Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AP11 Kit AP129 AP109 K88 K129 AP11 Kit AP11 Kit AP11 Kit AP11 Kit IC Caution: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le prĂ©sentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitationestautorisĂ©e aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareildoit accepter tout brouillageradioĂ©lectriquesubi, mĂȘmesi le brouillageest susceptible d'encompromettre le fonctionnement. FCC Caution: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement.The device can be used in portable exposure condition without restriction.
C5266091_X24_Ed.2 1/1 ShenZhenGDWuLianTechnologyCo.,Ltd. âAttestationStatementsâ TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 TheCommissionadoptedrulesthatprohibitequipmentauthorizationforâcoveredâ telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentitiesidentified ontheCommissionâsCoveredList 1 ,whichisperiodicallyupdated.SeetheCoveredListformore details.ThisAttestationStatementistoconfirmthatwefollowtheSection2.911(d)(5)(i)-(ii) Applicant Companyname:ShenZhenGDWuLianTechnologyCo.,Ltd. Granteecode:2BBMJ FCCID:2BBMJ-AP11KIT ContactName:RayLei Address:Room343,A2Building,HuafengZhiguHangchengHightechIndustrialPark, HangchengStreet,BaoâAnDistrict,ShenzhenCity,GuangdongProvince,China TelephoneNo:+8618988760864 FaxNo:+8618988760864 Email:[email protected] i.[ShenZhenGDWuLianTechnologyCo.,Ltd.](âtheapplicantâ)certifiesthat theequipmentforwhichauthorizationissoughtisnotâcoveredâequipment prohibitedfromreceivinganequipmentauthorizationpursuanttosection 2.903oftheFCCrules.Theapplicantmustsignthiscertification. ii.[ShenZhenGDWuLianTechnologyCo.,Ltd.](âtheapplicantâ)certifiesthat, asofthedateofthefilingoftheapplication,theapplicant[isnot](asa specificallynamedentityoranyofitssubsidiariesoraffiliates)identifiedon theCoveredListasanentityproducingâcoveredâequipment.Theapplicant mustsignthiscertification. [ShenZhenGDWuLianTechnologyCo.,Ltd.](âtheapplicantâ)certifiesthat,asof thedateofthefilingoftheapplication,theapplicant[isnot]identifiedonthe CoveredListasanentityproducingâcoveredâequipment. Date:2023/06/26 ApplicantâsName:RayLei Title:ProductManager Signature 1 TheCommissionâsCoveredListispublishedbythePublicSafetyandHomelandSecurityBureauandpostedonthe Commissionâswebsite.ThisCoveredList,whichisperiodicallyupdated,identifiesparticularequipment,producedby particularentities,thatconstitutesâcoveredâequipment.https://www.fcc.gov/supplychain/coveredlist
ShenZhenGDWuLianTechnologyCo.,Ltd. ProductSimilarityDeclaration Productname: AP11KeyboardCase Modelname:AP11Kit,AP129,AP109,K88,K129 FCCID:2BBMJ-AP11KIT We(ShenZhenGDWuLianTechnologyCo.,Ltd.)herebystate thatallthemodelsareelectricalidenticalincludingthesame softwareparameterandhardwaredesign(i.e.,circuitdesign,PCB Layout,RFmodule/circuit,antennatype(s)andantennalocation, componentsonPCB,etc.,),samemechanicalstructureand design(includingproductenclosure,materials,etc.,),theonly differenceisthemodelname,andtheappearancecoloris different. Signature: Name:RayLei Title:ProductManager Shenzhen,June26,2023
C5266091_X8_Ed.1 1/1 LetterofAuthorization ShenZhenGDWuLianTechnologyCo.,Ltd. Company:ShenZhenGDWuLianTechnologyCo.,Ltd. Address:Room343,A2Building,HuafengZhiguHangchengHightechIndustrial Park,HangchengStreet,Bao'AnDistrict,ShenzhenCity,GuangdongProvince,China ProductName:AP11KeyboardCase ModelNumber:AP11Kit,AP129,AP109,K88,K129 FCCIdentifier:2BBMJ-AP11KIT WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:RayLeiDate:2023-06-26 Title:ProductManager Signatureofapplicant:
C5266091_X10_Ed.2 1/1 ShenZhenGDWuLianTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2023-06-26 Subject:RequestforConfidentiality FCCID:2BBMJ-AP11KIT ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo â BlockDiagram ââ Schematics ââ TestReportNoNo TestSetupPhotosNo â UserâsManual â NOTE 1 â InternalPhotos â NOTE 1 â PartsList/TuneUp ââ RFExposureInfoNoNo OperationalDescription ââ CoverLetter(s)NoNo SDRSoftware/SecurityInfo â No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodofdaysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, C5266091_X10_Ed.2 1/1 Signature: Name:RayLei Title:ProductManager
FCC ID:2BBMJ-AP11KIT FCC ID:2BBMJ-AP11KIT FCC ID:2BBMJ-AP11KIT FCC ID:2BBMJ-AP11KIT FCC ID:2BBMJ-AP11KIT FCC ID:2BBMJ-AP11KIT FCC ID:2BBMJ-AP11KIT
· · · · · · · ··
FCC ID:2BBMJ-AP11KIT 1 / 5 FCC ID:2BBMJ-AP11KIT 2 / 5 ANT FCC ID:2BBMJ-AP11KIT 3 / 5 FCC ID:2BBMJ-AP11KIT 4 / 5 FCC ID:2BBMJ-AP11KIT 5 / 5
Page 1 of 2 RF EXPOSURE EVALUATION FCC ID:2BBMJ-AP11KIT Product Name : AP11 Keyboard Case Model Name : AP11 Kit, AP129,AP109,K88,K129 Model difference : The model name is different, and the appearance color is different. Bluetooth Version : 5.2 Operating frequency : 2402-2480MHz Numbers of Channel : 40 channels For DTS Antenna Type : PCB Antenna Antenna Gain : -0.58dBi Type of Modulation : GFSK Power supply : Input:DC5V 240mA Hardware Version : N/A Software Version : N/A Page 2 of 2 Standard Requirement According to § 15.247(i) and § 1.1307b(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commissionâs guidelines. See KDB 447498 D01 General RF Exposure Guidance v06, section 4. 3. 1. The 1-g and 10-g SAR test exclusion thresholds for 100MHz to 6GHz at test separation distances †50mm are determined by: [ (max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]*[ âf(GHz)] â€3.0 for 1-g SAR and â€7.5 for 10-g SAR extremity SAR, where â« f(GHz) is the RF channel transmit frequency in GHz â« Power and distance are rounded to the nearest mW and mm before calculation â« The result is rounded to one decimal place for comparison. The test exclusions are applicable only when the minimum test separation distance is †50mm and for transmission frequencies between 100MHz and 6GHz. When the minimum test separation distance is <5mm, a distance of 5mm is applied to determine SAR test exclusion. Routine SAR evaluation refers to that specifically required by § 2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to quality for TCB approval. Channel (MHz) Maximum output power (dBm) Tune up tolerance (dBm) Max Tune Up Power (mW) Distance (mm) Calculation results Limit Operating Mode 2402 0.44 0.45 ± 1 1.396368 5 0.432829 3 BLE According to KDB 447498, no stand-alone required for BT antenna, and no simultaneous SAR measurement is required. Signature Ronnie Liu EMC Manager Date: 2023-06-25
Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Horizontal Vertical 2400MHz 2400MHz2500MHz2400MHz2400MHz 2500MHz Center Frequency -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dB Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) test model: SP-S10BT Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432
Page 1 of 60 FCC TEST REPORT FCC ID:2BBMJ-AP11KIT Product : AP11 Keyboard Case Model Name : AP11 Kit, AP129, AP109, K88, K129 Brand : N/A Report No. : PTC23051210201E-FC01 Prepared for ShenZhen GD WuLian Technology Co., Ltd. Room 343,A2 Building, Huafeng Zhigu Hangcheng High tech Industrial Park, Hangcheng Street, BaoâAn District,Shenzhen City,Guangdong Province,China Prepared by Precise Testing & Certification Co., Ltd. Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC23051210201E-FC01 Page 2 of 60 1 TEST RESULT CERTIFICATION Applicantâs name : ShenZhen GD WuLian Technology Co., Ltd. Address : Room 343,A2 Building, Huafeng Zhigu Hangcheng High tech Industrial ParkïŒHangcheng Street, Bao'An District,Shenzhen City,Guangdong Province,China Manufacture's name : ShenZhen GD WuLian Technology Co., Ltd. Address : Room 343,A2 Building, Huafeng Zhigu Hangcheng High tech Industrial ParkïŒHangcheng Street, Bao'An District,Shenzhen City,Guangdong Province,China Product name : AP11 Keyboard Case Model name : AP11 Kit, AP129, AP109, K88, K129 Standards : FCC CFR47 Part 15 Section 15.247 Test procedure : ANSI C63.10:2013 Test Date : May. 22, 2023 to Jun. 14, 2023 Date of Issue : Jun. 25, 2023 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Simon Pu / Engineer Technical Manager: Ronnie Liu / Manager Report No.: PTC23051210201E-FC01 Page 3 of 60 Contents Page 1 TEST RESULT CERTIFICATION .............................................................................................................................. 2 2 TEST SUMMARY ......................................................................................................................................................... 5 2.1 TEST SITE ........................................................................................................................................................... 6 3 GENERAL INFORMATION ..................................................................................................................................... 7 3.1 GENERAL DESCRIPTION OF E.U.T. .................................................................................................................... 7 3.2 CHANNEL LIST .................................................................................................................................................... 7 4 EQUIPMENT DURING TEST .................................................................................................................................. 9 4.1 EQUIPMENTS LIST ............................................................................................................................................ 9 4.2 MEASUREMENT UNCERTAINTY ......................................................................................................................... 11 4.3 DESCRIPTION OF SUPPORT UNITS ................................................................................................................... 12 5 CONDUCTED EMISSION ......................................................................................................................................... 13 5.1 E.U.T. OPERATION ........................................................................................................................................... 13 5.2 EUT SETUP ...................................................................................................................................................... 13 5.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................................. 14 5.4 MEASUREMENT PROCEDURE ........................................................................................................................... 14 5.5 CONDUCTED EMISSION LIMIT ........................................................................................................................... 14 5.6 MEASUREMENT DESCRIPTION .......................................................................................................................... 14 5.7 CONDUCTED EMISSION TEST RESULT ............................................................................................................. 14 6 RADIATED SPURIOUS EMISSIONS ..................................................................................................................... 17 6.1 EUT OPERATION .............................................................................................................................................. 17 6.2 TEST SETUP ..................................................................................................................................................... 18 6.3 SPECTRUM ANALYZER SETUP .......................................................................................................................... 19 6.4 TEST PROCEDURE ............................................................................................................................................ 20 6.5 SUMMARY OF TEST RESULTS .......................................................................................................................... 22 7 CONDUCT BAND EDGE AND SPURIOUS EMISSIONS MEASUREMENT ................................................... 29 7.1 TEST PROCEDURE ............................................................................................................................................ 29 7.2 TEST SETUP .....................................................................................âŠ
Text truncated - open the document above for the full version.
FCC ID:2BBMJ-AP11KIT 1 / 2 ConductedEmissions RadiatedSpuriousEmissions TestFrequencyFromBelow30MHz FCC ID:2BBMJ-AP11KIT 2 / 2 TestfrequencyfromAbove1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.11 mW |