Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
C2023-021.3 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following information. Read all instructions before using (this appliance). DANGER – To reduce the risk of electric shock: 1) Always unplug this appliance from the electrical outlet immediately after using and before cleaning. WARNING – To reduce the risk of burns, fire, electric shock, or injury to persons: 1) An appliance should never be left unattended when plugged in. Unplug from outlet when not in use, and before putting on or taking off parts. 2) Do not operate under blanket or pillow. Excessive heating can occur and cause fire, electric shock, or injury to persons. 3) Close supervision is necessary when this appliance is used by, on, or near children, invalids, or disabled persons. 4) Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 5) Never operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a service centre for examination and repair. 6) Do not carry this appliance by supply cord or use cord as a handle. 7) Keep the cord away from heated surfaces. 8) Never operate the appliance with the air openings blocked. Keep the air openings free of lint, hair, and the like. 9) Never drop or insert any object into any opening. 10) Do not use outdoors. 11) Do not operate where aerosol (spray) products are being used or where oxygen is being administered. 12) To disconnect, turn all controls to the off position, then remove plug from outlet. WARNING: Connect this appliance to a properly grounded outlet only. See Grounding Instructions. FOR HOUSEHOLD USE ONLY C2023-021.3 GROUNDING INSTRUCTIONS This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This product is for use on a nominal 120-V circuit and has a grounding plug that looks like the plug illustrated in sketch A. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product. C2023-021.3 FCC Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. RF warning for Mobile device This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. C2023-021.3 IC Caution CAN ICES-003(B) / NMB-003(B) RSS-Gen Issue 3 December 2010"&"CNR-Gen 3e edition Décembre 2010: English: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1) This device may not cause interference, and 2) This device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. French: Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1) L’appareil ne doit pas produire de brouillage, et 2) L’utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. C2023-021.3 About Neurosonic Neurosonic relaxation metho…
Text truncated - open the document above for the full version.
Rev 1/26/2023 Oy Neurosonic Finland Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 6-12-2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BBGY-GEN2 Oy Neurosonic Finland Ltd. ("the applicant")certifies that the equipment for which authorization is sought is not“covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicantsignature) (Applicant printed name) Jean Smedman Rev 1/26/2023 Oy Neurosonic Finland Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 6-12-2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BBGY-GEN2 Oy Neurosonic Finland Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Jean Smedman
Oy Neurosonic Finland Ltd. Saaristonkatu 1, 90100 Oulu, Finland China Date: 6-12-2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BBGY-GEN2 US Agent – Attestation Statement / Part 2.911(d)(7) Oy Neurosonic Finland Ltd.certifies, that as of 6-12-2023, we have designated FCC US Agent, LLC to accept service of process on our behalf for FCC ID: 2BBGY-GEN2. Oy Neurosonic Finland Ltd., accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. FCC US Agent, LLC, accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of Oy Neurosonic Finland Ltd. for FCC ID: 2BBGY-GEN2. Designated Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Company: Oy Neurosonic Finland Ltd. Designated Agent: FCC US Agent, LLC Company Representative: Jean Smedman Designated Agent Representative: Tim Payne Signature: [Signature] Signature:
Rev 11/20/07 Oy Neurosonic Finland Ltd. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2BBGY-GEN2 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram, Schematics, Operational Description, Block Diagram Operation Description schematic diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, Jean Smedman Oy Neurosonic Finland Ltd.
Oy Neurosonic Finland Ltd. Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2023-06-02 SUBJECT: FCC Application for FCC ID: 2BBGY-GEN2 To Whom It May Concern: We, the undersigned, hereby authorize Lisa Wang at EMTEK (SHENZHEN) CO., LTD. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by EMTEK (SHENZHEN) CO., LTD. on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Client’s name / title : Jean Smedman Contact information / address: Oy Neurosonic Finland Ltd./Saaristonkatu 1, 90100 Oulu, Finland
EUTEXTERNALPHOTOGRAPHS ----------------Theend----------------
WBV2023-070 Neurosonic Controller UL label content and placement 76,2 mm 37 mm
EUT INTERNAL PHOTOGRAPHS ----------------The end---------------- PCB antenna
FCCID:2BBGY-GEN2 RFEXPOSUREEVALUATION AccordingtoFCC1.1310,FCC1.1307andKDB447498D04InterimGeneralRF ExposureGuidancev01 1.WithrespecttothelimitsonhumanexposuretoRFprovidedin§1.1310ofthischapter, applicantstotheCommissionforthegrantormodificationofconstructionpermits,licenses orrenewalsthereof,temporaryauthorities,equipmentauthorizations,oranyother authorizationsforradiofrequencysourcesmusteither: (A)Determinethattheyqualifyforanexemptionpursuantto§1.1307(b)(3); (B)PrepareanevaluationofthehumanexposuretoRFradiationpursuantto§1.1310 andincludeintheapplicationastatementconfirmingcompliancewiththelimitsin§ 1.1310;or (C)PrepareanEnvironmentalAssessmentifthoseRFsourceswouldcausehuman exposuretolevelsofRFradiationinexcessofthelimitsin§1.1310. 2.RFExposureInformation:Theradiatedoutputpowerofthisdevicemeetsthelimitsof FCC/ICradiofrequencyexposurelimits.Thisdeviceshouldbeoperatedwithaminimum separationdistanceof20cm(8inches)betweentheequipmentandaperson'sbody. §1.1307(b)(3)(i)(A)forRFevaluationlimit: Theavailablemaximumtime-averagedpowerisnomorethan1mW,regardlessofseparationdistance.This exemptionmaynotbeusedinconjunctionwithotherexemptioncriteriaotherthanthoseinparagraph (b)(3)(ii)(A)ofthissection.Medicalimplantdevicesmayonlyusethisexemptionandthatinparagraph (b)(3)(ii)(A); §1.1307(b)(3)(i)(b)forRFevaluationlimit: Ortheavailablemaximumtime-averagedpoweroreffectiveradiatedpower(ERP),whicheverisgreater,is lessthanorequaltothethresholdP th (mW)describedinthefollowingformula.Thismethodshallonlybe usedatseparationdistances(cm)from0.5centimetersto40centimetersandatfrequenciesfrom0.3GHzto 6GHz(inclusive).P th isgivenby: §1.1307(b)(3)(i)(C)forRFevaluationlimit: RFSourcefrequency(MHz)ThresholdERP(watts) 0.3-1.341,920R2. 1.34-303,450R2/f2. 30-3003.83R2 300-15000.0128R2f. 1500-10000019.2R*R(0.768W) 3.MeasurementofRFconductedPower theavailablemaximumtime-averagedpoweroreffectiveradiatedpower(ERP),whicheverisgreater: Antennagain:-0.48dBi Mode Tune-upAV power(dBm) Maxtune-upAV power(dBm) Maxtune-up AVPower(mw) Maxtune-upERP Power(mw) BLE-1.98dBm0dBm0.63mW0.61mW Note:ERP=EIRP–2.15dB, Generally,thesequencetoapplyforsingleRFsourcesincludesthefollowingsteps: Q1:determinationof1mWblanketexemptionunder§1.1307(b)(3)(i)(A) A1:YES,Itisgreaterthan1mw. Q2:determinationofexemptionundertheMPE-based§1.1307(b)(3)(i)(C)if1)isnotmet A2:NO,Itislessthan19.2R*RmW,sohavebeenexemption. Q3:determinationofexemptionundertheSAR-based§1.1307(b)(3)(i)(B)ifboth1)and2)arenotmet A3:NO;Theexemptionhasbeensatisfied. Q4: streamlinedtestreductionproceduresforevaluationbytheFCCLaboratorywhichmayreference currentresearchbasedonbandwidth,etc.if1),2),and3)arenotmet A4:NO;Theexemptionhasbeensatisfied. Q5:evaluationbySARmeasurementorcomputationif1),2),3),and4)arenotmet A5:NO;Theexemptionhasbeensatisfied. Q6: EnvironmentalAssessment(EA)ifnoneofthepreviousaremet(i.e.,exposurelimitswouldbe exceeded) A6:NO;Theexemptionhasbeensatisfied. 4.AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedto evaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiationas specifiedin§1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) AverageTime (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 1.1Friistransmissionformula:Pd=(Pout*G)\(4*pi*R 2 ) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainmW G=Numericgainoftheantennarelativetoisotropicantenna Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorin20cm PdthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainofthendtotalpowerinput totheantenna,throughthecalculation,wewillknowthedistancewheretheMPElimitis reached. RFExposureInformation:Theradiatedoutputpowerofthisdevicemeetsthelimitsof FCC/ICradiofrequencyexposurelimits.Thisdeviceshouldbeoperatedwithaminimum separationdistanceof20cm(8inches)betweentheequipmentandaperson'sbody. 1.2MeasurementResult NotApplicable ----------------THEENDOFREPORT---------------
ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page1of10 TestingReport CustomerName:OyNeurosonicFinlandLtd. ProductName:NeurosonicController SampleModel:Gen2 ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2023.6.29 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page2of10 Version VersionNo.DateDescriptionFormulateApproval A02023.06.29Forthefirsttime,formulateZkrisEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults.....................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................8 3.3.1Typicalfreespaceefficiencyandgain......................................................................8 3.3.2Typicalfreespaceradiationpattern...........................................................................8 (Thefollowingisblank)..............................................................................................................10 ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page3of10 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page4of10 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2023.3.142025.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2023.5.112024.5.10 1.4Testenvironment Temperature 22.5°C Humidity 58%RH Pressure 100.20kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page5of10 2.SampleInformation 2.1Clientinformation Name OyNeurosonicFinlandLtd. Address Saaristonkatu1,90100Oulu,Finland Contacts JeanSmedman Tel +358400480635 E-mail [email protected] Manufacturer OyNeurosonicFinlandLtd. 2.2DescriptionofEUT(S) ProductName NeurosonicController SampleModel Gen2 AntennaSize / SerialNo. / AntennaType PCBAntenna TestItem Antennagain;Efficiency;Radiationpattern FrequencyRange 2400-2500MHz ReceivedDate 2023.06.28 TestDate 2023.06.29 Remark ThelengthoftheRFcableis90mm ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page6of10 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page7of10 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty Antennagain±0.72dB Radiationefficiency±0.72dB ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page8of10 3.3Testdata 3.3.1Typicalfreespaceefficiencyandgain 3.3.2Typicalfreespaceradiationpattern (1)X-ZPlane(unit:dBi): Frequency/MHz 24002410242024302440245024602470248024902500 PeakGain/dBi -0.48-0.57-0.64-0.79-0.93-1.26-1.27-1.33-1.77-2.01-1.98 Efficiency/% 39.3837.3536.7436.0035.1134.2133.9132.9130.0129.5129.15 ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page9of10 (2)Y-ZPlane(unit:dBi): (3)X-YPlane(unit:dBi): ReportNo.:RFI-LAB-RF-202306-FF38 QP030-E41 Page10of10 (4)TypicalFreeSpace3DRadiationPatternat2.4GHz(unit:dBi): -------------------------------------…
Text truncated - open the document above for the full version.
Report No. ENS2304040157W00101R Page 1 of 51 Ver.1.0 TEST REPORT Product Name : Neurosonic Controller Model Number : Gen2 FCC ID : 2BBGY-GEN2 IC : 30679-GEN2 Prepared for : Oy Neurosonic Finland Ltd. Address : Saaristonkatu 1, 90100 Oulu, Finland Prepared by : EMTEK (SHENZHEN) CO., LTD. Address : Building 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China Tel: (0755) 26954280 Fax: (0755) 26954282 Report Number : ENS2304040157W00101R Date(s) of Tests : April 14, 2023 to May 13, 2023 Date of issue : May 23, 2023 $二维码$ Report No. ENS2304040157W00101R Page 2 of 51 Ver.1.0 Table of Contents 1 TEST RESULT CERTIFICATION ....................................................................................................... 3 2 EUT TECHNICAL DESCRIPTION ..................................................................................................... 5 3 SUMMARY OF TEST RESULT .......................................................................................................... 6 4 TEST METHODOLOGY ..................................................................................................................... 7 4.1 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................. 7 4.2 MEASUREMENT EQUIPMENT USED ....................................................................................... 7 4.3 DESCRIPTION OF TEST MODES .............................................................................................. 8 5 FACILITIES AND ACCREDITATIONS ............................................................................................... 9 5.1 FACILITIES ................................................................................................................................. 9 5.2 EQUIPMENT ............................................................................................................................... 9 5.3 LABORATORY ACCREDITATIONS AND LISTINGS .................................................................. 9 6 TEST SYSTEM UNCERTAINTY ...................................................................................................... 10 7 SETUP OF EQUIPMENT UNDER TEST ......................................................................................... 11 7.1 RADIO FREQUENCY TEST SETUP 1 ....................................................................................... 11 7.2 RADIO FREQUENCY TEST SETUP 2 ....................................................................................... 11 7.3 CONDUCTED EMISSION TEST SETUP .................................................................................. 14 7.4 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ...................................................... 15 7.5 SUPPORT EQUIPMENT ........................................................................................................... 15 8 TEST REQUIREMENTS .................................................................................................................. 16 8.1 ON TIME AND DUTY CYCLE .................................................................................................... 16 8.2 DTS 6DB BANDWIDTH ............................................................................................................. 18 8.3 DTS 99% BANDWIDTH ............................................................................................................ 20 8.4 MAXIMUM PEAK CONDUCTED OUTPUT POWER ................................................................ 22 8.5 MAXIMUM POWER SPECTRAL DENSITY .............................................................................. 25 8.6 UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS .............................. 27 8.7 RADIATED SPURIOUS EMISSION .......................................................................................... 33 8.8 CONDUCTED EMISSIONS TEST ............................................................................................ 48 8.9 ANTENNA APPLICATION ......................................................................................................... 51 Report No. ENS2304040157W00101R Page 3 of 51 Ver.1.0 1 TEST RESULT CERTIFICATION Applicant : Oy Neurosonic Finland Ltd. Address : Saaristonkatu 1, 90100 Oulu, Finland Manufacturer : Oy Neurosonic Finland Ltd. Address : Saaristonkatu 1, 90100 Oulu, Finland EUT : Neurosonic Controller Model Name : Gen2 Trademark : N/A Measurement Procedure Used: APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 2, Subpart J FCC 47 CFR Part 15, Subpart C PASS IC RSS-GEN, Issue 5(04-2018)+A1(03-2019)+A2(02-2021) IC RSS-247 Issue 2(02-2017) PASS The above equipment was tested by EMTEK(SHENZHEN) CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 2, Part 15.247, IC RSS-247 Issue 2 and IC RSS-GEN, Issue 5. The test results of this report relate only to the tested sample identified in this report. Date of Test : April 14, 2023 to May 13, 2023 Prepared by : Una Yu /Editor Reviewer : Joe Xia/Supervisor Approve & Authorized Signer : Lisa Wang/Manager Report No. ENS2304040157W00101R Page 4 of 51 Ver.1.0 Modified History Version Report No. Revision Date Summary Ver.1.0 ENS2304040157W00101R / Original Report Report No. ENS2304040157W00101R Page 5 of 51 Ver.1.0 2 EUT TECHNICAL DESCRIPTION Product: Neurosonic Controller Model Number: Gen2 Sample number: 2# Data Rate : 1Mbps Modulation: GFSK Operating Frequency Range: 2402-2480MHz Number of Channels: 40 Channels Transmit Power Max: -1.98dBm Antenna Type: PCB Antenna Antenna Gain: -0.48dBi Power Supply: DC 15V from adapter Adapter: Model: MKI-1500600C14 Input: 100-240VAC, 50/60Hz, 2.5A Output: 15VDC, 6A Date of Received: April 13, 2023 Tempera…
Text truncated - open the document above for the full version.
TEST SETUP PHOTOGRAPHS Photos of Conducted Emission Measurement Photos of Radiation Emission Measurement Spurious Emission Test Setup (Below 1GHz) Spurious Emission Test Setup (Above 1GHz) ----------------The end----------------
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |