FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Healthtech Holdings Limited/
  3. 2BBN2-RH-A

2BBN2-RH-AiWell

Healthtech Holdings Limited
iWell - FCC ID 2BBN2-RH-A - Healthtech Holdings Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 06, 2023
Application Purpose
Original Equipment
Date of Application
Jul 06, 2023
Equipment Note
iWell
Frequency Range
2402.00000000 - 2480.00000000
Company
Healthtech Holdings Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Instructions DIRECTORY 1. Charging 2. Connecting via Bluetooth 3. Usage, Maintenance and Upkeep 4. Device Information 5. Safety and Product Information 5.1 Attention 5.2 Disclaimer 5.3 Limitation of Liability 5.4 Import and Export Control 5.5 Environmental Protection This information is for reference only and does not constitute any form of commitment. In case of any inconsistency between this information and the official website description, please refer to the official website description without further notice. This product is not a medical device, and the health data and suggestions provided are only for reference, not as a basis for diagnosis and treatment. Due to individual differences, if you experience skin discomfort while wearing, please stop wearing and consult a doctor. 1. Charging Align the metal contactor of the charging cable with the charging port on the ring, connect the other end of the cable to the charger, and turn on the power. The charging indicator light remains on during charging and turns off when fully charged. 2. Connecting via Bluetooth Turn on the Bluetooth on your smartphone using the settings. Open the iWell APP, tap the + button in the top-right corner of the main page. The APP will scan for iWell ring Bluetooth. Choose the Bluetooth identity of your iWell ring and press the + button to connect and bind it to your APP. Congratulations! iWell shall now automatically connect and work for you. Operating Environment Do not use the device in damp areas or near magnetic fields to avoid internal circuit faults. Do not use this device during thunderstorms, as it may cause equipment malfunctions or electrical shock hazards. Please use this device within the temperature range of -10°C to +45°C. Extreme temperatures can cause equipment malfunctions. Avoid placing the equipment in direct sunlight, such as on a dashboard panel or windowsill. Keep the equipment away from heat sources or exposed sources of ignition, such as electric heaters, microwaves, ovens, water heaters, stoves, candles, or other places that may generate high temperatures. Ensure children or pets do not swallow the device or its accessories to prevent injury, equipment malfunction, or explosion. Child Health The device and its accessories may contain small parts. Please keep them out of reach of children to prevent accidental damage, swallowing of small parts, suffocation, or other hazards. This device is not a toy and should be used under adult supervision. Accessory Requirements Using unauthorized or incompatible power sources, chargers, or batteries may cause fire, explosion, or other hazards. Battery Safety This device is equipped with a non-detachable built-in battery. Please do not attempt to replace the battery yourself to avoid damaging the battery or device. Do not connect metal conductors to the two poles of the battery or touch the battery's end points to avoid short circuits and physical injuries such as burns caused by overheating. Avoid exposing the battery to high temperatures or heat sources such as direct sunlight, space heaters, microwave ovens, ovens, or water heaters, as it may cause an explosion. Do not disassemble or modify the battery, insert foreign objects, or immerse it in water or other liquids, as it may result in battery leakage, overheating, fire, or explosion. In case of battery liquid leakage, avoid skin or eye contact with the leaked liquid. If contact occurs, immediately rinse with water, and seek medical treatment at a hospital. Do not dispose of the battery in fire, as it may cause it to catch fire and explode. Dispose of batteries according to local regulations and do not treat them as household waste, as improper disposal may lead to battery explosion. Prevent children or pets from swallowing the battery to avoid injury or battery explosion. Do not drop, squeeze, or puncture the battery. Avoid subjecting it to external pressure, as this can cause internal short circuits and overheating. Do not use damaged batteries. 3. Usage, Maintenance and Upkeep Keep the equipment and its accessories dry. Do not use external heating devices such as microwaves or hair dryers to dry them. Avoid placing the equipment and its accessories in areas with high or low temperatures, as this may cause equipment malfunctions, fire, or explosion. Avoid subjecting the equipment and its accessories to strong impacts or vibrations to prevent damage and equipment malfunction. Do not use the device in scorching sun, direct sunlight, high temperature, or humid environments. If it gets wet or sweaty, wipe it dry as soon as possible and place it in a ventilated and cool area to dry. Before cleaning and maintenance, stop using the device and disconnect all connections or cables from other devices. Use a soft bristle brush or clean, soft cloth to clean the charging port. Avoid using sharp metal objects that can scratch the coating and affect the charging effect. Do not use strong chemicals, cleaning agents, or detergents to clean the equipment or its accessories. Use a clean and dry soft cloth instead. Avoid prolonged exposure of magnetic stripe cards (e.g., bank cards, phone cards) to the device, as the magnetic field may cause damage to the cards. Do not disassemble or modify the equipment and accessories without authorisation, as it will void the warranty. In case of equipment malfunction, please contact the customer service centre. If the device collides with hard objects or experiences a strong external impact, causing the screen to break, do not touch or attempt to remove the broken part. Keep the equipment and its accessories clean and dry. Wear the device daily and ensure the area in contact with the device is dry and breathable. If you experience discomfort during prolonged continuous wear, remove the device and rest for a period of time or switch hands. If discomfort persists, it is recommended to stop wearing and consult a doctor. Not recommended for snorkelling, hot water showers, hot sp…

Text truncated - open the document above for the full version.

Attestation Statements

Healthtech Holdings Limited Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/6/2023 U.S. Agent Designation Healthtech Holdings Limited acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BBN2- RH-A): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of Healthtech Holdings Limited. Healthtech Holdings Limited with the FRN 0033888702 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. S incerely, Signature Xiaofei Yu Registered personnel Healthtech Holdings Limited Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Healthtech Holdings Limited Address: Forest Lodge Strang Road Isle of Man IM4 4NP, Isle of Man, 999020, United Kingdom Phone: +86-18001589885 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-05 Name / Title: Xiaofei Yu / Registered personnel Company: Healthtech Holdings Limited Address: Forest Lodge Strang Road Isle of Man IM4 4NP, Isle of Man, 999020, United Kingdom Phone: +86-18001589885 Fax: N/A E-Mail: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BBN2-RH-A RH-A, RH-B We, applicant Company Name: Healthtech Holdings Limited Address: Forest Lodge Strang Road Isle of Man IM4 4NP, Isle of Man, 999020, United Kingdom Phone: +86-18001589885 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-05 Name / Title: Xiaofei Yu / Registered personnel Company: Healthtech Holdings Limited Address: Forest Lodge Strang Road Isle of Man IM4 4NP, Isle of Man, 999020, United Kingdom Phone: +86-18001589885 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BBN2-RH-A RH-A, RH-B For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-05 Name / Title: Xiaofei Yu / Registered personnel Company: Healthtech Holdings Limited Address: Forest Lodge Strang Road Isle of Man IM4 4NP, Isle of Man, 999020, United Kingdom Phone: +86-18001589885 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Healthtech Holdings Limited Forest Lodge Strang Road Isle of Man IM4 4NP, Isle of Man, 999020, United Kingdom Date: July 05, 2023 FCC ID: 2BBN2-RH-A Model Number: RH-A, RH-B To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Healthtech Holdings Limited hereby declare that our product (iWell) Model Number: H-A, RH-B board, Schematic, Hardware version, Software version, structure and internal photos are same, named differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name/Title: Mehmet Akif BOZKURT / Manager Company: Healthtech Holdings Limited Address: Forest Lodge Strang Road Isle of Man IM4 4NP, Isle of Man, 999020, United Kingdom Tel: +86-18001589885 Fax: N/A E-Mail: [email protected]

External Photos

Page 1 of 4 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7

ID Label/Location Info

Page 1 of 1 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L0.5cm x 0.5cm) Label Location iWell Model: RH-A FCC ID: 2BBN2-RH-A

Internal Photos

Page 1 of 3 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziw ei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: w [email protected] | Web: w w w.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziw ei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: w [email protected] | Web: w w w.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziw ei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: w [email protected] | Web: w w w.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Antenna

RF Exposure Info

Page 1 of 3 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2BBN2-RH-A Product name : iWell Test Model : RH-A Additional Model No. : RH-B Model Declaration : PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power Supply : Input: DC 5V DC 3.7V by Rechargeable Li-ion Battery, 20mAh Hardware Version : V2 Software Version : V1 Bluetooth : 2402MHz ~ 2480MHz Channel Number : 40 channels for Bluetooth V5.1 (DTS) Channel Spacing : 2MHz for Bluetooth V5.1(DTS) Modulation Type : GFSK for Bluetooth V5.1 (DTS) Bluetooth Version : V5.1 Antenna Type : Chip Antenna Antenna Gain : 2.28dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: Page 2 of 3 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Page 3 of 3 FCC ID: 2BBN2-RH-A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. Conducted Power Results <BT LE> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 3.26 19 2440 3.75 39 2480 4.11 5. Manufacturing Tolerance <BT LE> GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 3.0 3.0 4.0 Tolerance ±(dB) 1.0 …

Text truncated - open the document above for the full version.

Test Report

承 認 書 SPECIFICATION FOR APPROVAL 客戶名稱 CUSTOMER : 客戶料號 CUSTOMER’S P/N : 料號 PART NUMBER : KH-1608-H08 規格 DESCRIPTION : Chip Antenna 1608 MH-Ant 2.45G Type H08 版本 VERSION : V1.0 日期 ISSUE DATE : 2021/03/03 客 戶 承 認 CUSTOMER APPROVED 工 程 部 R&D CENTER 承 認 APPROVAL 確 認 CHECKED 製 作 DRAWN 深圳市金航标电子有限公司 1/12 WWW.BDS666.COM 0755-83044319 赖积任 张松强 严专专 2/12 WWW.BDS666.COM 0755-83044319 1608 Chip antenna For Bluetooth / WLAN Applications Dimension (mm) L 1.70 ± 0.20 W 0.93 ± 0.20 T 0.75 ± 0.20 P/N: KH-1608-H08 3/12 WWW.BDS666.COM 0755-83044319 Part Number Information KH 1608 H 245 H 08 A B C D E F A Product Series Antenna B Dimension L x W 1.6X0.8mm (+-0.2mm) C Material High K material D Working Frequency 2.4 ~ 2.5GHz E Feeding mode Monopole & Single Feeding F Antenna type Type = 08 1. Electrical Specification Remark : Bandwidth & Peak Gain was measured under evaluation board of next page Specification Part Number KH-1608-H08 Central Frequency 2450 MHz Bandwidth 120 (Min.) MHz Return Loss -10(Max) dB Peak Gain 2.28 dBi Impedance 50 Ohm Operating Temperature -40~+110 °C Maximum Power 4 W Resistance to Soldering Heats 10 ( @ 260°C) sec. Polarization Linear Azimuth Beamwidth Omni-directional Termination Cu / Sn (Leadless) 4/12 WWW.BDS666.COM 0755-83044319 2. Recommended PCB Pattern 1. Evaluation Board Dimension (若淨空區夠大,建議在天線尾段加Trace,效能更佳) Unit : mm 2. Evaluation Board Dimension (若淨空區夠大,建議在天線尾段加Trace,效能更佳) 3. Evaluation Board Dimension 5/12 WWW.BDS666.COM 0755-83044319 Suggested Matching Circuit 重要資訊 : 匹配元件建議使用精準度高的電感±0.1~0.3nH、電容±0.1pF 1. Layout Dimensions in Clearance area(Size=5.5*4mm) 50 ohm transmission Line Matching Circuit 2. Layout Dimensions in Clearance area(Size=5.5*4mm) 50 ohm transmission Line Matching Circuit 1~10nH None 0Ω 1.5pF 6/12 WWW.BDS666.COM 0755-83044319 3. Layout Dimensions in Clearance area(Size=5*3mm) 50 ohm transmission Line Matching Circuit FootPrint (Unit : mm) 7/12 WWW.BDS666.COM 0755-83044319 3. Measurement Results Return Loss 8/12 WWW.BDS666.COM 0755-83044319 Radiation Pattern Efficiency Peak Gain Directivity 2400MHz 50.65 % 1.80 dBi 3.95 dBi 2450MHz 53.27 % 2.28 dBi 4.42 dBi 2500MHz 50.32 % 1.77 dBi 4.15 dBi Chamber Coordinate System Y Z X 9/12 WWW.BDS666.COM 0755-83044319 4.Reliability and Test Condictions ITEM REQUIREMENTS TEST CONDITION Solderability 1. Wetting shall exceed 90% coverage 2. No visible mechanical damage Pre-heating temperature:150°C/60sec. Solder temperature:230±5°C Duration:4±1sec. Solder:Sn-Ag3.0-Cu0.5 Flux for lead free: rosin Solder heat Resistance 1. No visible mechanical damage 2. Central Freq. change :within ± 6% 10 ± 0.5 sec. 60 sec . . T E M P ( °C ) 150 °C 2 6 0 °C Pre-heating temperature:150°C/60sec. Solder temperature:260±5°C Duration:10±0.5sec. Solder:Sn-Ag3.0-Cu0.5 Flux for lead free: rosin Component Adhesion (Push test) 1. No visible mechanical damage The device should be reflow soldered(230±5°C for 10sec.) to a tinned copper substrate A dynometer force gauge should be applied the side of the component. The device must with-ST-F 0.5 Kg without failure of the termination attached to component. Component Adhesion (Pull test) 1. No visible mechanical damage Insert 10cm wire into the remaining open eye bend ,the ends of even wire lengths upward and wind together. Terminal shall not be remarkably damaged. Thermal shock 1. No visible mechanical damage 2. Central Freq. change :within ±6% Phase Temperature(°C) Time(min) 1 +110±5°C 30±3 2 Room Temperature Within 3sec 3 -40±2°C 30±3 4 Room Temperature Within 3sec +110°C=>30±3min -40°C=>30±3min Test cycle:10 cycles The chip shall be stabilized at normal condition for 2~3 hours before measuring. Resistance to High Temperature 1. No visible mechanical damage 2. Central Freq. change :within ±6% 3. No disconnection or short circuit. Temperature: +110±5°C Duration: 1000±12hrs The chip shall be stabilized at normal condition for 2~3 hours before measuring. Resistance to Low Temperature 1. No visible mechanical damage 2. Central Freq. change :within ±6% 3. No disconnection or short circuit. Temperature:-40±5°C Duration: 1000±12hrs The chip shall be stabilized at normal condition for 2~3 hours before measuring. Humidity 1. No visible mechanical damage 2. Central Freq. change :within ±6% 3. No disconnection or short circuit. Temperature: 40±2°C Humidity: 90% to 95% RH Duration: 1000±12hrs The chip shall be stabilized at normal condition for 2~3 hours before measuring. 4±1 sec. 60sec TEMP (°C) 150°C 230°C 10/12 WWW.BDS666.COM 0755-83044319 5.Soldering and Mounting Mildly activated rosin fluxes are preferred. The minimum amount of solder can lead to damage from the stresses caused by the difference in coefficients of expansion between solder, chip and substrate. The terminations are suitable for all wave and re-flow soldering systems. If hand soldering cannot be avoided, the preferred technique is the utilization of hot air soldering tools. Recommended temperature profiles for re-flow soldering in Figure 1. Products attachment with a soldering iron is discouraged due to the inherent process control limitations. In the event that a soldering iron must be employed the following precautions are recommended. ‧Preheat circuit and products to 150°C ‧Never contact the ceramic with the iron tip ‧Use a 20 watt soldering iron with tip diameter of 1.0mm ‧280°C tip temperature (max) ‧1.0mm tip diameter (max) ‧Limit soldering time to 3 sec. SOLDERING COOLING NATURAL PRE-HEATING TEMPERATURE(°C) 60~120 s 10s max. 30~60s 250~260 230 180 150 TIME(sec.) Reflow Soldering SOLDERING COOLING NATURAL PRE-HEATING TEMPERATURE(°C) within 3s Gradual cooling 150 TIME(sec.) Iron Soldering Over 60s 350 300 11/12 WWW.BDS666.COM 0755-83044319 6.Packaging Information ◆ Tape Specification: W Ao Bo Ko P F E D D1 Po P2 t 8.0 ±0.30 1.10± 0.05 1.90 ±0.10 1.10± 0.10 4.00 ±0.05 3.50 ±0.05 1.75 ±0.10 1.50 ±0.10 0.00 ±0.10 4.00 ±0.10 2.00 ±0.05 0.23 ±0.05 ◆ Reel Specification: (7’’, Φ180 mm) Tape Width(mm) A(mm) B(mm) C(mm) D(mm) Chip/Reel(pcs) 8 9.0±0.5 6…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 23 FCC ID: 2BBN2-RH-A Report No.: LCSA06083001EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BLE (Conducted Measurement) Product Name: iWell Test Model: RH-A Environmental Conditions Temperature: 23.5  C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Ling Zhu Supervised by: Li Huan Page 2 of 23 FCC ID: 2BBN2-RH-A Report No.: LCSA06083001EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 1M 2402 Ant1 0.708 >=0.5 Pass NVNT BLE 1M 2440 Ant1 0.704 >=0.5 Pass NVNT BLE 1M 2480 Ant1 0.697 >=0.5 Pass Page 3 of 23 FCC ID: 2BBN2-RH-A Report No.: LCSA06083001EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz Ant1 -6dB Bandwidth NVNT BLE 1M 2440MHz Ant1 Page 4 of 23 FCC ID: 2BBN2-RH-A Report No.: LCSA06083001EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 1M 2480MHz Ant1 Page 5 of 23 FCC ID: 2BBN2-RH-A Report No.: LCSA06083001EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402 Ant1 3.26 30 Pass NVNT BLE 1M 2440 Ant1 3.75 30 Pass NVNT BLE 1M 2480 Ant1 4.11 30 Pass Page 6 of 23 FCC ID: 2BBN2-RH-A Report No.: LCSA06083001EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 1M 2402MHz Ant1 Power NVNT BLE 1M 2440MHz Ant1 Page 7 of 23 FCC ID: 2BBN2-RH-A Report No.: LCSA06083001EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Xiaofei Yu
[email protected]18001589885Fax: 85524950

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.60 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power.