FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Hu Yang Intelligent Innovation Co.,Ltd./
  3. 2BBET-PF300

2BBET-PF300Automatic pet feeder

Shenzhen Hu Yang Intelligent Innovation Co.,Ltd.
Automatic pet feeder - FCC ID 2BBET-PF300 - Shenzhen Hu Yang Intelligent Innovation Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 02, 2023
Application Purpose
Original Equipment
Date of Application
Jul 02, 2023
Equipment Note
Automatic pet feeder
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Hu Yang Intelligent Innovation Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

封面 封底 PFA0004-2二代单盆宠物喂食器说明书 XTUOES(深圳) 尺寸:170*120mm 印刷:单黑 材质:128克铜版纸 共24P 装钉 Automatic pet feeder PF300 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party. Responsible for compliance could void the user’s authority to operate this equipment. (Example- use only shielded interface cables when connecting to computer or peripheral devices). This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: The equipment complies with FCC Radiation exposure limits set forth for uncontrolled enviroment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. .

Attestation Statements

ShenzhenHuYangIntelligentInnovationCo.,Ltd. 301,building3,DCCculturalandcreativepark,PinghuStreet,LonggangDistrict,ShenzhenCity.China TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB986446D01. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 2023-06-09 Towhomitmayconcern: We,ShenzhenHuYangIntelligentInnovationCo.,Ltd.herebycertifythattheequipmentforwhich authorizationissoughtFCCID:2BBET-PF300isnot“covered”equipmentprohibitedfromreceiving anequipmentauthorizationpursuantto§2.903oftheFCCrules. Wealsocertifythat,asofthedateofthefilingoftheapplication,wearenotidentifiedontheCovered List(https://www.fcc.gov/supplychain/coveredlist)asanentityproducing“covered”equipment. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirements listedunder§2.911(b)and(d)(5)and(6). Sincerely, JaChen Signature JaChen Projectmanager ShenzhenHuYangIntelligentInnovationCo.,Ltd. 6 2 _ [ m o d e l ] C o v e r e d E q u _ 2 . 9 1 1 ( d ) ( 5 ) ( i ) a n d ( i i ) - U , V 0 2

Cover Letter(s)

Shenzhen Hu Yang Intelligent Innovation Co.,Ltd. Add: 301, building 3, DCC cultural and creative park, Pinghu Street, Longgang District, Shenzhen City. China Date: 2023-6-9 FCC ID: 2BBET-PF300 Dear Sir/Madam, We, Shenzhen Hu Yang Intelligent Innovation Co.,Ltd. Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Automatic pet feeder Model no.: PF300, PF301, PF302, PF303, PF304, PF305, PF306, PF307, PF308, PF309, PF300A, PF301A, PF302A, PF303A, PF304A, PF305A, PF306A, PF307A, PF308A, PF309A Sincerely, Name/Title: Ja Chen/Project manager Company: Shenzhen Hu Yang Intelligent Innovation Co.,Ltd. Address: 301, building 3, DCC cultural and creative park, Pinghu Street, Longgang District, Shenzhen City. China Phone: +86 13538022829 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

CONFIDENTIALITYREQUEST forCertificationServiceinUSA FederalCommunicationCommission EquipmentAuthorizationDivision,ApplicationProcessingBranch 7435OaklandMillsRoad Columbia,MD21046 Date:<2023-6-9> PursuanttoParagraphs§0.457and0.459oftheCommission’sRules(47C.F.R.)and Section§552(b)(4)oftheFreedomofInformationAct,werequestsconfidentialityfor thefollowingproducts: FCCIDModelname 2BBET-PF300PF300 Fortheproductstatedabove,werequestthatthefollowinginformationbeheld confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term ConfidentialityDays ExternalPhotos InternalPhotos BlockDiagram Schematics TestSetupPhotos User’sManual PartsList TuneUp OperationalDescriptions Thelong-termconfidentialityexhibitscontainourtradesecretsandproprietary informationthatcouldbeofbenefittoourcompetitors. Theshort-termconfidentialityonthebasisofensuringthatbusinesssensitive informationremainsconfidentialuntiltheactualmarketingofournewdevice. Ifyouhaveanyquestions,pleasefeelfreetocontactmeattheaddressshownbelow. Sincerely, JaChen Name/Title: JaChen/Projectmanager Company: ShenzhenHuYangIntelligentInnovationCo.,Ltd. Address: 301,building3,DCCculturalandcreativepark,Pinghu Street,LonggangDistrict,ShenzhenCity.China Phone: +8613538022829 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

ShenzhenHuYangIntelligentInnovationCo.,Ltd. 301,building3,DCCculturalandcreativepark,PinghuStreet,Longgang District,ShenzhenCity.China Date:2023-6-9 FCCID:2BBET-PF300 ModelNumber:PF300 To: FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD ToWhomItMayConcern, We,ShenzhenHuYangIntelligentInnovationCo.,Ltd.,declarethatthisEUT (FCCID:2BBET-PF300)doesn’thaveAdHocmodefunctionon “non-US/Canadafrequencies”.Inaddition.Thefrequencyselectionfeatureis disabledbyfirmwarefordevicesmarkedtotheUS/Canada.ForDTSpartofthis device,onlychannels1-11willbeusedinNorthAmerica,Countrycode selectionisdisabled. Shouldyouhaveanyquestionsorcommentsregardingthismatter,pleasehave ShenzhenHuYangIntelligentInnovationCo.,Ltd. 301,building3,DCCculturalandcreativepark,PinghuStreet,Longgang District,ShenzhenCity.China mybestattention. Sincerely, JaChen Name/Title: JaChen/Projectmanager Company: ShenzhenHuYangIntelligentInnovationCo.,Ltd. Address: 301,building3,DCCculturalandcreativepark,Pinghu Street,LonggangDistrict,ShenzhenCity.China Phone: +8613538022829 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

ShenzhenHuYangIntelligentInnovationCo.,Ltd. 301,building3,DCCculturalandcreativepark,PinghuStreet,LonggangDistrict,ShenzhenCity.China FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 2023-06-09 Towhomitmayconcern: We,ShenzhenHuYangIntelligentInnovationCo.,Ltd.theundersigned,herebyauthorizeEurofins ProductServiceGmbHtoactonourbehalfinallmattersrelatingtoapplicationsforequipment authorizationFCCID:2BBET-PF300includingthesigningofalldocumentsrelatedtothese matters. AnyandallactscarriedoutbyEurofinsProductServiceGmbHonourbehalfshallhavethesame effectasactsofourown. Bysigningthisapplicationform,weagreetoEurofins’currentvalidGeneralTermsandConditions (AGB),TestingandCertificationRegulations(PZO)whichcanbeviewedonfollowingwebsite www.eurofins.de/eeorretrievedonrequest. Wealsoherebycertifythatnopartytothisapplicationissubjecttoadenialofbenefits,includingFCC benefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.862. Sincerely, JaChen Name/Title: JaChen/Projectmanager Company: ShenzhenHuYangIntelligentInnovationCo.,Ltd. Address: 301,building3,DCCculturalandcreativepark,Pinghu Street,LonggangDistrict,ShenzhenCity.China Phone: +8613538022829 Fax: N/A E-Mail: [email protected]

External Photos

FCC ID: 2BBET-PF300 TB-RF-074-1.0 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of EUT FCC ID: 2BBET-PF300 TB-RF-074-1.0 Photo 3 Appearance of EUT Photo 4 Appearance of EUT FCC ID: 2BBET-PF300 TB-RF-074-1.0 Photo 5 Appearance of EUT Photo 6 Appearance of EUT

ID Label/Location Info

FCC ID: 2BBET-PF300 TB-RF-074-1.0 Appendix IID Label FCC ID: 2BBET-PF300 Model: PF300 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. FCC ID: 2BBET-PF300 TB-RF-074-1.0 Appendix II ID Label Location

Internal Photos

FCC ID: 2BBET-PF300 TB-RF-074-1.0 Appendix IV EUT Internal Photographs Photo 7 Internal of EUT Photo 8 Internal of EUT FCC ID: 2BBET-PF300 TB-RF-074-1.0 Photo 9 Appearance of PCB Photo 10 Appearance of PCB FCC ID: 2BBET-PF300 TB-RF-074-1.0 Photo 11 Appearance of PCB Photo 12 Appearance of PCB Antenna Reserve a place FCC ID: 2BBET-PF300 TB-RF-074-1.0 Photo 13 Appearance of PCB Photo 14 Appearance of Adapter

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202303-0318-7 Page: 1 of 3 TB-RF-075-1.0 1 A/F., Building.6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao’an, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Maximum Permissible Exposure Evaluation FCC ID: 2BBET-PF300 1. Client Information Applicant : Shenzhen Hu Yang Intelligent Innovation Co.,Ltd. Address : 301, building 3, DCC cultural and creative park, Pinghu Street,Longgang District, Shenzhen, China Manufacturer : Shenzhen Hu Yang Intelligent Innovation Co.,Ltd. Address : 301, building 3, DCC cultural and creative park, Pinghu Street,Longgang District, Shenzhen, China 2. General Description of EUT EUT Name : Automatic pet feeder Models No. : PF300, PF301, PF302, PF303, PF304, PF305, PF306, PF307, PF308, PF309, PF300A, PF301A, PF302A, PF303A, PF304A, PF305A, PF306A, PF307A, PF308A, PF309A Model Different : All PCB boards and circuit diagrams are the same, with differences in appearance and model names. Product Description : Operation Frequency: 802.11b/g/n(HT20): 2412MHz~2462MHz Number of Channel: 802.11b/g/n(HT20):11 channels Antenna Gain: 2.54dBi PCB Antenna Power Rating : Adapter Model#1: PLH-A918 Input:AAC100-240V~50/60Hz, 0.18A Output: DC 5V1A Adapter Model#2: VS0075-0500100VUB Input:AAC100-240V~50/60Hz, 0.3A Output: DC 5V1A Li-ion Polymer Battery : DC 1.5V by AA battery*4 Software Version : MCU:40201 WIFI:3.00015.2 Hardware Version : PF300-MCU-V1.0 PF300-UI-V1.0 Connecting I/O Port(S) : : Please refer to the User's Manual Report No.: TBR-C-202303-0318-7 Page: 2 of 3 TB-RF-075-1.0 MPE Calculations for WIFI 1. EUT Operation Condition: Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 2. Exposure Evaluation: Equation from page 18 of OET Bulletin 65, Edition 97-01 S=(PG)/4πR 2 Where S: power density P: power input to the antenna G: power gain of the antenna in the direction of interest relative to an isotropic radiator. R: distance to the center of radiation of the antenna 3. Simultaneous transmission MPE Considerations According to KDB447498: All transmitters and antennas in the host must be either evaluated for MPE compliance, by measurement or computational modeling, or qualify for the standalone MPE test exclusion in section 7.1. Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modeled or measured field strengths or power density, is ≤ 1.0. This means that: ∑ of MPE ratios ≤ 1.0 4. Test Result: 2.4G WiFi worst reported. Mode Frequency (MHz) Conducted Power(max) (dBm) Turn-up Power (dB) Max tune up power (dBm) [P] ANT Gain (dBi) [G] Distance (cm) [R] Power Density (mW/ cm 2 ) [S] Limit of Power Density (mW/ cm 2 ) (S) 802.11b 2412 17.184 17±1 18 2.54 20 0.02253 1 2437 17.864 17±1 18 2.54 20 0.02253 1 2462 17.179 17±1 18 2.54 20 0.02253 1 802.11g 2412 16.724 16±1 17 2.54 20 0.01790 1 2437 16.640 16±1 17 2.54 20 0.01790 1 2462 16.846 16±1 17 2.54 20 0.01790 1 802.11 n(HT20) 2412 16.456 16±1 17 2.54 20 0.01790 1 2437 16.608 16±1 17 2.54 20 0.01790 1 2462 16.285 16±1 17 2.54 20 0.01790 1 Report No.: TBR-C-202303-0318-7 Page: 3 of 3 TB-RF-075-1.0 5. Conclusion: As specified in Table 1B of 47 CFR 1.1310- Limits for Maximum Permissible Exposure (MPE), Limits for General Population/ Uncontrolled Exposure Frequency Range (MHz) Power density (mW/ cm 2 ) 300-1,500 F/1500 1,500-100,000 1.0 For 2.4WIFI:2412~2462 MHz and Bluetooth LE MPE limit S: 1mW/ cm 2 The MPE is calculated as 0.02253 < limit 1mW / cm 2 . So, RF exposure limit warning or SAR test are not required. The EUT will only be used with a separation of 20cm or greater between the antenna and nearby persons and can therefore be considered a mobile transmitter per 47 CFR2.1091 (b). The RF Exposure Information page from the manual is included here for reference. Note For a more detailed features description, please refer to the RF Test Report. 6. Conclusion: The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device. -----END OF REPORT-----

Test Report

AntennaSpecification Manufacture:TUYA ProductName:WBR3Antenna AntennaType:PCB TestDate:2021.05.20 Testedby:LongWang Approvedby:Licco Content 1.GeneralDescription.................................................................................1 2.TestConfigurations...................................................................................2 2.1TestEnvironment............................................................................2 2.2TestEquipment...............................................................................2 2.3TestPrinciple...................................................................................2 3.TestResults..............................................................................................3 3.1GainandEfficiency..........................................................................3 3.2RadiationPattern............................................................................4 4.AntennaDimensions................................................................................6 5.EUTPhoto................................................................................................6 6.TestSetupPhoto......................................................................................7 1 1.GeneralDescription ManufacturerHangzhouTuyaInformationTechnologyCo.,Ltd Address Room701,Building3,MoreCenter,No.87GuDunRoad, Hangzhou,Zhejiang,China TestLocation Room106,Building3,LetongSciencePark,No.500, QiuyiRoad,BinjiangDistrict,Hangzhou ProductNameWBR3Antenna Productmodel WBR3 AntennaType PCBAntenna TestItems Gain;Efficiency;RadiationPattern TestFrequency 2400-2500MHz TestStandard ANSI/IEEEStd149-1979 2 2.TestConfigurations 2.1TestEnvironment Temperature(°C)25 Humidity(%RH)60 AtmosphericPressure(kPa)100.5 2.2TestEquipment TestSystemTEM24Multi-probeMicrowaveChamber TestInstrumentAgilentE5071B 2.3TestPrinciple 3 3.TestResults 3.1GainandEfficiency Frequency(MHz)PeakGain(dBi)Efficiency(%) 2400 1.6252.29 2410 1.7152.17 2420 1.9353.14 2430 1.9854.16 2440 2.0057.62 2450 2.1759.64 2460 2.4561.55 2470 2.3860.64 2480 2.5462.86 2490 2.3059.85 2500 2.4960.41 4 3.2RadiationPattern Phi02D Phi902D 5 Theta902D 2480MHz3D 6 4.AntennaDimensions 5.EUTPhoto 7 6.TestSetupPhoto

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 1 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 RF Test Data for 2.4G WiFi (Conducted Measurements) General Description of EUT Product Name: Automatic pet feeder Test Model: PF300 Sample ID: RW-C-202303-0318-5-2# Environmental Conditions Temperature: 24°C Relative Humidity: 50% Test Voltage: DC 5V Test Engineer: Liujiming Note: For a more detailed features description, please refer to the report TBR-C-202303-0318-5 The report only show the worst case data Duty Cycle Condition Mode Frequency (MHz) Antenna Duty Cycle (%) Correction Factor (dB) 1/T (kHz) NVNT b 2412 Ant1 99.04 0.04 0.08 NVNT b 2437 Ant1 98.96 0.05 0.08 NVNT b 2462 Ant1 98.96 0.05 0.08 NVNT g 2412 Ant1 94.06 0.27 0.49 NVNT g 2437 Ant1 94.09 0.26 0.48 NVNT g 2462 Ant1 94.52 0.24 0.48 NVNT n(HT20) 2412 Ant1 93.66 0.28 0.52 NVNT n(HT20) 2437 Ant1 93.66 0.28 0.52 NVNT n(HT20) 2462 Ant1 93.66 0.28 0.52 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 2 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 Test Graphs Duty Cycle NVNT b 2412MHz Ant1 Duty Cycle NVNT b 2437MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 3 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 Duty Cycle NVNT b 2462MHz Ant1 Duty Cycle NVNT g 2412MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 4 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 Duty Cycle NVNT g 2437MHz Ant1 Duty Cycle NVNT g 2462MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 5 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 Duty Cycle NVNT n(HT20) 2412MHz Ant1 Duty Cycle NVNT n(HT20) 2437MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 6 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 Duty Cycle NVNT n(HT20) 2462MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 7 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT b 2412 Ant1 17.184 30 Pass NVNT b 2437 Ant1 17.864 30 Pass NVNT b 2462 Ant1 17.179 30 Pass NVNT g 2412 Ant1 16.724 30 Pass NVNT g 2437 Ant1 16.64 30 Pass NVNT g 2462 Ant1 16.846 30 Pass NVNT n(HT20) 2412 Ant1 16.456 30 Pass NVNT n(HT20) 2437 Ant1 16.608 30 Pass NVNT n(HT20) 2462 Ant1 16.285 30 Pass Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 8 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant1 8.56 0.5 Pass NVNT b 2437 Ant1 8.52 0.5 Pass NVNT b 2462 Ant1 9.07 0.5 Pass NVNT g 2412 Ant1 16.33 0.5 Pass NVNT g 2437 Ant1 16.36 0.5 Pass NVNT g 2462 Ant1 16.33 0.5 Pass NVNT n(HT20) 2412 Ant1 17.54 0.5 Pass NVNT n(HT20) 2437 Ant1 17.57 0.5 Pass NVNT n(HT20) 2462 Ant1 17.57 0.5 Pass Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 9 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2437MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 10 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 -6dB Bandwidth NVNT b 2462MHz Ant1 -6dB Bandwidth NVNT g 2412MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 11 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 -6dB Bandwidth NVNT g 2437MHz Ant1 -6dB Bandwidth NVNT g 2462MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 12 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 -6dB Bandwidth NVNT n(HT20) 2412MHz Ant1 -6dB Bandwidth NVNT n(HT20) 2437MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 13 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 -6dB Bandwidth NVNT n(HT20) 2462MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202303-0318-5 Page: 14 of 49 FCC ID: 2BBET-PF300 TB-RF-074-1.0 Occupied Channel Bandwidth Condition Mode Frequency (MHz) Antenna 99% OBW (MHz) NVNT b 2412 Ant1 14.089 NVNT b 2437 Ant1 14.095 NVNT b 2462 Ant1 14.086 NVNT g 2412 Ant1 1…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202303-0318-5 Page: 1 of 45 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Radio Test Report FCC ID: 2BBET-PF300 Report No. : TBR-C-202303-0318-5 Applicant : Shenzhen Hu Yang Intelligent Innovation Co., Ltd. Equipment Under Test (EUT) EUT Name : Automatic pet feeder Model No. : PF300 Series Model No. : PF301, PF302, PF303, PF304, PF305, PF306, PF307, PF308, PF309, PF300A, PF301A, PF302A, PF303A, PF304A, PF305A, PF306A, PF307A, PF308A, PF309A Brand Name : ---- Sample ID : RW-C-202303-0318-5-1# & RW-C-202303-0318-5-2# Receipt Date : 2023-05-23 Test Date : 2023-05-23 to 2023-06-08 Issue Date : 2023-06-09 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10: 2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Witness Engineer : Seven Wu Engineer Supervisor : Ivan Su Engineer Manager : Ray Lai This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202303-0318-5 Page: 2 of 45 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT ............................................................................. 5 1.1 Client Information ................................................................................................................. 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 6 1.4 Description of Support Units .............................................................................................. 7 1.5 Description of Test Mode .................................................................................................... 7 1.6 Description of Test Software Setting ................................................................................ 9 1.7 Measurement Uncertainty .................................................................................................. 9 1.8 Test Facility ......................................................................................................................... 10 2. TEST SUMMARY ..................................................................................................................... 11 3. TEST SOFTWARE ................................................................................................................... 11 4. TEST EQUIPMENT .................................................................................................................. 12 5. CONDUCTED EMISSION TEST ........................................................................................... 14 5.1 Test Standard and Limit .................................................................................................... 14 5.2 Test Setup ........................................................................................................................... 14 5.3 Test Procedure ................................................................................................................... 14 5.4 Deviation From Test Standard ......................................................................................... 15 5.5 EUT Operating Mode ........................................................................................................ 15 5.6 Test Data ............................................................................................................................. 15 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 16 6.1 Test Standard and Limit .................................................................................................... 16 6.2 Test Setup ........................................................................................................................... 18 6.3 Test Procedure ................................................................................................................... 19 6.4 Deviation From Test Standard ......................................................................................... 20 6.5 EUT Operating Mode ........................................................................................................ 20 6.6 Test Data ............................................................................................................................. 20 7. RESTRICTED BANDS REQUIREMENT ............................................................................. 21 7.1 Test Standard and Limit .................................................................................................... 21 7.2 Test Setup ........................................................................................................................... 21 7.3 Test Procedure ................................................................................................................... 22 7.4 Deviation From Test Standard ......................................................................................... 23 Report No.: TBR-C-202303-0318-5 Page: 3 of 45 TB-RF-074-1.0 7.5 EUT Operating Mode ........................................................................................................ 23 7.6 Test Data ............................................................................................................................. 23 8. BANDWIDTH TEST .....................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2BBET-PF300 TB-RF-074-1.0 Appendix V EUT Test Photographs Photo of Setup for Radiated Emission (Below 1 GHz) Photo of Setup for Radiated Emission (Above 1 GHz) FCC ID: 2BBET-PF300 TB-RF-074-1.0 Photo of Setup for Conducted Emission -----END OF THE REPORT-----

Contact Information

Applicant

Ja Chen
[email protected]13538022829Fax: N/A

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]---

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz61.20 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.