
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User Manual Wireless Charger- WPC026 This wireless charger can charge your Qi-enabled smartphone. Just simply place your smartphone on the rubber mat above the wireless charger. The wireless charger supports up to 15W power delivery. NOTE: The wireless charger may not work if your phone case is metal. Take the phone out of the case and place the phone on the charger. After the user starts the vehicle, the power supply of the product will be connected, wait for the charging indicator of the product to be charged to light up, indicating that the product works successfully. EU Declaration of Conformity Hereby, Xuancheng Luxshare Precision Industrial Co., Ltd. declares that the radio equipment Wireless Charger Inductive Charger, is in compliance with Directive 2014/53/EU. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. Radiation Exposure Statement: This equipment complies with radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Frequency band in which the radio equipment operates: 127.772kHz Maximum power transmitted: < 0.15mW Model name: WCBS Manufacturer: Xuancheng Luxshare Precision Industrial Co., Ltd. Model Number: WCBS Max. Output: 15W Input: 13.5 V DC @ 2.5A Operating Temperature: -40°C~+85°C Storage Temperature: -40°C~+85°C FCC statement: Please note that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. RF exposure statement This equipment complies with radio frequency exposure limits set forth by the FCC for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the device and the user or bystanders. This device must not be co-located or operating in conjunction with any other antenna or transmitter. ICES statement: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1)L’appareil ne doit pas produire de brouillage; (2)L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This equipment complies with radio frequency exposure limits set forth by the Innovation, Science and Economic Development Canada for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the device and the user or bystanders. This device must not be co-located or operating in conjunction with any other antenna or transmitter. Cet équipement est conforme aux limites d'exposition aux radiofréquences définies par la Innovation, Sciences et Développement économique Canada pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre le dispositif et l'utilisateur ou des tiers. Ce dispositif ne doit pas être utilisé à proximité d’une autre antenne ou d’un autre émetteur. Supplier’s Declaration of Conformity 47 CFR § 2.1077 Compliance Information Unique Identifier: (Trade Name:WCBS, Model Number:WCBS) Responsible Party – U.S. Contact Information ABC Corporation Steed Address City, State Zip Code Telephone number or internet contact information FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 1 of 3 Type Designation: WCBS FCC ID: 2BBAQ-WCBS Page 2 of 3 Type Designation: WCBS FCC ID: 2BBAQ-WCBS Page 3 of 3 Type Designation: WCBS FCC ID: 2BBAQ-WCBS
Page 1 of 2 Type Designation: WCBS FCC ID: 2BBAQ-WCBS Page 2 of 2 Type Designation: WCBS FCC ID: 2BBAQ-WCBS
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN23YC1T 003 Auftrags-Nr.: Order no.: 168426238 Seite 1 von 11 Page 1 of 11 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2023-05-10 Auftraggeber: Client: Xuancheng Luxshare Precision Industry Co., Ltd. No.5, Baishou Road, Hi - Tech Industrial Development Zone, Xuancheng, Anhui Province, China Prüfgegenstand: Test item: WCBS Bezeichnung / Typ-Nr.: Identification / Type no.: WCBS Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR47 FCC Part 2.1091 Wareneingangsdatum: Date of sample receipt: 2023-05-15 Prüfmuster-Nr.: Test sample no: A003471729-004 Prüfzeitraum: Testing period: 2023-06-12 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass Please refer to Photo Document geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2023-06-20 Ausstellungsdatum: Issue date: 2023-06-20 Stellung / Position: Sachverständige(r)/ExpertStellung / Position:Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BBAQ-WCBS Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende:P(ass) = entspricht o.g. Prüfgrundlage(n)F(ail) = entspricht nicht o.g. Prüfgrundlage(n)N/A = nicht anwendbarN/T = nicht getestet * Legend:P(ass) = passed a.m. test specification(s)F(ail) = failed a.m. test specification(s)N/A = not applicableN/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 17-18F, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P. R. China Mail: [email protected] · Web: www.tuv.com Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN23YC1T 003 Test report no.: Seite 2 von 11 Page 2 of 11 Anmerkungen Remarks 1Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurement results, in this test report is based on the “Zero Guard Band Rule” and “Simple Acceptance” in accordance with ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified in the applied standard mentioned on Page 1 of this report or requested by the customer. This means that measurement uncertainty is not taken in account and hence als…
Text truncated - open the document above for the full version.
Antenna Type: Coil, Gain:0dBi Xuancheng Luxshare Precision Industry Co., Ltd. No.5, Baishou Road, Hi - Tech Industrial Development Zone, Xuancheng, Anhui Province, China
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN23YC1T 001 Auftrags-Nr.: Order no.: 168426238 Seite 1 von 15 Page 1 of 15 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2023-05-10 Auftraggeber: Client: Xuancheng Luxshare Precision Industry Co., Ltd. No.5, Baishou Road, Hi - Tech Industrial Development Zone, Xuancheng, Anhui Province, China Prüfgegenstand: Test item: WCBS Bezeichnung / Typ-Nr.: Identification / Type no.: WCBS Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR47 FCC Part 15: Subpart C Section 15.209 CFR47 FCC Part 15: Subpart C Section 15.215 Wareneingangsdatum: Date of sample receipt: 2023-05-15 Prüfmuster-Nr.: Test sample no: A003471729-004 Prüfzeitraum: Testing period: 2023-05-17 - 2023-05-18 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass Please refer to Photo Document geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2023-06-12 Ausstellungsdatum: Issue date: 2023-06-12 Stellung / Position: Sachverständige(r)/ExpertStellung / Position:Sachverständige(r)/Expert Sonstiges / Other: : FCC ID: 2BBAQ-WCBS Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende:P(ass) = entspricht o.g. Prüfgrundlage(n)F(ail) = entspricht nicht o.g. Prüfgrundlage(n)N/A = nicht anwendbarN/T = nicht getestet * Legend:P(ass) = passed a.m. test specification(s)F(ail) = failed a.m. test specification(s)N/A = not applicableN/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 17-18F, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P. R. China Mail: [email protected] · Web: www.tuv.com Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN23YC1T 001 Test report no.: Seite 2 von 15 Page 2 of 15 Anmerkungen Remarks 1Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurement results, in this test report is based on the “Zero Guard Band Rule” and “Simple Acceptance” in accordance with ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified in the applied standard mentioned on Page 1 of this report or requested by the custom…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix B CN23YC1T 001 Page 1 of 2 Appendix B: Photographs of the Test Set-Up APPENDIX B: PHOTOGRAPHS OF THE TEST SET-UP.......................................................................................................1 PHOTOGRAPH 1: SET-UP PHOTO FOR RADIATED SPURIOUS EMISSION, BELOW 30MHZ.......................................................................2 PHOTOGRAPH 2: SET-UP PHOTO FOR RADIATED SPURIOUS EMISSION, 30MHZ - 1GHZ......................................................................2 Prüfbericht - Produkte Test Report - Products Appendix B CN23YC1T 001 Page 2 of 2 Photograph 1: Set-up photo for Radiated Spurious Emission, Below 30MHz Photograph 2: Set-up photo for Radiated Spurious Emission, 30MHz - 1GHz ----------------------------------End of report----------------------------
No.5, Baishou Road, Hi - Tech Industrial · Xuancheng · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.127772 MHz - 0.127772 MHz | - |