Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
* the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. SC6037192 U.S. Agent Designation for Service of Process - Certification Attestation Letter 3/18/2026 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2BBDT-SR1KW8L FRN of applicant: 0033818063 Per section 2.911(d)(7) of the FCC rules, CE LINK LIMITED FRN:0033818063(“the applicant”) certifies that the equipment for which authorization is sought is designated to thefollowing U.S. agent* for service of process: Company Name: Global Product Services and Consultation LLC FCC Registration Number (FRN): 0033406703 Physical U.S. Company Address: 328 W Palm Ave. Monrovia, CA91016 Contact Person: Michael Chan Tel: +1 626 366 4358 Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related Applicant Signed:Agent Signed (if different from Applicant): Signed: Printed name: Vic Wang Title: Engineer Company Name: CE LINK LIMITED Date: 3/18/2026 Signed: Printed name: Michael Chan Title: Technical Director Company Name: Global Product Services and Consultation LLC Date: 3/25/2026
CE LINK LIMITED 2026-03-18 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BBDT-SR1KW8L) [CE LINK LIMITED] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Vic Wang Engineer CE LINK LIMITED ROOM 2204 22/F TUNG CHIU COMMERCIAL CENTRE 193 LOCKHART ROAD WANCHAI HONG KONG SAR CHINA CE LINK LIMITED 2026-03-18 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BBDT-SR1KW8L) [CE LINK LIMITED] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Vic Wang Engineer CE LINK LIMITED ROOM 2204 22/F TUNG CHIU COMMERCIAL CENTRE 193 LOCKHART ROAD WANCHAI HONG KONG SAR CHINA
Declaration on model difference We the undersigned hereby confirm that these models are identical, and all models have the same RF module and antenna, PCB layout, schematics and component. The differences lie in the model and the trademark. Please see the detailed information as following. Product name FCC ID Model no. Portable Power Station 2BBDT-SR1KW8L SR1KW8L-SG2-US, PS1800 Pro W-US, M1000, ENPP01800USBL-P, TA-PN1K8QI-US- BK1, TA-PN1K8QI-US-BG1 Model No.: Trade mark SR1KW8L-SG2-US CE-LINK PS1800 Pro W-US HINEN ENPP01800USBL-P Energizer TA-PN1K8QI-US-BK1, TA-PN1K8QI-US- BG1 teleadapt M1000 Aviva Sincerely, Vic Wang Engineer CE LINK LIMITED ROOM 2204 22/F TUNG CHIU COMMERCIAL CENTRE 193 LOCKHART ROAD WANCHAI HONG KONG SAR CHINA
CE LINK LIMITED 2026-03-18 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Guangdong Global Testing Technology Co., Ltd. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Vic Wang Engineer CE LINK LIMITED ROOM 2204 22/F TUNG CHIU COMMERCIAL CENTRE 193 LOCKHART ROAD WANCHAI HONG KONG SAR CHINA
CE LINK LIMITED 2026-03-18 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (EUT Name: Portable Power Station /Model: SR1KW8L-SG2-US, PS1800 Pro W-US, M1000, ENPP01800USBL-P, TA-PN1K8QI- US-BK1, TA-PN1K8QI-US-BG1 /FCC ID: 2BBDT-SR1KW8L) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Block Diagram, Operational Description, Schematics) required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Vic Wang Engineer CE LINK LIMITED ROOM 2204 22/F TUNG CHIU COMMERCIAL CENTRE 193 LOCKHART ROAD WANCHAI HONG KONG SAR CHINA
External
223.90 215.00 223.90 新����W美规 蓝色印字:镭雕 350.00 260.00 ��.�*�.�mm 水平居中于接口 �.�*�.�mm 水平居中于接口 �.�*�.�mm 水平居中于接口 �.�*�.�mm 水平居中于接口 �.�*�.�mm 水平居中于接口 �.�*�.�mm 水平居中于接口 ��.�*�.�mm 水平居中于接口 ��.�*�.�mm 水平居中于接口 ��.�*�.�mm ��*�.�mm 水平居中于接口 ��.�*�.�mm 水平居中于接口 �.�*�.�mm 水平居中于接口 LED LIGHT USB-C4 140W USB-C3 140W POWER 12.6V 30A DC12.6V DC OUTPUT USB-C2 30W USB-C1 30W USB-A2 12W USB-A1 12W WARNING / AVERTISSEMENT Do not overcharge the internal battery. See Instruction Manual. / Ne pas surcharger la batterie interne. Consulter le manuel d’ utilisation. Do not smoke, strike a match, or cause a spark in the vicinity of the power pack. / Il ne faut pas fumer, allumer une allumette ou produire des étincelles à proximité du bloc d’ alimentation. Only charge the internal battery in a well ventilated area. / Charger la batterie uniquement dans un endroit bien aéré. CAUTION: Risk of Electric Shock. Connect only to properly grounded outlets. / MISE EN GARDE: Risque de décharge électrique. Brancher l’ unité uniquement à des prises de courant correctement mises à la masse. CAUTION: Risk of Injury To Persons. Do not use this product if the power cord or the battery cables are damaged in any way. / MISE EN GARDE: Risque de blessure aux personnes. Ne pas utiliser ce produit si le cordon d’ alimentation ou les câbles de batterie sont endommagés de quelque façon. CAUTION: Risk of Electric Shock. Do not remove cover. No user serviceable parts inside. Refer servic- ing to qualified service personnel. / MISE EN GARDE: Risque de décharge électrique. Ne pas enlever le couvercle. Aucune des pièces à l'intérieur ne peut être réparée par l'utilisateur. L'entretien courant doit être effectué par un personnel d'entretien qualifié. CAUTION: This device is not intended for use in a commercial repair facility. / MISE EN GARDE: Le dispositif n’ est pas destiné à être utilisé dans un atelier de réparation commercial. CAUTION: This equipment is not waterproof, do not use in wet or damp environment. Always store indoors, avoid direct sunlight/ Cet équipement n’ est pas étanche, n’ employez pas dans l’ en- vironnement humide ou humide. Toujours stocker à l’ intérieur, éviter la lumière directe du soleil! WARNING: Risk of Fire.This device contains energy higher than 1 kWh. Do not use in a sleeping room or any habitable space of a dwelling unit./ AVERTISSEMENT: Risque de d'incendie.Cet appareil contient une énergie supérieure à 1 kWh. Ne pas utiliser dans une chambre à coucher ou tout espace habitable d'une unité d'habitation. WARNING: Risk of Fire. This device contains energy higher than 1 kWh. Do not use in a sleeping room or any habitable space of a dwelling unit. AVERTISSEMENT : Risque de d'incendie. Cet appareil contient une énergie supérieure à 1 kWh. Ne pas utiliser dans une chambre à coucher ou tout espace habitable d’ une unité d’ habitation. �.�mm ��*��.�mm ��.�*�.�mm 居中端口 ��*�.�mm 居中端口 �.�mm �.�mm �.�mm��.�mm �.�mm 11-60V 10A MAX. For external power supply Fast / Slow Charge 100-120V~ 50/60Hz ���*��.�mm ��.�*��.�mm ��.�mm��.�mm ��.�*�.�mm 水平居中于接口 USB/WIRELESS OUTPUT AC OUTPUT 1800W Si ne-Wave 11-60V 20A XT60 ��.�*�.�mm FCC ID:2BBDT-SR1KW8L USB-A1+A2 output: 5V 2.4A, 12W max. Total DC output: 500W max. Total output: 1800W max. Protection rating: IP20 Made in China Dongguan Hinen New Energy Technology Co., Ltd. USB-C1/C2 output: 5/9V 3A, 12V 2.5A, 15V 2A, 20V 1.5A, 30W max. USB-C3/C4 output: 5/9/12/15V 3A, 20V 5A, 28V 5A, 140W max. Portable Power Station Model: SR1KW8L-SG2-US Battery capacity: 1024Wh, 51.2V , 20Ah Discharge temperature range: -20-45ºC Charge temperature range: 0-45ºC AC socket x4 (Bypass Mode): 100-120V~, 60Hz, 12A max., 1440W max. Car charger+ XT60 total output power: 378W Max. AC socket x4 (Inverter Mode): 100-120V~, 60Hz, 18A max., 1800W max. AC Input: 100-120V~, 50/60Hz, 12A max., 1440W max. PV charge XT60 terminal: 11-60V 20A max., 800W max. PV charge 7909 terminal: 11-60V 10A max., 400W max. XT60 terminal output: 12.6V 30A max., 378W max. Car charger output: 12.6V 10A max., 126W max. Power input/output: 40-57.6V 23A charge, 40A discharge (max.) Wireless charger output: 25W 此部分蓝色:丝印白色 这做丝印 2.65 ��.�*��mm 居中 此部分蓝色:镭雕 ��.��mm ��.��mm ��.��*��.��mm 注意:根据实际QI认证进行丝印具体型号! Qi� Wireless Charger Model: MPP��-�TJNC Input:��V �.�A Output: ��W Max FCC ID: A�X-MPP��-�TJNC Made in China ��.�mm ��.�mm �.�mm�.�mm �.�mm�.�mm �.�mm �.�mm �.�mm ��.�mm ��.�mm �.�mm �.��mm �.��mm �mm�mm ��.�mm ��mm ��.�*�.�mm SR1KW8LSG2US012317C00001 二维码示意尺寸 �x�mm SN号位置示意尺寸 ��.�x�.�mm 二维码示意尺寸 �x�mm SN号位置示意尺寸 ��.�x�.�mm 根据客户产品实物实际是否带wifi,选择对应的SN号命名规格。 客户图档只能保留一个命名规则。 SN号命名规则示例(通用型): SR1KW8LSG2US SR1KW8LSG2US 012317 C 00001 产品 版本号 产品型号 生产年 2023年23表示 制造地 5位流水号 十进制 同周内累计 下周从1开始 C 中国 不变 生产周 如17周 如同周内:生产最小台数:1; 生产最大台数:99999; SN号命名规则示例(用于户外电源不带WiFi功能): 012317 C 00001NW 产品 版本号 产品型号 生产年 2023年23表示 制造地5位流水号 十进制 同周内累计 下周从1开始 C 中国 不变 不带 WiFi 生产周 如17周 如同周内:生产最小台数:1; 生产最大台数:99999; ��.�mm ���.�mm
Internal BLE+2.4G WiFi Antenna Wireless charging Antenna
EUT Specification FCC ID: 2BBDT-SR1KW8L Characteristics Description Product Name Portable Power Station Model number SR1KW8L-SG2-US Power Supply 120V/60Hz Operating Frequency Range 113-205KHz for Phone charging 360KHz for Phone charging Modulation Technique ASK Antenna Type Coil Antenna Device category Portable (<20cm separation) Mobile (>20cm separation) Others ___ Antenna diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Evaluation applied MPE Evaluation SAR Evaluation Applicable Standard: FCC Part 1(1.1310), Part 2(2.1093) and KDB 680106 D01 Wireless Power Transfer v04 2 / 7 Applicable Requirement: Three different categories of transmitters are defined by the FCC in OET Bulletin 65. These categories are fixed installation, mobile, and portable and are defined as follows: Fixed Installations: fixed location means that the device, including its antenna, is physically secured at a permanent location and is not able to be easily moved to another location. Additionally, distance to humans from the antenna is maintained to at least 2 meters. Mobile Devices: a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to be generally used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structures and the body of the user or nearby persons. Transmitters designed to be used by consumers or workers that can be easily re-located, such as a wireless modem operating in a laptop computer, are considered mobile devices if they meet the 20 centimeter separation requirement. The FCC rules for evaluating mobile devices for RF compliance are found in 47 CFR §2.1091. Portable Devices: a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable device requirements are found in Section 2.1093 of the FCC's Rules (47 CFR§2.1093). The FCC also categorizes the use of the device as based upon the user’s awareness and ability to exercise control over his or her exposure. The two categories defined are Occupational/ Controlled Exposure and General Population/Uncontrolled Exposure. These two categories are defined as follows: Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. The phrase fully aware in the context of applying these exposure limits means that an exposed person has received written and/or verbal information fully explaining the potential for RF exposure resulting from his or her employment. With the exception oftransient persons, this phrase also means that an exposed person has received appropriate training regarding work practices relating to controlling or mitigating his or her exposure. Such training is not required for transient persons, but they must receive written and/or verbal information and notification (for example, using signs) concerning their exposure potential and appropriate means available to 3 / 7 mitigate their exposure. The phrase exercise control means that an exposed person is allowed to and knows how to reduce or avoid exposure by administrative or engineering controls and work practices, such as use of personal protective equipment or time averaging of exposure. General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. Licensees and applicants are responsible for compliance with both the occupational/controlled exposure limits and the general population/uncontrolled exposure limits as they apply to transmitters under their jurisdiction. Licensees and applicants should be aware that the occupational/controlled exposure limits apply especially in situations where workers may have access to areas in very close proximity to antennas and access to the general public may be restricted. In lieu of evaluation with the general population/uncontrolled exposure limits, amateur licensees authorized under part 97 of this chapter and members of his or her immediate household may be evaluated with respect to the occupational/controlled exposure limits in this section, provided appropriate training and information has been provided to the amateur licensee and members of his/her household. Other nearby persons who are not members of the amateur licensee's household must be evaluated with respect to the general population/uncontrolled exposure limits. 4 / 7 Test Setup Block Test Procedure 1.Connect the EUT and equipment as above diagram of test configuration. 2.EUT was placed on a table, and the measure probe was placed at a measurement distance of 20cm from the EUT to the center of the probe. 3.Power on the measuring probe, the EUT was set at the maximum field strength emission state. 4.The EUT was put in different directions (Left, Right, Front, Rear, Top and Bottom) toward to the measure probe. The distance from the top of the EUT to the probe is 20CM, and the distance from other directions is 20cm.Measure the value of field strength. 5.Record the worst data of the different directions. 5 / 7 Measuring Device and Test Equipment Used Equipment Manufacturer Model No. Serial No. Last Cal. Due Date E&H-Field Probe(9kHz-30M Hz) Narda EHP-200A 180ZX11012 2025/08/28 2026/08/27 Description of Support Device No. Equipment Manufacturer Model No. Serial No. Remark 1 phone Xiao Mi Mi 10 / Load…
Text truncated - open the document above for the full version.
东莞市汉文电子科技电子有限公司 Han Wen TECHNOLOGY LTD 地址:东莞市石碣镇石单南路128号 Address: No.128 Shidan South Road, Shijie Town, Dongguan TEL: 0769-81804939 FAX: 0769-81381716 样品规格承认书 SAMPLE SPECIFICATION FOR APPROVAL 客户名称 /Customer 东莞市海能电子有限公司/DONGGUAN CE LINK LIMITED 客户编号 /Part Name H281410000484 编号 /Part Name A-2020-012 规格 /Part No. 42.5xT0.5x21.5x39.3x8.4uHx0.08x65Px11TS-L7mm 版本 /Rev. A0 制定日期 /Date 2025-11-28 客户承认签章 / Customer Approved And Signature 本厂确认 / Han wen Approved HanPing Guo 1. 送样的原因 / Sample Submission Reason ̈ 1.新规格/New SPEC ̈ 2.New Material/追加材料 ̈ 3.ECR/变更 2. 变更的规格说明 / Request For New SPEC. 原规格 / Current 希望变更规格 / Request 变更理由 / Reason 备注 /Remark: 1. 本产品符合环境关联物质的管理规定要求 . Above product comply to li yin Environmental material system requirement. 2. 如未回传,则以贵司下订单为样品通过 ! In Event Of No Sign Back,We Will Under Take P.O. As Acceptance To Sample Approval! Form No.:HWQSPE002 Rev:01 产品规格 Product Specification Customer A-2020 Customer H281410000484 Date 2025-11-28 File No. HW-1128001 No. A-2020-012 Spec. 42.5xT0.5x21.5x39.3x8.4uHx0.08x65P x11TS-L7mm Version A0 Page 1/2 1. Size (Unit: mm): 2. electrical specification: No.Parameter Specification Test Instrument 1Ls8.4uH ±10% 100KHZ/1V(uH)2DCR62mΩMAX 3.Material list: Material Namepecificationmanufacturer wire rod0.08*65P ZY tin High temperature lead-free tin YX Hard magnetic+ double sided tape 42.5(±0.5)*5.2±0.2*0.5±0.05mm( LX/KL/HKQ Small magnetic sheet+ double sided tape 20+0/-0.5*0.72±0.05mm LX/KL/HKQ NTC100K/3950 L=23±2mm 上锡3±1mmYTD GlueWhite Glue MY Remark: G 产品规格 Product Specification CustomerA-2020No H281410000484 Date2025-11-28 File No. HW-1128001 No A-2020-012 Spec 42.5xT0.5x21.5x39.3x8.4uHx 0.08x65Px11TS-L7mm Version A0 Page 2/2 1. Size (Unit: cm):
TRF No.: 04-E001-0B TRF Originator: GTG TRF Date: 2023-12-13 Web: www.gtggroup.com E-mail: [email protected] Tel.: 86-400 755 8988 CFR 47 FCC PART 15 SUBPART C TEST REPORT For Portable Power Station MODEL NUMBER: SR1KW8L-SG2-US, PS1800 Pro W-US, M1000, ENPP01800USBL- P, TA-PN1K8QI-US-BK1, TA-PN1K8QI-US-BG1 REPORT NUMBER: E04A25110685F00703 ISSUE DATE: January 26, 2026 FCC ID: 2BBDT-SR1KW8L Prepared for CE LINK LIMITED ROOM 2204 22/F TUNG CHIU COMMERCIAL CENTRE 193 LOCKHART ROAD WANCHAI HONG KONG SAR CHINA Prepared by Guangdong Global Testing Technology Co., Ltd. Room 101-105, 203-210, Building 1, No.2, Keji 8 Road, Songshan Lake Park, Dongguan city, Guangdong, People’s Republic of China, 523808 This report is based on a single evaluation of the submitted sample(s) of the above mentioned Product, it does not imply an assessment of the production of the products. This report shall not be reproduced, except in full, without the written approval ofGuangdong Global Testing Technology Co., Ltd. REPORT NO.: E04A25110685F00703 Page 2 of 36 TRF No.: 04-E001-0B Global Testing , Great Quality. Revision History Rev. Issue Date Revisions Revised By V0 January 26, 2026 Initial Issue REPORT NO.: E04A25110685F00703 Page 3 of 36 TRF No.: 04-E001-0B Global Testing , Great Quality. Summary of Test Results Test Item Limit/Requirement Result Antenna Requirement FCC Part 15.203 Pass AC Power Line Conducted Emission FCC Part 15.207 Pass 20dB Bandwidth FCC Part 15.215 Pass Radiated Emission FCC Part 15.205/15.209 Pass Note: 1. N/A: In this whole report not applicable. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <CFR 47 FCC PART 15 SUBPART C> when <Accuracy Method> decision rule is applied. REPORT NO.: E04A25110685F00703 Page 4 of 36 TRF No.: 04-E001-0B Global Testing , Great Quality. CONTENTS 1. ATTESTATION OF TEST RESULTS..................................................................................... 5 2. TEST METHODOLOGY......................................................................................................... 6 3. FACILITIES AND ACCREDITATION..................................................................................... 6 4. CALIBRATION AND UNCERTAINTY ................................................................................... 7 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 7 5. EQUIPMENT UNDER TEST .................................................................................................. 8 5.1. DESCRIPTION OF EUT ........................................................................................... 8 5.2. TEST MODE ........................................................................................................... 10 5.3. SUPPORT UNITS FOR SYSTEM TEST ................................................................. 10 5.4. SETUP DIAGRAM .................................................................................................. 10 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 11 7. RADIATED TEST RESULTS ............................................................................................... 12 7.1. Radiated Spurious Emission ................................................................................... 16 8. AC POWER LINE CONDUCTED EMISSION ...................................................................... 28 9. 20DB BANDWIDTH ............................................................................................................. 33 10. ANTENNA REQUIREMENT ................................................................................... 36 REPORT NO.: E04A25110685F00703 Page 5 of 36 TRF No.: 04-E001-0B Global Testing , Great Quality. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: CE LINK LIMITED Address: ROOM 2204 22/F TUNG CHIU COMMERCIAL CENTRE 193 LOCKHART ROAD WANCHAI HONG KONG SAR CHINA Manufacturer Information Company Name: Dongguan Hinen New Energy Technology Co., Ltd Address: No.24 Dongkang Road, Dalingshan Town, Dongguan City, Guangdong Province, China EUT Information Product Description: Portable Power Station Model: SR1KW8L-SG2-US Series Model: PS1800 Pro W-US, M1000, ENPP01800USBL-P, TA-PN1K8QI- US-BK1, TA-PN1K8QI-US-BG1 Brand: See the model list for details Sample Received Date: November 12, 2025 Sample Status: Normal Sample ID: A25110685 007 Date of Tested: November 12, 2025 to December 10, 2025 APPLICABLE STANDARDS STANDARD TEST RESULTS CFR 47 FCC PART 15 SUBPART C Pass Prepared By: Checked By: Poal Chen Alan He Project Engineer Laboratory Leader Approved By: Shawn Wen Laboratory Manager REPORT NO.: E04A25110685F00703 Page 6 of 36 TRF No.: 04-E001-0B Global Testing , Great Quality. 2. TEST METHODOLOGY All tests were performed in accordance with the standard CFR 47 FCC PART 15 SUBPART C 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 6947.01) Guangdong Global Testing Technology Co., Ltd. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1343) Guangdong Global Testing Technology Co., Ltd. has been recognized to perform compliance testing on equipment subject to Supplier's Declaration of Conformity (SDoC) and Certification rules ISED (Company No.: 30714) Guangdong Global Testing Technology Co., Ltd. has been registered and fully described in a report filed with ISED. The Company Number is 30714 and the test lab Conformity Assessment Body Identifier (CABID) is CN0148. Note: All tests measurement facilities use to collect the measurement data are located at Room 101-105, 203-210, Building 1, No.2, Keji 8 Road, Songshan Lake Park, Dongguan city, Guangdong, People’s Republic of China, …
Text truncated - open the document above for the full version.
328 W Palm Ave. · Monrovia, California, 91016 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.113 MHz - 0.205 MHz | - |
| 2 | 15C | 0.36 MHz - 0.36 MHz | - |

Portable Power Station
Equipment Class
DTS - Digital Transmission System
Portable Power Station
Equipment Class
DTS - Digital Transmission System
Portable Power Station
Equipment Class
DTS - Digital Transmission System
Portable Power Station
Equipment Class
DTS - Digital Transmission System