2BBQM-COOLERAutomotive Cooler

Dometic (Shenzhen) Electronics Co., Ltd.
Automotive Cooler - FCC ID 2BBQM-COOLER - Dometic (Shenzhen) Electronics Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 11, 2023
Application Purpose
Original Equipment
Date of Application
Dec 11, 2023
Equipment Note
Automotive Cooler
Frequency Range
2402.00000000 - 2480.00000000
Company
Dometic (Shenzhen) Electronics Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GM BT1YL Automotive Console Cooler Manual Automotive Console Cooler Manual ◼ Please read this operating manual carefully before starting to use this device. Place the manual in a safe place for easy viewing. If transferring the fridge to someone else, please hand it over together with this manual. Contents 1 Important Note .................................................................................................. 2 2 Caution ................................................................................................................. 3 GM BT1YL Automotive Console Cooler Manual 1 Important Note Center Console Refrigerator If equipped, the center console refrigerator can only be powered on and accessed using the infotainment screen. The refrigerator mode can only be used while the vehicle is in accessory power or on. If the vehicle is turned off and turned back on, the last refrigerator operating mode will be resumed. A light inside the refrigerator turns on when the refrigerator doors are opened. The driver's side refrigerator door cannot open or close when the vehicle is in motion. Caution: Do not put any objects between the front seats and the center console side walls. The air path could be blocked and cause the unit to stop working. The bin wall will reach -15°C (5°F) while cooling. The operating temperature is 30C (37.4°F). GM BT1YL Automotive Console Cooler Manual Warning: Do not touch bin surfaces with wet or damp hands while the bin is cooling. Skin could stick to the bin surface. The bottom mat is removable. Clean with water and mild soap. Clean the refrigerator bin while the vehicle is turned off. Use a damp, soft rag and wipe the bin carefully. Do not scratch or puncture the bin surfaces. Ensure the bin is dry before turning the refrigerator on. 2 Caution Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s) and Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage; (2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. FCC& IC Radiation Exposure Statement: This equipment complies with FCC and Canada radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Déclaration d’IC sur l’exposition aux radiations: Cet équipement est conforme aux limites d’exposition aux radiations définies par le Canada pour des environnements non contrôlés. Cet émetteur ne doit pas être installé au même endroit ni utilisé avec une autre antenne ou un autre émetteur.

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 1 of 7 Appendix External Photos for GZCR2306000577HS SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 2 of 7 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 3 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 4 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 5 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 6 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 7 of 7

ID Label/Location Info

Product Name: Automotive Console Cooler Part No.: 85047578-A SKU: 9620001658 Series-No.: 001658XXXXXXXXX Volume: 6.0L Refrigerant: R1234yf/0.028kg GWP=4/tCO 2 -eq=0.00012 Operation Voltage: 12 VDC Fridge Max. operation pressure: 290Psi Rated Current: 5.0 A Climatic Class: N or T Supplier Name: Dometic Production Date: YYYYMMDD Contains fluorinated greenhouse gases. Hermetically sealed. FCC ID: 2BBQM-COOLER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. bar cord place 001658XXYYXXXXX YYYYMMDD 表示月份 means Month 表示年份 means Year 表示生产日期 meas Prodution date 哑银龙 Matt silver 生产自行打印 Print by production line 此区域印条形码,条形码内容为产品流水号" 001658 XXYYXXXXX "15位数。 Print barcode in this area, content is product serial No. 001658 XXYYXXXXX, total 15 digits 表示产品的流动编号 从00001到99999再循环到00001 ,每周. The serial No., starts from 00001 to 99999, then recycle to 00001. Every week. 001658XXYYXXXXX 表示年份, 产品制造当年年份 The year No., the digit of the current year of the product manufacture 表述周数, 产品制造当年的第X周 The week No. of the current year of the product manufacture 生产序列号共15位 manufacturing serial No., total 15 digits 8504 7578-A QR: P85047578-A, cell/element: 0.51mm 二维码: 编码内容, P85047578-A二维码单元格0.51mm, 8504 7578-A 前四位字体:Arial narrow bold, 12point First 4 digits, Font: Arial Narrow Bold , 12point 后四位字体:Arial narrow bold, 18point Last 4 digits, Font: Arial Narrow Bold , 18point 二维码共8位(QR Code: 8 digits) 8504 7578-A QR P8504 7578-A NOTE: THIS DRAWING WAS PRODUCED BY COMPUTER, DO NOT UPDATE MANUALLY. A4 01 02 03 04 05 Notice: this drawing is confidential and proprietary to Dometic corporation. Dometic reserves the right to interpret this drawing. Derek.Dai PET

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 1 of 6 Appendix Internal Photos for GZCR2306000577HS SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 2 of 6 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 4 of 6 RF ANT SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 6 of 6

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230600057706 Page: 1 of 11 FCC ID: 2BBQM-COOLER Ricky Liu Manager RF EXPOSURE EVALUATION REPORT Application No.: GZCR2306000577HS Applicant:Dometic (Shenzhen) Electronics Co., Ltd. Address of Applicant:39, Fangkeng Lu, Pinghu, Longgang District, 518111, Shenzhen, Guangdong, China Manufacturer:Dometic (Shenzhen) Electronics Co., Ltd. Address of Manufacturer:39, Fangkeng Lu, Pinghu, Longgang District, 518111, Shenzhen, Guangdong, China Factory:Dometic (Shenzhen) Electronics Co., Ltd. Address of Factory:39, Fangkeng Lu, Pinghu, Longgang District, 518111, Shenzhen, Guangdong, China Equipment Under Test (EUT): EUT Name:Automotive Cooler Model No.: Console Cooler - XX Standard(s) : 47 CFR Part 2.1093 Date of Receipt: 2023-06-13 Date of Evaluation: 2023-06-19 to 2023-07-10 Date of Issue: 2023-12-04 Evaluation Result: Pass* * In the configuration evaluated, the EUT complied with the standards specified above. This report GZCR230600057706 supersedes the previous report GZCR230600057703, issued on 2023-07- 20, which is hereby deemed null and void. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230600057706 Page: 2 of 11 Revision Record VersionReport No.DateRemark 01GZCR2306000577032023-07-20Original (null) 02GZCR2306000577062023-12-04 Amendment report: Updated EUT name and deleted trade mark. Authorized for issue by: Kevin Zhang/Project Engineer Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230600057706 Page: 3 of 11 2Evaluation Summary ItemStandardMethodRequirementResult RF Exposure 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. Remark for amendment report GZCR230600057706 This report GZCR230600057706 supersedes the previous report GZCR230600057703, only updated EUT name and deleted trade mark. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230600057706 Page: 4 of 11 3Contents Page 1Cover Page...............................................................................................................................................1 2Evaluation Summary................................................................................................................................3 3Contents....................................................................................................................................................4 4General Information.................................................................................................................................5 4.1Details of E.U.T.................................................................................................................................5 4.2Evaluating Location...........................................................................................................................5 4.3Facility...............................................................................................................................................6 4.4Deviation from Standards..................................................................................................................6 4.5Abnormalities from Standard Conditions...........................................................................................6 5Technical Requirements Specification..................................................................................................7 5.1RF Exposure Evaluation....................................................................................................................7 5.1.1Limit & Test Method......................................................................................................................7 5.1.2Conclusion..................................................................................................................................10 6EUT Constructional Details (EUT Photos)...........................................................................................11 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230600057706 Page: 5 of 11 4General Information 4.1Details of E.U.T. Power supply:DC 12 V Cable(s):DC input ports Operation Frequency:2402MHz to 2480MHz Modulation Type:GFSK Number of Channels:40 Channel Spacing:2MHz Antenna Type:PCB Antenna Antenna Gain:1.29 dBi Antenna Number:1 4.2Evaluating Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory, 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 Tel: +86 20 82155555Fax: +86 20 82075059 No tests were sub-contracted. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230600057706 Page: 6 of 11 4.3Facility The facility is recognized, certified, or accredited by the following organizations: ● ACMA SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the Australian/New Zealand Regulatory Compliance Mark (RCM). ● SGS UK(Certificate No.: 32), SGS-TUV SAARLAND and SGS-FIMKO Have approved SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of EMC TESTING SERVICES and SAFETY TESTING SERVICES. ● FCC Recognized Accredited Test Firm(Registration No.: 486818) SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been accredited and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Designation Number: CN5016, Test Firm Registration Numbe…

Text truncated - open the document above for the full version.

Test Report

TI05BL02-PA PCB antenna radiation patterns Melange Systems (P) Ltd. # 4/1, 7 th Cross, KumaraPark West, Bangalore - 560 020, India. Tel: +91 (80) 23561023, 23462175 Date: 05 th June, 2023 Document Version: 1.0 TarangMini TI05BL02-PA Module Wireless controls in action Melange Systems Private Limited Page 2 of 4 Melange Systems reserves the right to change the specifications without notice in view of continuous improvement © 2023 Melange Systems Private Limited ALL rights reserved. Doc Ver: 1.0, Preliminary Doc Wireless controls in action Melange Systems Private Limited 1. Module placement in anechoic chamber 2. Module position in H-plane, co-polarization with reference to Horn antenna 3. Module position in H-plane, cross-polarization with reference to Horn antenna Page 3 of 4 Melange Systems reserves the right to change the specifications without notice in view of continuous improvement © 2023 Melange Systems Private Limited ALL rights reserved. Doc Ver: 1.0, Preliminary Doc Wireless controls in action Melange Systems Private Limited 4. 2D pattern of the module in H-plane Co-polarization Page 4 of 4 Melange Systems reserves the right to change the specifications without notice in view of continuous improvement © 2023 Melange Systems Private Limited ALL rights reserved. Doc Ver: 1.0, Preliminary Doc Wireless controls in action Melange Systems Private Limited 5. 2D pattern of the module in H-plane Cross-polarization Note: The radiation pattern can be affected by mounting structures and nearby obstacles located in the proximity of the antenna (near-field)

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230600057705 Page: 1 of 52 FCC ID: 2BBQM-COOLER Ricky Liu Manager TEST REPORT Application No.: GZCR2306000577HS Applicant:Dometic (Shenzhen) Electronics Co., Ltd. Address of Applicant:39, Fangkeng Lu, Pinghu, Longgang District, 518111, Shenzhen, Guangdong, China Manufacturer:Dometic (Shenzhen) Electronics Co., Ltd. Address of Manufacturer:39, Fangkeng Lu, Pinghu, Longgang District, 518111, Shenzhen, Guangdong, China Factory:Dometic (Shenzhen) Electronics Co., Ltd. Address of Factory:39, Fangkeng Lu, Pinghu, Longgang District, 518111, Shenzhen, Guangdong, China Equipment Under Test (EUT): EUT Name:Automotive Cooler Model No.: Console Cooler - XX Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2023-06-13 Date of Test: 2023-06-19 to 2023-07-10 Date of Issue: 2023-12-04 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. This report GZCR230600057705 supersedes the previous report GZCR230600057702, issued on 2023-07- 20, which is hereby deemed null and void. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230600057705 Page: 2 of 52 Revision Record VersionReport No.DateRemark 01GZCR2306000577022023-07-20Original (null) 02GZCR2306000577052023-12-04Amendment report: Updated EUT name and deleted trade mark. Authorized for issue by: Kevin Zhang/Project Engineer Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230600057705 Page: 3 of 52 2Test Summary Radio Spectrum Technical Requirement ItemStandardMethodRequirementResult Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part ItemStandardMethodRequirementResult Conducted Peak Output Power ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 11.12 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Frequency Stability Required by applicant ANSI C63.10 (2013) Section 6.8 Required by manufacturePass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. Remark for amendment report GZCR230600057705 This report GZCR230600057705 supersedes the previous report GZCR230600057702, only updated EUT name and deleted trade mark. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230600057705 Page: 4 of 52 3Contents Page 1Cover Page...............................................................................................................................................1 2Test Summary..........................................................................................................................................3 3Contents....................................................................................................................................................4 4General Information.................................................................................................................................6 4.1Details of E.U.T.................................................................................................................................6 4.2Description of Support Units..............................................................................................................6 4.3Measurement Uncertainty.................................................................................................................6 4.4Test Location.....................................................................................................................................7 4.5Test Facility.......................................................................................................................................7 4.6Deviation from Standards..................................................................................................................7 4.7Abnormalities from Standard Conditions...........................................................................................7 5Equipment List.........................................................................................................................................8 6Radio Spectrum Technical Requirement.............................................................................................11 6.1Antenna Requirement......................................................................................................................11 6.1.1Test Requirement:.......................................................................................................................11 6.1.2Conclusion..................................................................................................................................11 7Radio Spectrum Matter Test Results...................................................................................................12 7.1Conducted Peak Output Power..................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 1 of 2 Appendix Test Setup Photo for GZCR230600057705 Test Model No.: Console Cooler - XX SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 2 of 2 Test Setup Photo Radiated Emissions which fall in the restricted bands & Radiated Spurious Emissions

Contact Information

Applicant

Wind Qiu(Compliance Engineer)
[email protected]86 (0)755 2845 7350Fax: 86 (0)755-28455132

Technical Contact

SGS-CSTC Standards Technical Services Co., LtdBonnie Liao
[email protected]82155379

No.198 Kezhu Road, · Guangzhou, Guangdong · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., LtdBonnie Liao
[email protected]82155379

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd.Bonnie Liao
[email protected]02082155379

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.16 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted.