Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Warning 6 tatement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.
1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: CompanyName:StoneTradingLimited FRN:0033401936 ContactName:DongmeiFang Address:6547NAcademyBlvd#2266,ColoradoSprings,CO80918,UnitedStates TelephoneNo:+12134573118 Email:[email protected] Applicant: Companyname:DongguanMaverickIndustrialCo.,Ltd. ProductDescription:MagSafeWirelessNotebookwithVideoPlayerandUSB Granteecode:2BBRI FCCID:2BBRI-MSV086WS ContactName:ChongyangLiu Address:ZhenhuaIndustrialArea,QiShiTown,Dongguancity,China TelephoneNo:+8613570898215 Email:[email protected] [ShenzheniDEEBOTechnologyCo.,Ltd.]certifiesthat,asofthedateofthisfilingof theapplicationwiththeTCB,[StoneTradingLimited]isourdesignatedUSagent forserviceofprocessfortheabovereferencedFCCID.[ShenzheniDEEBO TechnologyCo.,Ltd.]acceptstomaintainanagentfornolessthanoneyearafter thegranteehasterminatedallmarketingandimportationortheconclusionof anycommissionrelatedproceedinginvolvingequipment.[StoneTradingLimited] accepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedUSagentforserviceofprocessfortheabovereferenceFCCID. TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause §2.911. TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. Date:2023/07/05 Applicant’sName:ChongyangLiuUSAgent’sName:DongmeiFang Title:managerTitle:manager SignatureSignature
Dongguan Maverick Industrial Co., Ltd. (2023-7-5) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID:2BBRI-MSV086WS) Dongguan Maverick Industrial Co., Ltd. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature): (Applicant printed name): Chongyang Liu Dongguan Maverick Industrial Co., Ltd. (2023-7-5) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID:2BBRI-MSV086WS) Dongguan Maverick Industrial Co., Ltd. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature): (Applicant printed name): Chongyang Liu
Dongguan Maverick Industrial Co., Ltd. Agent Authorization Letter (2023/07/05) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen ZKT Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature : Client’s name / title : Chongyang Liu / Manager Contact information / address: Zhenhua Industrial Area, QiShi Town,Dongguan city, China
Dongguan Maverick Industrial Co., Ltd. Long Term Confidentiality Request Letter (2023-07-05) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (MagSafe Wireless Notebook with Video Player and USB / MK-MSV086ws(15W), MK-066ws, MK-068wss, MK-069ws, MK- 070ws, MK-075ws, MK-076ws, MK-079ws, MK-082ws, MK-090ws, MK- MSV086ws, MK-MS087ws, MK-MS088ws, MK-089ws, MK-RMS093ws, MK- L095ws, MK-096ws, MK-MS098ws, MK-L101ws, MK-MS102ws, MK-MS103ws / FCC ID:2BBRI-MSV086WS) To Whom It May Concern: - This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature : Client’s name / title : Chongyang Liu / Manager Contact information / address: Zhenhua Industrial Area, QiShi Town,Dongguan city, China
Dongguan Maverick Industrial Co., Ltd. Dongguan Maverick Industrial Co., Ltd. Statement Product Name: MagSafe Wireless Notebook with Video Player and USB ModelNo.: MK-MSV086ws(15W), MK-066ws, MK-068wss, MK-069ws, MK-070ws, MK-075ws, MK-076ws, MK-079ws, MK-082ws, MK-090ws, MK-MSV086ws, MK-MS087ws, MK-MS088ws, MK-089ws, MK-RMS093ws, MK-L095ws, MK-096ws, MK-MS098ws, MK-L101ws, MK-MS102ws, MK-MS103ws All the models above are identical in interior structure, electrical circuits and components; just model name and colour are different. The model MK-MSV086ws(15W) has been tested. Signature: Name / title: Chongyang Liu / Manager Tel: (86)13926853918 Email: [email protected] Date: 2023-07-05
4cm Model: MK-MSV086ws(15W) FCC ID: 2BBRI-MSV086WS This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may causeundesired operation. Label Location 2cm
TX ANT
FCC ID:2BBRI-MSV086WS RF Exposure Evaluation 1 Measuring Standard KDB 680106 RF Exposure Wireless Charging Apps v03r01 2 Requirements According to the item 5 of KDB 680106 v03r01: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. (1) Power transfer frequency is less than 1MHz. Yes, the device operate in the frequency range from 110KHz to 205KHz (2) Output power from each primary coil is less than or equal to 15 watts. Yes, the maximum output power of the primary coil is 15000mW. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. Yes, the transfer system includes only single primary and secondary coils. (4) Client device is placed directly in contact with the transmitter. Yes, client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). No, submit a KDB inquiry to get test guideline and fully follow the KDB inquiry guideline. (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes, the EUT field strength levels are less 50% x MPE limit. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) 3 Test Setup 4 Test Procedure a) The RF exposure test was performed on 360 degree turn table in anechoic chamber. b) The measurement probe was placed at test distance (0-20cm) which is between the edge of the charger and the geometric centre of probe, Move the bracket to adjust the distance. c) The turn table was rotated 360d degree to search of highest strength. d) The highest emission level was recorded and compared with limit as soon as measurement of each points were completed. e) The EUT were measured according to the dictates of KDB 680106v03r01. Note: The radius of the probe is 4.7mm, and the center of the probe sensing element is less than 5 mm from the probe outer edge. 5 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) EMF TESTER Wavecontrol SMP160 19SN0989 2021.08.20 2023.08.29 6 Test Result H-Filed Strength at 20 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.15 0.16 0.16 0.14 1.63 H-Filed Strength at 20 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.17 1.63 H-Filed Strength at 18 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.19 0.19 020 0.21 1.63 H-Filed Strength at 18 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.22 1.63 H-Filed Strength at 16 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.26 0.26 0.25 0.26 1.63 H-Filed Strength at 16 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.27 1.63 H-Filed Strength at 14 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.32 0.31 0.31 0.31 1.63 H-Filed Strength at 14 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.32 1.63 H-Filed Strength at 12 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.36 0.35 0.34 0.36 1.63 H-Filed Strength at 12 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.36 1.63 H-Filed Strength at 10 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.42 0.41 0.42 0.42 1.63 H-Filed Strength at 10 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.43 1.63 H-Filed Strength at 8 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.48 0.47 0.47 0.48 1.63 H-Filed Strength at 8 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.49 1.63 H-Filed Strength at 6 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.52 0.52 0.51 0.51 1.63 H-Filed Strength at 6 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.54 1.63 H-Filed Strength at 4 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.57 0.57 0.56 0.57 1.63 H-Filed Strength at 4 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.58 1.63 H-Filed Strength at 2 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 0.115-0.205 0.62 0.62 0.62 0.63 1.63 H-Filed Strength at 2 cm from the top of the EUT (A/m) Frequency Range (MHz) Test Position E Limits (A/m) 0.115-0.205 0.63 1.63 H-Filed Strength at 0 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test …
Text truncated - open the document above for the full version.
1 Antenna specification 1、Antenna introduction The TX antenna is directly used on the Loop Antenna. Manufacturer: Shenzhen xlw technolog9y Address: A436, Huafeng Internet Creative Park, No.107 Gong He Industrial Road, Xix iang, Bao'An, Shenzhen, 518102, China 2、Antenna shape 3、Antenna parameter The TX antenna operates at 115kHz ~ 205kHz and generates resonance in this band. The table below shows the main parameters of the antenna. Frequency(MHz) 115kHz ~ 205kHz VSWR ≤ 2.0 Impedance 50 Ohm Nominal Gain (Peak) 0dBi
Project No.:ZKT-230615L4507E Page 1 of 21 FCC TEST REPORT FCC ID:2BBRI-MSV086WS Report Number. .............................. : ZKT-230615L4507E Date of Test ................................................. : June 15, 2023 to June 20, 2023 Date of issue .................................... : June 20, 2023 Total number of pages ...................... 21 Test Result ..................................... : PASS Testing Laboratory. ........................ : Shenzhen ZKT Technology Co., Ltd. Address .......................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Applicant's name ......................... : Dongguan Maverick Industrial Co., Ltd. Address .......................................... : Zhenhua Industrial Area, QiShi Town,Dongguan city, China Manufacturer's name ................... : Dongguan Maverick Industrial Co., Ltd. Address .......................................... : Zhenhua Industrial Area, QiShi Town,Dongguan city, China Test specification: Standard ........................................... : FCC CFR Title 47 Part 15 Subpart C Test procedure ................................. : / Non-standard test method ............. : N/A Test Report Form No. .................... : TRF-EL-107_V0 Test Report Form(s) Originator .... : ZKT Testing Master TRF .................................... : Dated: Apr. 22, 2022 This device described above has been tested by ZKT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ZKT, this document may be altered or revised by ZKT, personal only, and shall be noted in the revision of the document. Product name ................................. : MagSafe Wireless Notebook with Video Player and USB Trademark ...................................... : N/A Model/Type reference ...................... : MK-MSV086ws(15W), MK-066ws, MK-068wss, MK-069ws, MK-070ws, MK-075ws, MK-076ws, MK-079ws, MK-082ws, MK-090ws, MK-MSV086ws, MK-MS087ws, MK-MS088ws, MK-089ws, MK-RMS093ws, MK-L095ws, MK-096ws, MK-MS098ws, MK-L101ws, MK-MS102ws, MK-MS103ws Ratings.............................................: Input: 5V 3A;9V 2A;9V 2.22A;12V 1.5A Output: 15W/10W/7.5W/5W Project No.:ZKT-230615L4507E Page 2 of 21 Testing procedure and testing location: Testing Laboratory ................................... : Shenzhen ZKT Technology Co., Ltd. Address ...................................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Alen He Tested by (name + signature) .................... : Joe Liu Reviewer (name + signature) ..................... : Lake Xie Approved (name + signature) .................... : Project No.:ZKT-230615L4507E Page 3 of 21 TABLE OF CONTENTS 1. VERSION ....................................................................................................................................... 4 2. TEST SUMMARY ........................................................................................................................ 5 2.1 TEST FACILITY .................................................................................................................................... 6 2.2 MEASUREMENT UNCERTAINTY .................................................................................................... 6 3. GENERAL INFORMATION ....................................................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT ................................................................................................. 7 3.2 Test mode .............................................................................................................................................. 7 3.3 Block Diagram of EUT Configuration ................................................................................................ 7 3.4 Test Conditions ..................................................................................................................................... 7 3.5 Description Of Support Units (Conducted Mode) ............................................................................ 7 3.6 EQUIPMENTS LIST FOR ALL TEST ITEMS .................................................................................. 9 4. CONDUCTED EMISSION TEST ............................................................................................. 10 4.1 CONDUCTED EMISSION MEASUREMENT ................................................................................ 10 4.2 POWER LINE CONDUCTED EMISSION Limits ........................................................................... 10 4.3 TEST PROCEDURE .......................................................................................................................... 10 4.4 DEVIATION FROM TEST STANDARD .......................................................................................... 10 4.5 TEST SETUP ...................................................................................................................................... 11 4.6 EUT OPERATING CONDITIONS .................................................................................................... 11 4.7 Test Result .......................................................................................................................................... 12 5. RADIATED EMISSION MEASUREMENT ............................................................................ 14 5.1 Radiated Emission Limits .................................................................................................................. 14 5.2 Anechoic Chamber Test Setup Diagram ................................................................…
Text truncated - open the document above for the full version.
Test Setup Photograph Radiated Emissions Test Setup Below 30MHz Below 1G Conduction Emissions Test Setup
Test Setup Photograph
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.115 MHz - 0.205 MHz | - |