Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
,3UR ,3UR
Kezhi(HuiZhou) Electronic Technology Co., Ltd. Address: Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County, Huizhou, Guangdong China Tel: (86)0752-6396828 E-mail: [email protected] Attestation Letter Our product Mechanical keyboard, model: I75, 661, I75Pro, FCC ID:2BBA6-I75, for marketing purpose, this product only supports BT(GFSK), BLE 1M, SRD(2405-2475MHz). The other functions, bands and modes was disabled to use by manufacturer in the software, the end user has no capability to activate it. Date:2024-09-02 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam: Sincerely, Signature: Printed Name: chuangling zhang Title: Engineer
Kezhi(HuiZhou) Electronic Technology Co., Ltd. Address: Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County, Huizhou, Guangdong China Tel: (86)0752-6396828 E-mail: [email protected] CFR 47 Β§2.911(d)(5)(i)(ii) Attestation Letter Attestation Letter Date: 2024-09-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 Β§2.911(d)(5)(i)(ii) Filing FCC ID:2BBA6-I75 Kezhi(HuiZhou) Electronic Technology Co., Ltd.certifies that the equipment for which authorization is soughtis not βcoveredβ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Kezhi(HuiZhou) Electronic Technology Co., Ltd.certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing βcoveredβ equipment. Sincerely, Signature: Printed Name: chuangling zhang Title: Engineer
U.S. AGENT LETTER OF ATTESTATION Date: 2024-09-02 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 Β§2.911(d)(7) Filing FCC ID:2BBA6-I75 Kezhi(HuiZhou) Electronic Technology Co., Ltd. ( βthe Applicantβ) certifies that, as of the date of the filing of the application, Iconsigh Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Kezhi(HuiZhou) Electronic Technology Co., Ltd. (βthe Applicantβ) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant: Kezhi(HuiZhou) Electronic Technology Co., Ltd. Address: Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County, Huizhou, Guangdong China FRN: 0033804261 Tel: (86)0752-6396828 Email: [email protected] Signed by (printed name): chuangling zhang Iconsigh Inc.accepts, as of thedate of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Inc. Address: 2310HomesteadRoad,SuiteC1,LosAltos, CA,94024,USA FRN: 0033398652 Tel.: +1(408)320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Signature:
QA-FR-170-B Kezhi(HuiZhou) Electronic Technology Co., Ltd. Address: Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County, Huizhou, Guangdong China Tel: (86)0752-6396828 E-mail: [email protected] FCC Authorization Date: 2024-09-02 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We ,Kezhi(HuiZhou) Electronic Technology Co., Ltd.Hereby authorizes Bay Area Compliance Laboratories Corp.(Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratory Corp.(Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely, Signature: Printed Name: chuangling zhang Title: Engineer
QA-FR-171-A Kezhi(HuiZhou) Electronic Technology Co., Ltd. Address: Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County, Huizhou, Guangdong China Tel: (86)0752-6396828 E-mail: [email protected] FCC Confidential Authorization Date: 2024-09-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID:2BBA6-I75 In accordance with Sections 0.457 and 0.459 of the Commissionβs Rules, Kezhi(HuiZhou) Electronic Technology Co., Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below: β’ Block Diagram β’ Schematics β’Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Printed Name: chuangling zhang Title: Engineer
Kezhi(HuiZhou) Electronic Technology Co., Ltd. Add: Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County, Huizhou, Guangdong China Tel: (86)0752-6396828 Email: [email protected] DECLARATION OF SIMILARITY Date: 2024-08-20 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam: We, Kezhi(HuiZhou) Electronic Technology Co., Ltd., hereby declare that theproduct: Mechanical keyboard,FCC ID:2BBA6-I75, model:661, I75Proareelectrically identicalwiththemodel:I75whichwastestedbyBayAreaComplianceLaboratories Corp.(Dongguan). A description of the differences between thosemodels and that are declared similar are as follows: They are the same product, just the different model name, the rest are the same. Their different models are used in different salechannels, but each model contains three colors of black, white and pink. The detail information, please check the reports. Pleasecontactmeshouldtherebeneedforanyadditionalclarificationorinformation. Sincerely, Signature: Printed name: chuangling zhang Title: Engineer
Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 1 / 15 EUT EXTERNAL PHOTOS Model: I75 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 2 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 3 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 4 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 5 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 6 / 15 Model: 661 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 7 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 8 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 9 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 10 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 11 / 15 Model: I75Pro Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 12 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 13 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 14 / 15 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-EXP Page 15 / 15
ZZZN]]LFRP 3UJKR /94 ,))/* (('/ /) / / T V [ Z < 0DGHLQ&KLQD ZZZN]]LFRP 3UJKR /6XU94 ,))/* (('/ /) / / T V [ Z < 0DGHLQ&KLQD ZZZN]]LFRP 3UJKR 94 ,))/* (('/ /) / / T V [ Z < 0DGHLQ&KLQD
Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 1 / 25 EUT INTERNAL PHOTOS Model: I75 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 2 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 3 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 4 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 5 / 25 ANT Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 6 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 7 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 8 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 9 / 25 Model: 661 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 10 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 11 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 12 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 13 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 14 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 15 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 16 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 17 / 25 ANT Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 18 / 25 Model: I75Pro Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 19 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 20 / 25
Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 21 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 22 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 23 / 25 ANT Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 24 / 25 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-INP Page 25 / 25
Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402W59393E-RF-00B Report Template Version: FCC+IC-BT-V1.2 Page 53 of 54 EXHIBIT C - RF EXPOSURE EVALUATION SAR EVALUATION Applicable Standard According toΒ§15.247(i) and Β§1.1310, systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commissionβs guideline. According to KDB447498 D01 General RF Exposure Guidance v06: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances β€ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] κ [βf(GHz)] β€ 3.0 for 1-g SAR and β€ 7.5 for 10-g extremity SAR, where β’ f(GHz) is the RF channel transmit frequency in GHz β’ Power and distance are rounded to the nearest mW and mm before calculation β’ The result is rounded to one decimal place for comparison β’ 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is β€ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. Measurement Result The max conducted power including tune-up tolerance is 3.5 dBm (2.24 mW). [(max. power of channel, mW)/(min. test separation distance, mm)][βf(GHz)] =2.24/5*(β2.480) = 0.7< 3.0 Note: the max conducted power including tune-up tolerance was declared by manufacturer. The Bluetooth and SRD can`t transmit simultaneously. Result: Compliant. The stand-alone SAR evaluation is not necessary.
TEST REPORT Applicant: KeZhi (HuiZhou) Electronic Technology Co., Ltd. Address: FCC: Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County, Huizhou, Guangdong China IC: Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County Huizhou 516123 China Product Name: Mechanical keyboard FCC ID: 2BBA6-I75 IC: 31424-I75 HVIN: I75, 661, I75Pro Standard(s): 47 CFR Part 15, Subpart C(15.247) RSS-247 Issue 3, August 2023 RSS-Gen, Issue 5, February 2021 Amendment 2 ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Report Number: 2402W59393E-RF-00B Report Date: 2024/9/26 The above device has been tested and found compliant with the requirement of the relative standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Pedro Yun Approved By: Ivan Cao Title: Project Engineer Title: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked β² is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with β .This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402W59393E-RF-00B Report Template Version: FCC+IC-BT-V1.2 Page 2 of 54 CONTENTS DOCUMENT REVISION HISTORY κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 4 1. GENERAL INFORMATION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.1 GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.2 ACCESSORY INFORMATION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.3 ANTENNA INFORMATION DETAILβ² κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.4 EQUIPMENT MODIFICATIONS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 2. SUMMARY OF TEST RESULTS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 6 3. DESCRIPTION OF TEST CONFIGURATION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.1 OPERATION FREQUENCY DETAIL κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.2 EUT OPERATION CONDITION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.3 SUPPORT EQUIPMENT LIST AND DETAILS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.4 SUPPORT CABLE LIST AND DETAILS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3.5 BLOCK DIAGRAM OF TEST SETUP κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 3.6 TEST FACILITY κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 3.7 MEASUREMENT UNCERTAINTY κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 4. REQUIREMENTS AND TEST PROCEDURES κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 4.1 AC LINE CONDUCTED EMISSIONS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 4.1.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 4.1.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 12 4.1.3 EMI Test Receiver Setup κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 12 4.1.4 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 13 4.1.5 Corrected Amplitude & Margin Calculation κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 13 4.1.6 Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 13 4.2 RADIATED SPURIOUS EMISSIONS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 14 4.2.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 14 4.2.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 14 4.2.3 EMI Test Receiver & Spectrum Analyzer Setup κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.2.4 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.2.5 Corrected Result & Margin Calculation κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.2.6 Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.3 20 DB EMISSION BANDWIDTH κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 4.3.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 4.3.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 4.3.3 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 18 4.3.4 Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 18 4.4 99% OCCUPIED BANDWIDTH: κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκβ¦
Text truncated - open the document above for the full version.
Antenna Specification Specifications Summary ITEMSPEC. Model NameIBM 2.4 GHz Center Frequency 2402 MHz 2441 MHz 2480 MHz 2.34 dBi 2.07dBi 1.45 dBi MAX. GAIN2.34 dBi PolarizationHorizontal Azimuth Beam Pattern Omni-directional Impedance50β¦ Antenna Photo & Length (mm) Dingnan JinPeng Electronics Co.,Ltd. Jinpeng Industrial Park, Futian Industrial Community, Lishi Town, Dingnan County, Ganzhou City, Jiangxi Province Manufacturer Address 1. Main antenna : 2402 MHz 1.1 Horizontal Frequency(MHZ):2402Antenna Polarity:Horizontal Maximum Gain(dBi): 2.34 Average Gain(dBi):-2.48 Minim um Gain(dBi):-55.18 1.2 Vertical Frequency(MHZ):2402Antenna Polarity:Vertical Maximum Gain(dBi): -4.51 AverageGain(dBi) :-8.98 Minimum Gain(dBi):-62.3 2. Main antenna : 2441 MHz 2.1 Horizontal Frequency(MHZ):2441Antenna Polarity:Horizontal Maximum Gain(dBi): 2.07 Average Gain(dBi) : -2.54 Minimum Gain(dBi): -66.98 2.2 Vertical Frequency(MHZ):2441Antenna Polarity:Vertical Maximum Gain(dBi): -4.29 AverageGain(dBi) :-8.81 Minimum Gain(dBi):-51.4 2. Main antenna : 2480 MHz 2.1 Horizontal Frequency(MHZ): 2480AntennaPolarity:Horizontal Maximum Gain(dBi):1.45 AverageG ain(dBi) : -3.34 Minimum Gain(dBi): -53.4 2.2 Vertical Frequency(MHZ):2480Antenna Polarity:Vertical Maximum Gain(dBi): -4.95 AverageGain(dBi) :-9.06 Minimum Gain(dBi):-60.00
Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-00B-TSP TEST SETUP PHOTOGRAPHS Radiated Emission 9k-30MHz Parallel View Radiated Emission 9k-30MHz Perpendicular View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-00B-TSP Radiated Emission 9k-30MHz Ground-parallel View Radiated Emission 30M-1GHz View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-00B-TSP Radiated Emission 1-18GHz View Radiated Emission 1-18GHz View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402W59393E-RF-00B-TSP Radiated Emission 18-25GHz View
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.00 mW |

Mechanical keyboard
Equipment Class
DTS - Digital Transmission SystemMechanical keyboard
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Mechanical keyboard
Equipment Class
DTS - Digital Transmission System