennamustbeinstalledinplaceandsecuredwithplasticparts FCC Statement: Thi s device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Thi s equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures: -Reor ient the receiving antenna. -Incr ease the separation between the equipment and receiver. -Con nect the equipment into and outlet on a circuit different from that to which the receiver is connected. -Consul t the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. The distance between user and products should be no less than 20cm

Attestation Statements

Jiangsu Ever-tie Lighting Inc (date)2023/9/14 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCCID:2BB69-HTWT001) [Jiangsu Ever-tie Lighting Inc ] (“the applicant”) certifies that the equipment for n which authorization is sought is not “covered” equipment prohibited from receiving a equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name):soya song Jiangsu Ever-tie Lighting Inc (date)2023/9/13 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCCID:2BB69-HTWT001) [Jiangsu Ever-tie Lighting Inc]( “the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name):soya song

Attestation Statements

AttestationStatements (2023/9/13) TO:FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046,USA RE:AttestationStatementsPart2.911(d)(7)requestfor(GC:2BB69-HTWT001) (JiangsuEver-tieLightingInc),theundersigned,herebyauthorizeLuckyCowboyGlobal Services,LLC toactasourdesignatedU.S.agentforserviceofprocess,(JiangsuEver- tieLightingInc)acceptstomaintainanagentfornolessthanoneyearafterthegrantee hasterminatedallmarketingandimportationortheconclusionofanyCommission- relatedproceedinginvolvingtheequipment. LuckyCowboyGlobalServices,LLCacceptstheresponsibilitytoactasdesignatedU.S. agentforserviceofprocess. ApplicantInformation: CompanyName:JiangsuEver-tieLightingInc ContactName:soyasong Address:No18,EastFuxingRd,NETDANantong,Jiangsu226015China FRN:0034034009 TelephoneNo:+8618762752727 Email:[email protected] Signature [soyasong] U.S.AgentInformation: CompanyName: LuckyCowboyGlobalServices,LLC Address: 2213S.BraeswoodBlvd.#12EHouston,TX77030USA FRN: 0033510934 ContactName:LouieLiu TelephoneNo:+1(713)992-3369 Email:[email protected] Signature [LouieLiu]

Cover Letter(s)

FederalCommunicationsCommission Authorization&EvaluationDivision 7345OaklandMillsRoad Columbia,Maryland2104 DATE:2023/9/13 6 AuthoritytoActasAgent Onourbehalf,IappointBlueAsiaofTechnicalServices(Shenzhen)Co.,LtdAnd BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen, GuangdongProvince,China(NameofAgentcompanynameandaddress)toactasour agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on ourbehalf, I acknowledge that all responsibility for complying with the terms and conditionsfor certification, still resides withJiangsu Ever-tie Lighting Inc AndNo 18, East Fuxing Rd, NETDA Nantong, Jiangsu 226015 China (Applicant Name and address) <Signature> Namesoya song Title/ Company Jiangsu Ever-tie Lighting Inc

Cover Letter(s)

Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: DATE2023/9/13 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: _2BB69-HTWT001__ Product Name:BLE module (List here the documents for which you are seeking confidentiality – for example ...) <Signature> Name:soya song Title :R&D manager Company:  Schematics  Block diagram Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The pu blic disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Jiangsu Ever-tie Lighting Inc

Cover Letter(s)

BLE module

External Photos

ModelNo.: ADP)SIF50-I1250/120-347/T/D1/APP(WT)

ID Label/Location Info

Product Name:BLE module

Internal Photos

ModelNo.: ADP)SIF50-I1250/120-347/T/D1/APP(WT)

RF Exposure Info

RF Exposureevaluation FCCID : 2BB69-HTWT001 Accordingto 447498D04InterimGeneralRF ExposureGuidancev01 Ant gain = 3.27 dBi Max Output power =-0.364dBm @ 2480MHz ERP = -0.364dBm+3.27dBi-2.15=0.756dBm So ERP is worse case 10^0.0756=1.190 mW < 2.715 mW Comply with RF exposure exemption limit.

Test Report

Page 1 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] TESTREPORT ProductName: BLEmodule BrandMark: N/A ModelNo.: (ADP)SIF50-I1250/120-347/T/D1/APP(WT) ExtensionModel: (ADP)SIF30-I0750/120-347/T/D1/APP(WT), (ADP)SIF50-I1250/120-347/T/D1/F/APP(WT), (ADP)SIF30-I0750/120-347/T/D1/F/APP(WT), (ADP)SIF50-I1250/120-277/T/D1/APP(WT), (ADP)SIF30-I0750/120-277/T/D1/APP(WT), (ADP)SIF50-I1250/120-277/T/D1/F/APP(WT), (ADP)SIF30-I0750/120-277/T/D1/F/APP(WT) FCCID: 2BB69-HTWT001 ReportNumber: BLA-EMC-202307-A7302 DateofSample Receipt : 2023/7/25 DateofTest: 2023/8/3to2023/8/20 DateofIssue: 2023/8/22 TestStandard: 47CFRPart15,SubpartC15.247 TestResult:Pass Preparedfor: JiangsuEver-tieLightingInc No18,EastFuxingRd,NETDANantong,Jiangsu226015China Preparedby: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China TEL:+86-755-23059481 Compiledby:Reviewby: Approvedby:Date:2023/8/22 ReportNo.:BLA-EMC-202307-A7302 Page 2 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] REPORTREVISERECORD VersionNo.DateDescription 002023/8/22Original ReportNo.:BLA-EMC-202307-A7302 Page 3 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] TABLEOFCONTENTS 1TESTSUMMARY..............................................................................................................................................5 2GENERALINFORMATION...............................................................................................................................6 3GENERALDESCRIPTIONOFE.U.T................................................................................................................6 4TESTENVIRONMENT......................................................................................................................................7 5TESTMODE......................................................................................................................................................7 6MEASUREMENTUNCERTAINTY....................................................................................................................7 7DESCRIPTIONOFSUPPORTUNIT................................................................................................................8 8LABORATORYLOCATION..............................................................................................................................9 9TESTINSTRUMENTSLIST............................................................................................................................10 10CONDUCTEDEMISSIONSATACPOWERLINE(150KHZ-30MHZ).........................................................12 10.1LIMITS......................................................................................................................................................................12 10.2BLOCKDIAGRAMOFTESTSETUP............................................................................................................................12 10.3PROCEDURE.............................................................................................................................................................12 10.4TESTDATA..................................................................................................................................................................14 11CONDUCTEDBANDEDGESMEASUREMENT.........................................................................................16 11.1LIMITS......................................................................................................................................................................16 11.2BLOCKDIAGRAMOFTESTSETUP............................................................................................................................16 11.3TESTDATA..................................................................................................................................................................17 12RADIATEDSPURIOUSEMISSIONS...........................................................................................................18 12.1LIMITS......................................................................................................................................................................18 12.2BLOCKDIAGRAMOFTESTSETUP............................................................................................................................19 12.3PROCEDURE.............................................................................................................................................................19 12.4TESTDATA..................................................................................................................................................................21 13ANTENNAREQUIREMENT..........................................................................................................................29 13.1CONCLUSION...............................................................................................................................................................29 14RADIATEDEMISSIONSWHICHFALLINTHERESTRICTEDBANDS.....................................................30 14.1LIMITS......................................................................................................................................................................30 14.2BLOCKDIAGRAMOFTESTSETUP............................................................................................................................31 14.3PROCEDURE...................................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 地址:深圳市南山区高新中一道8号万和医药园1楼 1/12 規格承認書 SPECIFICATIONFORAPPROVAL 客户 CUSTOMER:安特源 客户料号 CUSTOMERNO:IPEX-FPC-P4N-370 品名 PARTNAME:2.4GHz天线:FPC白色,1代端子焊接1.13白线L=370mm 供方料号 SUPPLIERNO:YL1523-2.4GHz-V1(IPEX-P4N-370) 日期Date:2023.04.18 客户确认CUSTOMERAPPROVEDBY APPROVALCHIEFSUPERVISOR 供方确认SUPPLIERSIGNATURE APPROVALCHECKDESIGN 赵旋旋陈娜张权 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 2 / 12 实验室测试环境及设备 测试项目(TestProject): S11、S12、VSWR、Efficiency、Gain3DRadiationPattern、TRP、 TIS 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 3 / 12 規格承認書 ....................................................................................................................................................3 1. 技术指标( TechnicalIndex ) ....................................................................................................................4 2. 图纸( Drawings ) ......................................................................................................................................5 3. 天线测试数据( Antennatestdata ) ....................................................................................................6-11 4. 包装( package ) ........................................................................................................................................12 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 4 / 12 1.技术指标(TechnicalIndex) 频率范围FrequencyRange(MHz)2400-2500MHz 增益 Gain ( dBi ) MAX3.27dBi 驻波比VSWR/500hms≤2.0 输入阻抗 Impedance50 Ω 接头Termination1代端子1.13白线L=370mm 工作温度(°C)-30~+65 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 5 / 12 2. 图纸( Drawings ) 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 6 / 12 3. 天线测试数据( Antennatestdata ) SWR测试结果 频率(MHz)VSWR 2400Mhz1.47 2450Mhz1.21 2500Mhz1.11 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 7 / 12 回损测试结果 频率(MHz)Returnloss 2400Mhz-16.70 2450Mhz-21.10 2500Mhz-14.07 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 8 / 12 3-1 天线无源效率 / 增益 PassiveTestFor2.4G FreqEffiGain (MHz)(%)(dBi) 240066.83.27 240564.122.84 241063.392.88 241562.612.66 242064.012.63 242562.312.47 243060.232.34 243563.622.55 244066.282.73 244566.342.75 245067.982.87 245568.172.91 246068.552.98 246567.292.95 247065.452.87 247565.622.92 248065.522.94 248566.242.98 249066.732.98 249564.942.85 250064.212.79 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 9 / 12 3-2 天线苹果图 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 10 / 12 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 11 / 12 地址:深圳市南山区高新中一道8号万和医药园1楼 深圳有力科技有限公司 ShenZhenPowerfulTechnologyCO.,Limited 12 / 12 天线组件包装说明 一般要求: 1.说明客户名,项目名称,型号。 2.图片说明内外箱,出货时包装方式,层数,单层数量等。 3.备注栏内填写包装所用材料名称,数量等。 产品料号: YL1523-2.4GHz-V1 IPEX-P4N-370 产品名称:2.4GHz天线 产品版本:V1 包装方式:PE袋+外箱 图1:一扎端子头用泡棉 包扎后装入PE袋,每袋 200/PCS 图 2 :装箱PE袋周围泡棉包住保护 单扎数量100pcs/扎 单PE袋数量200PCS/袋 单箱数量2000PCS/箱 图3:外包装箱外形图4:贴标签,整箱出货

Test Report

ReportNo.:BLA-EMC-202307-A7302 Page 45 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] PowerNVNTBLE2M2442MHzAnt1 PowerNVNTBLE2M2480MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 46 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202307-A7302 Page 47 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.2-6DBBANDWIDTH ConditionModeFrequency (MHz) Antenna-6dBBandwidth (MHz) Limit-6dB Bandwidth(MHz) Verdict NVNTBLE1M2402Ant10.6660.5Pass NVNTBLE1M2442Ant10.710.5Pass NVNTBLE1M2480Ant10.6740.5Pass NVNTBLE2M2402Ant11.320.5Pass NVNTBLE2M2442Ant11.30.5Pass NVNTBLE2M2480Ant11.3050.5Pass -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 48 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] -6dBBandwidthNVNTBLE1M2480MHzAnt1 -6dBBandwidthNVNTBLE2M2402MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 49 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] -6dBBandwidthNVNTBLE2M2442MHzAnt1 -6dBBandwidthNVNTBLE2M2480MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 50 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202307-A7302 Page 51 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.3OCCUPIEDCHANNELBANDWIDTH ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.02926 NVNTBLE1M2442Ant11.03113 NVNTBLE1M2480Ant11.01946 NVNTBLE2M2402Ant12.01576 NVNTBLE2M2442Ant12.02969 NVNTBLE2M2480Ant12.01938 OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 52 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] OBWNVNTBLE1M2480MHzAnt1 OBWNVNTBLE2M2402MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 53 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] OBWNVNTBLE2M2442MHzAnt1 OBWNVNTBLE2M2480MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 54 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202307-A7302 Page 55 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.4MAXIMUMPOWERSPECTRALDENSITYLEVEL ConditionModeFrequency(MHz)AntennaMaxPSD(dBm)Limit(dBm)Verdict NVNTBLE1M2402Ant1-11.2048Pass NVNTBLE1M2442Ant1-9.3678Pass NVNTBLE1M2480Ant1-9.888Pass NVNTBLE2M2402Ant1-13.3978Pass NVNTBLE2M2442Ant1-13.0888Pass NVNTBLE2M2480Ant1-13.2388Pass PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 56 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] PSDNVNTBLE1M2480MHzAnt1 PSDNVNTBLE2M2402MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 57 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] PSDNVNTBLE2M2442MHzAnt1 PSDNVNTBLE2M2480MHzAnt1 ReportNo.:BLA-EMC-202307-A7302 Page 58 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202307-A7302 Page 59 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.5BANDEDGE ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-52.33-30Pass NVNTBLE1M2480Ant1-53.45-30Pass NVNTBLE2M2402Ant1-47.92-30Pass NVNTBLE2M2480Ant1-53.13-30Pass BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:BLA-EMC-202307-A7302 Page 60 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:BLA-EMC-202307-A7302 Page 61 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] BandEdgeNVNTBLE2M2402MHzAnt1Ref BandEdgeNVNTBLE2M2402MHzAnt1Emission ReportNo.:BLA-EMC-202307-A7302 Page 62 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] BandEdgeNVNTBLE2M2480MHzAnt1Ref BandEdgeNVNTBLE2M2480MHzAnt1Emission ReportNo.:BLA-EMC-202307-A7302 Page 63 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202307-A7302 Page 64 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.6CONDUCTEDRFSPURIOUSEMISSION ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-43.7-30Pass NVNTBLE1M2442Ant1-43.24-30Pass NVNTBLE1M2480Ant1-43.29-30Pass NVNTBLE2M2402Ant1-42.38-30Pass NVNTBLE2M2442Ant1-42.29-30Pass NVNTBLE2M2480Ant1-42.86-30Pass Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:BLA-EMC-202307-A7302 Page 65 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] Tx.SpuriousNVNTBLE1M2442MHzAnt1Ref Tx.SpuriousNVNTBLE1M2442MHzAnt1Emission ReportNo.:BLA-EMC-202307-A7302 Page 66 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ReportNo.:BLA-EMC-202307-A7302 Page 67 of 74 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] Tx.SpuriousNVNTBLE2M2402MHzAnt1Ref Tx.SpuriousNVNTBLE2M2402MHzAnt1Emission …

Text truncated - open the document above for the full version.

Test Setup Photos

ModelNo.: ADP)SIF50-I1250/120-347/T/D1/APP(WT) ConductedEmissionsatACPowerLine(150kHz-30MHz) RadiatedSpuriousEmissions

Contact Information

Applicant

soya song
[email protected]+86 18762752727Fax: 68223333

Test Firm

BlueAsia of Technical Services (Shenzhen)Blue Zheng
[email protected]+86 755-23059481-815

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz919.60 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Jiangsu Ever-tie Lighting Inc

BLE module - FCC ID 2BB69-HTCT003 - Jiangsu Ever-tie Lighting Inc
2BB69-HTCT003

BLE module

Oct 06, 2023

Equipment Class

DTS - Digital Transmission System
BLE module - FCC ID 2BB69-HTWT002 - Jiangsu Ever-tie Lighting Inc
2BB69-HTWT002

BLE module

Sep 25, 2023

Equipment Class

DTS - Digital Transmission System