FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN MIDU TECHNOLOGY CO.,LTD/
  3. 2BBKTYYQ-230

2BBKTYYQ-230Digital Wireless Charging Clock

SHENZHEN MIDU TECHNOLOGY CO.,LTD
Digital Wireless Charging Clock - FCC ID 2BBKTYYQ-230 - SHENZHEN MIDU TECHNOLOGY CO.,LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 30, 2023
Application Purpose
Original Equipment
Date of Application
Jul 30, 2023
Equipment Note
Digital Wireless Charging Clock
Frequency Range
0.11100000 - 0.20500000
Company
SHENZHEN MIDU TECHNOLOGY CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual I. Overview 1) 10W wireless charging 2) No PWM output 3) 5 button 4) 1 display screen 5) 1 buzzer 2.Key arrangement and definition Sitting alarm brightness 3.Function description 1、Display screen 1)The display screen displays one sentence every day, with a total of 365 sentences, which are displayed in turn in order, and 365 and 366 display the same sentence. 2)If the alarm clock is turned on, the corresponding alarm clock pattern will be displayed. If the alarm clock 1 is turned on, the pattern of the alarm clock 1 will be lit. 3)This product is used in a 24-hour system. 2、Brightness User Manual 1)After the power is turned on, the display screen lights up. At this time, it plays a beeping sound and enters the power-on state. 2)In the boot state, press the "Brightness" button to adjust the brightness of the display: ① The "Brightness" button is triggered for the first time, and the display brightness is adjusted to "Bright". ② The "Brightness" button is triggered for the second time, and the display brightness is adjusted to "Dark". ③ The "Brightness" button is triggered for the third time, and the display is turned off. ④ The "Brightness" button is triggered for the fourth time, and the brightness of the display is adjusted to "the brightest". ( Power-on default) 3、Set up In the clock state, trigger the "Setting" button, enter the time setting mode, and set the corresponding time through "+" and "-": 1)The first time to trigger the "Settings" button, enter the "time" setting, and the number corresponding to "time" flashes at this time. 2)The second time to trigger the "Settings" button, enter the "Spot" setting, at which time, the number corresponding to "Spot" flashes. 3)The "Settings" button is triggered for the third time and enters the "month" setting. At this time, the number corresponding to "month" flashes. 4)The 4th time to trigger the "Settings" button, enter the "Day" setting, at which time, the number corresponding to "Day" flashes. 5)The fifth time to trigger the "Settings" button and enter the "Year" setting. At this time, the number corresponding to "Year" flashes. 6)Note: After the date of the year is set, the corresponding day of the week will also be displayed. Set the flash to stop flash after 1 minute, and restore the timing function. After entering the set year, month, day and hour, press the addition and subtraction key to stop the time (if you do not press the addition and subtraction, the time will not stop and the timer will not start from 0). At this time, the alarm key will immediately start from 0 User Manual seconds, which is used for the time. 4、+ 1)In the clock state, the triggering "+" button is invalid. 2)In the time and alarm clock setting mode, the "+" button is triggered, and the corresponding number displayed is gradually increased. 5、- 1)In the clock state, the triggering "-" button is invalid. 2)In the time and alarm clock setting mode, the "-" button is triggered, and the corresponding number displayed is gradually reduced. 6、Alarm 1)In the state of the clock, a. The first triggers the "alarm" button, displays the alarm clock in 1, 5 seconds to return to the display clock status, b. The second trigger, the alarm clock is displayed for 2, 5 seconds to return to the display clock status, C. The third trigger, return to the display clock Display the status of alarm clock 1 or alarm clock 2. ① After entering the alarm clock 1 or 2, first enter the alarm clock switch setting, and the alarm clock shows "ON" or "OFF" flash. At this time, the "+" or "-" sign is triggered to change the ON or OFF status. ② The "Settings" button is triggered for the first time, entering the alarm hour setting, and the alarm clock shows "hour" flash. At this time, the "+" or "-" sign is triggered to change the hour. ③ The second time to trigger the "Settings" button, enter the alarm clock minute setting, and the alarm clock shows a "minute" flash. At this time, the "+" or "-" sign is triggered to change the minute. User Manual ④ The third time to trigger the "Settings" button, enter the alarm clock switch setting again, and the alarm clock shows "ON" or "OFF" flash. At this time, the "+" or "-" sign is triggered to change the ON or OFF status. 2) When the alarm clock is up, the buzzer starts to work. At this time, the "alarm clock" button is triggered, and the buzzer stops working without pressing it for 1 minute. FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. The equipment complies with FCC radiation exposure limits set forth fo…

Text truncated - open the document above for the full version.

Attestation Statements

SHENZHEN MIDU TECHNOLOGY CO.,LTD 2.911 (d)(7)USA Agent v1.4 Section 2.911(d)(7) USA Agent for Service of Process Company name: SHENZHEN MIDU TECHNOLOGY CO.,LTD Address: 1001C, 10/F, Shenhua Transportation Bldg, 7014 Beihuan Ave., Meijing Community, Meilin St., Futian Dist., Shenzhen, Guangdong, China Product Name: Digital Wireless Charging Clock FCC ID: 2BBKTYYQ-230 Model(s): YYQ-230 2.911(d)(7) USA Designated Agent for Service of Process We, [SHENZHEN MIDU TECHNOLOGY CO.,LTD] (“the applicant”) designate [InspireCo Ecommerce] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either we the grantee have permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name:InspireCo Ecommerce USA Address: MQJ1 4412 W 300 N GREENFIELD, IN 46140-7099 FRN Number:0033953043 Contact Name: Mr catalino B Javier III Telephone No: (604) 418-0706 Email:[email protected] Applicant Company name: SHENZHEN MIDU TECHNOLOGY CO.,LTD Address:1001C, 10/F, Shenhua Transportation Bldg,7014 Beihuan Ave., Meijing Community, Meilin St., Futian Dist., Shenzhen, Guangdong, China FCC Grantee Code:0033835158 Contact Name: Xiaofeng Zeng Telephone No: +8613322935309 Email: [email protected] SHENZHEN MIDU TECHNOLOGY CO.,LTD 2.911 (d)(7)USA Agent v1.4 Signature: Title:Owner Signature: Title: Sales Person Date:14/07/2023 Date14/07/2023 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: SHENZHEN MIDU TECHNOLOGY CO.,LTD Address: 1001C, 10/F, Shenhua Transportation Bldg 7014 Beihuan Ave, Meijing Community, Meilin St., Futian Dist., Shenzhen, China Phone: +86-13322935309 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-07-27 Signature Date Printed Name of Signee: Xiaofeng Zeng Company: SHENZHEN MIDU TECHNOLOGY CO.,LTD Address: 1001C, 10/F, Shenhua Transportation Bldg 7014 Beihuan Ave, Meijing Community, Meilin St., Futian Dist., Shenzhen, China Phone: +86-13322935309 Fax: N/A Email: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BBKTYYQ-230 YYQ-230 We, applicant Company Name: SHENZHEN MIDU TECHNOLOGY CO.,LTD Address: 1001C, 10/F, Shenhua Transportation Bldg 7014 Beihuan Ave, Meijing Community, Meilin St., Futian Dist., Shenzhen, China Phone: +86-13322935309 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-07-27 Signature Date Printed Name of Signee: Xiaofeng Zeng Company: SHENZHEN MIDU TECHNOLOGY CO.,LTD Address: 1001C, 10/F, Shenhua Transportation Bldg 7014 Beihuan Ave, Meijing Community, Meilin St., Futian Dist., Shenzhen, China Phone: +86-13322935309 Fax: N/A Email: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BBKTYYQ-230 YYQ-230 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Parts Lists • the Tune Up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2023-07-27 Signature Date Printed Name of Signee: Xiaofeng Zeng Company: SHENZHEN MIDU TECHNOLOGY CO.,LTD Address: 1001C, 10/F, Shenhua Transportation Bldg 7014 Beihuan Ave, Meijing Community, Meilin St., Futian Dist., Shenzhen, China Phone: +86-13322935309 Fax: N/A Email: [email protected]

Cover Letter(s)

SHENZHEN MIDU TECHNOLOGY CO.,LTD 1001C, 10/F, Shenhua Transportation Bldg 7014 Beihuan Ave, Meijing Community, Meilin St., Futian Dist., Shenzhen, China Date: July 27, 2023 FCC ID: 2BBKTYYQ-230 Model Number: YYQ-230 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, SHENZHEN MIDU TECHNOLOGY CO.,LTD hereby declare that our product (Digital Wireless Charging Clock) Model Number: YYQ-230 meet item 5.2 of KDB 680106v03r01 as follow; Requirements of KDB 680106 D01 Yes / No Description Power transfer frequency is less than 1 MHz Yes The device operate in the frequency range is 111 KHz – 205 KHz Output power from each primary coil is less than or equal to 15 watts. Yes The maximum output power of the primary coil is 10W The system may consist of more than one source primary coils, charging one or more clients. If more than one primary coil is present, the coil pairs may be powered on at the same time. Yes The transfer system includes single coil that is able to detect receiver device Client device is placed directly in contact with the transmitter. Yes Client device is placed directly in contact with the transmitter Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Yes Mobile exposure condition only The aggregate H-field strengths anywhere at or beyond 15 cm surrounding the device, and 20 cm away from the surface from all coils that by design can simultaneously transmit, and while those coils are simultaneously energized, are demonstrated to be less than 50% of the applicable MPE limit. Yes The EUT H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Please contact me if you have any question. SHENZHEN MIDU TECHNOLOGY CO.,LTD 1001C, 10/F, Shenhua Transportation Bldg 7014 Beihuan Ave, Meijing Community, Meilin St., Futian Dist., Shenzhen, China Sincerely, (Signed) Name/Title: Xiaofeng Zeng / Sales person Company: SHENZHEN MIDU TECHNOLOGY CO.,LTD Address: 1001C, 10/F, Shenhua Transportation Bldg 7014 Beihuan Ave, Meijing Community, Meilin St., Futian Dist., Shenzhen, China Tel: +86-13322935309 Fax: N/A E-Mail: [email protected]

External Photos

Page 1 of 4 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 4 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8

ID Label/Location Info

Page 1 of 1 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L5.0cm x 4.0cm) Label Location Digital Wireless Charging Clock Model:YYQ-230 FCC ID:2BBKTYYQ-230

Internal Photos

Page 1 of 9 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity INTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 9 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 9 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 9 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 9 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 9 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 9 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Page 8 of 9 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15 Fig. 16 Coil Antenna Page 9 of 9 FCC ID:2BBKTYYQ-230 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 17

RF Exposure Info

Page 1 of 11 FCC ID:2BBKTYYQ-230 Report No.: LCSA041023287EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report 1. Product Information FCC ID: 2BBKTYYQ-230 Product Name Digital Wireless Charging Clock Model Number YYQ-230 Power Supply Input: DC 5V Wireless Output:10W(max) Modulation Type ASK Frequency Range 111.0~205.0KHz Operation Frequency 113.9 KHz Antenna Type Coil Antenna Hardware version / Software version / Accessories / Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Consumer wireless power transfer devices approved under Part 18 in some cases have to demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed according to the operating configurations of the wireless system and the exposure conditions of users and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at maximum output power. The RF exposure requirements must be determined in conjunction with the device operating characteristics, according to the mobile and portable exposure requirements in Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the FCC rules. 2) Based on the design and implementation of the power transfer application, it must be clearly identified if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of the rules may apply. 3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Page 2 of 11 FCC ID:2BBKTYYQ-230 Report No.: LCSA041023287EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements. Existing SAR systems and test procedures are generally intended for measurements above 100 MHz. While numerical modeling can be an alternative, the constraints of substantial computational resources at low frequencies could introduce further limitations. Under these circumstances, including operations below 100 kHz, the Commission may consider a combination of analytical analysis, field strength, radiated and conducted power measurements, in conjunction with some limited numerical modeling to assess compliance. 5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation they should contact the FCC Laboratory with sufficient system operating configuration details to determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures. Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons, information on device design, implementation, operating configurations, exposure conditions of users and bystanders are needed to determine the evaluation and testing requirements. In addition, the influence of nearby objects may also need consideration according to the wireless power transfer system implementation; for example, the effects of placing the device, its coils or radiating elements on or near metallic surfaces 3. Evaluation Limit 3.1 Refer evaluation method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices FCC CFR 47 part 18.107:Indusial, Scientific, and Medical Equipment Page 3 of 11 FCC ID:2BBKTYYQ-230 Report No.: LCSA041023287EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3.2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for…

Text truncated - open the document above for the full version.

Test Report

1.MECHANICAL DIMENSION (UNIT:mm) 2.SCHEMATICS: ABC D2EHI 49±1.020.0±0.50.81±0.05 42±33±1.52.6MAX 3.WINDING: 1.1底部印字100 STE P TAP E REMAR K N1 4.ELECTRICAL SPECIFICATION: ITEM SPEC SPECIFICATION FOR SHENZHEN MIDU TECHNOLOGY CO.,LTD START-FINISH S-F L The coil was added with a magnetic 10TS (Ref) Qvalue TURNSWIRE TYPE HI-POT 6.3uH±10% 100KHz,0.25V AT 25°C silk-covered wire 2UEW DCR 75mΩ Max TES T CON D S-F All measurements are based were performed radiated and therefore additional antenna gain documents is not required.

Test Report

Page 1 of 25 FCC ID:2BBKTYYQ-230 Report No.: LCSA041023287EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For SHENZHEN MIDU TECHNOLOGY CO.,LTD Digital Wireless Charging Clock Test Model: YYQ-230 Prepared for : SHENZHEN MIDU TECHNOLOGY CO.,LTD Address : 1001C, 10/F, Shenhua Transportation Bldg, 7014 Beihuan Ave., Meijing Community, Meilin St., Futian Dist., Shenzhen, Guangdong, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : June 13, 2023 Number of tested samples : 2 Serial number : A041023287-1, A041023287-2 Date of Test : June 13, 2023~ June 14, 2023 Date of Report : June 15, 2023 Page 2 of 25 FCC ID:2BBKTYYQ-230 Report No.: LCSA041023287EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15C Report Reference No. ................ : LCSA041023287EA Date Of Issue ................................. : June 15, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : SHENZHEN MIDU TECHNOLOGY CO.,LTD Address .......................................... : 1001C, 10/F, Shenhua Transportation Bldg, 7014 Beihuan Ave., Meijing Community, Meilin St., Futian Dist., Shenzhen, Guangdong, China Test Specification Standard ......................................... : FCC CFR 47 PART 15C Test Report Form No. .................... : LCSEMC-1.0 TRF Originator................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : Digital Wireless Charging Clock Trade Mark ..................................... : inspireCo Test Model ...................................... : YYQ-230 Power Supply ................................. : Input: DC 5V Wireless Output:10W(max) Result ........................................... : Positive Compiled by: Supervised by: Approved by: Jack Liu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 25 FCC ID:2BBKTYYQ-230 Report No.: LCSA041023287EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Xiaofeng Zeng
[email protected]13322935309Fax: 13322935309

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.111 MHz - 0.205 MHz-
Confidentiality
Long Term